• Title/Summary/Keyword: Closed center valve

Search Result 25, Processing Time 0.025 seconds

Development of a PWM controller for the pneumatic actuation system (공압구동장치를 위한 PWM 제어기 설계)

  • 이동우;안병홍;문의준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.7-12
    • /
    • 1989
  • This paper describes the design and development of a PWM electronic controller for a high performance Pneumatic Actuation System. The task includes the design of a closed center valve circuit for minimum gas consumption, the selection of optimum values for key parameters in the PWM circuit, and the design of lag-lead compensation circuit. These were carried out through specific experiments using a prototype pneumatic actuation system. The final performance obtained with the actuation system confirmed the successful design of the developed PWM electronic controller.

  • PDF

Design of Controllers for the Stable Idle Speed in the Internal Combustion Engine

  • Lee, Young-Choon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.2 no.4
    • /
    • pp.54-60
    • /
    • 2001
  • This paper deals with control design method having anticipation delay which is proposed for the discrete nonlinear engine where system dynamics is not accurate. Due to the induction-to-power delay in internal combustion(IC) engine having abrupt torque loss, underdamping and chattering in engine idle speed becomes a serious problem and it could make drivers uncomfortable. For this reason, Three types of the closed-loop controller are developed for the stable engine idle speed control. The inputs of the controllers are an engine idle speed and air conditioning signal. The output of the controllers is an duty cycle to operate the idle speed control valve(ISCV). The proposed controllers will be useful for improving actual vehicles since these shows good test

  • PDF

Development of a Peristaltic Micropump with Lightweight Piezo-Composite Actuator Membrane Valves

  • Pham, My;Goo, Nam-Seo
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.12 no.1
    • /
    • pp.69-77
    • /
    • 2011
  • A peristaltic micropump with lightweight piezo-composite actuator (LIPCA) membrane valves is presented. The micropump contained three cylinder chambers that were connected by microchannels and two active membrane valves. A circular miniature LIPCA was developed and manufactured to be used as actuating diaphragms. The LIPCA diaphragm acted as an active membrane valve that alternate between open and closed positions at the inlet and outlet in order to produce high pumping pressure. In this LIPCA, a lead zirconium titanate ceramic with a thickness of 0.1 mm was used as an active layer. The results confirmed that the actuator produced a large out-of-plane deflection. During the design process, a coupled field analysis was conducted in order to predict the actuating behavior of the LIPCA diaphragm; the behavior of the actuator was investigated from both a theoretical and experimental perspective. The active membrane valve concept was introduced as a means for increasing pumping pressure, and microelectromechanical system techniques were used to fabricate the peristaltic micropump. The pumping performance was analyzed experimentally in terms of the flow rate, pumping pressure and power consumption.

Bio-Monitoring System Using Shell Valve Movements of Pacific Oyster (Crassostrea gigas) -I. Detecting Abnormal Shell Valve Movements Under Low Salinity Using a Hall Element Sensor (굴(Crassostrea gigas)의 패각운동을 이용한 생물모니터링시스템 연구 -I. 홀 소자를 이용한 저염분하에서 비정상적인 패각운동 측정)

  • Oh, Seok Jin;Lee, Jun-Ho;Kim, Seok-Yun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.2
    • /
    • pp.138-142
    • /
    • 2013
  • As an early warning system to reduce the damage of aquacultured mollusks due to low salinity water, we investigated the possibility of a biomonitoring system measuring the shell valve movement (SVM) of Pacific oyster (Crassostrea gigas) by using the Hall element sensor. In high salinity water of 27 psu, SVMs of Pacific oyster showed spikes which mean a relatively fast closing condition after opened condition of average 10-15 mm, and then the SVM showed back to opening condition slower than closing speed. In water salinity of 20-27 psu, the SVMs were similar to that of 27 psu. However, below 17 psu, it showed abnormal valve movements such as spending more time for shell closure. In 10 psu, we could not detected SVMs due to closed condition during experiment periods. Thus, if we quickly detect abnormal environmental variations like low salinity using bio-monitoring of SVM, it may be contribute to increased productivity by dramatically reducing damages in aquaculture.

Study on Evaluation Method of Flow Characteristics in Steady Flow Bench(3) - Velocity Profile(1) (정상유동 장치에서 유동 특성 평가 방법에 대한 연구(3) - 유속분포(1))

  • Park, Chanjun;Sung, Jaeyong;Ohm, Inyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.2
    • /
    • pp.169-182
    • /
    • 2016
  • This paper is the third investigation on the evaluation methods of flow characteristics in a steady flow bench. In the previous works, several assumptions used in the steady flow bench were examined and the flow characteristics were estimated both by the conventional impulse swirl meter and a particle image velocimetry at 1.75B position. From these works, it was concluded that the assumption of the solid rotation might cause serious problems and both of the eccentricity and the velocity profile distort the flow characteristics when using the ISM at 1.75B plane. Therefore, the understanding of the detail velocity profiles is very important to keep discussing the issues about the steady flow evaluation method. For this purpose, the planar velocity profiles were measure at 1.75B position by particle image velocimetry and the characteristics were examined according to the valve angles and lifts. The results show that the planar velocity profiles of 11, 16, $21^{\circ}$ valve angle heads according to the lift are similar to each other, however, that of $26^{\circ}$ angle is an exceptional case in the all aspects. In addition, the swirl behaviors are not apparent up to 6~8 mm lift under the $21^{\circ}$ angle and somewhat arranged motions are observed over the whole plane near the highest lift. At this point, the narrower the angle, the lower the lift at which the swirl motions become clear. On the other hands, when the angle is $26^{\circ}$, the center of swirl is always farthest from the cylinder center and only the indistinct swirl is observed even if at the highest lift. Also, all the swirl centers are quite apart from the cylinder center so that the effect of eccentricity may not be negligible at 1.75B regardless the valve angle. Related to the tangential velocity along with the radial direction, the bands of the velocity distribution are very wide and the mean velocities of cylinder center basis are lower than the velocity which is assumed in the ISM evaluation. Lastly, the mean tangential velocity profiles of swirl center basis are sometimes higher than that of ISM-assumed up to 0.6 non-dimensional distance less than 6mm lift, however, as the lift increases the profiles are different according to the angles and profile $11^{\circ}$ is the most closed to the ideal profile. Consequently, the real velocity profile is far from the assumption of ISM evaluation.

A Study on Discontinuous Control Methods For a Hydraulic Position-Control System(II) (유압 위치제어 시스템의 단속적 제어방식에 관한 연구 II)

  • 장효환;안병홍
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.6
    • /
    • pp.1282-1289
    • /
    • 1988
  • It has recently shown that a solenoid valve can be utilized in a hydraulic position-control system by discontinuous control methods. The objective of this study is to investigate the effects of solenoid valves on the response characteristics of a hydraulic position-control system by applying two kinds of discontinuous control methods i.e., Simple On-Off(SOF) and Pulsating On-Off(POF) controls. Three types of solenoid valves i.e., low-frequency, closed-center type(LF/C), low-frequency, tandem-center type(LF/T) were used in this study. Effects of loading conditions and control parameters on the response characteristics were experimentally examined and compared each other. Pressure transients within the actuator were also studied.

Development and Evaluation of Differential Pressure Type Mass Flow Controller for Semiconductor Fabrication Processing (반도체 공정용 차압식 질량 유량 제어 장치의 개발 및 성능 평가)

  • Ahn, Jin-Hong;Kang, Ki-Tai;Ahn, Kang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.3
    • /
    • pp.29-34
    • /
    • 2008
  • This paper describes the fabrication and characterization of a differential pressure type integrated mass-flow controller made of stainless steel for reactive and corrosive gases. The fabricated mass-flow controller is composed of a normally closed valve and differential pressure sensor. A stacked solenoid actuator mounted on a base-block is utilized for precise and rapid control of gas flow. The differential pressure flow sensor consisting of four diaphragms can detect a flow rate by deflection of diaphragm. By a feedback control from the flow sensor to the valve actuator, it is possible to keep the flow rate constant. This device shows a fast response less than 0.3 sec. Also, this device shows accuracy less than 0.1% of full scale. It is confirmed that this device is not attacked by toxic gas, so the integrated mass-flow controller can be applied to advanced semiconductor processes which need fine mass-flow control corrosive gases with fast response.

  • PDF

Design Considerations of Cryogenic Cooling System for High Field Magnets

  • Choi, Yeon-Suk;Kim, Dong-Lak;Lee, Byoung-Seob;Yang, Hyung-Suk;Yoo Jong-Shin;Painter Thomas A.;Miller John R.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.4
    • /
    • pp.30-33
    • /
    • 2006
  • Several crucial issues are discussed in the design of cryogenic cooling system for high field magnets. This study is mainly motivated by our ongoing program to develop a 21 T Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (FT-ICR MS). The magnets of this system will be built horizontally to accomplish the requirement of user friendliness and reliability, and the replenishment of cryogen will not be necessary by a closed-loop cooling concept. The initial cool-down and safety are basically considered in this paper. The effects of the helium II volume and the gap distance of the weight load relief valve (or safety valve) on the cool-down time and temperature rising during an off-normal state are discussed. The total amount of cryogenic cooling loads and the required helium flow rate during cool-down are also estimated by a relevant heat transfer analysis. The temperatures of cryogen-free radiation shield are finally determined from the refrigeration power of a cryocooler and the total cryogenic loads.

An Ultrastructural Study on the Glochidium and Glochidial Encystment on the Host Fish (Glochidium larva 의 구조와 숙주어류에서의 피양형태에 관한 미세구조적 연구)

  • Jeong, Kye-Heon
    • The Korean Journal of Malacology
    • /
    • v.5 no.1
    • /
    • pp.1-9
    • /
    • 1989
  • A scanning electron microscopic study on the glochidium and glchidial encystment of Anodonta grandis on the guppy was conducted. The shape of the glochidium is apparently triangular and its averge size is 0.45mm X0.4mm when closed, The two glochidial shell valves are of the same size, kept together by a ligament of 120${\mu}{\textrm}{m}$ in length and 7 ${\mu}{\textrm}{m}$ in width. Each of the glochidial shell valves has a 16 ${\mu}{\textrm}{m}$ long hook sitdded with many spines on the superior face. A large area to the apex of the valve surrounding the base of the hook is provided with numerous small spines which become progressively smaller towards the periphery of the area, The external surface of the glochidial shell valve is covered with numerous small processes showing successive change in the shape and the pattern of destribution by part. Besides the processes, there are a number of niches scattered all over the exterior surface. The glochidial shell valve has two layers. One is the outer thin membrane bearing the processes and the niches and the others is the inner layer bearing numerous holes which any accessory structure and 2.65 ${\mu}{\textrm}{m}$ in diameter, emerges from a canal located at center of ventral plate of the mamtle, A total of three types of the hair cells are observed. In present artificial infection of the glochidium to the guppy, it took about three to four hours to complete an early cysts, During the period of encystment, The epithelial cells of the host fish actively migrated toward the attached glochidium and covered it.

  • PDF

Aortic and Mitral Valve Replacement with Reconstruction of the Intervalvular Fibrous Skeleton in Prosthetic Valve Endocarditis (인공판막 심내막염에서 판막간 섬유체 재건을 이용한 대동맥판 및 승모판 치환술)

  • Baek, Man-Jong;Kim, Wook-Sung;Oh, Sam-Se;Jeon, Yang-Bin;Ryu, Jae-Wook;Kong, Joon-Hyuk;Lim, Cheong;Kim, Soo-Cheol;Kim, Woong-Han;Na, Chan-Young;Lee, Seong-Ki;Lee, Chang-Ha;Lee, Young-Tak;Yoon, Youg-Woong;Park, Young-Kwang;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.34 no.7
    • /
    • pp.561-565
    • /
    • 2001
  • Patients who have complex endocarditis with involvement of both the aortic and mitral valves and intervalvular fibrous skeleton are among the most difficult to treat and still have the highest surgical mortality and morbidity rates. We report one case of aortic and mitral valve replacement with reconstruction of the fibrous skeleton performed in a 55-year-old female patient who had an aortic annular abscess and both the aortic and mitral prosthetic valve endocarditis with destruction of the fibrous skeleton. Previously, she had undergone redo double valve replacement\`, Transesophageal echocardiogram showed the paravalvular defect at the noncoronary aortic sinus and abnormal sinus tract along the fibrous skeleton. Emergent operation was performed due to positive blood cultures of staphylococcus epidermidis and persistent sepsis despite appropriate antibiotic therapy. After aortotomy extended to the roof of left atrium, both prosthetic valves and destroyed fibrous skeleton were completely resected and the aortic annular abscess was debrided and closed with a bovine pericardial patch. Reconstructions of both aortic and mitral annuli and the fibrous skeleton were done by using two separate bovine pericardial patches in triangular shape and mechanical valves were implanted. Postoperatively, adequate antibiotic therapies were continued and the patient was discharged at the postoperative 72 days without evidence of recurrence of endocarditis. Transthoracic echocardiogram of the postoperative 8 months shows no paravalvular leakage or recurrence of endocarditis and the patient has been followed up with no symptom.

  • PDF