• Title/Summary/Keyword: Co-fire

Search Result 941, Processing Time 0.023 seconds

The Characteristics of $CO_2 $ Extinguishant Transfer According to the Nozzle Conditions of a Fixed Eire System (고정식 소화장치 노즐조건에 따른 $CO_2 $전달특성)

  • 박찬수;최주석;전철균
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.41-48
    • /
    • 2004
  • We have conducted a numerical simulation under three-dimensional unsteady conditions in order to analyze the characteristics of $CO_2 $;, extinguishant transfer by varying the location of the injection nozzle, which affects the effect of a $CO_2 $;, fire fighting system used in the form of fixed systems for the marine engine room. Flow fields and $CO_2 $;, concentration fields were measured according to the location of the injection nozzle. In the case of arranging the injection nozzle on the center of the ceiling, the low-normal concentration distribution was developed along the $CO_2 $;, jet due to the downward flow created by impinging ceiling jets in the symmetric plane. The concentration line reaches its peak due to the mass transfer of $CO_2 $;, at the comer.

A Study on Application of Combustion Products for Forest Fire Investigation (산불화재 감식을 위한 연소생성물의 응용에 관한 연구)

  • Park, Young-Ju;Lee, Hae-Pyeong
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.111-119
    • /
    • 2011
  • This study was designed to provide basic data applicable to fire investigation through consideration of combustion products and propose vulnerability of combustibles through analysis of $CO_2$ emission. In order to achieve these research objectives, characteristics of combustion products such as smoke release rate of each part(raw leaves, branches and barks), $CO_2$ emission and ash production were considered targeting on 6 oak species(Quercus variabilis Blume, Quercus aliena Blume, Quercus serrata, Quercus mongolica Fisch, Quercus dentata Sapling and Quercus acutissima) using cone calorimeter and smoke density tester. As a result, it was found that raw leaves release smoke more relatively than branches and barks, when they burn, and that Quercus variabilis Blume has the highest smoke density. Also, Quercus acutissima released CO and $CO_2$ which are respectively, 6.67 times and 1.43 times more than Quercus variabilis Blume with low $CO_2$ emission. In addition, branches released CO and $CO_2$ more relatively. There was a big difference in ash production among raw leaves(3.1 g), branches(10.5 g) and barks(16.43 g). It was identified that Quercus serrata produces ashes which are nearly 9.95 times more than Quercus variabilis Blume. It demonstrates that Quercus serrata contains relatively higher minerals and that Quercus variabilis Blume can leave lots of traces like stain and carbonization, as it releases smoke a lot and it's difficult to predict visibility, when a forest fire breaks out in its community area. It is also considered that smoke particles containing oil in the air leave strain on the surface of a tree, and that CO and $CO_2$ emission increases, when crown fire to burn branches breaks out.

The Report on Test Results of CO Fire Extinguishing System ($CO_2$ 소화설비 구성부품 성능시험보고)

  • Kim, Gi-Ok;Lee, Chan-Ju;An, Byeong-Ho
    • Fire Protection Technology
    • /
    • s.14
    • /
    • pp.5-12
    • /
    • 1993
  • This report is explained about test results of carbon dioxide extinguiching system components and pack-age type system (Kits) for automatic fire extinguishing system. A carbon dioxide system may be used to protect one or more hazards or hazards by menas of directional valves. Package system shall be installed to protect hazards within the limitations. The testing program was progressed by three items, external oppearance test, performance test and Total Flooding Fire Extinguishing System test. The object of this report is present the problem which apperar from the analysis of test results.

  • PDF

Reliability of the Performance-Based Design: International Cases (성능위주설계의 신뢰성 확보를 위한 외국 사례 검토)

  • Hwang, Jun-Ho;Moon, Sung-Woong;Choi, Kyu-Chool;Ryu, Sang-Hoon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.151-154
    • /
    • 2011
  • 법률 중심적인 사양위주 설계의 한계를 극복하고자 국내 외 다양한 분야에서 성능위주 설계가 사용되고 있다. 국내에 도입된 소방 설비에 대한 성능위주 설계는 도입단계로 볼 수 있어, 선진국의 사례를 통해 도입 초기인 현재 발생할 수 있는 문제점과 대안을 분석하였다.

  • PDF

Quantitative Analysis on the Electrical Fire Preventive Effect of Safety Inspection for Electrical Facilities for General Use (일반용 전기설비 안전점검의 전기화재 예방효과에 대한 정량적 분석)

  • Kim, Taek-Hee;Yoo, Jae-Geun;Jeon, Jeong-Chay
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.45-49
    • /
    • 2015
  • This paper presents a quantitative analysis method to quantitatively indicate a electrical fire preventive effect of safety inspection for electrical facilities for general use. Logic model was developed based on whether enforcement of safety inspection for electrical facilities, and then the developed analysis model was converted to hydraulic model by using mathematical logic. The electrical fire preventive effect of safety inspection for electrical facilities was quantitatively calculated by applying electrical safety inspection results and fire statistics for five years to the developed hydraulic model. The results show that electrical fire preventive effects of 5,542 cases on annual average for five years.

The Characteristic Evaluation of Fire-Resistance test by Cable Transit For Organic Expansion Sealing material (케이블 관통부의 유기 팽창물을 이용한 밀폐재 내화성 특성 평가)

  • Lim, Sung-Sik;Ki, Myeong-Seok;Jeong, Hyuk;So, Byoung-Ki;Kang, Ki-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.198-199
    • /
    • 2007
  • The Cable Transit has an adaptable center hole for accommodating a cable to be passed through the wall(bulkhead/deck). The Cable Transits Sealing System must have important character which seal and protect against fire, smoke, gas, water, etc and consist of natal frame, sealing system and the cable, insulation. In this paper, introduced our cable transit organic expansion sealing material system, fire-resistance test and test result, etc. We carry to fire-resistance test in according to FTP Code Part 3(IMO Res. A. 754(18)) for A-60 class cable transit and the test result for our cable transit sealing system was satisfied.

  • PDF

A Study on the Verification Scheme for Electrical Circuit Analysis of Fire Hazard Analysis in Nuclear Power Plant (원전 화재위험도분석에서 전기회로분석 검증방안에 관한 연구)

  • Yim, Hyuntae;Oh, Seungjun;Kim, Weekyong
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.114-122
    • /
    • 2015
  • In a fire hazard analysis (FHA) for nuclear power plant, various electrical circuit analyses are performed in the parts of fire loading analysis, fire modeling analysis, separation criteria analysis, associated circuit analysis, and multiple spurious operation analysis. Thus, electrical circuit analyses are very important areas so that reliability of the analysis results should be assured. This study is to establish essential electrical elements for each analysis for verification of the reliability of the electrical circuit analyses in the fire hazard analysis for nuclear power plants. Applying the results derived by the study to domestic nuclear power plants, it is expected to determine the adequacy of the fire hazard analysis report and contribute to the reliability of the fire hazard analysis of those plants.

A Study on the Emissions of CO2/non-CO2 for the Crown Layer and Surface Layer of Pine Trees (소나무류 수관층 및 지표층의 CO2/non-CO2 배출량 분석 연구)

  • Park, Young Ju;Lee, Hae Pyeong;Baek, Chang Sun
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.111-118
    • /
    • 2015
  • In this study, we carried out the emissions analysis of CO and $non-CO_2$ for the age-classes of various pine trees(Pinus koraiensis, Pinus densiflora, Pinus rigida Mill., Pinus thunbergii Parl.) to estimate of emission factors of the crown layer and surface layer in the forest fire. We used the thermal characteristic analyzer cone heater and NDIR analyzer in order to measure amount of emission. As a result, the major emissions of Pinus koraiensis were $CO_2$ and $CH_4$ and that of Pinus thunbergii Parl. was only CO. The major emissions of the most of pine trees were NO and $N_2O$. The $CO_2$ emission of Pinus thunbergii Parl. was the highest about as $7.26{\times}10^{-2}{\sim}1.63{\times}10^{-1}g$ and next came Pinus densiflora, Pinus koraiensis, Pinus rigida Mill.. And the CO emission of Pinus thunbergii Parl. was about $5.14{\times}10^{-3}{\sim}6.58{\times}10^{-3}g$ and followed by Pinus densiflora, Pinus koraiensis, Pinus rigida Mill.. The emissions of $CH_4$, NO, and $N_2O$ showed small differences between species and the emission of $CH_4$ was $8.37{\times}10^{-5}{\sim}2.55{\times}10^{-4}g$, and NO was $6.65{\times}10^{-5}{\sim}2.0{\times}10^{-4}g$ and $N_2O$ was $1.42{\times}10^{-4}{\sim}2.09{\times}10^{-3}g$ in all species. Particularly, the emission of Pinus thunbergii Parl. was the highest in all pine trees except $CH_4$.