• Title/Summary/Keyword: Co-energy

Search Result 8,008, Processing Time 0.038 seconds

Mouse model system based on apoptosis induction to crypt cells after exposure to ionizing radiation (방사선에 전신 조사된 마우스 음와 세포의 아포토시스 유도를 이용한 생물학적 선량 측정 모델 개발 연구)

  • Kim, Tae-Hwan
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.4
    • /
    • pp.571-578
    • /
    • 2001
  • To evaluate if the apoptotic fragment assay could be used to estimate the dose prediction after radiation exposure, we examined apoptotic mouse crypt cells per 1,000 cells after whole body $^{60}Co$ $\gamma$-rays and 50MeV ($p{\rightarrow}Be^+$) cyclotron fast neutron irradiation in the range of 0.25 to 1 Gy, respectively. The incidence of apoptotic cell death rose steeply at very low doses up to 1 Gy, and radiation at all doses tigger rapid changes in crypt cells in stem cell region. These data suggest that apoptosis may play an important role in homeostasis of damaged radiosensitive target organ by removing damaged cells. The curve of dose-effect relationship for the data of apoptotic fragments was obtained by the linear-quadratic model $y=0.18+(9.728{\pm}0.887)D+(-4.727{\pm}1.033)D^2$ ($r^2=0.984$) after $\gamma$-rays irradiation, while $y=0.18+(5.125{\pm}0.601)D+(-2.652{\pm}0.7000)D^2$ ($r^2=0.970$) after neutrons in mice. The dose-response curves were linear-quadratic, and a significant dose-response relationship was found between the frequency of apoptotic cell and dose. These data show a trend towards increase of the numbers of apoptotic crypt cells with increasing dose. Both the time course and the radiation dose-response curve for high and low linear energy transfer (LET) radiation modalities were similar. The relative biological effectiveness (RBE) value for crypt cells was 2.072. In addition, there were significant peaks on apoptosis induction at 4 and 6h after irradiation, and the morpholoigcal findings of the irradiated groups were typical apoptotic fragments in crypt cells that were hardly observed in the control group. Thus, apoptosis in crypt cells could be a useful in vivo model for studying radio-protective drug sensitivity or screening test, microdosimetric indicator and radiation-induced target organ injury. Since the apoptotic fragment assay is simple, rapid and reproducible in the range of 0.25 to 1 Gy, it will also be a good tool for evaluating the dose response of radiation-induced organ damage in vivo and provide a potentially valuable biodosimetry for the early dose prediction after accidental exposure.

  • PDF

Effects of Dietary ${\beta}-1,3$ Glucan on Growth and Immune Responses in Juvenile Olive Flounder, Paralichthys olivaceus (치어기 넙치 사료내 ${\beta}-1,3$ 글루칸의 첨가가 성장 및 비특이적 면역반응에 미치는 영향)

  • Kim, Young-Chul;Kim, Kang-Woong;Lee, Seung-Hyung;Park, Gun-Jun;Okorie, Okorie Eme;Kang, Yong-Jin;Bai, Sung-Chul C.
    • Journal of Aquaculture
    • /
    • v.19 no.4
    • /
    • pp.247-253
    • /
    • 2006
  • This study was conducted to investigate the effects of dietary supplementation of ${\beta}-1,3$ glucan on growth and immune responses in juvenile olive flounder, Paralichthys olivaceus fed the white fish meal based diets for 6 weeks. Five experimental diets supplemented with ${\beta}-1,3$ glucan at 0, 0.01, 0.025, 0.05, 0.1 % (Control, $G_{0.01},\;G_{0.025},\;G_{0.05}\;and\;G_{0.1}$, respectively) of diet on a dry-matter basis. Five experimental diets were formulated to be isonitrogenous and isocaloric to contain 50.0% crude protein and 16.7 kJ available energy $g^{-1}$. Fish averaging $3.2{\pm}0.1\;g\;(mean{\pm}SD)$ were randomly distributed in each aquarium as triplicate groups of 15 fish. Weight gain (WG, %), specific growth rate (SGR, %), and feed efficiency (FE, %) of fish fed $G_{0.1}$ diet were found significantly higher than those of fish fed Control, $G_{0.01},\;G_{0.025}\;and\;G_{0.05}$ diets (P<0.05). However, there was no significant difference among the fish fed control, $G_{0.01},\;G_{0.025}$. Chemiluminescent responses (CL) of fish fed $G_{0.1}$ diet were significantly higher than those of fish fed the other diets. Serum lysozyme activities of fish fed $G_{0.05}$ and $G_{0.1}$ diets were higher than those of fish fed control, $G_{0.025}$ and $G_{0.05}$ diets. Fish fed $G_{0.1}$ diet showed a significantly lower cumulative mortality than did fish fed control diet throughout the challenge test (P<0.05). These results suggested that based on growth rate, feed efficiency, non-specific immunity and protection against microbial infections the optimum dietary ${\beta}-1,3$ gulcan could be greater than 0.05% but less than 1.0% in juvenile olive flounder, Paralichthys oilvaceus.

Characteristics and breeding of a new cultivar of Pleurotus ostreatus 'Soltari' (느타리 신품종 '솔타리'의 육성 및 자실체 특성)

  • Oh, Min-Ji;Shin, Pyung-Gyun;Oh, Youn-Lee;Jang, Kab-Yeul;Woo, Sung-I;Kong, Won-Sik
    • Journal of Mushroom
    • /
    • v.14 no.4
    • /
    • pp.202-206
    • /
    • 2016
  • Oyster mushrooms are widely cultivated and consumed in Korea. P. ostreatus 'Suhan(ASI 2504)' is an ideal cultivar for mushroom farmers due to its dark pileus and thick stipe; however, as it is very sensitive to environmental conditions, an alternative cultivar is required. To develop a new cultivar, parental strains 'Suhan(ASI 2504)' and 'ASI 0665 (Heuktari)' were selected from various collected strains according to morphological characteristics. P. ostreatus 'Soltari' was developed by DiMon crossing between the dikaryotic strain 'Suhan' and the monokaryotic strain derived from 'Heuktari'. Thirty-eight of the 100 crossed strains were selected following analysis of mitochondrial genetic characteristics, and 'Soltari' was ultimately selected by continuous cultivation tests. The mitochondrial DNA profile of 'Soltari' was found to be the same as that of 'Heuktari, and a nuclear DNA profile of 'Soltari' was similar as those of the parental strains, 'Suhan' and 'Heuktari.' 'Soltari' mycelium grows adequately in moderate to high temperatures of $12-20^{\circ}C$, although its optimum temperature was found to be $30^{\circ}C$. Fruiting body production per 1.1-L cultivation bottle was approximately 158.8 g. Its stipe length and thickness were comparable to those of diameter and thickness were somewhat lower (42.72 vs. 51.33 mm and 18.18 vs. 22.46 mm, respectively). 'Soltari' was found to be more resistant to high $CO_2$ atmosphere than 'Suhan', and the color of the pileus of 'Soltari' was dark gray at high temperature. Therefore, it is suggested that this new cultivar 'Soltari' is a good alternative cultivar and will contribute to energy saving in oyster mushroom farms.

Case Report of Radiotherapy to a Breast Cancer Patient with a Pacemaker (인공심장박동기가 이식된 유방암환자의 방사선 치료에 대한 사례 보고)

  • Chae, Seung-Hoon;Park, Jang-Pil;Lee, Yang-Hoon;Yoo, Suk-Hyun;Seong, Won-Mo;Kim, Kyu-Bo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.197-203
    • /
    • 2012
  • Purpose: In this study, we considerate our radiation therapy process for the breast cancer patient implanted a pacemaker applying the machine movement surgery, shielding, beam selection. Materials and Methods: We perform radiation therapy to a 54 years old, breast cancer patient implanted a pacemaker. The patient underwent a surgery to move the position of a pacemaker to right side breast after consultation with cardiology department. Prescribed dose was 5,040 cGy and daily dose 180 cGy for 28 fractions. The 10 MV photon energy, field size 0/$9.5{\times}20$ cm, half beam and opposing portal irradiation are used. To find out appropriate thickness of shielding board, we carried out an experiment using a solid water phantom ($30{\times}30{\times}7$ cm), a Farmer-type chamber (TN30013, PTW, Germany) and a shielding board (Pb $28{\times}27{\times}0.1$ cm). We calculated expected absorbed dose to te pacemaker with absorb ratio and shielding ratio. In the PTP system (Eclipse, Varian, USA), we figured out how much radiation would be absorbed to the machine with and without shielding. First day of the radiation therapy, we measured head scatter to the pacemaker with MOSFET Dose Verification System (TN-RD-70-W, Medical Canada Ltd., Canada). Results: In the phantom measurement, we found out appropriate thickness was 2 mm of shielding board. In the RTP, when using 2 mm shielding the pacemaker will be absorbed 11.5~38.2 cGy and DVH is 77.3 cGy. In the first day of the therapy, 4.3 cGy was measured so 120.4 cGy was calculated during total therapy. The patient was free from any side effects, and the machine also normally functioned. Conclusion: As the report of association which have public confidence became superannuated, there is lack of data about new machine. We believe that radiation therapy to thiese kind of patients could be done successfully with co-operation, patient-suitable planning, accurate QA, frequent in-vivo dosimetry and monitoring.

  • PDF

Pyrolysis Characteristics of CCL(Copper Clad Laminate) Based Paper/Phenolic Resin Composites (종이/페놀수지가 주성분인 동박적층판(Copper Clad Laminate)의 열분해 특성)

  • Song, Jae-Hun;Kim, Seung-Do;Ahn, Hyun-Cheol;Kim, Gyung-Soo;Kim, Sang-Bum;Jung, Jae-Sung;Gong, Sung-Ho;Cho, Young-Gae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.9
    • /
    • pp.1013-1019
    • /
    • 2007
  • Electronic wastes have increased tremendously. However, any reliable treatment methodologies have rarely been established. Electronic wastes have posed serious disposal problem due to their physico-chemical stability. This paper investigated the application possibility of pyrolysis for the purpose of recycling the p-CCL(phenol based Copper Clad Laminate). Thermogravimetric analysis(TGA) was used to investigate the thermal decomposition pattern of p-CCL. We elucidated the characteristics of pyrolysis by-products at operating temperatures of 280, 350 and $600^{\circ}C$. GC/MS and FT-IR were used to characterize the liquid by-products along with general characterization methods such as Ultimate Analysis, Proximate Analysis and Heating Value, whereas general characterization methods were only introduced for the solid by-products. At a heating rate of $5^{\circ}C$/min, TGA curves exhibited three decomposition stages: (1) low-temperature decomposition region$(<280^{\circ}C)$, (2) medium temperature region$(280\sim350^{\circ}C)$ and (3) high-temperature region$(>350^{\circ}C)$. The major compounds of liquid by-products at low- and medium-temperatures were accounted for by water and phenol, whereas branched phenols and furans were major compounds at high-temperatures. As the temperature increases, volatile quantities decreased but the fixed carbon increased. High heating values of solid by-products($7,400\sim7,600$ kcal/kg) would suggest that the solid by-products could be applicable as fuel. In addition, high fixed carbon but low ash content of the solid by-products offered an implication that they are capable of being upgradable for adsorbent after applying appropriate activating process.

A Study on Load-carrying Capacity Design Criteria of Jack-up Rigs under Environmental Loading Conditions (환경하중을 고려한 Jack-up rig의 내하력 설계 기준에 대한 연구)

  • Park, Joo Shin;Ha, Yeon Chul;Seo, Jung Kwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.1
    • /
    • pp.103-113
    • /
    • 2020
  • Jack-up drilling rigs are widely used in the offshore oil and gas exploration industry. Although originally designed for use in shallow waters, trends in the energy industry have led to a growing demand for their use in deep sea and harsh environmental conditions. To extend the operating range of jack-up units, their design must be based on reliable analysis while eliminating excessive conservatism. In current industrial practice, jack-up drilling rigs are designed using the working(or allowable) stress design (WSD) method. Recently, classifications have been developed for specific regulations based on the load and resistance factor design (LRFD) method, which emphasises the reliability of the methods. This statistical method utilises the concept of limit state design and uses factored loads and resistance factors to account for uncertainly in the loads and computed strength of the leg components in a jack-up drilling rig. The key differences between the LRFD method and the WSD method must be identified to enable appropriate use of the LRFD method for designing jack-up rigs. Therefore, the aim of this study is to compare and quantitatively investigate the differences between actual jack-up lattice leg structures, which are designed by the WSD and LRFD methods, and subject to different environmental load-to-dead-load ratios, thereby delineating the load-to-capacity ratios of rigs designed using theses methods under these different enviromental conditions. The comparative results are significantly advantageous in the leg design of jack-up rigs, and determine that the jack-up rigs designed using the WSD and LRFD methods with UC values differ by approximately 31 % with respect to the API-RP code basis. It can be observed that the LRFD design method is more advantageous to structure optimization compared to the WSD method.

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

A Study on the Devitrification of Container Glass with the Amounts of Cullet (유리 용기 생산시 Cullet의 사용에 관한 연구)

  • Noh, Kwang-Hong;Kim, Jong-Ock;Kim, Taik-Nam;Lim, Dae-Young;Park, Won-Kyu;Lee, Chae-Hyun
    • The Journal of Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.199-205
    • /
    • 1998
  • Cullet Quality Control in auto glass bottle factory is the most important in recent days because of the increasing cost of materials in glass bottle. Since the composition of plate glass cullet is similar, the cullet quality using plate cullet in glass bottle factory is easily controlled. In addition to this, the price of plate glass cullet is so low that the cost reduction can be achieved. If the ratio of plate glass cullet and gush is over 25%, the liquidity of glass water become worse, which is caused by different compositions and viscosity of the components. As a results, Furnace bottom temperature becomes low and glass water becomes inhomogeneous. Thus production efficiency of glass bottle becomes low because of increasing devitrification in Dead Corner part in glass melting furnace. Three experimental methods – (1) increasing melting temperature, (2) using Booster, (3) using bubbler – were performed to increase the furnace bottom temperature and glass water homogeneity. The amounts of plate glass cullet was able to increase up to 90%, 70% and 60% without any devitrification using booster, bubbler and the method of glass melting temperature increase from $1480^{\circ}C$ to $1560^{\circ}C$ respectively. It is not possible to increase the glass melting temperature without the reduction of furnace operation time and the increase of fuel cost. The booster process has disadvantage of much electric energy consumption. Since the bubbler process uses physical convection of melting glass based on compression air, the homogeneity of molten glass is not so good as that of booster process but it can reduce the cost of glass bottle.

  • PDF

Determination of optimum gamma ray range for radiation mutagenesis and hormesis in quinoa (Chenopodium quinoa Willd.)

  • Park, Chan Young;Song, Seon Hwa;Sin, Jong Mu;Lee, Hyeon Young;Kim, Jin Baek;Shim, Sang In
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.240-240
    • /
    • 2017
  • Quinoa (Chenopodium quinoa Willd.) is one of the ancient crops cultivated in the Andes region at an altitude of 3,500-4000m in Chile and Bolivia from 5000 BC. It contains a large amount of protein, minerals and vitamins in comparison with other crops. The cultivation area has been increasing worldwide because of its excellent resistance to various abiotic stress such as salinity, drought and low temperature. ${\gamma}$-Ray radiation of high dose is often used as a tool to induce mutations in plant breeding, but it has a deleterious effect on organisms. However, the radiation may have a positive stimulatory effect of 'hormesis' in the low dose range. This experiment was carried out to investigate the optimum dose range for creating the quinoa genetic resources and to investigate the hormesis effect at low dose on the quinoa. This experiment was performed for 120 days from November, 2016 to February, 2017 in the greenhouse of Gyeongsang National University. ${\gamma}$-Ray radiation was irradiated to seeds at 0 Gy, 50 Gy, 100 Gy, 200 Gy, 300 Gy, 400 Gy, 600 Gy, 800 Gy and 1000 Gy for 8 hours. (50 Gy) using the low level radiation facility ($Co^{60}$) of Cooperative Research Institute of Radiation Research Institute, KAERI. Fifty seeds were placed on each petri dish lined with wet filter paper and germination rate was measured at a time interval of 2 hours for 40 hrs. The length of the root length was measured one week after germination. Each treatment was carried out in 3 replicates. The growth of seedlings were investigated for 10 days after transplanting of 30 day-old seedlings. The plant height, NDVI, SPAD, Fv/Fm, and panicle weight were measured. The germination rate was highest at 50Gy and 0Gy and the rate of seeds treated with 400Gy or higher rate decreased to 25% of the seeds treated with 50Gy. The emergence rate of seedling in pot experiment was higher at the dose of 200 Gy, 300 Gy and 400 Gy than at 0 and 50Gy. However, the rate was lower at strong radiation higher than 600Gy at which $1^{st}$ leaf was not expanded fully and dead due to extreme overgrowth at 44 days after treatment (DAT). The highest value of panicle weight was observed at 50Gy (6.15g) and 100Gy (5.57g). On the other hand, the weight at high irradiated dose of 300Gy and 400Gy was decreased by about 55% compared to low dose (50 Gy). NDVI measurement also showed the highest value at 50 Gy as the growth progressed. SPAD was the highest at 400 Gy and showed positive correlation with irradiation dose except 0 Gy. Fv/Fm was high at 50 Gy up to 30 DAT and no difference between treatments was observed except for 400 Gy from 44 DAT. The plant height was the highest in 50Gy during the growing period and was higher in the order of 50Dy, 100Gy, 0Gy, 200Gy, 300Gy and 400Gy in 88 DAT. In this experiment, the optimal radiation dose for hormesis was 50Gy and 100Gy, and the optimal radiation dose for mutagenesis seems to be 400 Gy.

  • PDF

Comparison of Electrical Signal Properties about Top Electrode Size on Photoconductor Film (광도전체 필름 상부 전극크기에 따른 전기적 신호 특성 비교)

  • Kang, Sang-Sik;Jung, Bong-Jae;Noh, Si-Cheul;Cho, Chang-Hoon;Yoon, Ju-Sun;Jeon, Sung-Pyo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.93-96
    • /
    • 2011
  • Currently, the development of direct conversion radiation detector using photoconductor materials is progressing in widely. Among of theses photoconductor materials, mercuric iodide compound than amorphous selenium has excellent absorption and sensitivity of high energy radiation. Also, the detection efficiency of signal generated in photoconductor film varies by electric filed and geometric distribution according to top-bottom electrode size. Therefore, in this work, the x-ray detection characteristics are investigated about the size of top electrode in $HgI_2$ photoconductor film. For sample fabrication, to solve the problem that is difficult to make a large area film, we used the spatial paste screen-print method. And the sample thickness is $150{\mu}m$ and an film area size is $3cm{\times}3cm$ on ITO-coated glass substrate. ITO(Indium-Tin-Oxide) electrode was used as top electrode using a magnetron sputtering system and each area is $3cm{\times}3cm$, $2cm{\times}2cm$ and $1cm{\times}1cm$. From experimental measurement, the dark current, sensitivity and SNR of the $HgI_2$ film are obtained from I-V test. From the experimental results, it shows that the sensitivity increases in accordance with the area of the electrode but the SNR is decreased because of the high dark current. Therefore, the optimized size of electrode is importance for the development of photoconductor based x-ray imaging detector.