• Title/Summary/Keyword: Co-contamination

Search Result 451, Processing Time 0.028 seconds

Seismic Influence on Subsea Pipeline Stresses

  • Choi, Byoung-Yeol;Lee, Sang-Gil;Kim, Jin-Kwang;Oh, Jin-Soo
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.3 no.1
    • /
    • pp.1-14
    • /
    • 2017
  • The safety analysis of an earthquake is carried out during the operation of a subsea pipeline and an onshore pipeline. Several cases are proposed for consideration. In the case of a buried pipeline, permanent ground deformation by the earthquake and an increase of internal pressure by the acceleration of the earthquake should be considered. In the case of a subsea pipeline, a bending moment is caused by liquefaction of the backfill material on a trenched seabed, etc., which results in a high bending moment of the buried pipeline. The bending moment causes the collapse of the subsea pipeline or a leak of crude oil or gas, which results in economic loss due to enormous environmental contamination and social economic loss owing to operation functional failure. Thus, in order to prevent economic loss and operation loss, structurally sensitive design with regard to seismic characteristics must be performed in the buried pipeline in advance, and the negative impact on the buried pipeline must be minimized by conducting a thorough analysis on the seabed and backfilling material selection. Moreover, it is proposed to consider the selection of material properties for the buried pipeline. A more economical review is also required for detailed study.

A Study on the Calcium Bioavailability of Eggshell Powder in the Growing Rats (난각 칼슘의 생체 이용성에 관한 연구)

  • 장순옥
    • Journal of Nutrition and Health
    • /
    • v.36 no.7
    • /
    • pp.684-690
    • /
    • 2003
  • This study has investigated the bioavailability of calcium in eggshell powder (ESP) for the purpose of reutilizing eggshells as the calcium source. The experiment was designed 2 ${\times}$ 2 factorial method with two sources, CaCO$_3$ and ESP, and two levels, 0.2% and 0.4% calcium. Weanling SD rats were assigned randomly to one of 4 groups and provided by one of the isocaloric, 20% casein based 4 different experimental diets for 4weeks. Deionized water was given and environment was kept from any contamination of minerals. The body weight, diet intake, feed efficiency ratio (FER), bone growth, Ca contents of bones, and apparent absorption were measured. FER (0.38 - 0.40) and kidney weight were not different among groups and the weight and length, Ca content, strength of two bones Tibia and Femur were not affected by Ca sources except Femur Ca content. Ca content of Femur was greater in ESP groups than that of CaCO$_3$ groups. The body weight gain, bone growth, the Ca contents and strength of bones were significantly greater in 0.4% calcium groups suggesting 0.2% calcium is not sufficient for the optimum growth in the growing rats. These results indicate that ESP be a proper Ca source comparable or superior to CaCO$_3$. However the apparent absorption rate of final 3 days of feeding did not support the observed results showing lower rate in ESP than CaCO$_3$ groups. Further study be needed in the absorption aspect.

A Study on the amount of Co gas in the kitchen related to facility enviromental condition and fuel management (부엌공기 중에 함유되어 있는 가스량과 부엌 구조시설 연료관리와의 관계에 대한 연구)

  • 장명욱
    • Journal of the Korean Home Economics Association
    • /
    • v.8 no.1
    • /
    • pp.146-158
    • /
    • 1970
  • It is a matter of amazing to realize that contamination of air by fuel gas in recent daily life at home directly effects to health of Korean housewives. A study in finding the status and the amount of co gas in the kitchen was con-ductedrelating the size of kitchen, door of exit, ventilation window, constraction of built in-brick stove (Boo Tu Mack), fuel management, in order to extend beneficial and improved management of housing. From the result of study, it was pointed out that constractional improvement of built-in-brick stove, heating floor (Ondol), timny, and ventilation window would been emergently needed. Demonstration studies were obtained in finding differences of the amount of co gas respectively in cooking time as 50-55ppm, and in not cooking time as 50-80p,p,m in the kitchen both, original and improved. Definite differences were found depend upon the condition with, without, or direction of the ventilation window. In addition to all above results, significant influence on gas pulling power of Ondol tunnel was shown. Many houses of Apartment house for have middle and low income groups been recognized so poor for health as indicated over 100ppm of co gas if window were not opened because of poor ventilation and weak gas pulling power of Ondol tunnel.

  • PDF

Preprocess of GaAs Epitaxial Layer Growth by MBE (MBE에 의한 GaAs 에피층 성장을 위한 사진처리 과정)

  • Kang, Tae Won;Lee, Jae Jin;Hong, Chi You;Kim, Jin Whang;Chung, Kwan Soo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.2
    • /
    • pp.243-248
    • /
    • 1986
  • The impurities in As and Ga sources and the contamination of the GaAs substrate prior to growing of MBE GaAs epitaxial layer have been investigated using RHEED, AES and RGA methods. The as source was contaminated by H2O, CO, CO2 and AsO, and the Ga source was contaminated by H2, H2O, CO and CO2. These contaminants could easily be removed by prebaking the source. On the other hand, GaAs substrate was contaminated principally carbon and oxygen. The oxygen could easily be removed by heating the substrate above 480\ulcorner, and the carbon could also be reduced by sputtering the substrate with 1ke V Ar+. The chemically etched substrate surface prior to growing the layer was rough, but it was made to be smooth and clean by heating it above 530 \ulcorner.

  • PDF

Review of Aging Management for Concrete Silo Dry Storage Systems

  • Donghee Lee;Sunghwan Chung;Yongdeog Kim;Taehyung Na
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.4
    • /
    • pp.531-541
    • /
    • 2023
  • The Wolsong Nuclear Power Plant (NPP) operates an on-site spent fuel dry storage facility using concrete silo and vertical module systems. This facility must be safely maintained until the spent nuclear fuel (SNF) is transferred to an external interim or final disposal facility, aligning with national policies on spent nuclear fuel management. The concrete silo system, operational since 1992, requires an aging management review for its long-term operation and potential license renewal. This involves comparing aging management programs of different dry storage systems against the U.S. NRC's guidelines for license renewal of spent nuclear fuel dry storage facilities and the U.S. DOE's program for long-term storage. Based on this comparison, a specific aging management program for the silo system was developed. Furthermore, the facility's current practices-periodic checks of surface dose rate, contamination, weld integrity, leakage, surface and groundwater, cumulative dose, and concrete structure-were evaluated for their suitability in managing the silo system's aging. Based on this review, several improvements were proposed.

Microbiological Contamination in Office Buildings by Work Space Structure (사무공간 구조에 따른 실내공기 중 생물학적 오염분포 특성)

  • Won, Dong-Hwan;Huh, Eun-Hae;Jeong, Ho-Chul;Moon, Kyong-Whan
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.3
    • /
    • pp.213-222
    • /
    • 2012
  • Objectives: This study was undertaken in order to evaluate by work space zoning and structure the concentrations of biological contaminants in the indoor air of domestic office buildings. Methods: Air samples were collected in the office spaces of 15 office buildings in Seoul from June 28 to July 28, 2011. Prior to the sampling, each office was classified into 'open-plan office', 'cellular office' and 'mixed office' according to the work space zoning. To evaluate the biological contamination of indoor air, total suspended bacteria (TSB), Gram positive bacteria (GPB), Staphylococcus aureus (S.A), Methicillin-resistant Staphylococcus aureus (MRSA), Gram negative bacteria (GNB) and fungi were investigated. During the sampling, temperature, relative humidity and carbon dioxide ($CO_2$) were measured. Results: The TSB concentrations ($GM{\pm}GSD$) were $452({\pm}1.3)cfu/m^3$ in open-plan offices, $366({\pm}1.3)cfu/m^3$ in cellular offices and $287({\pm}1.5)cfu/m^3$ in mixed offices, and there were significant differences between the three groups (p<0.05). The highest concentrations ($GM{\pm}GSD$) of fungi were found in the indoor air of cellular offices $128({\pm}1.0)cfu/m^3$, which was at least three times higher than the concentrations in mixed offices $43({\pm}1.0)cfu/m^3$ (p<0.05). Conclusions: Microbiological contamination in the indoor air of office buildings by work space structure was the highest with the open-plan office layout which includes no high walls or doors separating the occupants.

A Review on Nitrate Source Identification using Isotope Analysis (동위원소분석을 이용한 질산염의 오염원 추적에 대한 고찰)

  • Jeen, Sung-Wook;Lee, Hwan;Kim, Rak-Hyeon;Jeong, Hoon Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.1
    • /
    • pp.1-12
    • /
    • 2017
  • Nitrate ($NO_3^-$), a common surface water and groundwater pollutant, poses a serious environmental problem in regions with intensive agricultural activities and dense population. It is thus important to identify the source of nitrate contamination to better manage water quality. Due to the distinct isotope compositions of nitrate among different origins, the dual isotope analysis (${\delta}^{15}N$ and ${\delta}^{18}O$) of nitrate has been widely applied to track contamination sources. This paper provided the underlying backgrounds in the isotope analysis of nitrate, which included typical ranges of ${\delta}^{15}N$ and ${\delta}^{18}O$ from various nitrate sources, isotope fractionation, the analytical methods used to concentrate nitrate from samples, and the potential limitations of the dual isotope analysis along with the resolutions. To enhance the applicability of the dual isotope analysis as well as increase the ability to interpret field data, this paper also introduced several case studies. Furthermore, other environmental tracers including ${\delta}^{11}B$ and $Cl^-/Br^-$ ratios were discussed to accompany the dual isotope analysis for better assignment of contamination sources even when microbial transformation of nitrate and/or mixing between contaminant plumes occur.

Evaluation of sewage-derived organic matter using fecal sterols in the sediments from Ulsan Bay and adjacent areas (Fecal sterol을 이용한 울산만과 주변해역 퇴적물내 하수기인 유기물 평가)

  • Choi Minkyu;Choi Hee-Gu;Kim Sang-Soo;Moon Hyo-Bang
    • Journal of Environmental Science International
    • /
    • v.14 no.1
    • /
    • pp.23-32
    • /
    • 2005
  • Surface sediments (0$\~$4 cm) were sampled at 40 stations from Ulsan Bay and its adjacent areas of Korea, to evaluate the contamination by sewage-derived organic matters using fecal sterols. Some sterols were quantified by gas chromatography coupled to mass spectrometry (GC/MS). Total concentrations of eight sterols (co­prostanol, cholesterol, cholestanol, epicholestanol, epicoprostanol, ${\beta}-sitosterol,$ brassicasterol, and stigmasterol) in the sediments from Ulsan Bay and its vicinity varied from 929 to 23,444 ng/g dry weight. The most predom­inant sterols were cholesterol and coprostanol, accounting for $33\~72{\%}$ of total sterols. The concentration of coprostanol known as the indicator of human feces ranged from 141 to 8,257 ng/g dry weight. In particular, the coprostanol concentrations in the sediments from Jansaengpo Harbor and Taehwa River exceeded the value of 1,000 ng/g dry weight, suggesting that these areas could be considered as the hot-spot zones by municipal sewage contamination. Some molecular indices and multivariate data analysis were used to assess the origin of these sterols in the sediments. Results showed that the major routes of sewage contamination in Ulsan Bay and its vicinity were the input through Jansaengpo Harbor and Taehwa River.

Heavy metal assessment of marine sediment in selected coastal districts of the Western Region, Ghana

  • Kuranchie-Mensah, Harriet;Osei, Juliet;Atiemo, Sampson M.;Nyarko, Benjamin J.B.;Osae, Shiloh K.;Laar, Cynthia;Ackah, Michael;Buah-Kwofie, Archibold;Blankson-Arthur, Sara;Adeti, Prince J.
    • Advances in environmental research
    • /
    • v.2 no.2
    • /
    • pp.155-166
    • /
    • 2013
  • A preliminary investigation to establish the status of contamination of trace metals in the Western coast of Ghana was conducted prior to the commercial production of crude oil in the area. The study revealed the presence of heavy metals such as Pb (4.00-79.64 mg/kg), As (8.81-236 mg/kg), Cu (12.86-108.06 mg/kg), V (28.07-953.32 mg/kg), Zn (7.08-264.25 mg/kg), Cr (101.69-1366.62 mg/kg), Ni (42.41-451.43 mg/kg), Mn (16.77-1890.45mg/kg), Br (7.66-142.78 mg/kg), Ti (542.03-19960 mg/kg) and Fe (7472.88-97120 mg/kg) at six sites sampled along the coast. With the exception of Ti and Fe which showed no variation in metal concentration, the rest of the metals varied significantly among the sampled locations. Potential ecological risk of metals particularly of Co, As and Br which exhibited extreme enrichment of the sediments indicates considerable metal pollution in the studied areas. The degree of contamination is of particular concern especially to benthic biota that inhabit this environment for survival.

An Experimental Study on Energy Reduction of an Exhaust Air Heat Recovery Type Outdoor Air Conditioning System for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 배기 열회수식 외기공조시스템의 에너지절감에 관한 실험적 연구)

  • Song, Gen-Soo;Yoo, Kyung-Hoon;Kang, Shin-Young;Son, Seung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.5
    • /
    • pp.273-281
    • /
    • 2009
  • In recent semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems represents about 45% of the total air conditioning load required to maintain a clean room environment. Meanwhile, there is a large amount of exhaust air from a clean room. From an energy conservation point of view, heat recovery from the exhaust air is therefore useful for reducing the outdoor air conditioning load for a clean room. In the present work, an energy-efficient outdoor air conditioning system was proposed to reduce the outdoor air conditioning load by utilizing an air washer to recover heat from the exhaust air. The proposed outdoor air conditioning system consisted mainly of a preheating coil, an air washer, two stage cooling coils, a reheating coil, a humidifier and two heat recovery cooling coils inserted into the air washer and connected to a wet scrubber. It was shown from the lab-scale experiment with outdoor air flow of $1,000\;m^3/h$ that the proposed system was more energy-efficient for the summer and winter operations than an outdoor air conditioning system with a simple air washer.