• Title/Summary/Keyword: Closure device

Search Result 79, Processing Time 0.021 seconds

Percutaneous Transcatheter Closure of Congenital Ventricular Septal Defects

  • Jinyoung Song
    • Korean Circulation Journal
    • /
    • v.53 no.3
    • /
    • pp.134-150
    • /
    • 2023
  • Ventricular septal defects (VSDs) are the most common kind of congenital heart disease and, if indicated, surgical closure has been accepted as a gold-standard treatment. However, as less-invasive methods are preferred, percutaneous device closure has been developed. After the first VSD closure was performed percutaneously by Lock in 1988, both techniques and devices have developed consistently. A perventricular approach for closure of muscular VSD in small patients and the closure of perimembranous VSD using off-label devices are key remarkable developments. Even though the Amplatzer membranous VSD occluder (Abbott) could not be approved for use due to the high complete atrioventricular conduction block rate, other new devices have shown good results for closure of perimembranous VSDs. However, the transcatheter technique is slightly complicated to perform, and concerns about conduction problems after VSD closure with devices remain. There have been a few reports demonstrating successful closure of subarterial-type VSDs with Amplatzer devices, but long-term issues involving aortic valve damage have not been explored yet. In conclusion, transcatheter VSD closure should be accepted as being as effective and safe as surgery but should only be performed by experienced persons and in specialized institutes because the procedure is complex and requires different techniques. To avoid serious complications, identifying appropriate patient candidates for device closure before the procedure is very important.

Surgical Extraction of an Embolized Atrial Septal Defect Occluder Device into Pulmonary Artery after Percutaneous Closure

  • Yolcu, Mustafa;Kaygin, Mehmet Ali;Ipek, Emrah;Ulusoy, Fatih Rifat;Erkut, Bilgehan
    • Journal of Chest Surgery
    • /
    • v.46 no.2
    • /
    • pp.135-137
    • /
    • 2013
  • An atrial septal defect is the most common type of congenital heart disease among adults. Surgical repair or percutaneous closure of the defect is the treatment options. Even though percutaneous closure seems to be less risky than surgical repair, it may result in fatal complications like device embolism, cardiac perforation and tamponade. Herein we report a case of the embolism of a device into the pulmonary artery after one hour of percutaneous closure in which the embolized device was surgically removed and the defect was closed with a pericardial patch.

Emergent Surgical Intervention for Embolization of Atrial Septal Defect Closure Device

  • Kim, Young Hak;Kim, Hyuck;Kim, Sung Jin;Kang, Jeong Ho;Chung, Won-Sang;Shin, Jin-Ho;Lim, Young-Hyo
    • Journal of Chest Surgery
    • /
    • v.45 no.5
    • /
    • pp.320-322
    • /
    • 2012
  • The percutaneous transcatheter closure of secundum atrial septal defect has recently become an increasingly widespread alternative to surgical closure in many centers. Although immediate, short, and intermediate term results of percutaneous transcatheter septal closure are promising, the procedure is not free from inherent complications that could be lethal. We report a case of device embolization necessitating emergent surgical retrieval.

Clinical outcome of transcatheter closure of patent ductus arteriosus in small children weighing 10 kg or less

  • Park, Young-A;Kim, Nam-Kyun;Park, Su-Jin;Yun, Bong-Sic;Choi, Jae-Young;Sul, Jun-Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.12
    • /
    • pp.1012-1017
    • /
    • 2010
  • Purpose: Transcatheter closure has become an effective therapy in most patients with patent ductus arteriosus (PDA). However, there are difficulties in transcatheter closure of PDA in small children. We reviewed clinical outcomes of transcatheter closure of PDA in children weighing less than 10 kg in a single center. Methods: Between January 2003 and December 2009, 314 patients with PDA underwent transcatheter closure in our institute. Among them, 115 weighed less than 10 kg. All of these patients underwent transcatheter closure of PDA using either COOK Detachable $Coil^{(R)}$, PFM Nit-$Occlud^{(R)}$, or Amplatzer duct $occluder^{(R)}$. A retrospective review of the treatment results and complications was performed. Results: The mean age of patients was $9.1{\pm}5.9$ months (median, 8 months), and mean weight was $7.6{\pm}1.8kg$ (median, 7.8 kg). The mean diameter of PDA was $3.2{\pm}1.4mm$ (median, 3 mm). Complete occlusion occurred in 113 patients (98%). One patient was sent to surgery because of a failed attempt at device closure, and another patient had a small residual shunt after device placement. The average mean length of hospital stay was $3.0{\pm}3.3$ days, and mean follow-up duration was $21.0{\pm}19.6$ months. There were no major complications in any of the patients. Conclusion: Transcatheter closure of PDA is considered safe and efficacious in infants weighing less than 10 kg. With sufficient experience and further effort, transcatheter closure of PDA can be accepted as the gold standard of treatment for this group of patients.

Outcomes of transcatheter closure of ductus arteriosus in infants less than 6 months of age: a single-center experience

  • Choi, Gwang-Jun;Song, Jinyoung;Kim, Yi-Seul;Lee, Heirim;Huh, June;Kang, I-Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.12
    • /
    • pp.397-402
    • /
    • 2018
  • Purpose: Transcatheter device closure of patent ductus arteriosus (PDA) is challenging in early infancy. We evaluated PDA closure in infants less than 6 months old. Methods: We performed a retrospective review of infants less than 6 months of age who underwent attempted transcatheter device closure in our institution since 2004. To compare clinical outcomes between age groups, infants aged 6-12 months in the same study period were reviewed. Results: A total of 22 patients underwent transcatheter PDA closure during the study period. Patient mean age was $3.3{\pm}1.5months$, and weight was $5.7{\pm}1.3kg$. The duct diameter at the narrowest point was $3.0{\pm}0.8mm$ as measured by angiography. The most common duct type was C in the Krichenko classification. Procedural success was achieved in 19 patients (86.3%). Major complications occurred in 5 patients (22.7%), including device embolization (n=1), acquired aortic coarctation (n=2), access-related vascular injury requiring surgery (n=1), and acute deterioration requiring intubation during the procedure (n=1). Two patients had minor complications (9.1%). Twenty-four infants aged 6-12 months received transcatheter device closure. The procedural success rate was 100%, and there were no major complications. The major complication rate was significantly higher in the group less than 6 months of age (P=0.045). There was a trend toward increased major complication and procedural failure rates in the younger age group (P<0.01). Conclusion: A relatively higher incidence of major complications was observed in infants less than 6 months of age. The decision regarding treatment modality should be individualized.

Utility of 3D Echocardiography for Device Sizing During Transcatheter ASD Closure: A Comparative Study

  • Avinash Mani;Sivadasanpillai Harikrishnan;Bijulal Sasidharan;Sanjay Ganapathi;Ajit Kumar Valaparambil
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.4
    • /
    • pp.180-187
    • /
    • 2023
  • BACKGROUND: Two-dimensional (2D) transesophageal echocardiography (TEE) is commonly used for assessing patients undergoing transcatheter atrial septal defect (ASD) device closure. 3D TEE, albeit providing high resolution en-face images of ASD, is used in only a fraction of cases. We aimed to perform a comparative analysis between 3D and 2D TEE assessment for ASD device planning. METHODS: This was a prospective, observational study conducted over a period of one year. Patients deemed suitable for device closure underwent 2D and 3D TEE at baseline. Defect characteristics, assessed separately in both modalities, were compared. Using regression analysis, we aimed to derive an equation for predicting device size using 3D TEE parameters. RESULTS: Thirty patients were included in the study, majority being females (83%). The mean age of the study population was 40.5 ± 12.05 years. Chest pain, dyspnea and palpitations were the common presenting complaints. All patients had suitable rims on 2D TEE. A good agreement was noted between 2D and 3D TEE for measured ASD diameters. 3D TEE showed that majority of defects were circular in shape (60%). The final device size used had high degree of correlation with 3D defect area and circumference. An equation was devised to predict device size using 3D defect area and circumference. The mean device size obtained from the equation was similar to the actual device size used in the study population (p = 0.31). CONCLUSIONS: Device sizing based on 3D TEE parameters alone is equally effective for transcatheter ASD closure as compared to 2D TEE.

Delayed Left Atrial Perforation Associated with Erosion After Device Closure of an Atrial Septal Defect

  • Kim, Ji Seong;Yeom, Sang Yoon;Kim, Sue Hyun;Choi, Jae Woong;Kim, Kyung Hwan
    • Journal of Chest Surgery
    • /
    • v.50 no.2
    • /
    • pp.110-113
    • /
    • 2017
  • A 43-year-old man who had had a history of atrial septal defect (ASD) device closure 31 months previously presented with abrupt chest and back pain along with progressive cardiogenic shock and cardiac arrest. After resuscitation, he was diagnosed with cardiac tamponade. Diagnostic and therapeutic surgical exploration revealed left atrium (LA) perforation due to LA roof erosion from a deficient aortic rim. Device removal, primary repair of the LA perforation site, and ASD patch closure were performed successfully. The postoperative course was uneventful. The patient was discharged after 6 weeks of empirical antibiotic therapy without any other significant complications.

Acute Postpneumonectomy Empyema with Bronchopleural Fistula Treated with Vacuum-assisted Closure Device

  • Han, Woo-Sik;Kim, Kwhan-Mien
    • Journal of Chest Surgery
    • /
    • v.45 no.4
    • /
    • pp.260-262
    • /
    • 2012
  • Postpneumonectomy empyema is a life-threatening complication, which is often related with a bronchopleural fistula. After surgical repair of fistula, sterilization of infected pleural cavity is important and usually carried out by long-term cyclic irrigation. We report a case in which vacuum-assisted closure device was successfully applied to sterilize the pleural cavity and obliterate bronchopleural fistula.

Totally Thoracoscopic Ablation for Treatment of Atrial Fibrillation after Atrial Septal Defect Device Closure

  • Kim, Young Su;Jeong, Dong Seop;Kang, I-Seok;On, Young Keun
    • Journal of Chest Surgery
    • /
    • v.47 no.3
    • /
    • pp.280-282
    • /
    • 2014
  • Atrial septal defect (ASD) is one of the most common congenital heart defects in adults. Surgical repair is the most common treatment approach, but device closure has recently become widely performed in accordance with the trend toward less invasive surgical approaches. Although surgery is recommended when ASD is accompanied by atrial fibrillation, this study reports a case in which a complete cure was achieved by closure of a device and totally thoracoscopic ablation.

Guidance system about closure using push notification of smart device (스마트 기기의 푸시 알림을 이용한 휴무 안내 시스템)

  • Chung, Myoungbeom
    • Journal of Internet Computing and Services
    • /
    • v.23 no.2
    • /
    • pp.19-28
    • /
    • 2022
  • In this paper, we propose an guidance system about closure using push notification of smart device. Restaurant operators can use the proposed application to schedule and modify the restaurant closures for a week from push notification and users can check the restaurant information and whether it is closed or not through the proposed application. The proposed method uses a server system to provide closed information, and the proposed application performs push notifications to the restaurant operator every morning to confirm the day's closed again. To verify the utility of the proposed system, we built a closure management application, user application, and server system to conduct experiments for restaurant closures guidance, resulting in 96% about checking opening hours. And we confirmed that the proposed method is better than the existing information service in comparison experiments. Thus, the proposed method will be a useful service system that could easily share closure information with restaurant operators and users.