• Title/Summary/Keyword: Closed system and Open system

Search Result 514, Processing Time 0.029 seconds

Open API Software Framework for Information Processing of RCS-e Presence Feature (RCS-e 프레즌스 정보 처리를 위한 오픈 API 소프트웨어 프레임워크)

  • Lee, Dongcheul
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.5
    • /
    • pp.77-82
    • /
    • 2016
  • Web developers have had difficulties in using Rich Communication Service-e(RCS-e) on their applications because of complicated protocols and closed interfaces. In order to vitalize the use of RCS-e, we need a RCS Application Program Interface(API) which has simple protocols and can be accessed easily. This paper presents the web-based Open API Framework for the RCS-e presence feature. A system architecture for the framework is defined. Call flows for the presence feature between the framework and other nodes are defined. Also, one of the call flows is illustrated to explain how to convert web-based requests to RCS-e requests. Finally, performance evaluation proves that the framework does not add any loads to the existing network infrastructure.

Systematizing Information Use to Address Determinants of Health Worker Health in South Africa: A Cross-sectional Mixed Method Study

  • Muzimkhulu Zungu;Annalee Yassi ;Jonathan Ramodike;Kuku Voyi;Karen Lockhart;David Jones;Spo Kgalamono;Nkululeko Thunzi;Jerry Spiegel
    • Safety and Health at Work
    • /
    • v.14 no.4
    • /
    • pp.368-374
    • /
    • 2023
  • Background: Recognizing that access to safe and healthy working conditions is a human right, the World Health Organization (WHO) calls for specific occupational safety and health (OSH) programs for health workers (HWs). The WHO health systems' building blocks, and the International Labour Organization (ILO), highlight the importance of information as part of effective systems. This study examined how OSH stakeholders access, use, and value an occupational health information system (OHIS). Methods: A cross-sectional survey of OSH stakeholders was conducted as part of a larger quasi experimental study in four teaching hospitals. The study hospitals and participants were purposefully selected and data collected using a modified questionnaire with both closed and open-ended questions. Quantitative analysis was conducted and themes identified for qualitative analysis. Ethics approval was provided by the University of Pretoria and University of British Columbia. Results: There were 71 participants comprised of hospital managers, health and safety representatives, trade unions representatives and OSH professionals. At least 42% reported poor accessibility and poor timeliness of OHIS for decision-making. Only 50% had access to computers and 27% reported poor computer skills. When existing, OHIS was poorly organized and needed upgrades, with 85% reporting the need for significant reforms. Only 45% reported use of OHIS for decision-making in their OSH role. Conclusion: Given the gap in access and utilization of information needed to protect worker's rights to a safe and healthy workplace, more attention is warranted to OHIS development and use as well as education and training in South Africa and beyond.

Prediction of the Following BCI Performance by Means of Spectral EEG Characteristics in the Prior Resting State (뇌신호 주파수 특성을 이용한 CNN 기반 BCI 성능 예측)

  • Kang, Jae-Hwan;Kim, Sung-Hee;Youn, Joosang;Kim, Junsuk
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.9 no.11
    • /
    • pp.265-272
    • /
    • 2020
  • In the research of brain computer interface (BCI) technology, one of the big problems encountered is how to deal with some people as called the BCI-illiteracy group who could not control the BCI system. To approach this problem efficiently, we investigated a kind of spectral EEG characteristics in the prior resting state in association with BCI performance in the following BCI tasks. First, spectral powers of EEG signals in the resting state with both eyes-open and eyes-closed conditions were respectively extracted. Second, a convolution neural network (CNN) based binary classifier discriminated the binary motor imagery intention in the BCI task. Both the linear correlation and binary prediction methods confirmed that the spectral EEG characteristics in the prior resting state were highly related to the BCI performance in the following BCI task. Linear regression analysis demonstrated that the relative ratio of the 13 Hz below and above the spectral power in the resting state with only eyes-open, not eyes-closed condition, were significantly correlated with the quantified metrics of the BCI performance (r=0.544). A binary classifier based on the linear regression with L1 regularization method was able to discriminate the high-performance group and low-performance group in the following BCI task by using the spectral-based EEG features in the precedent resting state (AUC=0.817). These results strongly support that the spectral EEG characteristics in the frontal regions during the resting state with eyes-open condition should be used as a good predictor of the following BCI task performance.

A Study on the Policy Proposal and Model B2B2C for Safe Open Banking (안전한 오픈뱅킹 구축을 위한 정책 및 B2B2C 모델에 관한 연구)

  • Choi, Dae-Hyun;Kim, In-Seok
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.6
    • /
    • pp.1271-1283
    • /
    • 2019
  • The fourth industrial revolution and digital transformation are also bringing major changes to the financial ecosystem in Korea. Already, global financial firms overseas are opening their financial markets and exploring new financial businesses by seeking ways to co-prosperity with fintech firms. However, it is also true that the domestic financial environment has failed to respond to the changes due to its monopolistic and closed structure. In response, the government began pushing for the introduction of open banking in December 2019 with the aim of fully opening the financial settlement system. However, unlike the existing simple financial transaction structure, open banking still has an unresolved part due to the unclear relationship of responsibilities between interested parties in the event of financial accidents due to the complex linkage structure of transactions such as financial firms, fintech firms and customers. This study analyzed the security threat of open banking in depth. By doing so, the government and financial firms want to present policy proposals that need to be improved to enhance the safety of open banking in korea and protect financial consumers, as well as new financial models that have improved the vulnerable parts of existing models.

A Study on Comparison of the Characteristic Test of Discharge Water Flowmeters (Electromagnetic Flowmeter, Parshall Flume) (방류수 유량계(전자기유량계, 파샬플룸)의 특성평가 연구)

  • An, Yang-ki;Kim, Jee-young;Kim, Kum-hee;Jang, Hee-soo;Jung, Jung-pil;Choi, Jong-woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.57-62
    • /
    • 2015
  • The test of comparing liquid flow calibration system (approved by KOLAS) for accuracy and structure change test was performed in the test bed in order to evaluate the typical characteristics of the electromagnetic flow meters and parshall flume that are generally used in the water discharging facilities. The results of the accuracy comparing test with liquid flow calibration system showed the error of less than 2%. Pharshall plume got error up to -8.3% (low flow) from the flow rate test, but less than 4% from the accumulated flow test because of offset error at high flow rate and low flow rate. Evaluation of structual change test was tested with only parshall flume using structure and it consisted of installation angle (parshall flume and level sensor) and position change. Installation angle, water level sensor angle and position changing test for parshall flume had errors of 3.1%~-9.2%, 0.4%~-5.6% and 0.2%~1.3% respectively. Especially, the error showed the largest increase when the water level sensor measured the point of decreased flow by the structure change. Therefore, error factors (change of straight pipe length, installation of obstacle or effect of foreign substances on water level sensor) that can often occur in the field should be derived and the research for optimized installation method should be carried out continuously.

A Study on the Retention Efficiency of Library Materials of Automated Storage and Retrieval System (자동서고의 자료 수장 효율성에 관한 연구)

  • Kim, Young-Seok
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.49 no.3
    • /
    • pp.437-456
    • /
    • 2015
  • This study aims to compare the retention efficiency of library materials of Automated Storage and Retrieval System(AS/RS) revealed by the literature review to other types of book stacks. Domestic and foreign academic libraries adopted AS/RS as part of a plan to improve the retention efficiency. Literature review reveals that in general, AS/RS is better in the retention efficiency in compare to other types of book stacks. This study compared the amount of library materials stored by the AS/RS of S University Library to the general book stack and the fixed-type and the mobile rack-type of virtual book stacks. The study reveals that AS/RS is up to 6 times more efficient than general book stacks, up to 3.61 times more efficient than fixed-type book stacks and up to 1.45 times more efficient than mobile rack-type book stacks. However, the study claims that the retention efficiency of library materials of AS/RS is lower than what is known.

Reduction of Computing Time in Aircraft Control by Delta Operating Singular Perturbation Technique (델타연산자 섭동방법에 의한 항공기 동력학의 연산시간 감소)

  • Sim, Gyu Hong;Sa, Wan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.3
    • /
    • pp.39-49
    • /
    • 2003
  • The delta operator approach and the singular perturbation technique are introduced. The former reduces the round-off error in the numerical computation. The latter reduces computing time by decoupling the original system into the fast and slow sub-systems. The aircraft dynamics consists of the Phugoid and short-period motions whether its model is longitudinal or lateral. In this paper, an approximated solutions of lateral dynamic model of Beaver obtained by using those two methods in compared with the exact solution. For open-loop system and closed-loop system, and approximated solution gets identical to the exact solution with only one iteration and without iteration, respectively. Therefore, it is shown that implementing those approaches is very effective in the flight dynamic and control.

A Study on the Efficiency of Logistics Systems through the Operation of a Freight Car Sharing Information System among Companies (화물차 공유를 통한 물류효율화 방안에 관한 연구)

  • Kim, Byeong-Chan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.10
    • /
    • pp.197-205
    • /
    • 2014
  • This study set out to develop a logistics rationalization model to reduce logistics costs including return route costs by using open information systems that overcame the limitations of the old closed logistics systems by the corporations and applying the principle of freight car sharing among them. In recent years, information infrastructure that can be easily shared by many such as information networks, however, One of the causes of rising logistics costs is high empty transfer rates on return routes after goods are transported from the distribution center of each company to consumption sites, It is propose to promote logistic efficiency and innovation. The study especially identified a logistics rationalization plan by examining and analyzing the stages of transportation on the circulation route of a distribution system from the distribution center of a corporation to consumption sites and the empty transfer rates and their current state.

Control System of Turbofan Engine with Variable Inlet Guide Vane (가변 안내익을 이용한 터보팬 엔진 제어시스템)

  • Bae, Kyoungwook;Min, Chanoh;Cheon, Bongkyu;Lee, Changyong;Lee, Daewoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.3
    • /
    • pp.237-242
    • /
    • 2014
  • Surge phenomenon can be occurred in a compressor when the performance of turbofan engine for an aircraft is changed considerably such as take-off phase. This study is aimed to avoid surge phenomenon. This paper propose the PID and Fuzzy control System for the turbofan engine with control inputs, the VIGV(Variable Inlet Guide Vane) in closed loop, and the fuel mass flow in open loop. We design the Dynamic modeling, NPSS S-function, which is connection block of simulink between NPSS(Engine analysis program) and Simulink. Finally, we certify the performance to prevent a serge phenomenon in the VIGV control system using the both methods, PID and fuzzy.

A Study of Over Voltage Ground Relay Operation Status at Opening of No-load Charged Cable (무부하 충전케이블 개방시 잔류전압에의한 과전압계전기 동작현상 연구)

  • Kim, Yeong-Han;Choi, Jong-Hyuck;Yoon, Ki-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.185-187
    • /
    • 2000
  • Fault current is flowed into 154/23kV M. Tr when line-to-ground fault occurs in power system. NGR(Neutral Grounded Reactor) is set up in order to prevent M.Tr fault by limiting magnitude of fault currents. Here, disconnection of NGR causes voltage increase by L-C resonance and line-to-ground fault in an unearthed system results in voltage increase at healthy phases. So Over Voltage Ground Relay(OVGR) is used for tripping M.Tr. Also, buses at second phases of M.Trs are all connected with section circuit breakers closed for the purpose of parallel operation and load shedding. In case of speciality buses are comprised of power cable in part for GIS connection. When no-load charged cable or bus is open by a section CB, unbalanced voltage charged on the bus is induced. Also discrepant opening time for circuit breakers on different phases gives rise to unbalanced zero sequence voltage. It was observed that this zero sequence voltage detected in the 22.9kV P.T (Potential Transformer for bus) mal-operated 59GT and tripped M.Tr. The zero sequence voltage of which vanishing time is longer than relay operating time came out by EMTDC simulation. Also, it was shown that the voltage waves of actual test are similar to those of simulation. On the basis of above results, R-C circuit complement on the relay without any effect on a power system made operating time of the relay longer than vanishing time of distorted waves. Consequently, operating time of the relay was delayed and magnitude of distorted waves was decreased by increasing time constant of the relay.

  • PDF