• 제목/요약/키워드: Co-base alloy

검색결과 109건 처리시간 0.033초

Base metal Alloy에 관한 고찰(考察) (Study on Base metal Alloy)

  • 성환경
    • 대한치과기공학회지
    • /
    • 제7권1호
    • /
    • pp.53-59
    • /
    • 1985
  • This paper aims to examine baes metal alloy in all its aspects - the roles of elements, the content of every element according to uses, characters, laboratory technique methods and the kind of artificial base metal alloy registered in A.D.A. Specification. The results are as follows; 1. Base metal alloy is used widely bacaues it is rather cheap, but it should be handled appropriately in operating because its quality is bad. 2. Classifying base metal alloy, it is classified into Co-Cr alloy, Ni-Cr alloy, and Ni-Cr-Co alloy according to element, it is classified into partial denture alloy, surgical alloy and crown & bridge alloy according to use. 3. Among elements of base metal alloy, Bellium lowers the melting point of the alloy and increases the strength, but the amount should be limited when it is used because it destroys the organization of a living body. 4. The investments for base metal alloy are ethyl silcate bonded investment and phosphate bonded investment which endure well at high burn out temperature. 5. A.D.A specification No.14 in Kore contains Niranium, Nobilium, regalloy, Ticonium and Vitallium.

  • PDF

Fe-29%Ni-17%Co 저열팽창 합금의 피로 특성에 미치는 알파상의 영향 (Effects of Alpha Phase on the Fatigue Properties of Fe-29%Ni-17%Co Low Thermal Expansion Alloy)

  • 김민종;권진한;조규상;이기안
    • 한국재료학회지
    • /
    • 제24권9호
    • /
    • pp.481-487
    • /
    • 2014
  • The effect of alpha phase on the fatigue properties of Fe-29%Ni-17%Co low thermal expansion alloy was investigated. Two kinds of alloys (Base alloy and Alpha alloy) were prepared by controlling the minimal alloy composition. Microstructure observation, tensile, high-cycle fatigue, and low-cycle fatigue results were measured in this study. The Base alloy microstructure showed typical austenite ${\gamma}$ phase. Alpha alloy represented the dispersed phase in the austenite ${\gamma}$ matrix. As a result of tensile testing, Alpha alloy was found to have higher strengths (Y.S. & T.S.) and lower elongation compared to those of the Base alloy. High cycle fatigue results showed that Alpha alloy had a higher fatigue limit (360MPa) than that (330MPa) of the Base alloy. The Alpha alloy exhibited the superior high cycle fatigue property in all of the fatigue stress conditions. SEM fractography results showed that the alpha phase could act to effectively retard both fatigue crack initiation and crack propagation. In the case of low-cycle fatigue, the Base alloy had longer fatigue life in the high plastic strain amplitude region and the Alpha alloy showed better fatigue property only in the low plastic strain amplitude region. The fatigue deformation behavior of the Fe-29%Ni-17%Co alloy was also discussed as related with its microstructure.

Thermocycling이 Cobalt-Chromium 합금과 의치상 레진의 결합강도에 미치는 영향 (THE EFFECTS OF THERMOCYCLING ON THE BOND STRENGTH BETWEEN COBALT-CHROMIUM ALLOY AND DENTURE BASE RESIN)

  • 이수연;방몽숙
    • 대한치과보철학회지
    • /
    • 제38권1호
    • /
    • pp.38-49
    • /
    • 2000
  • The purpose of this study was to evaluate the effects of thermocycling on the shear bond strength of Co-Cr alloy to denture base resin. PMMA denture base resin such as heat-cured $Vertex-RS^{(R)}$, self-cured $Vertex-SC^{(R)}$ and 4-META denture base resin such as heat-cured $Meta-Dent^{(R)}$, self-cured $Meta-Fast^{(R)}$ was bonded to Co-Cr alloy. Samples were divided into 3 groups : no thermocycling group as control, thermocycling between $5^{\circ}C\;and\;55^{\circ}C$ with 15 second dwell time as group 1, thermocycling with 1 minute dwell time as group 2. The shear bond strength was measured and the interface between metal and resin was observed by SEM. The results were as follows. 1. The shear bond strength decreased significantly according to thermocycling and dwell time(P<0.001). 2. The bond strength of Co-Cr alloy and 4-META denture base resin was significantly higher than that of Co-Cr alloy and PMMA denture base resin(P<0.001) 3. In SEM, there was no gap in control group, but there was much and large gap in group 1, 2. The longer dwell times, the lower bond strength. PMMA denture base resin had more gap than 4-META denture base resin in the interface. These results revealed that thermocycling decreased the bond strength between Co-Cr alloy and denture base resin and dwell time of thermocycling changed the effect of thermocycling. The results suggested that oral temperature change affect the bond strength of prosthesis.

  • PDF

A Study on the Surface Modification of the Super Alloy by Plasma Transferred Arc Overlay Welding Method

  • Kim, Young-Sik;Lim, Chang-Hoon;Hwang, Won-Seok;Choi, Young-Gook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권7호
    • /
    • pp.852-856
    • /
    • 2007
  • The Plasma Transferred Arc(PTA) overlay welding method is lately introduced as one of the most useful surface overlay method of the engine component. In this paper, the overlay welding method on the Nimonic super alloy was established by the PTA overlay welding process using the same super alloy powder. The characteristics of the Co-base and Ni-base super alloy overlay layers were investigated through the metallurgical, abrasive and cavitation erosion test. The abrasive and cavitation characteristics were investigated at room and high temperature.

Ni 계 초내열합금의 PTA 오버레이 층 특성에 관한 연구 (A Study on the Characteristics of the Ni base Super Alloy Overlay Layer by Plasma Transferred Arc (PTA) Method)

  • 김영식;최영국;이광렬
    • Journal of Welding and Joining
    • /
    • 제24권3호
    • /
    • pp.49-54
    • /
    • 2006
  • The Plasma Transferred Arc (PTA) overlaying method is lately introduced as one of the most useful surface modification method of the engine component. In this paper, the characteristics of the Co-base and Ni-base super alloy overlay layers by PTA method were investigated through the metallurgical, abrasive and cavitation erosion test. Experimental results showed that the abrasive wear resistance of the Co-base Stellite 6 overlayer was the most superior and followed in order of Nimonic 80A, Inconel 625 and Inconel 718. However, the cavitation erosion characteristic of the Stellite 6 overlayer was the most inferior and it was better in order of Inconel 625, Inconel 718 and Nimonic 80A.

베릴륨이 함유되지 않은 니켈-크롬 합금 코어와 코발트-크롬 합금 코어의 적합도 비교평가 (Comparison of the marginal and internal fit of cores fabricated by Ni-Cr alloy(non-beryllium) and Co-Cr alloy)

  • 김기백;김재홍;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.353-359
    • /
    • 2012
  • Purpose: The aim of this study measured and compared the marginal and internal fit of metal cores with two base metal alloy (Ni-Cr alloy(non-beryllium), Co-Cr alloy). Methods: Maxillary right first molar abutment fabricated by titanium was prepared for this study. Impressions(10ea) were made from titanium model, and study models were poured with improved dental stone. Wax cores of twenty were prepared for burn-out and casting. Ten wax cores cast Ni-Cr alloy(non-Be), and finally ten cast Co-Cr alloy. Marginal and internal fit of cores was evaluated using silicone replica technique and digital microscope(x160). The data were statistically analyzed with the independent samples t-test (${\alpha}$ <.05). Results: Mean(standard deviation, SD) marginal and internal fit total size of Ni-Cr alloy(non-Be) group was $73.3(14.4){\mu}m$ and of Co-Cr alloy group $65.6(17.4){\mu}m$. The marginal and internal fit total size of Ni-Cr alloy group(non-Be) was statistically significantly greater than that of Co-Cr alloy group (P=.004). Conclusion: Co-Cr alloy cores in this study had a better marginal fit than Ni-Cr alloy(non-Be) cores.

질화 지르코늄 코팅이 코발트 크롬 합금과 타이타늄 합금에서 의치상 레진과의 전단결합강도에 미치는 영향 (The effect of Zirconium Nitride coating on shear bond strength with denture base resin in Co-Cr alloy and titanium alloy)

  • 박찬;이경훈;임현필
    • 구강회복응용과학지
    • /
    • 제32권3호
    • /
    • pp.194-201
    • /
    • 2016
  • 목적: 본 연구는 Co-Cr, Ti-6Al-4V 합금에 Zirconium Nitride (이하 ZrN) 적용 시, 의치상 레진과의 접착력을 비교하는 것이다. 연구 재료 및 방법: Co-Cr, Ti-6Al-4V 디스크(직경 10 mm, 두께 2.5 mm)를 각각 14개씩 제작하였고, ZrN 코팅에 따라 2개의 그룹으로 나누었다. Primer로 시편 전처리 후, 의치상 레진(직경 6 mm, 두께 5 mm)을 부착하였다. 표면 측정기를 이용하여 시편의 거칠기를 측정한 후, 만능 시험기를 이용하여 전단결합강도를 측정하였으며, 이원분산분석으로 통계 분석하였다. 시편 표면과 파절 양상을 주사전자현미경을 이용하여 관찰하였다. 결과: ZrN을 코팅한 시편에서 유의하게 높은 표면 거칠기를 나타내었고(P < 0.05), 전단결합강도는 낮았다(P < 0.001). ZrN 코팅 시편에서는 혼합성 파절과 부착성 파절이 함께 나타났다. 결론: Co-Cr, Ti-6Al-4V 합금에서 ZrN 코팅 처리는 의치상 레진과의 결합력을 약화시켰다.

Ni계 및 Co계 합금 PTA 오버레이용접층의 마모거동에 관한 연구 (Wear Behavior of Plasma Transferred Arc Deposited Layers for Ni - and Co - base Alloy)

  • 윤병현;이창희;김형준
    • Journal of Welding and Joining
    • /
    • 제19권5호
    • /
    • pp.540-547
    • /
    • 2001
  • This study has evaluated the wear behavior of PTA (Plasma Transferred Arc) Inconel 625 and Stellite 6 overlays on Nimonic 80A substrate. Nimonic 80A alloy was also included for comparison. In order to evaluate the wear performance, three-body abrasive wear test and pin-on-disk dry sliding wear test were performed. Microstructural development during the solidification of deposits is also discussed. Wear test results show that the wear rate of Stellite 6 deposit is lower than that of Inconel 625 deposit and Nimonic 80A. The sliding wear resistance of overlay deposits follows a similar trend to the abrasive wear resistance, but for Nimonic 80A. The main wear mechanisms were abrasive wear for Inconel 625 deposit, adhesive wear and delamination for Stellite 6 deposit in pin-on-disk dry sliding wear test and ploughing in three-body abrasive wear test. Cross sectional examinations of the worn surface of pin specimens after pin-on-disk dry sliding wear test implies that the plastic deformation near worn surface has occurred during the wear testing.

  • PDF

Co-Re-based alloys a new class of material for gas turbine applications at very high temperatures

  • Mukherji, D.;Rosler, J.;Wehrs, J.;Eckerlebe, H.;Gilles, R.
    • Advances in materials Research
    • /
    • 제1권3호
    • /
    • pp.205-219
    • /
    • 2012
  • Co-Re alloy development is prompted by the search for new materials for future gas turbines which can be used at temperatures considerably higher than the present day single crystal Ni-based superalloys. The Co-Re based alloys are designed to have very high melting range. Although Co-alloys are used in gas turbine applications today, the Co-Re system was never exploited for structural applications and basic knowledge on the system is lacking. The alloy development strategy therefore is based on studying alloying additions on simple model alloy compositions of ternary and quaternary base. Various strengthening possibilities have been explored and precipitation hardening through fine dispersion of MC type carbides was found to be a promising route. In the early stages of the development we are mainly dealing with polycrystalline alloys and therefore the grain boundary embrittlement needed to be addressed and boron addition was considered for improving the ductility. In this paper recent results on the effect of boron on the strength and ductility and the stability of the fine structure of the strengthening TaC precipitates are presented. In the beginning the alloy development strategy is briefly discussed.

코발트-크롬 합금의 표면처리에 따른 열중합형 의치상용 레진과의 전단결합강도 (SHEAR BOND STRENGTH OF HEAT-CURED DENTURE BASE RESIN TO SURFACE TREATED CO-CR ALLOY WITH DIFFERENT METHODS)

  • 이상훈;황선홍;문홍석;이근우;심준성
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.216-227
    • /
    • 2007
  • Statement of problem: For the long-term success of removable partial dentures, the bonding between metal framework and denture base resin is one of the important factors. To improve bonding between those, macro-mechanical retentive form that is included metal framework design has been generally used. However it has been known that sealing at the interface between metal framework and denture base resin is very weak, because this method uses mechanical bonding. Purpose: Many studies has been made to find a simple method which induces chemical bond, now various bonding system is applied to clinic. In this experiment, shear bond strengths of heat-cured denture base resin to the surface-treated Co-Cr alloy were measured before and after thermocycling. Chemically treated groups with Alloy $Primer^{TM}$, Super-Bond $C&B^{TM}$, and tribochemically treated group with $Rocatec^{TM}$ system were compared to the beadtreated control group. The data were analyzed with two-way ANOVA. Result: 1. Shear bond strength of bead-treated group is highest, and Alloy $Primer^{TM}$ treated group, Super-Bond $C&B^{TM}$ treated group, RocatecTM system treated group were followed. Statistically significant differences were found in each treated group(p<0.05). 2. Surface treatment and thermocycling affected shear bond strength(p<0.05), however there was no interaction between two factors(p>0.05). 3. Shear bond strengths of bead-treated group and Alloy $Primer^{TM}$ treated group showed no statistically significant difference before and after thermocycling(p>0.05), and those of Super-Bond $C&B^{TM}$ treated group and $Rocatec^{TM}$ system treated group showed statistically significant difference after thermocycling(p<0.05).