• Title/Summary/Keyword: Co-Contraction

Search Result 198, Processing Time 0.029 seconds

ANALYSIS OF CLINICAL EFFECT OF $CO_2$ LASER ILLUMINATION AFTER SURGICAL EXTRACTION OF IMPACTED 3RD MOLAR (하악 매복치 발치 후 $CO_2$ laser 조사의 임상적 효과 분석)

  • Kim, In-Soo;Kim, Young-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.4
    • /
    • pp.349-352
    • /
    • 2001
  • Dental laser provides many advantages to the clinicians. Those are excellent hemostatic effect, good operating sight, minimal adjacent tissue injury, reduction of postoperative swelling & pain, reduction of postoperative infection, reduction of scar tissue & contraction, etc. The purpose of this study is to observe how these advantages work after surgical extraction of impacted third molar. From march 2000 to july 2000, we have randomly divided the patients who had been surgically extracted unilateral impacted third molar into two groups. The first group comprised $CO_2$ laser illumination with 3 watts, defocusing & continuous mode, rotating motion for about 3 minutes after finishing of surgical extraction & suture. The other group patients were not irradiated. The medications in two groups were same. We measured pain, swelling and trismus three times(pre-operation, first day after operation, and 7th day after operation). The number of the patients who had measured three times all are 64, laser irradiated groups are 36 and non-irradiated groups are 28. The age ranged from 19 to 50, with a mean of 27.9 years. The operative time ranged from 3 minutes to 50 minutes, with a mean of 12.1 minutes. In the $CO_2$ laser group, the pain intensity of the 7th day after operation was still increased significantly comparing with that of the pre-operation and the distance which were measured for the swelling was different significantly. In the other group, the mouth opening limitation was still decreased significantly.

  • PDF

TREATMENT OF MUCOCELE USING THE $CO_2$ LASER : CASE REPORT ($CO_2$ Laser를 이용한 점액종의 치료)

  • Lee, In-Cheoun;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.4
    • /
    • pp.485-489
    • /
    • 2000
  • A mucocele is a thin-walled, bluish, fluctuant swelling occurring just beneath the oral mucosa and filled with mucoid material. It usually results from damage to a salivary gland following which there is extravasation of mucus into the tissues, or occasionally it forms from dilatation of the duct of a salivary gland. The accepted treatment of a mucocele is excision of the sac and the associated minor salivary gland. Use of the $CO_2$ laser in oral surgery has several advantages. It is a very precise means of cutting tissue and causes little adjacent nontarget tissue damage. There is excellent coagulation of small blood vessels and consequently operative hemorrhage is greatly decreased. There is instant sterilization of the operative site, which decreases bacteremia. The operation sites were completely healed without any infection or complication and discomfort from swelling or pain was not noted in all cases throughout the healing process. In addition, following this therapy, there is little contraction or scarring.

  • PDF

Synthesis of Cathode Materials LiNi1-yCoyO2 from Various Starting Materials and their Electrochemical Properties

  • Song, Myoung-Youp;Rim, Ho;Bang, Eui-Yong;Kang, Seong-Gu;Chang, Soon-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.6
    • /
    • pp.507-512
    • /
    • 2003
  • The LiN $i_{l-y}$ $Co_{y}$ $O_2$ samples were synthesized at 80$0^{\circ}C$ and 85$0^{\circ}C$, by the solid-state reaction method, from the various starting materials LiOH, L $i_2$C $O_3$, NiO, NiC $O_3$, $Co_3$ $O_4$, CoC $O_3$, and their electrochemical properties are investigated. The LiN $i_{l-y}$ $Co_{y}$ $O_2$ pre-pared from L $i_2$C $O_3$, NiO, and $Co_3$ $O_4$ exhibited the $\alpha$-NaFe $O_2$ structure of the rhombohedral system (space group; R3m). As the Co content increased, the lattice parameters a and c decreased. The reason is that the radius of Co ion is smaller than that of Ni ion. The increase in da shows that two-dimensional structure develops better as the Co content increases. The LiN $i_{0.7}$ $Co_{03}$. $O_2$[HOO(800,0.3)] synthesized at 80$0^{\circ}C$from LiOH, NiO, and $Co_3$ $O_4$ exhibited the largest first discharge capacity 162 mAh/g. The size of particles increases roughly as the valve of y increases. The samples with the larger particles have the larger first discharge capacities. The cycling performances of the samples with the first discharge capacity larger than 150 mAh/g were investigated. The LiN $i_{0.9}$ $Co_{0.1}$ $O_2$[COO(850,0.1)] synthesized at 85$0^{\circ}C$ from L $i_2$C $O_3$, NiO, and $Co_3$ $O_4$ showed an excellent cycling performance. The sample with the larger first discharge capacity will be under the more severe lattice destruction, due to the expansion and contraction of the lattice during intercalation and deintercalation, than the sample with the smaller first discharge capacity. As the first discharge capacity increases, the capacity fading rate thus increases.increases.s.s.s.

Effect on Improvement of Muscle Strength for Loading Pattern using Electric Exercise Instrument (전동식 운동기기의 부하방식에 따른 근력증진 효과)

  • Kang, Seung-Rok;Kim, Kyung;Jeong, Gu-Young;Seo, Young-Bum;Jeong, Jang-Sik;Kim, Jung-Ja;Kwon, Tae-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.2
    • /
    • pp.229-238
    • /
    • 2012
  • This study is to compare muscle strength between isotonic exercise and isotonic & isokinetic exercise. Participants are 12-man and 10-woman whom they are healthy without medical history in shoulder, elbow and lumbar joint. We performed experiment total 4-weeks that exercise 3-days a week each exercise pattern. We measured shoulder, elbow and lumbar joint torque with BIODEX and circumference of muscle in upper arms once a week. The result showed that isotonic & isokinetic exercise pattern significantly more improved joint torque in shoulder, elbow, lumbar than isotonic exercise pattern. Because that isotonic & isokinetic exercise pattern supplied muscle strengthen and caused muscle contraction. This exercise pattern can be used new exercise training method for major athlete and normal people. Also this pattern can be used rehabilitation treatment.

Multifidus Thickness Comparison between the Effectiveness of Abdominal Bracing and Maximum Expiration Maneuvers in Lumbo-Pelvic Upright Sitting Posture

  • Ko, Minjoo;Kim, Sujung
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.4
    • /
    • pp.2178-2183
    • /
    • 2020
  • Background: Trunk flexor-extensor muscles' co-activation and upright posture are important for spinal stability. Abdominal bracing and maximal expiration are being used as exercises to excel torso co-contraction. However, no study has on comparison of the effect of this exercise on multifidus in the upright sitting posture. Objectives: This study aims to verify the effectiveness of abdominal bracing and expiration maneuvers in lumbo-pelvic upright sitting. Design: Cross-sectional study. Methods: Eighteen healthy women were recruited for this study. The multifidus muscle thickness of all subjects was measured in three sitting conditions (lumbo-pelvic upright sitting, lumbo-pelvic upright sitting with abdominal bracing, and lumbo-pelvic upright sitting with maximum expiration) using ultrasound. One-way repeated measure analysis of variance was used for the evaluation. Results: Compared to lumbo-pelvic upright sitting, lumbo-pelvic upright sitting with abdominal bracing and lumbo-pelvic upright sitting with maximum expiration were associated with significantly increment of muscle thickness. There was no significant difference in muscle thickness between lumbo-pelvic upright sitting with abdominal bracing and lumbo-pelvic upright sitting with maximum expiration. Conclusion: Abdominal bracing and maximum expiration could be beneficial to increasing lumbar multifidus thickness in lumbo-pelvic upright sitting.

The Experimental Study of Insulation Structure for BOG Re-liquefaction Drum (증발가스 재액화 드럼의 단열구조에 관한 실험적 연구)

  • Kim, Ik-Soo;Jung, Young-Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.1
    • /
    • pp.7-13
    • /
    • 2021
  • The re-liquefaction drum is a product that installed spray nozzles at the top to directly spray overcooled LNG into evaporative gas and installed demistors to facilitate gas separation, which was developed to increase the re-liquidity efficiency of small scale re-liquefaction facilities. In the hydrostatic test of the drum, no leakage occurred even at a pressure of 1.5 times the design pressure, but during the BOR(Boil Off Rate) test, the bolt loosening occurred due to contraction and expansion by temperature change. For the continued use of the product, insulation construction on flange connections was developed to enable detachment and attachment, and the comparison of heat load with existing insulation confirmed that it was very small compared to the inlet flow rate in the drum.

Analysis of Premotor Time and Electro-Mechanical Delay of Ankle Joint Muscles: A Comparison between Sitting and Standing Postures (족관절 근육의 전운동 시간과 전기역학적 지연 분석: 앉은 자세와 선 자세의 비교)

  • Kim, Ji-Won;Jeong, Hong-Young;Kwon, Yu-Ri;Kim, Hyo-Hee;Eom, Gwang-Moon;Park, Byung-Kyu
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.98-103
    • /
    • 2012
  • The purpose of this study was to compare premotor time(PMT) and electro-mechanical delay(EMD) between sitting and standing posture. Twenty four healthy young subjects(12 women and 12 men) participated in this study. Subjects were instructed to perform maximal, voluntary, isometric contraction of ankle muscle(tibialis anterior and gastrocnemius muscles) in reaction to auditory stimulus. PMT and EMD, calculated from stimulus, EMG and torque profile were compared between sitting and standing postures. As statistical analysis, paired t-test was performed to assess difference between sitting and standing posture. In both tibialis anterior and gastrocnemius muscles, EMD was found to be significantly longer for standing than sitting. However, PMT in standing posture was longer than that in sitting posture only in gastrocnemius muscles. These result indicate that increased reaction time, particularly, increased EMD of ankle muscles in standing posture may be caused by co-contraction of ankle muscles for postural control in standing posture.

FARFARAE FLOS INHIBITS HISTAMINE-INDUCED CONTRACTILE RESPONSES OF AIRWAY SMOOTH MUSCLE (관동화전탕액(款冬花煎湯液)이 기관지평골근(氣管支平滑筋)에 미치는 영향(影響))

  • Han, Jong-Hyun;Kang, Sung-Yong;Yu, Kwang-Suk;Jin, Sang-Sik;Ha, Kyung-Hwa;Lee, Kyung-Ja
    • The Journal of Internal Korean Medicine
    • /
    • v.17 no.1
    • /
    • pp.210-217
    • /
    • 1996
  • Farfarae Flos, a traditional herb medicine, has been used in Korea and China for many centuries as a treatment for respiratory disease. The purpose of the present study was to determine the effect of Farfarae Flos on histamine-induced tracheal smooth muscle contraction in rats. Guinea pigs(500g, female) were killed by CO2 exposure and a segment (8-10mm) of the thoracic trachea from each guinea pig was cut into equal segments and mounted 'in pairs' in a tissue bath. Contractile force was measured with force displacement transducers under 0.5g loading tension. The dose of histamine which evoked 50% of maximal response (ED50) was obtained from cumulative dose response curves for histamine (10-7-10-4M). Contractions evoked by histamine(ED50) were inhibited significantly by Farfarae Flos. The mean percent inhibition was 8.7% after 1.5mg/ml Farfarae Flos, and 33.5% (p<0.05) after 5.0mg/ml Farfarae Flos. Propranolol (10-7M) slightly but significantly attenuated the inhibitory effects of Farfarae Flos. Following treatment with propranolol, the mean percent inhibition caused by 5.0mg/ml Farfarae Flos. Indomethacin and methylene blue (10-7M) did not significantly alter the inhibitory effect of Farfarae Flos. These results indicate that Farfarae Flos can relax histamine-induced contraction of guinea pig tracheal smooth muscle, and that this inhibition involves, in part, symphathetic nerve system.

  • PDF

The Effect of Trunk Muscle Activity on Bridging Exercise According to the Knee Joint Angle (슬관절 각도에 따른 교각운동이 체간근 활성도에 미치는 영향)

  • Kim, Kyung-Hwan;Park, Rae-Jun;Jang, Jun-Hyeok;Lee, Woo-Hyung;Ki, Kyong-Il
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.3
    • /
    • pp.405-412
    • /
    • 2010
  • Purpose : The purpose of this study was to assess the effects of the trunk muscle activity on bridging exercise according to the knee joint angle. Methods : Twenty-five healthy adults volunteered to participate in this study. Subjects were required to complete following four bridging exercises; knee joint flexion $120^{\circ}$, $90^{\circ}$, $60^{\circ}$, $45^{\circ}$. Surface electromyography from selected trunk muscles was normalized to maximum voluntary isometric contraction. Muscle activity was measured by QEMG-4 system(LXM 3204, Laxtha Korea). A repeated measures of one-way ANOVA with post-hoc Bonferroni's correction was used to determine the influence of bridging exercise on muscle activity for each muscle and descriptive statistics was used to determine local/global muscle ratio. Results : The internal oblique of bridging exercises $120^{\circ}$, $90^{\circ}$ showed significantly(p<.05). The erctor spinae of all bridging exercises showed significant excepted between $60^{\circ}$ and $45^{\circ}$(p<.05). Median of internal oblique/rectus abdominis ratio of $120^{\circ}$ was 4.41, $90^{\circ}$ was 3.94, $60^{\circ}$ was 3.58, $45^{\circ}$ was 3.39. Median of internal oblique/external oblique ratio of $120^{\circ}$ was 2.66, $90^{\circ}$ was 2.43, $60^{\circ}$ was 2.87, $45^{\circ}$ was 2.64. Conclusion : Angular motion decreasing with knee joint flexion made erector spinae activation increase. on the other hand, as decreasing abdomen muscle activation, the more performing motor learning is required for abdomen muscle strength and co-contraction for the trunk stabilization.

The Effects of Fructose on Contractility of Isolated Rat Atria Depressed with Lidocaine (Lidocaine에 의해 억제된 심근수축력에 대한 Fructose의 영향)

  • Ko Kye-Chang;Sohn Chi-Dong;Jung Jee-Chang
    • The Korean Journal of Pharmacology
    • /
    • v.22 no.1 s.38
    • /
    • pp.51-59
    • /
    • 1986
  • The effect of metabolic substrate fructose on the force of contraction of isolated rat atria depressed with lidocaine was determined. Fructose produced dose-dependent increase in the force of contraction of isolated atria depressed by substrate-free Krebs-Ringer bicarbonate medium. The maximally effective concentration of fructose was 30 mM. The isolated atria, suspended in Krebs-Ringer bicarbonate glucose medium aerated with 95% $O_2-5%CO_2$at $30^{\circ}C$ and pH 7.4, were depressed 50% by approximately 2.34 mg/100 ml of lidocaine. Addition of 30 mM fructose to these depressed atria resulted in a marked increase in the contractile force similar to that with pyruvate and acetate. Fructose had no significant effect, however, on atria exposed to low-calcium medium. The results are consistent with a previous report suggesting blockade by lidocaine of the uptake or utilization of glucose in the glycolytic pathway, and further pinpoint the blockade as an early step in the glycolytic sequence prior to the phospho-fructokinase step.

  • PDF