• Title/Summary/Keyword: Closing

Search Result 1,489, Processing Time 0.029 seconds

The Effect of Compliance Structures Near the Mechanical Heart Valve on Valve Surface Erosion (기계식 인공 판막 주위의 유연성 구조가 표면 괴식에 미치는 영향)

  • Lee, Hwan-Sung;Hwang, Sung-Won;Sun, Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.309-315
    • /
    • 2002
  • Since the discovery, in the 1980s, of erosion-pit-induced fractures in implanted mechanical heart valves. cavitation on the surface of mechanical heart valves has been widely studied as a possible cause of pitting. Several factors, including peak dp/dt of the ventricular pressure. maximum closing velocity of the leaflet, and squeeze flow. have been studied as indices of the cavitation threshold. In the present study. cavitation erosion on the surface of a mechanical valve was examined by focusing on squeeze flow and the water hammer phenomenon during the closing period of the valve. In this study, we measures pressure wave forms near a valve and closing velocities of a disk, which were placed in a holder with and without compliance. In case of all holders, pressure drop of below vapor pressure expect at near the surface disk. It was also found that the closing velocity of the disk increased and that cavitation erosion was enhanced too. These results suggest that disk closing velocity during the closing phase has signifiant effects on pitting erosion.

Hydraulic Characteristic Analysis of Final Closing considering Non-Darcy Flow (Non-Darcy 흐름특성을 고려한 최종체절 수리특성분석)

  • Choi, Hung-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.8
    • /
    • pp.613-622
    • /
    • 2004
  • The simulation results of final closing by the developed model considering the flows through tide embankment of non-Darcy and through sluice gate agree well to the observed data which shows the model applicability. In comparative analysis with observed data, the simulation results by Homma(1958) are more accurate than those by Na(1987). The free flow equation with discharge coefficient, regardless of free or submerged flows, by Na based on the submergence ratio is applicable to the engineering practices. Because two simulated discharges are greater than the actual one, the correction of discharge coefficients reflecting the irregular section of actual closing gap situation is necessary. In the hydraulic analysis of final closing, the flow through tide embankment has been generally analysed by Darcy. Hydraulic analysis by the correct discharge through tide embankment of non-Darcy flow is necessary, because the ratio between flows through tide embankment and closing gap is relatively great at final closing.

A study on the determination of the instantaneous center of rotation pathway and the movement of the mandible by using the B-spline method (B-splint법에 의한 순간 회전 중심로 결정과 하악운동에 관한 연구)

  • Kang, Dong-Wan;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.1
    • /
    • pp.55-81
    • /
    • 1989
  • Recently the instantaneous center concept has been to understand the biomechanics by which a tissue derangement causes a mechanical derangement in human joint. Therefore, to understand the biomechanics of temporomandibular joint (T.M.J.) as a part of human joint, it is necessary to clarify the instantaneous center of rotation (I.C.R.) in the mandibular movement. Twenty male subjects without T.M.J. disorder and mandibular deviation during the mandibular movement were selected for this study. The habitual opening and closing paths were recorded on the paper of the sagittal metal plate by two pencil markers connected to the resin open clutch attached on the lower teeth, which was designed for this study. The coordinates of the 33-target points and the 109-anatomical landmarks were obtained using a Summagraphic digitizer connected to a 18AT computer. The original raw data of the opening and closing paths were smoothed by B-spline curve fitting technique and then the I.C.R. pathways were determined mathematically by the computer using algorithm for finding the I.C.R. of a planer rigid body model. Also the opening and closing movements of the mandible were simulated according to the determined I.C.R. The results obtained from this study were as follows. 1. At the early opening and the last closing, I.C.R's were almost distributed around the mastoid process outside the mandibular body without the presence in the region of the mandibular condyle. 2. The I.C.R. pathway showed variable patterns to each subject at the opening and closing movements. 3. The K constant with uniform pattern was obtained by the rotation angle times the radius, which was assumed to the index of the mandibular movement. 4. The opening and closing movements of the mandible were simulated by the I.C.R. pathways at the habitual opening and closing movements. 5. The mandibular condyle was rotated or translated accordng to the relative rotation angle and radius of the determinant factors of K contant.

  • PDF

Transient simulation and experiment validation on the opening and closing process of a ball valve

  • Han, Yong;Zhou, Ling;Bai, Ling;Xue, Peng;Lv, Wanning;Shi, Weidong;Huang, Gaoyang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1674-1685
    • /
    • 2022
  • The ball valve is an important device in the pipeline transportation system of nuclear power plants. Its operational stability and safety directly affect the normal working of nuclear power plants. In this study, the transient numerical simulation of the opening and closing process of a ball valve was conducted on the basis of the flow interruption capability experiment of the ball valve by using the moving mesh method and inlet and outlet variable boundary conditions. The flow rate and pressure difference with time of the opening and closing process of the ball valve were studied. The internal flow characteristics of the ball valve under different relative openings were analyzed in conjunction with the typical back-step flow structure. Results show that the transient numerical results agree well with the experimental results. The internal flow characteristics of the ball valve are similar at the same opening during opening and closing process. At small opening, the spool and outlet channels easily form a back-step flow structure. The disappearance and generation of backflow vortices during opening and closing occur at 85% opening and 75% opening, respectively. With the decrease in opening degree, the difference in vortex core area in the flow channel of the ball valve spool in the opening and closing process gradually appears. The research results provide some reference value for the design and optimization of ball valves.

Research and development of a three-stage door binder to improve the fire resistance of fire doors (방화문의 내화성능 향상을 위한 3단 문 결속기 연구개발)

  • Lim, Bo-Hyeok;Lee, Joo-Won;Cho, Dong-Hwan;Lee, Hae-Yeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.157-158
    • /
    • 2023
  • Doors that are opened and closed when entering or exiting a general building are connected to the door frame and open and close. They are equipped with door locking devices of various structures, and are either locked to the door frame for the closing operation or released from the door frame for the opening and closing operation. Here, a single-stage door binding device having a door latch that is independently disposed at the center of one axis of the door is commonly used. On the other hand, if the size of the door is over a certain size or if the door is medium to large, the opening and closing operation may not be performed smoothly with only a single stage binder, or the closing state may not be achieved stably during the closing operation. In particular, in the case of the single-stage binding device provided in medium to large fire doors, the door is fixed to the door frame unstable, causing fatal errors in the fire prevention function of the fire door. Accordingly, in order to fundamentally solve these problems, we researched and developed a three-stage door binding machine that combines a top and bottom fastening structure with a single-stage fastening structure. This 3-stage door binder not only has the fire resistance performance of a fire door, but also has a T-shaped terminal in its fastening method, so if you eliminate the upper and lower fastening, it is a 1-stage binder like a regular product, but if you remove the door latch of the 1st-stage binder, it functions as an upper and lower 2-stage binder and forms a single mold. We researched and developed a three-stage door binder that can manufacture and produce three products at the same time, satisfying both product performance and price.

  • PDF

Locational Analysis of Rural Industrial Estates and Chonbuk Economic Development Strategies (농공지구 입지분석 : 전라북도의 경우)

  • 박임구;백영기;장재우
    • Journal of the Korean Regional Science Association
    • /
    • v.9 no.2
    • /
    • pp.103-119
    • /
    • 1993
  • This research examines the spatial development of rural industrial estates (Nong-gong Jigu) in Chonbuk province and gives insight into the strategies for economic development in the entire region. Selected location factors which are likely to pull new investment into the estates are examined by using questionnaires. Few loction factors except nonlocal factors can be found in explaining why location choices are made. The irrelevance of the analysis based on location factors suggests that an alternative approach should analyze changes in the spatial development of the rural industrial estates. Such an alternative is to understand the dynamics of the spatial organization of production by focusing on characteistics of plant closing in the rural industrial estates. To take into account of the characteristics of plant closing we provide the hypothesized relationships between employment size, organizational structure, inter and intra industrial linkage, characteristics of production processes, and availability of local labor market and the likelihood of closing. A logit model is then made to identify the selected factors which might influence the probability of plant closing. The results from the logit analysis and their implications suggest that the policy should be more concerned with the characteristics of firms, such as size and ownership, as well as of the local labor markets. Given that the Chonbuk region has experienced rapid population decline, together with its poor industrial base, it seems that the success of the policy in the declined rural areas in less certain.

  • PDF

An Investigation of the Occlusal Sounds Produced by Mandibular Closing Movement in Adults (성인의 폐구운동시 발생되는 교합음에 관한 연구)

  • 신금배;이승우
    • Journal of Oral Medicine and Pain
    • /
    • v.8 no.1
    • /
    • pp.43-60
    • /
    • 1983
  • In order to obtain the basic data for diagnosis of occlusion the author investigated the occlusal sounds produced by mandibular closing movement from rest position to centric occlusion by using the Korotkoff sounds microphone electrodes and physiograph for Korean 20S without TMJ problems. And the author analyzed the correlation of the occlusal sounds with height, body weight, mandibular closing movement distance, maxillary sinus size and masseter muscle activities relating to the production of occlusal sounds. The obtained results were as follows : 1. The occlusal sounds prouduced by mandibular closing movements from rest position to centric occlusion were ranged from 3.08mV to 52.00mV, their maen value 19.07mV in right side, and ranged from 2.41mV to 18.33mV, their mean value 9.19mV in left side in group of Angel's class I occlusion subjects having right habitual side of mastication. 2. In general the occlusal sounds in the habitual side of mastication were greater than those in the opposite side. 3. The correlations of the occlusal sounds with height and maxillary sinus size were not significant. 4. The correaltions of the occlusal sounds with body weight, mandibular closing movement distance and masster muscle activities were significant.

  • PDF

Impact Behavior Analysis of a Mechanical Monoleaflet Heart Valve Prosthesis in the Closing Phase

  • Cheon, Gill-Jeong;Chandran, K.B.
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.285-298
    • /
    • 1992
  • An analysis of the dynamics in the closing phase of the occluder of a mechanical monoleaflet heart valve prosthesis is presented. The dynamic analysis of the fluid in the vicinity of the occluder was based on the control vo]use approach. The backflow velocity of the fluid was computed by applying the continuity, Bernoulli's and momentum equations in the unsteady state. By considering the fluid pressure and gravity as external forces acting on the occluder, the moment equilibrium on fine occluder was employed to analyze the motion of the occluder during closing and the force of impact between the occluder and the guiding struts. Occluder comes to rest after several oscillations in about 10-18 msec after the Inltiaton of closing. As the aortic pressure increases, the occludes closes faster and comes to the final resting position earlier and the impact force increases also. But backflow is not af footed by the variation of the aortic pressure. With decreasing time delay of the ventricle pressure, the occluder closes faster and impact force Increases. The computed magnitudes of the occluder tiP velocities as well as the backflow of the fluid during the closing phase using this model were in agreement with previously reported experimental measurements.

  • PDF

A Study on Combustion Characteristics of Spark-Ignited Engine with Different Late Intake Valve Closing for Miller Cycle (밀러사이클 적용 스파크점화기관의 후기 흡기밸브 닫힘각 변화에 따른 연소성능 연구)

  • Chung, J.H.;Kang, S.J.;Kim, J.S.;Jeong, S.C.;Lee, J.W.
    • Journal of ILASS-Korea
    • /
    • v.20 no.3
    • /
    • pp.141-148
    • /
    • 2015
  • In order to research engine characteristics of spark-ignited engine with intake valve closing timing change for Miller cycle, two cam for LIVC(Late Intake Valve Closing) were designed and fabricated an prototype valvetrain. And intake valve closing timing were adjusted to build low compressing and high expansion cycle for HEV. In experimental study, it were investigated with different engine speed, spark timing and air-fuel ratio to compare base cam and LIVC cam type. It was found that the volumetry efficiency and effective work of compression process were decreased in case of LIVC cam. When compared with the existing results, the maximum pressure in the cylinder was reduced about 12~13 bar and the volumetric efficiency was reduced about 16%.

Difficulty in Closing Mouth in Patient with Disc Displacement: A Case Report

  • Mun, Yo-Sun;Lim, Hyun-Dea;Lee, You-Mee;Kang, Jin-Kyu;Shim, YoungJoo
    • Journal of Oral Medicine and Pain
    • /
    • v.42 no.1
    • /
    • pp.16-19
    • /
    • 2017
  • Clinicians are familiar with limitation of opening mouth caused by temporomandibular disorders. Sometimes, patients also complain of difficulty in closing mouth. Difficulty in closing mouth can be caused by anterior, posterior disc displacement, and subluxation of temporomandibular joint (TMJ). In this report, we presented a patient who had a difficulty in both opening and closing mouth. The patient complained of TMJ noises and intermittent limitation of opening mouth, and inability to get teeth back into maximal intercuspal position. Magnetic resonance images revealed that the left TMJ had an anterior disc displacement with relative posterior disc displacement. We reviewed the possible causes, signs and symptoms, and treatment for difficulty in closing mouth with related literatures.