• 제목/요약/키워드: Close loop

검색결과 173건 처리시간 0.028초

LOW-DENSITY CLOSE-CLOSED LOOP BURST ERROR DETECTING CODES

  • Dass, Bal-Kishan;Jain, Sapna
    • Journal of applied mathematics & informatics
    • /
    • 제9권1호
    • /
    • pp.231-238
    • /
    • 2002
  • In this paper, we study cyclic codes detecting a subclass of close-closed loop bursts viz. low-density close-closed loop bursts. A subclass of CT close-closed loop berets called CT low-density close-closed loop bursts is also studied.

보드 설계에 따른 Adaptive Bandwidth PLL의 성능 분석 (Performance Analysis of Adaptive Bandwidth PLL According to Board Design)

  • 손영상;위재경
    • 대한전자공학회논문지SD
    • /
    • 제45권4호
    • /
    • pp.146-153
    • /
    • 2008
  • High speed serial link에 적합한 clock multiphase generator용 integrated phase-locked loop (PLL)을 설계하였다. 설계된 PLL은 programmable current mirror를 사용하여 동작 범위 안에서 동일한 loop bandwidth와 damping factor를 가진다. 또한 설계한 PLL 회로 netlists를 가지고 HSPICE 시뮬레이션을 통해 close-loop transfer function과 VCO의 phase noise transfer function을 구하였다. Board 위 칩의 자체 임피던스는 decoupling capacitor의 크기와 위치에 따라 계산된다. 세부적으로, close-loop transfer function에서 gain의 최대값과 VCO noise transfer function에서 gain의 최대값 사이의 주파수범위에서 decoupling capacitor의 크기와 위치에 따른 보드 위 칩의 자체 임피던스를 구하였다. 이를 바탕으로 보드에서의 decoupling capacitor의 크기와 위치가 PLL의 jitter에 어떠한 영향을 미치는지 분석하였다. 설계된 PLL은 1.8V의 동작 전압에서 400MHz에서 2GH의 wide operation range를 가지며 $0.18-{\mu}m$ EMOS공정으로 설계하였다. Reference clock은 100MHz이며 전체 PLL power consumption은 1.2GHz에서 17.28 mW이다.

멀티미디어단말기용 박막형 위상제어루프 안테나 (Phase Controlled Thin Film Loop Antenna for Multi-media Devices)

  • 신천우
    • 한국멀티미디어학회논문지
    • /
    • 제12권7호
    • /
    • pp.971-978
    • /
    • 2009
  • 본 연구는 위상제어형 루프안테나에 관한 것으로서, 유전체기판 상에 에칭기법이나 프린트기법으로 루프안테나용 동박패턴을 제작함에 있어, 루프에서 발생하는 전자계가 서로 보완위상이 되게 배치하여, 인접하는 루프패턴 간에서 방사되는 전자계가 서로 충돌하지 않게 방사되는 위상제어형 루프코일 배치에 관한 것이다. 이 방법으로 인접하는 각 루프코일이 서로 보완위상으로 배치되어 전자계가 원만하게 방사되어, 방사 손실이 없고 방사 효율이 뛰어나게 된다. 또한 복수 개의 각 루프코일의 길이를 서로 달리함으로 인해, 각 루프코일의 길이가 달라짐에 따라 공진주파수가 달라지고, 이러한 공진점이 다른 루프코일을 밀결합 시킴으로 인해 공진주파수 대역을 넓게 할 수 있고, 원하는 대역만큼 조절할 수가 있게 된다. 이로 인하여 크기 20mm$\times$20mm 이하의 사이즈에, 두께 0.4mm 이하의 박막의 유전체기판에 CDMA850 휴대폰대역 및 PCS, WCDMA 등의 안테나를 구현하여 게인 0dBi 이상 방사효율 60% 이상의 안테나를 구현할 수가 있다.

  • PDF

Loop closure-based high-resolution façade digital modeling technique of large-scale dams using UAV

  • Myung Soo Kang;Keunyoung Jang;Yong-Rae Yu;Yun-Kyu An
    • Smart Structures and Systems
    • /
    • 제33권5호
    • /
    • pp.349-358
    • /
    • 2024
  • Structural digital models can be effectively established by spatially obtaining digital images using an unmanned aerial vehicle (UAV). One of the main purposes of the structural digital modeling is computer vision-based exterior damage detection of a target structure. To investigate micro-scale damage from the digital model, high-resolution digital images obtained with a close-up vision survey is typically required. However, serial image synthesis such as image stitching may cumulate stitching errors as the number of scanned images increases. Therefore, in this paper, a novel loop closure-based digital image stitching technique is proposed and experimentally validated using the close-up surveyed digital images acquired from an in-situ dam structure located in South Korea. The test results reveal that the proposed technique outperforms a non-loop closure-based image stitching technique, which can cause serious distortions, such as ghosting and vanishing phenomena.

사출성형기의 속도제어 방식에 따른 형개거리에 관한 연구 (A study on the mold opening stroke according to the control method of the injection molding machine)

  • 정현석;이춘규
    • Design & Manufacturing
    • /
    • 제15권3호
    • /
    • pp.56-61
    • /
    • 2021
  • The increase in automation facilities in the injection molding industry is a very important process control item. The most important item when constructing an unmanned machine using a take-out robot is the "mold opening stroke" of the mold. The injection molding machine control method is divided into hydraulic type and electric type, and there have been few studies on the mold opening distance according to the control method. In this study, the correlation was confirmed by increasing the injection speed to 20, 50, 80, and 100% for the three types of hydraulic control method, open loop and close loop, and electric control method. Through the experiment, the following results were obtained. (1) It can be seen that the reproducibility is excellent with the electric, close loop, and open loop control methods. (2) When the injection speed is set to 50%, the mold opening distance is 263.10~263.27 mm, which is the most reproducible. (3) As a result of ANOVA, both injection speed and mold opening distance showed a significant difference in the hydraulic control method (p<0.05), but it was verified through experiments that there was no significant difference in the electric control method. Based on these results, when electric control is selected rather than hydraulic control, the reproducibility of the mold opening distance is excellent, so it is thought that the taking-out robot can take the object out of the mold more safely.

Project Summary of Three Gorges' 840MVA Hydro-generator with Close-Loop-Self-Circulating Evaporative Cooling System

  • Yuan, Jiayi;Meng, Dawei;Gu, Guobiao;Song, Fuchuan;Zhang, Tianpeng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.48-53
    • /
    • 2014
  • In December 2011 and July 2012, two sets of 840MVA hydro-generator of Three Gorges on Yangtze River with Close-loop-self-circulating evaporative cooling (CLSCEC) system were put into commercial operation. In this paper, we make engineering summary of these two generators with CLSCEC system. We also make a comparison between the internal water cooling (IWC) hydro-generator and the CLSCEC hydro-generator used in Three Gorges power plant in fields of their operating characteristics, working performances, technical features, working safety and reliability. In addition, engineering structures, type tests' results and systematic emulating calculation of CLSCEC schemes are analyzed.

The Mold Close and Open Control of Injection Molding Machine Using Fuzzy Algorithm

  • Park, Jin-Hyun;Lee, Young-Kwan;Kim, Hun-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.575-579
    • /
    • 2005
  • In this paper, the development of an IMM(Injection Molding Machine) controller is discussed. Presently, the Mold Close and Open Control Method of a toggle-type IMM is open-loop control. Through the development, a PC based control system was built instead of an existing controller and a closed-loop control replaced the previous control method by using PC based PLC. To control the nonlinear system of toggle type clamping unit, a fuzzy PI control algorithm was selected and it was programmed by an IL(Instruction List) and a LD(Ladder Diagram) on a PC based PLC. The application of fuzzy algorithm as the control method was also considered to change a control object like a mold replacement or an additional apparatus. For the development of an IMM controller, PC based PLC of PCI card type, distributed I/O modules with CANopen and Industrial PC and HMI (Human Machine Interface) software were used.

  • PDF

HARDWARE IN THE LOOP SIMULATION OF HYBRID VEHICLE FOR OPTIMAL ENGINE OPERATION BY CVT RATIO CONTROL

  • Yeo, H.;Song, C.H.;Kim, C.S.;Kim, H.S.
    • International Journal of Automotive Technology
    • /
    • 제5권3호
    • /
    • pp.201-208
    • /
    • 2004
  • Response characteristics of the CVT system for a parallel hybrid electric vehicle (HEV) are investigated. From the experiment, CVT ratio control algorithm for the optimal engine operation is obtained. To investigate the effect of the CVT system dynamic characteristics on the HEV performance, a hardware in the loop simulation (HILS) is performed. In the HILS, hardwares of the CVT belt-pulley and hydraulic control valves are used. It is found that the engine performance by the open loop CVT ratio control shows some deviation from the OOL in spite of the RCVs open loop control ability. To improve the engine performance, a closed loop control of the CVT ratio is proposed with variable control gains depending on the shift direction and the CVT speed ratio range by considering the nonlinear characteristics of the RCV and CVT belt-pulley dynamics. The HILS results show that the engine performance is improved by the closed loop control showing the operation trajectory close to the OOL.

다중수원을 활용한 멀티워터 루프시스템의 표준화방안 구축에 관한 연구 (A Study on Standardization Method Establishment of Multi Water-Loop System using Multi Water Resources)

  • 이현동;이준형;곽필재
    • 한국관개배수논문집
    • /
    • 제21권1호
    • /
    • pp.109-117
    • /
    • 2014
  • Multi water-loop system is the efficient customer centered facilities of water supply by utilizing the multi water resources. Multi water-loop system is divided into various types. The system is classified potable and non-potable type. Mostly, the potable type utilizes surface water and ground water. However, the non-potable type utilize the multi water resources, such as rain water, sea water, reclaimed water, etc. Selective intake is possible when characteristics of region, physiographic condition and purpose of use are considered. For instance, downtown type, new-city type, agriculture type, island type are available. For development and application of these multi water-loop system, standardization is needed. For standardization, several methods are given; design principles, selection and composition method of multi water-loop system structure, BIM/GIS application method, safety inspection method. Consequently, a road map of design standardization method can be established. In this road map, there are three parts for the standardization of multi water-loop system. Three parts are the considerations, base material and ways of standardization. Design standardization become close when this road map followed by someone who plan the multi water-loop system. In this way, loop system's development is more efficient and economic. In hereafter research, each type's characteristic will be analysed and standardization methods can be established.

  • PDF