• Title/Summary/Keyword: Closed system and Open system

Search Result 514, Processing Time 0.037 seconds

A Study on the Voltage Stability Enhancement in Radial Power System (방사상 전력계통의 전압안정도 향상에 관한 연구)

  • Kim, Byung-Seop;Jeong, Yun-Won;Park, Jong-Bae;Shin, Joong-Rin;Chae, Myung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.87-89
    • /
    • 2002
  • This paper presents a new approach using an Improved branch exchange (IBE) technique to maximize the voltage stability as well as loss minimization in radial power systems. A suitable voltage stability index (VSI) for optimal routing algorithm is developed using novel methods both a critical transmission path based on a voltage phasor approach and an equivalent impedance method. Furthermore, the proposed algorithm can automatically detect the critical transmission path to be reached to a critical load faced with voltage collapse due to additional real or reactive leading. To develop an effective optimization technique, we also have applied a branch exchange algorithm based on a newly derived index of loss change. The proposed IBE algorithm for VSI maximization can effectively search the optimal topological structures of distribution feeders by changing the open/closed states of the sectionalizing and tie switches. The proposed algorithm has been tested with the various radial power systems to show its favorable performance.

  • PDF

Design of a Model-based Controller for a 6-DOF Precision Positioning Stage using $H_{\infty}$ norm ($H_{\infty}$ norm을 이용한 6 자유도 정밀스테이지의 모델기반 제어기 설계)

  • Moon, Jun-Hee;Lee, Bong-Gu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.12
    • /
    • pp.59-66
    • /
    • 2010
  • We developed a model-based controller for 6-DOF micropositioning of a precision stage using $H_{\infty}$ norm, For the design, a state-space system of the mathematical model of the stage is derived In developing the controller, weighting functions are effectively designed in consideration of upper bounds of the sensitivity of the control loop and control input. Step responses in open and closed loop control are provided to verify the micropositioning performance of the stage. By applying the developed controller we prove that the inverse of the weighting function forms the upper bound of the control loop. It is also found that the controller makes the same sensitivity shape with all the DOFs due to the use of $H_{\infty}$ norm. The developed controller is expected to be applied successfully for industrial use.

Characteristics of Power Generation and Organic Matter Removal in Air-Cathode MFC with respect to Microbial Concentration (미생물 농도에 따르는 Air-Cathode MFC의 전력발생과 유기물질제거 특성)

  • Kim, Doyoung;Lim, Bongsu;Choi, Chansoo;Kim, Daehyun
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.917-922
    • /
    • 2012
  • In order to improve applicability of a microbial fuel cell the laboratory-scaled study has been performed by adopting an air-cathode MFC system with high concentrated anaerobic slugies in this study. The concentrations of microbes are grouped into three types, Type A (TS 1.7%), Type B (TS 1.1%) and Type C (TS 0.51%). The open circuit voltage $(V_{oc})$ characteristics showed that the medium microbes concentration of 1.10% (Type B) kept a constant voltage of 1.0 V for 150 hours, which showed the longest time among three types (Type A and Type C). The discharge charge curves for a closed circuit with $500 \Omega$ also showed that Type B generated a stable discharge voltage of 0.8 V for a longer time as in the open circuit voltage case. This could be explained by the relatively large amount of the attached microbes. Under the $V_{oc}$condition the COD removal efficiency of Type B was found to be low for a long time, but those of Type A and C were found to be high for a short period of time. Therefore, the suspended microbes could decrease the coulombic efficiency. It was concluded that the high $V_{oc}$ was caused by low COD and the $V_{oc}$ became low after the COD removal. The COD reduction resulted in an unstable and low working voltage. From the polarization characteristics Type A was found to show the highest power density of $193\;mW/m^2$ with a fill factor of 0.127 due to the relatively high remaining COD even after the MFC reaction.

The Relationship between the User's Perception of Socio-cultural Attributes and the Spatial Structures of Dwelling Spaces - a Comparative Study between Korean and German Housings - (거주자의 대 사회적 개념과 주거공간의 영역별 구성체계와의 관계 - 한국과 독일의 주거형태학적 비교관찰을 통하여 -)

  • 전남일
    • Journal of the Korean housing association
    • /
    • v.13 no.5
    • /
    • pp.31-42
    • /
    • 2002
  • This comparative study between Korean and German housings aims at understanding different structural systems in the indoor and outdoor spaces, depending upon the user′s perception of the socio-cultural attributes. The analysis starts with four alternative contrary assumptions, that appear in morphological forms of dwelling; 1) linear distribution vs. areal distribution of residential districts, 2) mirror system vs. comb system in the layout of plot plans 3) organization of front vs. back outdoor spaces and 4) opening vs. closing in the indoor spaces. A clear difference is found between Korean and German samples in view of public and private relationships between indoor and outdoor spaces as well as the intermediate space. In the korean housing there always exists a symbolic and psychological territory of a certain sphere. On the other hand, outdoor space passes through various phases only to form a certain hierarchy even in a private space and, thereby, sets a boundary between private and public areas. In the case of Germany, the building itself draws a clear line between private and public outdoor spaces, and therefore the outdoor space has a "front" and "back". Thus, Germany′s private space may face a genuine public space and street, which is rare in the Korean housing. Although the layout of indoor space in the korean housing tends to be open, such an openness may be outstanding in living and dining spaces, kitchen and various accesses to rooms. In the case of Germany, such indoor spaces are usually closed to each other. Thus corridors act to separate these spaces. Such differences are analysed to be due to the different perceptions of interpersonal and socio-cultural attributes as intra-family and inter-neighbor relationships or communications.

A Study on the Architectural Planning of Nurseries - With emphasis on planning of spatial organization - (보육시설의 건축계획에 관한 연구 - 공간구성계획을 중심으로 -)

  • Chung, Ji-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.5 no.1
    • /
    • pp.33-43
    • /
    • 1998
  • With increased social participation of married women and with the notion of importance of pre-school childhood on human development, the importance of nurseries is being emphasized. The transformation of the traditional family system into a nuclear family system and the deterioration of the traditional child education have also put nurseries as a primal social interest. But, at present, at the end of 1994, only 10% of the children have benefitted from such facilities, the supply not being able to meet demand. Also, the spatial organization and the management of such facilities has been unsatisfactory. In this perspective, this study aims to grasp the present condition of nurseries, to investigate and analyse case studies, to suggest standards and reform measures, and based on these, to produce basic information for the formation of an architectural spatial model. We've selected investigation of present conditions and case studies, interviews, and observation as investigative methods and through these we've assessed tangible spatial planning and spatial proportion by parts. 1. The most preferred grouping method is toddler/preschooler type, and the group size and staff-to-child ratios vary according to the children's age 2. The younger children's activity rooms are located in the lower level, and the activity room of the children on the similar development stages are located adjacent to one another 3. Most of the facilities do not have the public spaces(indoor playrooms, dinning rooms, napping rooms, bathrooms, sickrooms) For dinning and napping, activity rooms are being used, and for sickrooms, director's room or staff rooms 4. As for the correlations of the spaces(home bases, activity rooms and its outdoor spaces, day-care-centers and its community), closed plan type is 90% over, and modified open plan is 10% min.

  • PDF

A Study on Investment Agreement and Dispute Resolution System of FTA (FTA 투자협정과 분쟁해결제도에 관한 연구)

  • Choe, Tae-Parn
    • Journal of Arbitration Studies
    • /
    • v.17 no.2
    • /
    • pp.141-165
    • /
    • 2007
  • This study aims to make a contribution to the promotion of trade and economic development of South Korea, and, at the same time, call attention to the increasing trend of investment agreements concluded within Free Trade Agreements (FTA) by examining theoretically FTAs and dispute resolution and investigating systematically the conclusion procedure of agreements, and the system, institutions, and jurisdiction of dispute resolution, and presenting these findings to the government and investors involved. The most problematic aspect in the legal process of arbitration involving disputes over investment is that of arguments concerning the right of jurisdiction. When a dispute arises, even though an investor files for arbitration at an ICSID institution, the parties become involved in another energy-consuming argument even before proceeding to the hearing and decision of the original plan in cases in which the respondent of the dispute files an objection to the decision rights of the arbitral tribunal. As the main basis for this type of plea, the point of non-existence of jurisdiction is first raised where the applicable dispute does not fall under the range of investments defined in individual investment contracts or investment agreements such as a Bilateral Investment Treaty (BIT). To avoid an open-ended definition of investment for the range of investments, articles concerning investments in the FTA and NAFTA between Canada and the USA adopt the limited closed-list method. Article 96 of the FTA between Japan and Mexico applied the same abovementioned method of limited form of definition regarding range of investments and concluded BITs between member countries of APEC applied a similar method as well. Instead of employing the previously used inclusive definition, the BITs concluded between countries of Latin America and the USA are equipped with limited characteristics of an investment. Furthermore, to correspond with this necessary condition the three following requirements are needed : 1) fixed investment funding; 2) expected profits resulting from such investments; 3) and the existence of fixed risk bearing.

  • PDF

Effects of Half Squats with Kinesio Taping on Trunk and Lower Extremity Muscle Activity and Balance Ability in University Students (키네시오 테이핑을 병행한 하프 스쿼트 훈련이 일반인의 몸통과 다리 근활성도 및 균형능력에 미치는 영향)

  • Kim, Kyung-Hun
    • PNF and Movement
    • /
    • v.20 no.2
    • /
    • pp.253-262
    • /
    • 2022
  • Purpose: The aim of this study was to identify the effects of performing the half squat exercise with Kinesio taping (HSEKT) on trunk and lower extremity muscle activity and balance ability in general university students. Methods: The 32 participants were randomly assigned to either the HSEKT group (half squats with Kinesio taping) or the control group (half squats with sham Kinesio taping). Both groups performed half squats with either Kinesio taping (HSEKT group) or sham Kinesio taping (control group) for 30 min/day, 3 times/week for 6 weeks. The Noraxon mini direct transmission system (DTS) electromyography (EMG) system was used to evaluate trunk and lower extremity muscle activity. BioRescue equipment was used to measure the movement area of the center of pressure with eyes open and eyes closed. The muscle activity of the trunk and lower extremities and the balance ability of all participants were measured before and after the intervention. An independent t-test was used to statistically analyze the pre- and post-intervention EMG and balance ability results. Results: The trunk and lower extremity muscle activity was found to have significantly improved in the HSEKT group and the control group after the intervention (p < 0.05). Also, the balance ability of the HSEKT group differed significantly after 6 weeks of training compared to that of the control group (p < 0.05). Conclusion: The findings of this study show that performing half squats with Kinesio taping had a positive effect on trunk and lower extremity muscle activity and balance ability in general university students.

A Study on Communication Safety and Evaluation Tool in Railway Communication System (열차제어시스템 통신 안정성 및 평가 도구 연구)

  • Kim, Sung-Un;Seo, Sang-Bo;Song, Seung-Mi;Jo, Chan-Hyo;Hwang, Jong-Gyu;Jo, Hyun-Jeong
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.4
    • /
    • pp.349-356
    • /
    • 2008
  • Put Safety-critical systems related to the railway communications are currently undergoing changes. Mechanical and electro-mechanical devices are being replaced by programmable electronics that are often controlled remotely via communication networks. Therefore designers and operators now not only have to contend with component failures and user errors, but also with the possibility that malicious entities are seeking to disrupt the services provided by theirs systems. Recognizing the safety-critical nature of the types of communications required in rail control operations, the communications infrastructure will be required to meet a number of safety requirements such as system faults, user errors and the robustness in the presence of malicious attackers who are willing to take determined action to interfere in the correct operation of a system. This paper discusses the safety strategies employed in the railway communications and proposes a security mechanism for Korean railway communication system. We present the developed communication safety evaluation tool based on the proposed security mechanism and also evaluate its protecting capability against the threats of masquerading, eavesdropping, and unauthorized message manipulation.

Characterization of Area Installing Combined Geothermal Systems : Hydrogeological Properties of Aquifer (복합지열시스템에 대한 부지특성화: 대수층의 수리지질학적 특성)

  • Mok, Jong-Koo;Park, Yu-Chul;Park, Youngyun;Kim, Seung-Kyum;Oh, Jeong-Seok;Seonwoo, Eun-Mi
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.293-304
    • /
    • 2017
  • This study was performed in order to hydrogeological analysis of aquifer, which is a necessary part for evaluating the efficiency of the combined well and open-closed loops geothermal (CWG) systems. CWG systems have been proposed for the effective utilization of geothermal energy by combining open loop geothermal systems and closed loop geothermal systems. Small aperture CWG systems and large aperture CWG systems were installed at a green house land with water curtain facilities in Chungju City. Aquifer tests include pumping tests and step-drawdown tests were conducted to analyse hydrogeological characteristics of aquifer in the study area. The transmissivity was estimated in the range of $13.49{\sim}58.99cm^2/sec$, and the storativity was estimated in the range of $1.13{\times}10^{-5}{\sim}5.20{\times}10^{-3}$. The geochemical analysis showed $Ca^{2+}$ ion and ${HCO_3}^-$ ion were dominant in groundwater. The Langelier Saturation Index and the Ryznar Stability Index showed low scaling potential of groundwater. In the analysis of vertical water temperature change, the geothermal gradient was estimated as $2.1^{\circ}C/100m$, which indicated the aquifer was enough for geothermal systems. In conclusion, groundwater is rich, can stably use geothermal heat, and it is less likely to cause deterioration of thermal energy efficiency by precipitation of carbonate minerals in study area. Therefore, the study area is suitable for installation of the combined geothermal system.

A Characteristic of Freeze and Thaw on Use for Stabilized Soil in Landfill Bottom Liners (매립지 바닥층의 고화토 포설시 동결/융해의 특성)

  • Kim, Heung-Seok;Lee, Song;Lee, Jai-Young
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.1
    • /
    • pp.29-39
    • /
    • 2006
  • Recently, Korea brings to remarkable levels about industrialization, modernization, population and development of technology. Especially, the rapidly growing from this technology has increased the burden on existing industrial waste landfills. The purpose of this research is to existing knowledge base of landfill cover liner behavior during periods freeze/thaw. Although these tests have been invaluable in clarifying the problem of freeze/thaw, extending the results of such experimental studies to prototype landfills are questionable. For this investigation, the author utilized a large scale laboratory simulation allowing inclusion of the field depth of the cover systems, layered soil profiles, rainfall simulation, a cold climate and boundary conditions similar to those encountered in the landfill. And the soil materials used stabilized soils (mixed clays, cements, and minerals) instead of clays. The bottom liners are made up of drainage layer (30cm), stabilized layer (75cm), and leach collection layer (60cm). The stabilized layers are made up of supporting layer (45cm) and impermeable layer (30cm) - consisted of $P_A$ and $P_B$ layer.

  • PDF