Alloy 617계 산화물 분산강화(ODS) 합금의 제조와 인장특성 (Fabrication and Tensile Properties of Alloy 617 base ODS Alloy)

  • 민형기;강석훈;김태규;한창희;김도향;장진성
    • 한국분말재료학회지
    • /
    • 제18권6호
    • /
    • pp.482-487
    • /
    • 2011
  • Alloy 617, Ni-22Cr-12Co-9Mo base oxide dispersion strengthened alloy was fabricated by using mechanical alloying, hot isostatic pressing and hot rolling. Uniaxial tensile tests were performed at room temperature and at $700^{\circ}C$. Compared with the conventional Alloy 617, ODS alloy showed much higher yield strength and tensile strength, but lower elongation. Fracture surfaces of the tensile tested specimens were investigated in order to find out the mechanism of fracture mode at each test temperature. Grain adjustment during tensile deformation was analyzed by electron backscattered diffraction mapping, inverse pole figures and TEM observation.

PREDICTION OF MARTENSITE START TEMPERATURES OF HIGHLY ALLOYED STEELS

  • SEOK-JAE LEE;MINSU JUNG
    • Archives of Metallurgy and Materials
    • /
    • 제66권1호
    • /
    • pp.107-111
    • /
    • 2021
  • We propose an empirical equation to predict the martensite start temperatures of highly alloyed steels containing more than 3 wt.% of Ni or Cr or 2 wt.% of Mo, W, or Co. The martensite start temperature calculated by the proposed equation was in good agreement with experimental data owing to not only the derivation from experimental data of alloy steels with a wide range of chemical compositions but also the interaction term between carbon and carbide-forming alloying elements.

Grain Refinement를 통한 Mg-Ca-Zn합금의 기계적 특성 및 부식 특성 향상 (Improvement of Mechanical and Corrosion Properties of Mg-Ca-Zn Alloy by Grain Refinement)

  • 김대한;최종민;임현규
    • 한국산학기술학회논문지
    • /
    • 제18권9호
    • /
    • pp.418-424
    • /
    • 2017
  • 마그네슘은 다른 금속들에 비해 비강도가 높으며, 우수한 진동 흡수능, 전자파 차폐성 등으로 산업 전반에 많이 활용되고 있다. 예를 들면, 자동차 시트 프레임, 실린더 헤드 등 자동차 부품으로도 사용되며 노트북 케이스, 핸드폰 케이스 등의 전자제품에도 널리 사용되고 있다. 또한 신체의 뼈가 금이 가거나 부서졌을 경우, 그 손상된 뼈의 치료를 보조하기 위해 사용되는 골 접합용 임플란트 재료로 각광받고 있다. 현재 임플란트 재료로는 Ti alloy, Stainless steel, Co-Cr-Mo alloy등이 사용되어 지고, Mg 합금은 연구단계에 머물러 있다. 현재 골접합용 임플란트 재료의 문제점으로는 한번 접합 수술 후에 회복이 되면 이것을 제거하기 위한 수술을 또 해야 한다는 점이 있다. 하지만 마그네슘은 현재 재료와 비교하여 충분한 강도를 실현 할 수 있으며, 일정시간 후 자체적으로 분해되고 인체에 무해한 원소기 때문에 연구가 진행되고 있다. 그러나 순수 Mg으로는 충분한 강도와 내식성을 가질 수 없기 때문에 합금원소를 첨가하여 Mg 합금을 설계한다. 본 논문에서는 마그네슘에 인체에 무해한 Ca, Zn를 첨가하여 합금을 설계하였고, 추가적으로 강도와 내식성을 향상시키기 위해서 Grain refiner로서 Sr을 소량 첨가하여 최종 합금을 설계하였다. Sr은 방사선 원소는 인체에 유해하지만, 그 외 천연 Sr 원소는 인체에 무해하다. 이렇게 제조된 합금을 광학현미경, 주사전자현미경을 통해 미세조직분석을 수행하고, 인장시험, 동전위 분극 시험, 침지시험을 통해 기계적 특성 및 부식특성을 평가하였다. 결론적으로, Sr 첨가에 의해 조직이 미세해졌으며, 기계적 특성 및 내식성이 향성된 것을 확인 할 수 있었다.

A Solution for Diffusion Equations and the Distribution of Alloying Elements in Sintered Alloys

  • Wang, Chonglin
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.72-73
    • /
    • 2006
  • The error function can be calculated based on the Simpson method through a subroutine program. An integration program by FORTRAN language was made for diffusion equations of extended source with infinite extent and limited extent. The results on some alloying elements such as C, Co, Cr, Mn, Mo, Ni and V's diffusion in iron, showed the diffusion distance for Ni and Mo can only be $1{\sim}3\;{\mu}m$ and more distance for Co at common sintering temperature of $1120^{\circ}C$. To refine the particle size of the added elements down to a scale of micrometers is an effective way to get homogeneous distribution.

  • PDF

생체용 Ti-Zr-Pd계 합금의 양극분극특성 (Anodic Polarization Properties of Ti-Zr-Pd Based Alloys for Biomedical Applications)

  • 정종현
    • 대한치과기공학회지
    • /
    • 제23권1호
    • /
    • pp.21-30
    • /
    • 2001
  • For biomedical applications. Ti-X%Zr-Y%Pd(X: $10{\sim}20$, Y:0.2 or 0.4) based alloys not containing harmful Al and V were newly designed, and polarization curves for their alloys were measured at $37^{\circ}C$ in 5% HCl solution in order to understand effects of Zr on the corrosion. From the results of anodic polarization behavior, it was found that the corrosion resistance increased with increasing Zr content. The results show their potential to develope Ti-based alloys for biomedical materials. The Ti-20%Zr-0.2%Pd alloy shows excellent corrosion resistance and was superior to those of the Ti. Ti-6%Al-4%V ELI alloy, Co-30%Cr-6%Mo alloy and STS 316L stainless steel.

  • PDF

금속 표면처리방법이 니켈-크롬 합금 의치상과 첨상레진간의 결합강도에 미치는 영향 (EFFECTS OF METAL SURFACE TREATMENTS ON THE SHEAR BOND STRENGTH BETWEEN NI-CR DENTURE BASE AND RELINE RESINS)

  • 김영일;정창모;전영찬
    • 대한치과보철학회지
    • /
    • 제40권4호
    • /
    • pp.396-405
    • /
    • 2002
  • The purpose of this study was to evaluate the effects of four metal surface treatments on the shear bond strength of reline resin to Ni-Cr alloy. The denture base metal used in this study was Ni-Cr alloy(Ticonium Premium 100. Ticonium Co., U.S.A.). 120 specimens were divided into five metal surface treatments: sandblasting only, MR. BOND(Tokuyama Corp.. Japan), Cesead Opaque Primer(Kuraray Co., Japan), METALPRIMER II(GC Corp., Japan) and Super-Bond C&B(Sun Medical Co., Japan) after sandblasting. They were bonded with one of three reline resins Mild Rebaron(GC Corp., Japan), Mild Rebaron LC(GC Corp., Japan) and Meta Base M(Sun Medical Co., Japan). Then they were thermocycled 1,000 times at temperature of $4^{\circ}C$ and $60^{\circ}C$. The shear bond strengths were measured using the universal testing machine(Instron, Model 4301, England) with a cross-head speed of 2 mm/min. The results were as follows : 1. All metal primers and adhesive cement significantly improved the bond strength of reline resin to Ni-Cr alloy compared with sandblasted specimens. 2. In Mild Rebaron and Mild Rebaron LC. Cesead Opaque Primer showed the highest bond strength, but the differences among Cesead Opaque Primer, MR. BOND and METALPRIMER II were not significant. The bond strength of Cesead Opaque Primer was significantly different with that of Super-Bond C&B. 3. In Meta Base M, Super-Bond C&B showed the highest bond strength, but there was no difference between Super-Bond C&B and three metal primers. 4. There was no difference in the bond strength between Mild Rebaron and Mild Rebaron LC when metal surface was treated with the same method. 5. The bond strengths of Mild Rebaron and Mild Rebaron LC treated with Cesead Opaque Primer were higher than that of Meta Base M. The bond strengths of Mild Rebaron treated with MR. BOND and METALPRIMER II was higher than that of Meta Base M, However, there was no difference among three reline resins treated with Super-Bond C&B.

Co-Cr-Ti 합금으로 제작한 conical telescope 외관의 변연적합도와 유지력에 관한 연구 (MARGINAL DISCREPANCY AND RETENTION FORCE OF CONICAL TELESCOPE OUTER CROWN WITH CO-CR-TI ALLOY)

  • 정희찬;정창모;전영찬;임장섭
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.214-225
    • /
    • 2000
  • The purpose of this study was to investigate the effects of investing conditions on the marginal discrepancy of conical telescope outer crown with Co-Cr-Ti alloy(Dentitan) and to compare the marginal discrepancy and the retention force of outer crowns using different pattern materials(plastic foil, casting wax, pattern resin). To evaluate the effects of investing conditions on the marginal discrepancy, patterns with plastic foil were invested under three different liquid/powder ratio conditions using phosphate bonded investment(Univest-nonprecious): standard, 10% decreased and 10% increased. At each liquid/powder ratio condition, metal ring was lined with single or double layers of ceramic ring liner. The marginal discrepancy of outer crown at different investing conditions was measured by ${\times}100$ compact measuring microscope(STM5, Olympus, Japan). For measurement of the marginal discrepancy and the retention force of outer crown using different pattern materials, the investing condition of 10% decreased liquid/powder ratio and double layers of ring liner was selected because this investing condition resulted in the best fit of outer crown. Marginal discrepancy was measured in the same way above and retention force on universal testing machine. Under the conditions of this study, the following conclusions were drawn: 1. The thickness of ring liner had more influence on the marginal discrepancy of outer crown than the liquid/powder ratio, and the acceptable marginal fitness could not be expected at the investing condition directed by investment manufacturer 2. There were no differences in the marginal discrepancy of outer crown among three different pattern materials(P>0.05). 3. Casting wax showed the greatest retention force(1640g) of outer crown, followed by pattern resin(1110g), plastic foil(820g). However, there was no significant difference between plastic foil and pattern resin(P>0.05). 4. Plastic foil showed the least variation in marginal discrepancy and retention force.

  • PDF

HVOF 용사 코팅 공정 조건에 따른 코팅층의 기공도 예측 (Porosity Prediction of the Coating Layer Based on Process Conditions of HVOF Thermal Spray Coating)

  • 전준협;서남혁;이종재;손승배;이석재
    • 한국분말재료학회지
    • /
    • 제28권6호
    • /
    • pp.478-482
    • /
    • 2021
  • The effect of the process conditions of high-velocity oxygen fuel (HVOF) thermal spray coating on the porosity of the coating layer is investigated. HVOF coating layers are formed by depositing amorphous FeMoCrBC powder. Oxygen pressure varies from 126 to 146 psi and kerosene pressure from 110 to 130 psi. The Microstructural analysis confirms its porosity. Data analysis is performed using experimental data. The oxygen pressure-kerosene pressure ratio is found to be a key contributor to the porosity. An empirical model is proposed using linear regression analysis. The proposed model is then validated using additional test data. We confirm that the oxygen pressure-kerosene pressure ratio exponentially increases porosity. We present a porosity prediction model relationship for the oxygen pressure-kerosene pressure ratio.

서보모터방식 마찰용접을 이용한 TiAl 합금과 SCM440의 접합에 미치는 용접조건의 영향 (Effects on the Joining Condition of TiAl Alloy and SCM440 by Servo Motor Type Friction Welding)

  • 박종문;김기영;김경균;오명훈
    • 열처리공학회지
    • /
    • 제29권2호
    • /
    • pp.66-74
    • /
    • 2016
  • In this study, characteristics of TiAl alloy and SCM440 (Cr-Mo steel) have been investigated with the various joining condition by servo motor type friction welder. The experimental factors of friction welder used in this study are spindle revolution, friction speed, and distance, upset speed and distance, respectively. Servo motor type friction welder could be controlled by the level of oil pressure, and it could be performed by position control dependence of electrical energy. Mechanical properties and morphology of welded interface were characterized by various joining condition. This aroused due to the bond strength dependence on friction heat and size of the heat affected zone. Therefore, it is necessary to have enough friction heat and decreased heat affected zone for good friction welding between dissimilar metals. An optimum bond was obtained between TiAl alloy and SCM440 by controlling friction speed and distance. At the spindle revolution 4,000 rpm, friction speed 120 mm/min, friction distance 15 mm, the bond strength was found to be 312 MPa.

A Study of mechanical properties of oxide layer removed Co-Cr-Mo abutments

  • Ryu, Jae-ho;Huh, Jung-Bo;Ro, Jung-Hoon;Yun, Mi-Jung;Jeong, Chang-Mo
    • 대한치과의사협회지
    • /
    • 제53권11호
    • /
    • pp.804-816
    • /
    • 2015
  • PURPOSE: The aim of this study was to evaluate the influence of the oxide layer removal process in the Co-Cr-Mo (CCM) abutment after casting procedure on the prosthesis settlement and screw stability. MATERIALS AND METHODS: CCM abutments of four different interface conditions (CCM-M; machined, CCM-O; oxide layer formed, CCM-B; blasted, CCM-P; polished after blasted) and gold abutment (Gold-C; Cast with type III Gold alloy) were used. The initial settling values of abutments were evaluated according to the difference of implant-abutment length when the tightening torques were applied at 5 Ncm and 30 Ncm, and the settling values of abutments caused by loading were evaluated according to the difference of implant-abutment length before and after loading with 250 N, 100000 cycle. The loss ratios of removal torque for abutment screws were evaluated according to the difference in value of removal torques under 30 Ncm tightening torque applied before and after cyclic loading. RESULTS: The CCM-P and CCM-B group showed a higher initial settling value compared with the Gold-C group (P<.05), while the Gold-C group showed the highest settling values caused by loading (P<.05) and no significant differences were observed for between CCM groups (P>.05). The loss ratio of removal torque values for the CCM-B, CCM-P groups did not differ significantly from that of the Gold-C group (P>.05). CONCLUSION: Even though the oxide layer was removed by different methods, CCM abutment with internal conical connection structure showed lower abutment settling and similar screw loosening after cyclic loading compared with gold abutment.