• Title/Summary/Keyword: Close Force

Search Result 433, Processing Time 0.026 seconds

Characterization and modeling of a self-sensing MR damper under harmonic loading

  • Chen, Z.H.;Ni, Y.Q.;Or, S.W.
    • Smart Structures and Systems
    • /
    • v.15 no.4
    • /
    • pp.1103-1120
    • /
    • 2015
  • A self-sensing magnetorheological (MR) damper with embedded piezoelectric force sensor has recently been devised to facilitate real-time close-looped control of structural vibration in a simple and reliable manner. The development and characterization of the self-sensing MR damper are presented based on experimental work, which demonstrates its reliable force sensing and controllable damping capabilities. With the use of experimental data acquired under harmonic loading, a nonparametric dynamic model is formulated to portray the nonlinear behaviors of the self-sensing MR damper based on NARX modeling and neural network techniques. The Bayesian regularization is adopted in the network training procedure to eschew overfitting problem and enhance generalization. Verification results indicate that the developed NARX network model accurately describes the forward dynamics of the self-sensing MR damper and has superior prediction performance and generalization capability over a Bouc-Wen parametric model.

Finding an initial solution and modifying search direction by the centering force in the primal-dual interior point method (원쌍대 내부점기법에서 초기해 선정과 중심화 힘을 이용한 개선 방향의 수정)

  • 성명기;박순달
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.530-533
    • /
    • 1996
  • This paper deals with finding an initial solution and modifying search direction by the centrering force in the predictor-corrector method which is a variant of the primal-dual barrier method. These methods were tested with NETLIB problems. Initial solutions which are located close to the center of the feasible set lower the number of iterations, as they enlarge the step length. Three heuristic methods to find such initial solution are suggested. The new methods reduce the average number of iterations by 52% to at most, compared with the old method assigning 1 to initial valurs. Solutions can move closer to the central path fast by enlarging the centering force in early steps. It enlarge the step length, so reduces the number of iterations. The more effective this method is the closer the initial solution is to the boundary of the feasible set.

  • PDF

Measurement and Design Review of Contact Force by Garter Spring in Connection between Circuit Breaker and Bus Bar (차단기와 모선과의 연결시 가터스프링에 의한 접촉력의 측정 및 설계 고찰)

  • 조상순;안길영;박우진;오일성
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.942-945
    • /
    • 2002
  • A garter spring, which is a long. special, close-coiled extension spring with its ends joined to form a ring, is used in connection between vacuum circuit breaker and bus bar in switchgear. To carry short-time current and resist welding at the contact surface in the connection, the garter spring must transmits an uniform contact force to the contact surface through the contact chips arranged in the circumference of bus bar. In this paper, the system for measurement of the contact force by the garter spring is developed. Using the developed measurement system, the design of the connection structure including the garter spring is reviewed to obtain the uniform contact forces in all of contact chips.

  • PDF

Performance Study of Magnetic Bearing Considering the Performance Limit (자기 베어링의 성능한계를 고려한 작동특성 연구)

  • 장인배;한동철
    • Journal of KSNVE
    • /
    • v.5 no.1
    • /
    • pp.59-65
    • /
    • 1995
  • In this study, we investigated the operational limit of magnetic bearing-rotor system due to the maximum force limit and slew rjate limit of the electromagnetic actuator as a function of the time dependent control characteristics. The feedback gain of the controller varies the current of the electromagnet coil with the motion of the rotor. The distorsion of magnetic force due to the slew rate limit is not occurred jup to 30, 000 rpm in the magnetic bearing that we have a close relation with the rotational speed and vibration level of the rotor and the proportional gain of the controller. Therefore the maximum force limit determines the maximum allowable orbit radius of the magnetic bearing-rotor system. The maximum allowable vibration levels are exponentially decreased according to the increment of rotational speed and proportional gain of the controller.

  • PDF

Rocking Behavior of Steel Damper Shape (강재댐퍼 형상에 따른 록킹거동)

  • Lee, Hyun-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.45-52
    • /
    • 2020
  • In this study, performance experiments were performed on the shape of steel dampers that affect the rocking behavior. Three types of strut shapes of SI type, SV type and SS type were considered as experimental variables. As a result of the experiment, the capacity to resist the moment and drift ratio according to the strut shape of the steel damper was evaluated as very close. Finally, it was evaluated that the SV type steel damper has stable deformation and energy dissipation capability. As a result of the evaluation of the proposed damper transmission force, it is considered that the damper transmission force is evaluated larger than the applied horizontal force, and it is necessary to supplement it.

Contact Force and Response Analysis of Vibration Isolated Systems (진동절연 시스템의 충격력과 충격응답 해석)

  • 김준호;박윤식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3185-3194
    • /
    • 1994
  • In this study, an impact model and impact response analysis method was suggested for the impacts between arbitrary shaped bodies. Unlike the impacts between geometrically simple structures, there is no rules to analyze the impacts between general elastic structures First of all, it has been attempted to explain the impoot between arbitrary elastic structures as the elastic deformation of a virtual contact spring in the vicinity of contact points. The contact stiffness and the exponent are determined from the Hertz's contact theory and F. E. analysis. In order to evaluate the validities and limitations of the proposed methods, an impact tester and the miniature of container, missile and isolators have been provided and tested experimentally. All the experiments were performed with various impact conditions. The results obtained by the proposed methods were directly compared with the measured values in terms of maximum contract force, contact duration, the shape of contact force and the structure responses. The computed contact force and responses, using this proposed methods, were very close to the measured results, unless any plastic deformations were presented.

Influence of the axial force on the behavior of endplate moment connections

  • Ghassemieh, Mehdi;Shamim, Iman;Gholampour, Ali Akbar
    • Structural Engineering and Mechanics
    • /
    • v.49 no.1
    • /
    • pp.23-40
    • /
    • 2014
  • In this article, using finite element method of analysis (FEM), behavior of the endplate moment connection subjected to axial force and bending moment is investigated. In the FEM model, all the nonlinear characteristics such as material, geometry, as well as contact have been included. First, in order to verify the numerical model of the connection, an analysis of the endplate moment connection conducted without the application of the axial force. Results obtained from FEM indicating a close and good correlation with the experimental results. Then to investigate the influence of the axial forces, the connections subjected to axial forces as well as the bending moment are analyzed. To observe the overall effect of these actions, the momentaxial force interaction diagrams are drawn. It is observed that the presence of axial force even in a small value can change the behavior of the connection significantly. It is also shown that the axial forces can alter the failure mode of the connection; and therefore it could result in a different than the predicted moment capacity of the connection.

Analysis of hysteresis rule of energy-saving block and invisible multi-ribbed frame composite wall

  • Lin, Qiang;Li, Sheng-cai;Zhu, Yongfu
    • Structural Engineering and Mechanics
    • /
    • v.77 no.2
    • /
    • pp.261-272
    • /
    • 2021
  • The energy-saving block and invisible multi-ribbed frame composite wall (EBIMFCW) is a new type of load-bearing wall. The study of this paper focus on it is hysteresis rule under horizontal cyclic loading. Firstly, based on the experimental data of the twelve specimens under horizontal cyclic loading, the influence of two important parameters of axial compression ratio and shear-span ratio on the restoring force model was analyzed. Secondly, a tetra-linear restoring force model considering four feature points and the degradation law of unloading stiffness was established by combining theoretical analysis and regression analysis of experimental data, and the theoretical formula of the peak load of the EBIMFCW was derived. Finally, the hysteretic path of the restoring force model was determined by analyzing the hysteresis characteristics of the typical hysteresis loop. The results show that the curves calculated by the tetra-linear restoring force model in this paper agree well with the experimental curves, especially the calculated values of the peak load of the wall are very close to the experimental values, which can provide a reference for the elastic-plastic analysis of the EBIMFCW.

Wind tunnel investigation of correlation and coherence of wind loading on generic tall twin buildings in close proximity

  • Lim, Juntack;Bienkiewicz, Bogusz
    • Wind and Structures
    • /
    • v.18 no.4
    • /
    • pp.443-456
    • /
    • 2014
  • A popular modern architectural form for tall buildings is two (or more) towers which are structurally linked through such features as a shared podium or sky-bridges. The fundamental features of the wind loading and the structural links of such buildings can be studied by measuring load components on the individual unlinked towers along with their correlations. This paper describes application of dual high frequency force balance (DHFFB) in a wind tunnel study of the base wind loading exerted on generic tall twin buildings in close proximity. Light models of two identical generic tall buildings of square plan were mounted on DHFFB and the base wind loading exerted on the buildings was simultaneously acquired. The effects of the relative positions of the buildings on the correlations and coherences involving loading components on each building and on the two buildings were investigated. For some relative positions, the effects of the building proximity on the wind loading were significant and the loading was markedly different from that exerted on single buildings. In addition, the correlations between the loadings on the two buildings were high. These effects have potential to significantly impact, for example, the modally-coupled resonant responses of the buildings to the aerodynamic excitations. The presented results were not meant to be recommended for direct application in wind resistant design of tall twin buildings. They were intended to show that wind loading on tall buildings in close proximity is significantly different from that on single buildings and that it can be conveniently mapped using DHFFB.

A Study on the Thrust Force of a Narrowly Spaced Disk Valve (좁은 틈새 원판 밸브의 추력에 관한 연구)

  • Jeong, Hyo-Min;Kim, Si-Young
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.1
    • /
    • pp.30-38
    • /
    • 1987
  • One of the important characteristics of a disk valve is the thrust force. This thrust force has close relationship to the clearance between valve and valve seat in the disk valve. When the clearance is very small, it is very important to analyze the thrust force. This paper deals with the variation of the thrust force by comparing the experimental ed results and theoretical results in accordance with d the valve clearance. In case of the theoretical problems, the pressure gradient of the radial flow in a narrowly spaced disks was calculated by Sui Lin and Pai-Mow Lee already. Therefore, the thrust force of the disk valve was computed by utilizing this pressure gradient in the radial flow. In the experiment, the hydraulic oil which has high viscosity was used. Making the comparative study of the calculated results and the experimental results, the characteristics of the thrust force in the disk valve were investigated. The results obtained are as follows: 1. When the disk valve clearance was comparatively small, the experimental values had fairly good agreement with the calculated values independently of inlet pressure and valve size. 2. When the disk valve size was constant in the wide range of the disk valve clearance, the lower the inlet pressure was, the better the agreement between the experimental values and the calculated values was. 3. In case of the small clearance, the thrust force was depended on the outer diameter of the disk valve. In opposite case the thrust force was constant as the disk valve size varied.

  • PDF