• Title/Summary/Keyword: Co-60 ${\gamma}-radiation$

Search Result 344, Processing Time 0.024 seconds

Development of Radiation Dosimeter using Commercial p-MOSFET (상용 p-MOSFET을 이용한 방사선 선량계 개발)

  • Lee, Nam-Ho;Choi, Young-Su;Lee, Yong-B.;Youk, Geun-Uck
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • When a metal oxide field effect transistor (MOSFET) is exposed to ionizing radiation, electron/hole pairs are generated in its oxide layer. The slow moving holes of them are trapped in the oxide layer of p-MOSFET and appear as extra charges that change the characteristics of the transistor. The radiation-induced charges directly impact the threshold (turn-on) voltage of the transistor. This paper describes the use of the radiation-induced threshold voltage change as an accumulated radiation dose monitoring sensor. Two kinds of commercial p-type MOSFETS were tested in a Co-60 gamma irradiation facility to see their capabilities as a radiation dosimeter. We found that the transistors showed good linearity in their threshold voltage shift characteristics with radiation dose. The results demonstrate the potential use of commercial p-MOSFETS as inexpensive radiation sensors for the first time.

  • PDF

Amentoflavone Acts as a Radioprotector for Irradiated v79 Cells by Regulating Reactive Oxygen Species (ROS), Cell Cycle and Mitochondrial Mass

  • Xu, Ping;Jiang, En-Jin;Wen, Si-Yuan;Lu, Dan-Dan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.18
    • /
    • pp.7521-7526
    • /
    • 2014
  • Radioprotective effects of amentoflavone were investigated by examining cell viability, apoptosis, cell cycling concentrations of intracellular ROS (reactive oxygen species), and relative mitochondrial mass by flow cytometry after $^{60}Co$ irradiation. Pretreatment with amentoflavone 24 hours prior to 8 Gy $^{60}Co$ ${\gamma}$-ray irradiation significantly inhibited apoptosis, promoted the G2 phase, decreased the concentration of ROS and mitochondrial mass. These results collectively indicate that amentoflavone is an effective radioprotective agent.

Optimized inverse distance weighted interpolation algorithm for γ radiation field reconstruction

  • Biao Zhang;Jinjia Cao;Shuang Lin;Xiaomeng Li;Yulong Zhang;Xiaochang Zheng;Wei Chen;Yingming Song
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.160-166
    • /
    • 2024
  • The inversion of radiation field distribution is of great significance in the decommissioning sites of nuclear facilities. However, the radiation fields often contain multiple mixtures of radionuclides, making the inversion extremely difficult and posing a huge challenge. Many radiation field reconstruction methods, such as Kriging algorithm and neural network, can not solve this problem perfectly. To address this issue, this paper proposes an optimized inverse distance weighted (IDW) interpolation algorithm for reconstructing the gamma radiation field. The algorithm corrects the difference between the experimental and simulated scenarios, and the data is preprocessed with normalization to improve accuracy. The experiment involves setting up gamma radiation fields of three Co-60 radioactive sources and verifying them by using the optimized IDW algorithm. The results show that the mean absolute percentage error (MAPE) of the reconstruction result obtained by using the optimized IDW algorithm is 16.0%, which is significantly better than the results obtained by using the Kriging method. Importantly, the optimized IDW algorithm is suitable for radiation scenarios with multiple radioactive sources, providing an effective method for obtaining radiation field distribution in nuclear facility decommissioning engineering.

Radiation Sensitivity of Basidiospore and Mycelium in Pleurotus ostreatus

  • Lee, Young-Keun;Chang, Hwa-Hyoung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.287-293
    • /
    • 1999
  • To assess the effects of gamma-ray (Co-60) on radiation sensitivity and genetic similarity of the basidiospore and mycelium in oyster mushroom, Pleurotus ostreatus, the D$_{10}$ values and RAPD patterns were analysed. Three strains were isolated from basidiospores (PO-Bl, -B2, and - B3 from 2 kGy irradiation group) and five strains from mycelia (PO-Ml, -M2 from 1 key, PO-M3 from 2 kGy, and PO-M4 and -M5 from 2+1 key irradiation group). The D$_{10}$ values of basidiospore and mycelium of P. Preurotus ostreatus were 1,250 Gy and 500 Gy, respectively. The growth rates of the eight strains on the five media were various and the activities of extracellular chitinases of them were generally higher than those of the control. By the gamma-ray radiation, 22-25% of genetic similarities were changed in the basidiospore strains and 23-36% of them in the mycelium strains. From these results, it seems that the basidiospore could be more radio-resistant than the mycelium of P. ostreatus and that the genetic similarity of the mycelium of P ostrentus could be changed easier than that of the basidiospore by the gamma-ray radiation.ion.

  • PDF

Some Characteristics of Teflon-Thermoluminescent Dosimeters (테프론 열형광선량계(熱螢光線量計)의 특성(特性))

  • Lee, Soo-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.7 no.1
    • /
    • pp.23-33
    • /
    • 1982
  • The characteristic thermoluminescence responses of Teflon thermoluminescent dosimeters to radiations have been studied by the variation of radiation qualities as well as the high dose radiations. The change in the sensitivity of TLDs for different radiation qualities were studied through not only the photon energy dependence but also the change of supralinearity on the photon energy dependence, by exposing $^{60}Co$ gamma rays, the effective X-rays of 44keV, 69keV, 108keV, and thermal neutron of 0.04 eV. The results were as the following: The TL response of $T-CaSO_4$: Dy as a function of absorbed dose was linear up to about 5 Gy, and the response beyond 5Gy was supralinear for $^{60}Co$ gamma rays. The supralinearity of T-LiF-7 became noticeably apparent more than that of $T-CaSO_4$:Dy and also the lower the LET of radiation became the higher the supralinear effects were. No supralinearity appeared for the thermal neutron irradiations equivalent to 10Gy of $^{60}Co$ gamma rays. The relative sensitivities (Rs), which depended on the doses of $^{60}Co$ gamma rays to the TLDs of T-LiF-7 and T-$CaSO_4$:Dy could be, respectively, approximated to the following empirical formula fitted by the least square method: $$R_{LiF}=1.021-0.04581\;logD+0.402(logD)^2-0.405(logD)^3,\;\;5{\times}10^3{\geq}D{\geq}1(Gy)$$ $$R_{CaSO_4}=0.976-0.3241\;logD+0.262(logD)^2-0.298(logD)^3,\;5{\times}10^3{\geq}D{\geq}1(Gy)$$.

  • PDF

The Study on Design of lead monoxide based radiation detector for Checking the Position of a Radioactive Source in an NDT (비파괴검사 분야에서 방사선원의 위치 확인을 위한 산화납 기반 방사선 검출기 설계에 관한 연구)

  • Ahn, Ki-Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.183-188
    • /
    • 2017
  • In recent years, the automatic remote control controller of the gamma ray irradiator malfunctions, and radiation workers are continuously exposed to radiation exposure accidents. In the non-destructive testing field, much time and resources are invested in establishing a radioactive source monitoring system in order to prevent potential incidents of radiation. In this study, the gamma-ray response properties of the lead monoxide-based radiation detector were estimated through monte carlo simulation as a previous study for the development of a radioactive source location monitoring system that can be applied universally to various non-destructive testing equipment. As a result of the study, the optimized thickness of the radiation detector varies according to the gamma-ray energy emitted from the radioactive source, and the optimized thickness gradually increases with increasing energy. In conclusion, the optimized thickness of the lead monoxide-based radiation detector was $200{\mu}m$ for the Ir-192, $150{\mu}m$ for the Se-75 and $300{\mu}m$ for the Co-60. Based on these results, the appropriate thickness of lead monoxide-based radiation detector considering secondary-electron equilibrium was evaluated to be $300{\mu}m$ for general application. These results can be used as a basic data for determining the appropriate thickness required in the radiation detector when developing a radiation source location monitoring system for universal application to various non-destructive testing equipment in the future.

Effects of Low Dose Gamma Radiation and Seed Moisture Content on Germination and Early Growth of Vegetable Crops (저선량 방사선 조사 시 종자수분함량이 채소류의 발아와 초기생장에 미치는 영향)

  • Baek, Myung-Hwa;Lee, Young-Keun;Lee, Young-Bok;Yang, Seung-Gyun;Kim, Jae-Sung
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.3
    • /
    • pp.215-219
    • /
    • 2003
  • To investigate the effects of low dose gamma radiation and seed moisture content (SMC) on germination and early growth of vegetable crops, seeds of chinese cabbage (Brassica campestris L.), radish (Raphanus sativus L.), red pepper (Capcicum annuum L.), figleaf gourd (Cucurbita ficifolia Bouche) and bottle gourd (Lagenaria siceraria Standl), with different SMC were irradiated with different doses ($0{\sim}20\;Gy$) of gamma-ray by irradiator ($^{60}Co$, ca.150 TBq of capacity, AECL). Vegetable crops in which low dose gamma radiation was irradiated in seeds with different moisture content showed different response in seed germination and early growth to low dose gamma radiation. The germination rate of chinese cabbage, figleaf ground and bottle gourd irradiated with $2{\sim}8\;Gy$ showed interactive responses against relative SMC. Also, significant interactions occurred for the early growth between those factors. The stimulating effects of gamma radiation were more pronounced for hydrated seeds of chinese cabbage, radish, figleaf gourd and bottle gourd showing prominent responses with $2{\sim}10\;Gy$ irradiation, particularly for chinese cabbage and bottle gourd. These results suggest that radiation may promote germination and early growth of vegetable crops through interaction with SMC.

Studies on the Preservation of Korean Rice by Gamma-radiation (IV) -On the free amino acids contents in gamma-irradiated rice- (감마선 조사에 의한 쌀저장에 관한 연구 (제 4 보) - 감마선 조사쌀의 유리 아미노산 함량에 관하여 -)

  • Kim Hyong-Soo;Kim Sung-Kih;Harn In-Ja
    • Korean Journal of Food Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.15-18
    • /
    • 1971
  • The Korean rice of Paldal variety was milled, in March, 1969, into brown rice and 92% polished one and each 1.5kg sample was packed in the kraft paper bags. With Co-60 gamma-irradiation, the samples were treated in the various ranges of 500, 800 and 1,000 Krad, and then they were stored at the room temperature. The changes of the contents of free amino acids in the samples were determined by the amino acid autoanalyzer (Yanagimoto, Japan, LC-type). The results obtained in June and October of the year were as follows. 1) In the disinfecting irradiation of rice by the higher doses of 500, 800 and 1,000 Krad, there wasn't any particular distinction between the control lot and irradiated lot in respect to the free amino acid contents. 2) The contents of free amino acids in rice during storage had the decreasing tendencies, and especially prominent in case of glutamic acid.

  • PDF

Synthesis of Sulfonated POF-g-Styrene ion Exchange Fibers by Radiation-Induced Polymerization and Properties of Ammonia Adsorption (방사선 중합에 의한 설폰화 POF-g-Styrene 이온교환 섬유의 합성 및 암모니아 흡착)

  • Cho, In-Hee;Baek, Ki-Wan;Lee, Chang-Soo;Nho, Young-Chang;Yoon, Soo-Kyung;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • In this study, the sulfonated ion exchange fiber was synthesized by $Co^{60}\;{\gamma}-ray$ radiation-induced graft copolymerization. Degree of grafting (DG) increased with increasing the total dose and showed the highest value at 50 v/v% styrene monomer. And also, the degree of sulfonation (DS) increased with increasing the DG and reaction temperature. DS showed the maximum value at 20 min. Ion exchange capacity and swelling ratio of ion exchange fibers increased with increasing the DS and their maximum values were 4.76 meq/g and 23.5%, respectively. Ammonia adsorption increased as increasing the ammonia concentration and ion exchange capacity and remained constant over 10 cycles.

Effect of Gamma Irradiation on the Softening of Dried Fernbrake at Different Moist-Heating Conditions (습열 조리 조건에 따른 방사선 조사 건고사리의 연화도)

  • Seung, Tae-Hwa;Lee, Ju-Woon;Byun, Myung-Woo;Kim, Mee-Ree
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.1
    • /
    • pp.104-108
    • /
    • 2006
  • Effect of gamma irradiation on the softening of dried fernbrake at different moist-heating conditions was investigated. Dried fernbrake packaged in controlled atmosphere $(CO_2\;25\%,\;N_2\;75\%)$ was irradiated up to 7 kGy with $\gamma-ray$. Hardness of dried fernbrake was significantly decreased at the irradiation dose of above 5 kGy. Hardness of cooked fernbrake was significantly decreased with increasing irradiation dose level as well as heating temperature and time. $DT_{50}$ value (The heating time required to reach the $50\%$ reduction of hardness) for irradiated fernbrake was shortened according to dose level as well as heating temperature and heating time: $DT_{50}$ value of control: 23 min, 5 or 7 kGy: $2.2\~5.0$ min at $60^{\circ}C$. Also, the activation energy for softening of irradiated fernbrake ($1.85\~1.88$ kcal/mole for $5\~7kGy$) decreased compared to control (4.30 kcal/mole). Moisture content, swelling and rehydration rate of gamma irradiated fernbrake during moist heating increased according to the irradiation doses. Sensory results showed that scores of off-flavor and odor in irradiated fernbrake upto 7 kGy were not significantly different from control. Based on these results, gamma irradiation was effective for the reduction of cooking time and the activation energy for softening of dried fernbrake with increasing dose levels.