• 제목/요약/키워드: Closed test section

검색결과 72건 처리시간 0.024초

마이크로폰 어레이 측정에서의 도플러 효과와 자체소음 제거에 관한 실험적 연구 (Elimination of Self Noise & Doppler Effects from the Microphone Array Measurement)

  • 이욱;박성;최종수;김재무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.822-825
    • /
    • 2005
  • In the case of aeroacoustic test in windtunnel, measurement accuracy is reduced by not only Doppler effects but also by the microphone self noise due to airflow and high turbulence in the wall boundary layer. Microphone array measurements can be easily utilized for the solutions of these problems. In this paper, geometrical optics approach and diagonal term elimination of cross spectral matrix was introduced to the de-dopplerization and self noise reduction methods for the microphone array measurement. For the validation, beamforming tests for sinusoidal point source were performed in the closed type test section of windtunnel, and their performances of beam width and sidelobe rejection were significantly improved.

  • PDF

수평관내 $CO_2$의 초임계 영역내 열전달에 관한 연구 (The heat transfer characteristics of supercritical $CO_2$ in a horizontal tube)

  • 오후규;이동건;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.526-532
    • /
    • 2005
  • The cooling heat transfer coefficient of $CO_2$(R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter. a pre-heater and gas cooler(test section). The test section consists of a smooth, horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $400\;kg/m^{2}s$ and the inlet cooling pressure of 7.5 MPa to 10.0 MPa. The variation of heat transfer coefficient tends to decrease as cooling pressure of $CO_2$ increases. The heat transfer coefficient with respect to mass flux increases as mass flux increases. The pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with that predicted by Blasius's correlation. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Bringer-Smith.

HCFC-123의 수평 평활관내 응축 전열 특성에 관한 연구 (Condensation Heat Transfer Characteristics of HCFC - 123 inside Horizontal Smooth Tube)

  • 권옥배;오후규;오종택;김성규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권3호
    • /
    • pp.24-32
    • /
    • 1993
  • Experimental data on the heat transfer characteristics of HCFC-123 and CFC-11 during condensation in horizontal smooth tube are presented. The experimental apparatus consisted of a closed working fluid loop, coolant loop, and measuring system. The major components of the working fluid loop made of a refrigerant pump, boiler, superheater, refrigerant flow meter, receiver and test section. The tube-in-tube type test section was made of smooth tube which were constructed form 9.52 mm outer diameter of smooth copper tube with 50 mm outside diameter of PVC tube duct. The ranges of parameter, such as refrigerant mass velocity, coolant flow rate, and quality were 90-325kg/($m^2$.s), 60-360kg/h, 5-95% respectively. Data were obtained under steady state condition for annular flow. As a result of these, the condensation heat transfer coefficients for HCFC-123 were slightly lower than those of CFC-11 from 8% to 15% inside horizontal smooth tube. Furthermore, a new generalized correlation for the heat transfer coefficients of HCFC-123 and CFC-11 during condensation inside horizontal smooth tube is proposed.

  • PDF

풍력터빈 에어포일 주위의 벽면효과에 관한 연구 (A Study on Wall Interference Effect Around the Wind Turbine Airfoil)

  • 조환기;강승희;유기완;이준신
    • 한국항공우주학회지
    • /
    • 제40권6호
    • /
    • pp.485-491
    • /
    • 2012
  • 저 레이놀즈 수 조건에서 폐쇄형 풍동 시험부에 설치된 에어포일 주위의 벽면효과에 대한 실험적 연구를 수행하였다. 이를 위해 풍동시험이 수행되었으며, 시험은 자유흐름속도 10 ~ 31 m/s와 시위기준 레이놀즈 수 $1.5{\times}10^5{\sim}4.6{\times}10^5$ 조건에서 수행되었다. 시위대 시험부 폭 비인 기준폐쇄율은 27.8%, 38.5%, 41.7%, 45.5% 그리고 55.6%이다. 시험 결과 벽면효과에 의해 에어포일 표면에서의 천이점이 후방으로 미미하게 이동함을 확인하였다. 또한, 벽면압력을 이용한 벽면효과 보정을 위해서는 에어포일을 중심으로 시위의 세배 이상의 벽면압력이 필요함을 확인하였다.

다중채널 능동소음제어기법을 이용한 KTX 실내소음의 구간별 저감성능 비교 (KTX Interior Noise Reduction Performance Comparison Using Multichannel Active Noise Control for Each Section)

  • 장현석;김영민;이태오;이권순
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.179-185
    • /
    • 2012
  • Since the eco-era is getting closer, the importance of noise reducing in the passenger cars of high-speed train is very important. The active noise control is best choice to reduce low frequency noise because the passive one is too heavy for high speed trains where weight is so critical. Also ANC is able to reduce the ambient noise when the environmental-factor changes. To reduce a three-dimensional closed-space sound field like a car of a high-speed rail is hard to do using single channel ANC control system. We used multi-channel FXLMS algorithm which calculation speed is fast and the secondary path estimation is possible in order to take into account the physical delay in electro acoustic hardware control loudspeaker and power amplifier. Firstly, we have measured interior noise of KTX and estimated noise path in KTX test-bed. However there was some problem related to algorithm divergence and increasing the filter order. We have made a simulation of interior environment of KTX car by using three frequency bands of 120Hz, 280Hz, 360Hz as the most important for KTX ANC system. During this research the interior noise reduction of KTX car was made by using the multi-channel FXLMS algorithm. Reduction performance was evaluated and compared each other for open space section and tunnel section. in-situ experiment for the KTX noise reduction by proposed ANC was performed based on data obtained in simulation and they were compared for open space section and tunnel section as well.

사용종료 폐기물 매립장의 멤브레인 차수시스템 안정성 평가 (Evaluation of the Stability of Geomembrane Liner System in Closed Waste Landfill)

  • 이홍길;오영인
    • 한국지반신소재학회논문집
    • /
    • 제9권1호
    • /
    • pp.39-46
    • /
    • 2010
  • 최근 도시에 근접한 매립장은 인구밀집 지역과의 근접성, 부지개발에 따른 경제적 가치급등 등의 이유로 활용 가능한 새로운 건설부지로서의 관심이 집중되고 있다. 그러나 대부분의 사용 종료된 매립장은 매립장 내에 침출수의 누출방지를 위한 차수시스템이 바닥 및 사면부에 존치되어 있으며, 상부 부지의 재활용 설계 시 침출수 집배수 및 차수시스템의 안정성 평가를 실시하여 차수시스템 손상에 따른 지하수 주변지역 오염을 방지하여야 한다. 일반적으로 사용 종료된 폐기물 매립장의 차수시설은 매립장 운영과정에서 폐기물 덤핑에 따른 충격하중, 장비하중, 장기적인 매립폐기물 하중으로 인하여 인장강도변화 및 불규칙한 침하에 의한 손상이 발생될 수 있다. 본 연구에서는 사용종료매립장 부지의 재활용 시, 침출수의 누출방지를 위하여 기존 차수시스템 안정성 평가에 대한 연구를 수행하였다. 기존 사용종료매립장의 차수시스템의 안정성 및 손상여부를 평가하기 위하여 굴착 샘플링 시료에 대한 인장강도 시험 및 현장 추적자 조사를 실시하였다. 현장시료에 대한 인장강도 시험 결과, 항복인장강도는 시방기준 및 현행 폐기물관리법 설치기준에 적정하였으나, 추적자 조사결과, 위생매립구간 차수쉬트의 손상이 확인되었다.

  • PDF

세관내 이산화탄소의 증발 열전달 및 압력강화 (Evaporation Heat Transfer and Pressure Drop of $CO_2$ in a Small diameter Tube)

  • 장승일;최선묵;김대희;박기원;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.189-194
    • /
    • 2005
  • The evaporation heat transfer and pressure drop of $CO_2$ in a small diameter tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 4.57 mm, and length of 4 m. The experiments were conducted at mass flux of 200 to 700 $kg/m^2s$, saturation temperature of $0^{\circ}C$ to $20^{\circ}C$, and heat flux of 10 to 20 $kW/m^2$ . The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The evaporation pressure drop of C02 are highly dependent on the mass flux. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient and pressure drop of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient and friction pressure drop of $CO_2$ in a horizontal tube.

  • PDF

내경 4.57과 7.75 mm인 수평관내 이산화탄소의 증발 압력강하 (Evaporation Pressure Drop of Carbon Dioxide in Horizontal Tubes with Inner Diameter of 4.57 mm and 7.75 mm)

  • 손창효
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.30-37
    • /
    • 2008
  • The evaporation pressure drop of $CO_2$ (R-744) in horizontal tubes was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 7.75 and 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The pressure drop measured during the evaporation process of $CO_2$ increases with increased mass flux, and decreases as the saturation temperature increased. The evaporation pressure drop of $CO_2$ is very lower than that of R-22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the correlation of Choi et al. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

Evaporation Heat Transfer Characteristics of $CO_2$ in a Horizontal Tube

  • Lee Dong-Geon;Son Chang-Hyo;Oh Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.297-305
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver. a variable-speed pump. a mass flow meter. a pre-heater and evaporator (test section). The test section consists of a smooth. horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500\;kg/m^{2}s$. saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$. and heat flux of 10 to $40\;kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has greatly effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality. heat flux and saturation temperature. The evaporation heat transfer coefficient of $CO_2$ is very larger than that of R-22 and R-134a. In making a comparison between test results and existing correlations. the present experimental data are the best fit for the correlation of Jung et al. But it was failed to predict the evaporation heat transfer coefficient of $CO_2$ using by the existing correlation. Therefore. it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

Evaporation Heat Transfer Characteristics of $CO_2$ in a Horizontal Tube

  • Son Chang-Hyo;Kim Dae-Hui;Choi Sun-Muk;Kim Young-Ryul;Oh Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권4호
    • /
    • pp.167-174
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500kg/m^2s$, saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has greater effect on nucleate boiling than convective boiling. The evaporation heat transfer coefficient of $CO_2$ is highly dependent on the vapor quality, heat flux and saturation temperature. The evaporation heat transfer coefficient of $CO_2$ is very larger than that of R-22 and R-134a. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the correlation of Jung et al. But the existing correlations failed to predict the evaporation heat transfer coefficient of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.