• Title/Summary/Keyword: Co-60 ${\gamma}-radiation$

Search Result 343, Processing Time 0.031 seconds

Impact of Gamma Irradiation Effects on IGBT and Design Parameter Considerations

  • Lho, Young-Hwan
    • ETRI Journal
    • /
    • v.31 no.5
    • /
    • pp.604-606
    • /
    • 2009
  • The primary dose effects on an insulated gate bipolar transistor (IGBT) irradiated with a $^{60}Co$ gamma-ray source are found in both of the components of the threshold shifting due to oxide charge trapping in the MOS and the reduction of current gain in the bipolar transistor. In this letter, the IGBT macro-model incorporating irradiation is implemented, and the electrical characteristics are analyzed by SPICE simulation and experiments. In addition, the collector current characteristics as a function of gate emitter voltage, VGE, are compared with the model considering the radiation damage of different doses under positive biases.

${\gamma}-ray$ Effects on Steroid Hormone Concentration of Mouse Ovarian Follicles (생쥐의 난소내 스테로이드호르몬 농도에 미치는 ${\gamma}$-선의 영향)

  • Lee, Young-Keun;Kim, Jin-Kyu;Yoon, Yong-Dal
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.3
    • /
    • pp.179-188
    • /
    • 1994
  • Mice were whole body irradiated with dose of 2.88Gy and 7.2Gy(Co-60) in order to observe the morphological and functional changes in radio sensitive mouse ovary. Microtechnical sectionates of $7{\mu}m$ thickness from ovary were made for light microscopy and concentrations of progesterone, testosterone and estradiol in ovarian homogenates were analyzed by radioimmunoassay. Gamma radiation resulted in the increase of atretic ratio of preantral and antral follicles, the increase of progesterone concentration in ovarian homogenates, and the low level of testosterone and estradiol. It is suggested that radiation protect the activity of $3{\beta}-HSD$(hydroxysteroid dehydrogenase) and isomerase in the follicular theca cell followed by low level of testosterone and estradiol and thereafter follicular atresia proceed.

  • PDF

In-service Investigation on the Flow Dynamics of a Trayed Column from the Measurement of an Internal Density by using a Gamma Absorption Technique (Gamma Absorption Technique를 이용한 Trayed Column의 가동 중 내부 밀도분포 측정에 의한 유체 유동상태 진단)

  • Kim, Jae-Ho;Kim, Jong-Bum;Kim, Jin-Seop;Lee, Na-Young;Lee, Sung-Sik;Jang, Seok-Joon;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.35-40
    • /
    • 2008
  • A distillation tower is one of the important facilities which separates and refines a crude oil stream according to certain boiling points. Its operation efficiency can affect the productivity of a refinery substantially. The objective of this study is to elucidate some operational information on the internal conditions of a distillation tower from a measurement of density profile by using a sealed gamma-ray source and a radiation detector. Gamma radiation counts were measured by a BGO detector positioned diametrically outside the tower-wall, opposite to the gamma source(Co-60) as the detector and the source were lowered concurrently. From the results, structural abnormality of the trays was not found inside the tower. Considering the flow distribution patterns, however, a vapor phase was dominantly formed at the upper part of the tower and a liquid phase at the lower part. From the gamma scanning of the distillation tower, it is anticipated that the gamma absorption technique can be used as an important tool for confirming the structural soundness of trays and investigating flow distribution in refinery facilities.

Feasibility Study of Vertical Multileaf Collimator for Determination of Irradiation Size (수직형 다엽 콜리메이터의 방사선 조사면 크기 결정을 통한 유용성 연구)

  • Lee, Chang-Yeol;Son, Ki-Hong;Shin, Sang-Hun;Park, Seung-Woo;Lee, Dong-Han;Jung, Hai-Jo;Choi, Mun-Sik;Oh, Won-Young;Kim, Kum-Bae;Yang, Gwang-Mo;Ji, Young-Hoon
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.3-11
    • /
    • 2011
  • The purpose of this study was to evaluate feasibility of Vertical Multileaf Collimator for determination of irradiation size using Vertical Multileaf Collimator and lead block to determine 4 different irradiation shape in case of Co-60 gamma-ray and 6 MV X-ray. We chose ion chamber, glass dosimeter and EBT chromic film to compare with Vertical Multileaf Collimator results and lead block results. In case of Co-60 gamma-ray and 6 MV X-ray, the central axis point dose normalized at reference field of lead block with ion chamber results for Vertical Multileaf Collimator were estimated higher than lead block about 5.1%, 4.2%. In case of Co-60 gamma-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 2.2%, 7.8%, 7.2%, 4.0% for reference, circle, triangle, cross field, respectively. In case of 6 MV X-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 6.7%, 6.2%, 3.8%, 6.2% for reference, circle, triangle, cross field, respectively. The results of EBT chromic film, Vertical Multileaf Collimator of penumbra size for all irradiation shape was smaller than lead block of those size that 2.0~3.5 mm for Co-60 gamma-ray, 0.5~1.0 mm for 6 MV X-ray. The results from this study, radiation treatment volume that results in shielding block can be minimized. In addition, during radiation treatment for 2, 3-dimensional radiation therapy using a Vertical Multileaf Collimator of this survey can be used to determine variety of irradiation fields.

Verification of Secondary Electron Generated by Head Screw in Gamma Knife Using Monte Carlo N-Particle Simulation

  • Kim, Heesoo;Lee, Jeong-Woo
    • Progress in Medical Physics
    • /
    • v.31 no.2
    • /
    • pp.29-34
    • /
    • 2020
  • Purpose: The interaction of various substances inserted into the human body and radiation can confirm the radiation enhancement effect. A Leksell frame inserted into the human body for gamma knife treatment will cause not only pain and inconvenience to the patient, but also additional exposure to the patient's normal tissues. In this study, we attempt to confirm the additional exposure caused by the interaction of the Leksell frame and thermoplastic mask, and 60Co used for gamma knife treatment. Methods: A 60Co energy of 1.17, 1.33 MeV is applied using Monte Carlo simulation, and fixation screws and thermoplastic mask are fabricated using aluminum and titanium alloy, and Carbon compounds. Results: Results show a dose enhancement of up to 396.27% higher compared with that without a Leksell frame and up to 391.25% in thermoplastic mask. Conclusions: Hence, appropriate treatment methods and materials must be used to reduce additional exposure to normal tissues.

Luminescence Analysis of Cookie Mixed with Gamma-irradiated Mineral Depending on Its Processing Methods and Sonication Time (감마선 조사된 무기질 함유 쿠키의 제조 방법 및 초음파 처리 시간에 따른 Luminescence 분석 특성)

  • Kim, Byeong-Keun;Kim, Cheong-Tae;Lee, Jin-Won;Lee, Kwang-Hyun;Kim, Jae-Kyung;Song, Beom-Seok;Kim, Jae-Hun;Le, Ju-Woon;Kwon, Joong-Ho
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • Photostimulated luminescence (PSL) and thermoluminescence (TL) analyses were applied to identify the cookie molds mixed with 2 mg of 10 kGy-irradiated minerals according to cookie processing methods and sonication time (0~60 min) for mineral separation. PSL analysis showed that photon counts of cookies, dried or baked, ranged intermediate levels between the lower and upper threshold (700~5,000 counts/60 s), thereby showing its unsuitablility for screening of irradiated cookie. The TL glow curve intensities, measured according to mineral separation time (5, 10, 20, 40 and 60 mins) from the cookies using a sonicator, were high enough to identify irradiation status and significantly increased with the time in dried cookies. Those of baked cookies, however, were relatively low and not linearly increased with the time, but still possible to identify them (p<0.05).

Effects of Gamma Radiation on Fiber Bragg Gratings by the Fiber Re-coating Methods (광섬유 브래그 격자의 재코팅 방법에 따른 감마 방사선의 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.782-784
    • /
    • 2016
  • In this study, we studied the gamma-radiation effect of fiber Bragg gratings on the fiber re-coating methods. The fiber Bragg gratings were exposed to gamma-radiation up to a dose of 100 kGy at the dose rate of 104 Gy/min. In our experimental results, we confirmed that the fiber acrylate re-coating process leads to a slightly lower radiation sensitivity of FBGs.

  • PDF

Effects of Gamma Irradiation on Array Type Fiber Bragg Grating Sensors (배열형 FBG 센서의 감마선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.937-939
    • /
    • 2016
  • In this study, we studied the gamma-radiation effect of fiber Bragg gratings (FBGs) manufactured by array sensors. The array FBGs were fabricated in a different Bragg wavelength using the same commercial Ge-doped fiber and exposed to gamma-radiation up to a dose of about 100 kGy at the dose rate of 113 Gy/min. It was analyzed radiation effects by measuring the radiation-induced change in the temperature sensitivity coefficient and Bragg wavelength shift after irradiation.

  • PDF

Study On Irradiation Effect By Co$^{60}$To The Condensers Which Are Used In Electronic Circuit (O.F paper condenser를 비롯한 전자회로용 condenser들에 대한 Co$^{60}$의 조사효과에 관한 연구)

  • 지철근;조성욱
    • 전기의세계
    • /
    • v.23 no.3
    • /
    • pp.67-69
    • /
    • 1974
  • The electric characteristics of all the instruments and materials used in atomic field is changed due to radiation damages by the effects of radio activities. In this study, when the condenser is radiated by Gamma-ray, variations in its electric properties have been investigated. The following results are obtained. (1) The capacitance in O.F paper condenser is exponentially increased as the quantity of irradiation by Gamma-ray is increased, but polyethylene, ceramic, chemical, neostyrene, mylar condenser are decreased. and in case of more than 10$^{7}$ of irradiation it has saturated state, (2) The breakdown voltage and the .delta. in condensers except the O.F paper condenser are exponentially increased as the quantity of irradiation by Gamma-ray is increased but in case of more than 10$^{7}$ .gamma. of irradiation it has decreased.

  • PDF

Gamma-ray Dosimetry with Thin Plastic Film

  • Yoo, Young-Soo;Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.223-233
    • /
    • 1973
  • Thirty two different kinds of domestic plastic films for use in measuring high gamma-ray dose have been collected and their dosimetric characteristics investigated with the help of a Co-60 gamma radiation source. Among them a rigid polyvinyl chloride(PVC) film of 0.06mm in thickness which is manufactured by Lucky Chemical Co., Korea, seem to be the most suitable one for this purpose. The relation between optical density at 3100$\AA$ and radiation exposure in this PVC film was linear in the range of 0.6$\times$10$^{6}$ R to 1.3$\times$10$^{7}$ R, and also the film showed a good reproducibility within 9% under the standard experimental condition. The effect of absorbed dose, oxygen content of surrounding atmosphere and irradiation temperature have also been studied for this film. It appeared to have a good property in the dosimetrical point of view.

  • PDF