• Title/Summary/Keyword: Clinical work-flow

Search Result 32, Processing Time 0.023 seconds

Design of Optimized Ultrasound Clinical Work-Flow; Usability Perspective

  • Bag, ByungEun;Yoo, SunKook;Jang, WonSeuk
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.40-42
    • /
    • 2015
  • Purpose Usability is an important factor in our life. This paper presents an approach to design the clinical work-flow for ultrasound system. And, we tried to apply this work-flow in diagnosis ultrasound system. Materials and Methods For user learnability, we follow international standard IEC 60601-1-1 and IEC 62366 which describes usability of medical instrument. User requirement are applied by 10 clinicians who are well aware of usability. We considered user environment and designed clinical work-flow into two types: general use and emergency use. The designed clinical work-flow was evaluated by 10 clinicians and results derived from the evaluation were analyzed. Results We could successfully design optimized clinical workflow of ultrasound system. Conclusion This paper suggests usability testing for optimized ultrasound clinical workflow. Using this clinical work flow, users can enhance their clinical performance and reduce operation time.

Job Analysis for Role Identification of Clinical Nurses with Expanded Role - Clinical Nurse with Education and Clinical Nurse with Coordination - (진료협력간호사의 역할규명을 위한 직무분석 - 교육상담간호사와 진료코디네이터간호사 중심 -)

  • Sung, Young Hee;Lim, Nan Young;Park, Kwang Ok;Jung, Jung Hee;Kwon, In Gak;Kim, Ul Soon;Hwang, Moon Sook
    • Journal of Korean Clinical Nursing Research
    • /
    • v.15 no.2
    • /
    • pp.139-155
    • /
    • 2009
  • Purpose: The purpose of this study was to identify role through job analysis (duties and tasks) of nurses who work as clinical nurses with education and clinical nurse with patient coordination within the hospital. Methods: The DACUM committee was organized with 8 nurses each, clinical nurses with education and clinical nurses with coordination. The committee derived the duties and tasks of the two groups of clinical nurses from their actual work in the hospital through a DACUM workshop. Validity of the derived duties and tasks was tested by 12 nurses at each of 3 hospital. Results: For clinical nurse with education, 8 duties and 45 tasks were identified, which included patient education and consultation, patient advocacy, management of the therapeutic process, direct nursing care, activities work directed at improvement, management of health promotion events, administration work, and self-improvement. For clinical nurse with coordination, 10 duties and 54 tasks were identified, and included client consultation, client education, direct nursing care, coordination of therapeutic flow, employee education, public relations with the community, planning and operation of meetings, administration work, work directed at improvement, and self-improvement. Conclusion: The results of this study contribute to not only the work of the participants but also basic data for human resource management in the hospital.

Clinical Application of OXYREX Hollow Fiber Membrane Oxygenator (국산 막형 산화기 (OXYREX)의 체외순환 임상 성적 - 개심수술 40례 적용 -)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1049-1056
    • /
    • 1990
  • The OXYREX hollow fiber membrane oxygenator developed by joint work of KIST and Green Cross Medical company has been evaluated by experimental investigation and clinical application, In this oxygenator gas exchanges occur through small pores of 0.1pm size which are distributed on 70% of surface of polypropylene hollow fiber. The Oxyrex membrane oxygenator consists of 36 thousand hollow fibers and it has 3.3m2 of gas exchange surface. The Oxyrex membrane oxygenator has unique blood flow path: blood enters the oxygenator passes between the hollow fibers and exits through outlet ports, that provides low transmembrane pressure drop. In the animal experiment and in vitro investigations of Oxyrex oxygenator, it showed low transmembrane pressure difference, effective heat exchanger performance, stable gas transfer function and less blood trauma. The Oxyrex oxygenator been used from March, 1990, to October, 1990, in 40 patients undergoing open heart operations. In the clinical applications of Oxyrex, adequate oxygenation[PaO2, 283$\pm$70mmHg] and carbon dioxide removal[PaCO2, 27\ulcorner6mmHg]were maintained under the condition of FiO2: below 0.6, Hct; 25%, perfusion flow; 2.4 L/min, gas flow: 2.1 L/min. During maximum 365 minutes of cardiopulmonary bypass[CPB] time period, the Oxyrex oxygenator maintained stable condition of PaO2, PaCO2 respectively and it also kept low plasma hemoglobin level. The complement proteins C3 and CH50 were not significantly changed pre to post CPB. There were no complications related to the oxygenator during and after the CPB.

  • PDF

Development of Non-Invasive Pressure Estimation Using 3D Multi-Path Line Integration Method from Magnetic Resonance Velocimetry (MRV) (자기공명유속계 (MRV) 에서 3차원 다중경로 선적분법을 활용한 비침습적 압력예측 방법 개발)

  • Ilhoon Jang;Muhammad Hafidz Ariffudin;Simon Song
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.2
    • /
    • pp.14-23
    • /
    • 2023
  • The pressure difference across stenotic blood vessels is a commonly used clinical metric for diagnosing many cardiovascular diseases. At present, most clinical pressure measurements rely solely on invasive catheterization. In this study, we propose a novel method for non-invasive pressure estimation using the incompressible Navier-Stokes equations and a 3D multi-path integration approach. We verify spatio-temporal convergence on an in-silico dataset of a cylindrical straight pipe phantom with steady and pulsatile flow fields. We then evaluate the proposed method on an in vitro dataset of reconstructed control, pre-operative, and post-operative carotid artery cases acquired from 4D flow MRI. The performance of our method is compared to existing approaches based on the pressure Poisson equation and work-energy relative pressure. The results demonstrate the proposed method's high accuracy, robustness to spatio-temporal subsampling, and reduced sensitivity to noise, highlighting its great potential for non-invasive pressure estimation.

Professional Certification of Medical Technologists in Korea, Japan, and United States of America (한국, 일본, 미국 임상병리사 전문자격)

  • Koo, Bon-Kyeong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.1
    • /
    • pp.1-14
    • /
    • 2019
  • The names of medical technologist in Korea, Japan, and the United State of America vary depending on the medical system, educational system, and work areas. Conventionally, jobs equal or similar to medical technologist (commonly known as clinical laboratory technologist, medical laboratory technologist, clinical laboratory scientist, and medical laboratory scientist), histotechnologist, cytotechnologist, and genetic technologist. Jobs, such as extracorporeal technologist, medical electrophysiology technologist, and medical sonographer, allow other allied health professionals including medical technologists, to obtain their qualification. The work areas of medical technologists are classified into clinical pathologic technology, pathologic technology, clinical genetics technology, nuclear medicine in vitro technology, and clinical physiologic technology. New titles of Korean specialized medical technologists refer to certification systems, such as CLMJ, CMAJ, ASCP, IAC, ABRET, and ARMDS. Currently, there are eight types of specialized medical technologists under the cooperation of specialized academic societies. They are hematology, transfusionology, chemistry, immunology, microbiology, histology, cytology, nuclear medicine. It can be further divided into 20 categories according to the work areas such as mass spectrometry, infection control, Pathologists' Assistant, flow cytometry, HLA, cytogenetics, molecular genetics, cardiopulmonary physiology, neurophysiology (EEG/EMG/PSG/etc.), cardiac sonography, neurosonography (TCD/carotid), and medical device quality manager.

Designing a Molecular Diagnostic Laboratory for Testing Highly Pathogenic Viruses (고병원성 바이러스 검사를 위한 분자진단검사실 구축)

  • Jung, Tae Won;Jung, Jaeyoung;Kim, Sunghyun;Kim, Young-Kwon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.2
    • /
    • pp.143-150
    • /
    • 2021
  • The recent spread of novel and highly variant pathogenic viruses, including the coronavirus (SARS-CoV-2), has increased the demand for diagnostic testing for rapid confirmation. This has resulted in investigating the functional capability of each space, and preparing facility guidelines to secure the safety of medical technologists. During viral evaluations, there is a requirement of negative pressure facilities along with thread separation, during pre-treatment of samples and before nucleic acid amplification. Space composition therefore needs to be planned by considering unidirectional air flow. This classification of safety management facilities is designated as biosafety level 2, and personal protective equipment is placed accordingly. In case of handling dangerous materials, they need to be carried out of the biosafety cabinet, and sterilizers are required for suitable disposal of infectious agents. A common feature of domestic laboratories is maintenance of the sample pre-treatment space at a negative pressure of -2.5 Pa or less, and arranging separate pre-treatment and reagent preparation spaces during the test process. We believe that the data generated in this study is meaningful, and offers an efficient direction and detailed flow for separation of the inspection process and space functions. Moreover, this study introduces construction of the laboratory by applying the safety management standards.

Information Engineering and Workflow Design in a Clinical Decision Support System for Colorectal Cancer Screening in Iran

  • Maserat, Elham;Farajollah, Seiede Sedigheh Seied;Safdari, Reza;Ghazisaeedi, Marjan;Aghdaei, Hamid Asadzadeh;Zali, Mohammad Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6605-6608
    • /
    • 2015
  • Background: Colorectal cancer is a major cause of morbidity and mortality throughout the world. Colorectal cancer screening is an optimal way for reducing of morbidity and mortality and a clinical decision support system (CDSS) plays an important role in predicting success of screening processes. DSS is a computer-based information system that improves the delivery of preventive care services. The aim of this article was to detail engineering of information requirements and work flow design of CDSS for a colorectal cancer screening program. Materials and Methods: In the first stage a screening minimum data set was determined. Developed and developing countries were analyzed for identifying this data set. Then information deficiencies and gaps were determined by check list. The second stage was a qualitative survey with a semi-structured interview as the study tool. A total of 15 users and stakeholders' perspectives about workflow of CDSS were studied. Finally workflow of DSS of control program was designed by standard clinical practice guidelines and perspectives. Results: Screening minimum data set of national colorectal cancer screening program was defined in five sections, including colonoscopy data set, surgery, pathology, genetics and pedigree data set. Deficiencies and information gaps were analyzed. Then we designed a work process standard of screening. Finally workflow of DSS and entry stage were determined. Conclusions: A CDSS facilitates complex decision making for screening and has key roles in designing optimal interactions between colonoscopy, pathology and laboratory departments. Also workflow analysis is useful to identify data reconciliation strategies to address documentation gaps. Following recommendations of CDSS should improve quality of colorectal cancer screening.

Safety Evaluation of LB10522, a New Cephalosporin Antibiotic

  • Kim, Seong-Il;Raffi Mikaelian;Kwak, Jin-Hwan;Kim, In-Chull;Lee, Chang-Ho
    • Biomolecules & Therapeutics
    • /
    • v.3 no.4
    • /
    • pp.316-321
    • /
    • 1995
  • All the pharmacological studies of LB17522 described here were carried out with high doses (fifteen to sixty times of the therapeutic dose) to determine an indication of potential side effects in clinical use in terms of the acute clinical signs, cardiovascular and central nervous system. LB10522 does not produce any observable clinical signs except for the symptoms such as moist eye, skin rash, slight salivation, vomitting, and slightly reduced activity. The effects of LB10522 on the hemodynamics and cardiac function of anesthetized beagle dogs are as follows; heart rates and mean arterial blood pressure had a tendency to increase mildly, which is a normal finding in anesthetized dogs. All the animals except for one showed relatively stable respiratory rates throughout the observation period. Each animal treated with LB10522 showed slight increase in the left cardiac work and left ventricular stroke work which are mainly related to corresponding increases in cardiac output. Femoral blood flow were shown to be increased in some animals treated with LB10522. The epileptogenic activities of various cephalosporins were assessed by a direct intracerebral injection of appropriate concentration of test articles. The CD$_{50}$ values (nmol) obtained from the analysis of the dose-response data are as follows; 78.2, 175.3, 156.3, and 53.5 for cefazolin, cephaloridine, ceftazidime, and LB 10522, respectively. LB10522 seems to be equipotent with cefazolin or to be three times more potent than cephaloridine and ceftazidime in causing adverse CNS stimulation. Taken into consideration all the information obtained, LB10522 is not supposed to induce much changes in the functions examined in these studies in man at therapeutic doses.s.

  • PDF

Clinical Decision Support System for Identification of Anaerobe (혐기성 동정을 위한 임상의사결정 지원시스템 개발)

  • Shin Yong-Won
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.6
    • /
    • pp.20-30
    • /
    • 2005
  • In the anaerobe identification, when we develop the clinical decision support system for department of laboratory medicine, we must consider expression of an incomplete knowledge structure and addition of an evolving knowledge based on an expert's informal and heuristic knowledge is very complicated work flow. In the present study, we developed the system for anaerobe identification to advise on identification of unknown bacillus using knowledge base and inference engine. In the future, we are planning to develop the clinical decision support system for the whole bacteria not only an anaerobe but also aerobe to offer an expert's static and dynamic knowledge.

  • PDF

Microbiological Hazard Evaluation of the Product Flow of Korean Rice Cakes (떡류 제조 시 미생물학적 위해도 평가에 관한 연구)

  • Jang, Myung-Sook;Lee, Hyo-Soon
    • Korean journal of food and cookery science
    • /
    • v.22 no.6 s.96
    • /
    • pp.747-755
    • /
    • 2006
  • This study evaluated the microbiological hazard of three Korean rice cake products (Gaepidduk, Injulmi, Julpyon). Microorganisms testing was conducted in various phases of the product flow of Korean rice cakes preparation, food equipment, environment work and cook employees at small scale. The results showed the presence of redbean paste, soybean powder and oil at levels as high as $10^5$ CFU/g on the hazard analysis of rice cakes ingredients. High levels of coliforms were detected in Julpyon products after 24 hr. and on the cooker's aprons. Clinical bacteria were not detected in any of the rice cakes. We concluded that there is a strong requirement for education related to personal hygiene for the production of hygienic rice cake products and for the publics health.