• 제목/요약/키워드: Co-exfoliation

검색결과 32건 처리시간 0.015초

Surface characteristics of a novel hydroxyapatite-coated dental implant

  • Jung, Ui-Won;Hwang, Ji-Wan;Choi, Da-Yae;Hu, Kyung-Seok;Kwon, Mi-Kyung;Choi, Seong-Ho;Kim, Hee-Jin
    • Journal of Periodontal and Implant Science
    • /
    • 제42권2호
    • /
    • pp.59-63
    • /
    • 2012
  • Purpose: This study evaluated the surface characteristics and bond strength produced using a novel technique for coating hydroxyapatite (HA) onto titanium implants. Methods: HA was coated on the titanium implant surface using a super-high-speed (SHS) blasting method with highly purified HA. The coating was performed at a low temperature, unlike conventional HA coating methods. Coating thickness was measured. The novel HA-coated disc was fabricated. X-ray diffraction analysis was performed directly on the disc to evaluate crystallinity. Four novel HA-coated discs and four resorbable blast medium (RBM) discs were prepared. Their surface roughnesses and areas were measured. Five puretitanium, RBM-treated, and novel HA-coated discs were prepared. Contact angle was measured. Two-way analysis of variance and the post-hoc Scheffe's test were used to analyze differences between the groups, with those with a probability of P<0.05 considered to be statistically significant. To evaluate exfoliation of the coating layer, 7 sites on the mandibles from 7 mongrel dogs were used. Other sites were used for another research project. In total, seven novel HA-coated implants were placed 2 months after extraction of premolars according to the manufacturer's instructions. The dogs were sacrificed 8 weeks after implant surgery. Implants were removed using a ratchet driver. The surface of the retrieved implants was evaluated microscopically. Results: A uniform HA coating layer was formed on the titanium implants with no deformation of the RBM titanium surface microtexture when an SHS blasting method was used. Conclusions: These HA-coated implants exhibited increased roughness, crystallinity, and wettability when compared with RBM implants.

당진 신암사 금동여래좌상의 표면특성 분석과 비파괴 정밀진단을 통한 제작기술 해석 (Interpretation of Making Techniques through Surface Characteristic Analysis and Non-destructive Diagnosis for the Gilt-bronze Seated Buddha in Dangjin Sinamsa Temple, Korea)

  • 최일규 ;양혜리 ;한두루 ;이찬희
    • 헤리티지:역사와 과학
    • /
    • 제56권1호
    • /
    • pp.100-116
    • /
    • 2023
  • 당진 신암사는 고려 후기에 창건된 사찰이며, 경내의 극락전에는 금동여래좌상이 봉안되어 있다. 이 불상의 개금층은 박락과 광택이 저하되는 등 여러 손상이 발생하였다. 이 연구에서는 재료학적 분석과 비파괴 진단을 통해 불상의 내부와 외부에 대한 보존상태를 정밀 검토하였으며, 이를 근거로 제작기법을 해석하였다. 이 결과, 개금층은 순금을 사용한 것으로 판단되며 안료에서 흑색은 먹, 녹색은 석록과 염화동 및 동록 등으로, 적색은 연단 또는 진사가 사용된 것으로 추정된다. 손상도 평가 결과, 개금층의 벗겨짐, 균열, 탈락 및 박리 등이 확인되나 보존상태는 비교적 건전하다. 그러나 개금층의 광택은 유지부에 비해 저하부가 더 넓게 산출된다. 이 불상에 대한 초음파 속도측정 결과 1,230~3,987(평균 2,608)m/s로 비교적 넓은 범위를 보였으며, 적외선 열화상으로 박리는 확인되지 않았고 특별한 접합흔도 발견되지 않는다. 내시경 검사에서는 내부 소지금속의 부식과 생물학적 피해가 다소 관찰되었으며, 봉안된 복장물이 확인되었다. 이를 종합하여 제작기법을 검토한 결과, 이 금동여래좌상은 통주조로 제작하였으며 주형을 거꾸로 뒤집어 용탕을 주입한 것으로 판단된다.