• Title/Summary/Keyword: Clinical value

Search Result 3,111, Processing Time 0.029 seconds

The Correction Effect of Motion Artifacts in PET/CT Image using System (PET/CT 검사 시 움직임 보정 기법의 유용성 평가)

  • Yeong-Hak Jo;Se-Jong Yoo;Seok-Hwan Bae;Jong-Ryul Seon;Seong-Ho Kim;Won-Jeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2024
  • In this study, an AI-based algorithm was developed to prevent image quality deterioration and reading errors due to patient movement in PET/CT examinations that use radioisotopes in medical institutions to test cancer and other diseases. Using the Mothion Free software developed using, we checked the degree of correction of movement due to breathing, evaluated its usefulness, and conducted a study for clinical application. The experimental method was to use an RPM Phantom to inject the radioisotope 18F-FDG into a vacuum vial and a sphere of a NEMA IEC body Phantom of different sizes, and to produce images by directing the movement of the radioisotope into a moving lesion during respiration. The vacuum vial had different degrees of movement at different positions, and the spheres of the NEMA IEC body Phantom of different sizes produced different sizes of lesions. Through the acquired images, the lesion volume, maximum SUV, and average SUV were each measured to quantitatively evaluate the degree of motion correction by Motion Free. The average SUV of vacuum vial A, with a large degree of movement, was reduced by 23.36 %, and the error rate of vacuum vial B, with a small degree of movement, was reduced by 29.3 %. The average SUV error rate at the sphere 37mm and 22mm of the NEMA IEC body Phantom was reduced by 29.3 % and 26.51 %, respectively. The average error rate of the four measurements from which the error rate was calculated decreased by 30.03 %, indicating a more accurate average SUV value. In this study, only two-dimensional movements could be produced, so in order to obtain more accurate data, a Phantom that can embody the actual breathing movement of the human body was used, and if the diversity of the range of movement was configured, a more accurate evaluation of usability could be made.

A Study of Psychometric Function Curve for Korean Standard Monosyllabic Word Lists for Preschoolers (KS-MWL-P) (한국표준 학령전기용 단음절어표 (Korean Standard Monosyllabic Word Lists for Preschoolers, KS-MWL-P)의 심리음향기능곡선 연구)

  • Shin, Hyun-Wook;Kim, Jin-Sook
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.534-541
    • /
    • 2009
  • Word recognition test (WRT) for the children can be useful for diagnosing the degree of communication disability, prescribing hearing instruments, planning aural rehabilitation and speech therapy, and determination of site of lesions. The Korean standard monosyllabic word lists for preschoolers (KS-MWL-P) were developed considering the criteria given by the literatures. However, the authors of KS-MWL-P suggested more children should be included to verify homogeneity of the lists using psychometric function curve since only 8 children participated in the developing process. The purpose of this study was to explore the homogeneity of KS-MWL-P for supplementing the limitations of the lists employing psychometric analysis. To 23 preschoolers who have normal-hearing, 100 monosyllabic KS-MWL-P words were examined with the pictures. Psychometric function curve with linear slopes of 20% and 80%'s correct rates through accounting recognition scores of each monosyllabic word at variable intensities from -10 to 40 dBHL was obtained and analyzed. As a result, s-shaped psychometric function curve was presented with increasing correct rate depending on intensity and showed no statistical significant differences among each word and list. The congruous graph shapes among lists also indicated good homogeneity and the list 1,2,3,4's average slopes were 4.48, 3.86, 4.65, 4.50. It was verified that the homogeneity was suitable because the analysis of variance showed no statistical significance among lists (p>0.05). However, KS-MWL-P's order of slope according to the order of the number of items, $1{\sim}10$, $1{\sim}20$, $1{\sim}25$ showed no difference with the p-value of 0.93, 0.59, 0.91, 0.70 for the lists 1,2,3, and 4, respectively. Although KS-MWL-P was assumed that the lower-numbered items were easy for testing younger ages, this study's results could not agree with the author's conclusion. Considering this matter, rearranging of the number of items should be performed according to the analysis of slope suggested by this study for testing younger children with easier items. Other than this, in conclusion, KS-MWL-P was proved to be useful for clinical and rehabilitative evaluating and training tools for preschoolers.

Development of a Tool to Measure Knowledge of Clinical Dental Hygienists on Precautions for Dental Treatment of Dementia Patients (임상 치과위생사의 치매 환자 치과 진료 시 주의 사항에 관한 지식측정 도구 개발)

  • Nahyun Kim;So-Jung Mun;Hie-Jin Noh;Sun-Young Han
    • Journal of Korean Dental Hygiene Science
    • /
    • v.6 no.2
    • /
    • pp.79-89
    • /
    • 2023
  • Background and Objectives: The prevalence of dementia is steadily increasing each year, and preceding studies continue to explore the association between dementia and oral health. Dental hygienists require specialized competencies to provide appropriate dental healthcare services, necessitating the development of a tool for the objective measurement of their knowledge levels. This study aimed to develop a knowledge assessment tool for dental hygienists concerning considerations for dental care for patients with dementia. Methods: The study constructed preliminary items based on a literature review and then conducted expert validation, a pilot survey, and the main survey. The main survey was conducted among 220 dental hygienists. Validity and reliability analyses were conducted with the collected data to select the final items, and the correctness rates for each selected item were verified. Results: As a result of the analysis of the collected data, 18 items were eliminated out of a total of 40 preliminary items, leaving a total of 6 factors and 22 items. The Cronbach's α value for the selected items was 0.791. The six factors are as follows: 'Considerations during dental treatment for dementia patients' (5 items), 'medication side effects in dementia patients' (4 items), 'oral care methods for dementia patients' (4 items), 'communication with dementia patients' (4 items), 'psychological reactions of dementia patients' (3 items), and 'guidance for dementia patients' (2 items). The item with the highest correctness rate was item 2 of the 'guidance for dementia patients' category at 98.6%, while the item with the lowest correctness rate was item 2 of the 'psychological reactions of dementia patients' category at 5.9%. Conclusion: This study validated the reliability and validity of the knowledge assessment tool, which lays the foundation for future research on dental hygienists and dementia. It contributes essential data for ongoing education, development of educational programs, and establishing operational guidelines in healthcare institutions.

A Study of the New Positioning Guide Based on the Correlation between the Orbit Meatus Line and Mandibular Body Angle in Paranasal Sinus Parietoacanthial Projection(Water's Method) (코곁굴 두정비극방향 검사 시 안와이공선과 아래턱뼈 몸통각도의 상관관계를 이용한 새로운 자세잡이 기준에 관한 연구)

  • Yong-Min Son;Han-Yong Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.335-344
    • /
    • 2024
  • In this study, we aim to investigate the correlation between the lateral images of Korean skulls and the angle between the OML and the Body of the Mandible. Additionally, we seek to provide criteria for the ease of positioning in clinical settings and establish standardized imaging procedures for the PNS Water's view examination. This study was conducted on a total of 202 patients who visited the radiology department of a general hospital and examined the skull lateral radiography. In addition to the patient images, skull phantoms were also utilized, and images were obtained using GC85A and EOS equipment. In this research, abbreviations related to the angle of the Body of Mandible were defined using PACS on lateral images. Measurements were taken for various angles, including ramus of mandible angle(RIA), accurate OML angle(TIA), OML and IR Angle(OIA), total mandibular length(TML), ramus height(RH), the angle between the pogonion, gonion, and condylion(MA). The validity of these measurements was confirmed using the skull phantom in the study. The age-specific average range for RIA was 22.67° to 26.04°, with measurements of 23.14° for males and 24.78° for females. The age-related mean ranges for TIA and OIA were 35.98° to 38.31° and 72.27° to 75.25°, respectively. For males, TIA was 36.74° and OIA was 72.73°, while for females, TIA was 36.43° and OIA was 73.38°. The age-dependent measurements for TML and RH ranged from 85.73 mm to 89.60 mm and 62.60 mm to 70.87 mm, respectively. Male values were 90.54 mm and 70.78 mm, while female values were 85.13 mm and 61.54 mm for TML and RH, respectively. The age-specific average range for MA was 55.95° to 58.63°, with measurements of 57.96° for males and 57.76° for females. Correlation analysis revealed a positive correlation between RIA and OIA, as well as between RIA and TIA. Based on the results of this study, which indicate a positive correlation between the angle of the Body of Mandible and the OML, it can be inferred that adjusting the mandible vertically to align with the imaging receptor may contribute to more accurate image acquisition during PNS Water's view examination. Therefore, it is believed that there is value in utilizing this relationship as a criterion for establishing new positioning standards, which could enhance the utility of a new positioning guide.

Clinical Analysis According to $p21^{Waf1/Cip1}\;and\;p27^{kip1}$ Expression in Gastric Cancer (위암에서의 $p21^{Waf1/Cip1}\;and\;p27^{kip1}$ 단백 발현)

  • Kim, Sin-Sun;Park, Yong-Geun;Jun, Kyong-Hwa;Jung, Hun;Song, Gyo-Young;Kim, Jin-Joo;Chin, Hyung-Min;Kim, Wook;Park, Cho-Hyun;Park, Seung-Man;Lim, Keun-Woo;Kim, Seung-Nam;Jeon, Hae-Myung
    • Journal of Gastric Cancer
    • /
    • v.6 no.1
    • /
    • pp.36-42
    • /
    • 2006
  • Purpose: The $p21^{Waf1/Cip1}$ protein Inhibits the cell cycle by Inhibiting the phosphorylation at the $G1{\rightarrow}S$ check point, and the $p27^{kip1}$ protein similarly performs the suppressor function by controlling the p27-mediated G1 arrest. In this study, we analysed the clinical status and survival rates in correlations with p21 and p27 expression patterns in gastric cancer. Materials and Methods: Between 1993 and 1997, 192 patients who underwent surgeries in Catholic Medical Center were analysed retrospectively in this study. Immunohistochemical staining was performed and if the nuclei of the tumor cells were stained, we assumed those as positive results. Statistical analysis was based on clinicopathological findings and differences in survival rates. Results: The expression rate of p27 was 28.1% and 15.6% in p21 each. The ratio of T1-2(80.0%) was significantly high in p21 (+), but the ratio of T3-4 (50.6%) was slightly high in p21 (-). There was no statistical significance regarding other factors. The results in p27 was not much different from expression rate of p21 in T-stage. In addition, p27 expression in diffuse type (91.3%) was higher than in intestinal type (62.7%) by Lauren's classification (P<0.05). Also, there was no statistical significance in other factors. In the correlation of p21 and p27, p27 was positive when p21 was positive (53.5%). Conversely, p27 was negative when p21 was negative (76.5%, p<0.05). In the p21 and p27 combination test, there was higher rate of T1-2 (87.5%) in p21 (+)/p27 (+), and higher rate of T3-4 (58.1%) in p21 (-)/p27 (-) (P<0.05). Results showed higher rate of intestinal type (100%) in p21 (+)/p27 (+), and diffuse type (87.0%) was dominant in p21 (-)/p27 (-) (P<0.05) by Lauren's classification. Moreover, there was no statistical significance in the 5-year survival rate in the expression of p21 and p27, and the 5-year survival rate was highest in the case of p21 (+)/p27 (+) without statistical significance. Conclusion: In our study, $p21^{Waf1/Cip1}\;and\;p27^{kip1}$ expressed similar patterns. The expression of $p21^{Waf1/Cip1}\;and\;p27^{kip1}$ affected the degree of invasiveness of the tumor, and. Combined examination result revealed the correlation of $p21^{Waf1/Cip1}\;and\;p27^{kip1}$ with Lauren's classification and depth of invasion of the tumor. However, we assumed that little difference between the survival rates depending on expression of $p21^{Waf1/Cip1}\;and\;p27^{kip1}$ has limited their value as predictable prognostic indicators.

  • PDF

The Predictable Factors for the Mortality of Fatal Asthma with Acute Respiratory Failure (호흡부전을 동반한 중증천식환자의 사망 예측 인자)

  • Park, Joo-Hun;Moon, Hee-Bom;Na, Joo-Ock;Song, Hun-Ho;Lim, Chae-Man;Lee, Moo-Song;Shim, Tae-Sun;Lee,, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.3
    • /
    • pp.356-364
    • /
    • 1999
  • Backgrounds: Previous reports have revealed a high morbidity and mortality in fatal asthma patients, especially those treated in the medical intensive care unit(MICU). But it has not been well known about the predictable factors for the mortality of fatal asthma(F A) with acute respiratory failure. In order to define the predictable factors for the mortality of FA at the admission to MICU, we analyzed the relationship between the clinical parameters and the prognosis of FA patients. Methods: A retrospective analysis of all medical records of 59 patients who had admitted for FA to MICU at a tertiary care MICU from January 1992 to March 1997 was performed. Results: Over all mortality rate was 32.2% and 43 patients were mechanically ventilated. In uni-variate analysis, the death group had significantly older age ($66.2{\pm}10.5$ vs. $51.0{\pm}18.8$ year), lower FVC($59.2{\pm}21.1$ vs. $77.6{\pm}23.3%$) and lower $FEV_1$($41.4{\pm}18.8$ vs. $61.l{\pm}23.30%$), and longer total ventilation time ($255.0{\pm}236.3$ vs. $98.1{\pm}120.4$ hour) (p<0.05) compared with the survival group (PFT: best value of recent 1 year). At MICU admission, there were no significant differences in vital signs, $PaCO_2$, $PaO_2/FiO_2$, and $AaDO_2$, in both groups. However, on the second day of MICU, the death group had significantly more rapid pulse rate ($121.6{\pm}22.3$ vs. $105.2{\pm}19.4$ rate/min), elevated $PaCO_2$ ($50.1{\pm}16.5$ vs. $41.8{\pm}12.2 mm Hg$), lower $PaO_2/FiO_2$, ($160.8{\pm}59.8$ vs. $256.6{\pm}78.3 mm Hg$), higher $AaDO_2$ ($181.5{\pm}79.7$ vs. $98.6{\pm}47.9 mm Hg$), and higher APACHE III score ($57.6{\pm}21.1$ vs. $20.3{\pm}13.2$) than survival group (p<0.05). The death group had more frequently associated with pneumonia and anoxic brain damage at admission, and had more frequently developed sepsis during disease progression than the survival group (p<0.05). Multi-variate analysis using APACHE III score and $PaO_2/FiO_2$, ratio on first and second day, age, sex, and pneumonia combined at admission revealed that APACHE III score (40) and $PaO_2/FiO_2$ ratio (<200) on second day were regarded as predictive factors for the mortality of fatal asthma (p<0.05). Conclusions: APACHE III score ($\geq$40) and $PaO_2/FiO_2$ ratio (<200) on the second day of MICU, which might reflect the response of treatment, rather than initially presented clinical parameters would be more important predictable factors of mortality in patients with FA.

  • PDF

Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung (일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교)

  • Lee, Jae-Ho;Chung, Hee-Soon;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.555-568
    • /
    • 1995
  • Background: It is most physiologic to measure the diffusing capacity of the lung by using oxygen, but it is so difficult to measure partial pressure of oxygen in the capillary blood of the lung that in clinical practice it is measured by using carbon monoxide, and single-breath diffusing capacity method is used most widely. However, since the process of withholding the breath for 10 seconds after inspiration to the total lung capacity is very hard to practice for patients who suffer from cough, dyspnea, etc, the intra-breath lung diffusing capacity method which requires a single exhalation of low-flow rate without such process was devised. In this study, we want to know whether or not there is any significant difference in the diffusing capacity of the lung measured by the single-breath and intra-breath methods, and if any, which factors have any influence. Methods: We chose randomly 73 persons without regarding specific disease, and after conducting 3 times the flow-volume curve test, we selected forced vital capacity(FVC), percent of predicted forced vital capacity, forced expiratory volume within 1 second($FEV_1$), percent of forced expiratory volume within 1 second, the ratio of forced expiratory volume within 1 second against forced vital capacity($FEV_1$/FVC) in test which the sum of FVC and $FEV_1$ is biggest. We measured the diffusing capacity of the lung 3 times in each of the single-breath and intra-breath methods at intervals of 5 minutes, and we evaluated which factors have any influence on the difference of the diffusing capacity of the lung between two methods[the mean values(ml/min/mmHg) of difference between two diffusing capacity measured by two methods] by means of the linear regression method, and obtained the following results: Results: 1) Intra-test reproducibility in the single-breath and intra-breath methods was excellent. 2) There was in general a good correlation between the diffusing capacity of the lung measured by a single-breath method and that measured by the intra-breath method, but there was a significant difference between values measured by both methods($1.01{\pm}0.35ml/min/mmHg$, p<0.01) 3) The difference between the diffusing capacity of the lung measured by both methods was not correlated to FVC, but was correlated to $FEV_1$, percent of $FEV_1$, $FEV_1$/FVC and the gradient of methane concentration which is an indicator of distribution of ventilation, and it was found as a result of the multiple regression test, that the effect of $FEV_1$/FVC was most strong(r=-0.4725, p<0.01) 4) In a graphic view of the difference of diffusing capacity measured by single-breath and intra-breath method and $FEV_1$/FVC, it was found that the former was divided into two groups in section where $FEV_1$/FVC is 50~60%, and that there was no significant difference between two methods in the section where $FEV_1$/FVC is equal or more than 60% ($0.05{\pm}0.24ml/min/mmHg$, p>0.1), but there was significant difference in the section, less than 60%($-4.5{\pm}0.34ml/min/mmHg$, p<0.01). 5. The diffusing capacity of the lung measured by the single-breath and intra-breath method was the same in value($24.3{\pm}0.68ml/min/mmHg$) within the normal range(2%/L) of the methane gas gradient, and there was no difference depending on the measuring method, but if the methane concentration gradients exceed 2%/L, the diffusing capacity of the lung measured by single-breath method became $15.0{\pm}0.44ml/min/mmHg$, and that measured by intra-breath method, $11.9{\pm}0.51ml/min/mmHg$, and there was a significant difference between them(p<0.01). Conclusion: Therefore, in case where $FEV_1$/FVC was less than 60%, the diffusing capacity of the lung measured by intra-breath method represented significantly lower value than that by single-breath method, and it was presumed to be caused largely by a defect of ventilation-distribution, but the possibility could not be excluded that the diffusing capacity of the lung might be overestimated in the single-breath method, or the actual reduction of the diffusing capacity of the lung appeared more sensitively in the intra-breath method.

  • PDF

Diagnostic Usefulness of Serum Level of Cyfra 21-1, SCC Antigen and CEA in Lung Cancer (폐암에서 혈중 Cyfra 21-1, SCC 항원 및 CEA의 진단적 유용성)

  • Kim, Kyoung-Ah;Lee, Me-Hwa;Koh, Youn-Suck;Kim, Seon-Hee;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Moon, Dae-Hyuk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.846-854
    • /
    • 1995
  • Background: Cytokeratin 19 is a subunit of cytokeratin intermediate filament expressed in simple epithelia such as respiratory epithelial cells and their malignant counterparts. An immunoradiometric assay is available to detect a fragment of the cytokeratin, referred to as Cyfra 21-1 in the serum. This study was conducted to evaluate the clinical utility of this new marker in the diagnosis of lung cancer compared with established markers of squamous cell carcinoma antigen (SCC Ag) and carcino-embryonic antigen(CEA). In addition, we compared the diagnostic sensitivity and specificity of Cyfra 21-1 with those of SCC Ag in squamous cell carcinoma of the lung. We also measured the level of Cyfra 21-1 in the different stages of squamous cell carcinoma of the lung. Method: We measured Cyfra 21-1(ELSA-CYFRA 21-1), SCC Ag(ABBOTT SCC RIABEAD) and CEA(ELSA2-CEA) in 79 patients with primary lung cancer and in 78 persons as a comparison group including 32 patients with pulmonary tuberculosis, 23 patients with benign lung disease and 23 cases with healthy individual. Cyfra 21-1 is measured by a solid-phase immunoradiometric assay(CIS Bio International, France) based on the two-site sandwich method. SCC Ag is measured by a radioimmunoassay(Abbott Laboratories, USA). CEA is measured by a immunoradiometric assay(CIS Bio International, France). All data were expressed as the mean$\pm$standard deviation. Results: 1) The mean value of Cyfra 21-1 was $18.38{\pm}3.65\;ng/mL$ in the lung cancer and $1.l6{\pm}0.53\;ng/mL$ in the comparison group(p<0.0001). SCC Ag was $3.53{\pm}6.06\;ng/mL$ in the lung cancer and $1.19{\pm}0.5\;ng/mL$ in the comparison group(p<0.01). CEA was $35.03{\pm}13.9\;ng/mL$ in the lung cancer and $2.89{\pm}1.01\;ng/mL$ in the comparison group(p<0.0001). 2) Cyfra 21-1 level in squamous cell carcinoma($31.52{\pm}40.13\;ng/mL$) was higher than that in adenocarcinoma($2.41{\pm}1.34\;ng/mL$)(p<0.0001) and small cell carcinoma($2.15{\pm}2.05\;ng/mL$)(p=0.007). SCC Ag level in squamous cell carcinoma($5.1{\pm}7.68\;ng/mL$) was higher than that in adenocarcinoma($1.36{\pm}0.69\;ng/mL$)(p=0.009) and small cell carcinoma($1.1{\pm}0.24\;ng/mL$) (p=0.024). 3) The level of Cyfra 21-1 was not correlated with the progression of stage in squamous cell carcinoma of the lung. 4) Using the cut-off value of 3.3ng/mL, the diagnostic sensitivity of Cyfra 21-1 was 83% in squamous cell carcinoma, 22% in adenocarcinoma and 17% in small cell carcinoma. The sensitivity of SCC Ag and CEA were 39% and 20%, respectively in squamous cell carcinoma, 11% and 39% in adenocarcinoma, and 0% and 33% in small cell carcinoma. 5) Comparison of the receiver operating characteristics curves(ROC curve) for Cyfra 21-1, SCC Ag and CEA revealed that Cyfra 21-1 showed highest diagnostic sensitivity among them in the diagnosis of lung cancer. Conclusion: Cyfra 21-1 is thought to be a better tumor marker for the diagnosis of lung cancer than SCC Ag and CEA, especially in squamous cell carcinoma of the lung.

  • PDF

Preservation of World Records Heritage in Korea and Further Registry (한국의 세계기록유산 보존 현황 및 과제)

  • Kim, Sung-Soo
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.5 no.2
    • /
    • pp.27-48
    • /
    • 2005
  • This study investigates the current preservation and management of four records and documentary heritage in Korea that is in the UNESCO's Memory of the World Register. The study analyzes their problems and corresponding solutions in digitizing those world records heritages. This study also reviews additional four documentary books in Korea that are in the wish list to add to UNESCO's Memory of the World Register. This study is organized as the following: Chapter 2 examines the value and meanings of world records and documentary heritage in Korea. The registry requirements and procedures of UNESCO's Memory of the World Register are examined. The currently registered records of Korea include Hunmin-Chongum, the Annals of the Choson Dynasty, the Diaries of the Royal Secretariat (Seungjeongwon Ilgi), and Buljo- Jikji-Simche-Yojeol (vol. II). These records heritage's worth and significance are carefully analyzed. For example, Hunmin-Chongum("訓民正音") is consisted of unique and systematic letters. Letters were delicately explained with examples in its original manual at the time of letter's creation, which is an unparalleled case in the world documentary history. The Annals of the Choson Dynasty("朝鮮王朝實錄") are the most comprehensive historic documents that contain the longest period of time in history. Their truthfulness and reliability in describing history give credits to the annals. The Royal Secretariat Diary (called Seungjeongwon-Ilgi("承政院日記")) is the most voluminous primary resources in history, superior to the Annals of Choson Dynasty and Twenty Five Histories in China. Jikji("直指") is the oldest existing book published by movable metal print sets in the world. It evidences the beginning of metal printing in the world printing history and is worthy of being as world heritage. The review of the four registered records confirms that they are valuable world documentary heritage that transfers culture of mankind to next generations and should be preserved carefully and safely without deterioration or loss. Chapter 3 investigates the current status of preservation and management of three repositories that store the four registered records in Korea. The repositories include Kyujanggak Archives in Seoul National University, Pusan Records and Information Center of National Records and Archives Service, and Gansong Art Museum. The quality of their preservation and management are excellent in all of three institutions by the following aspects: 1) detailed security measures are close to perfection 2) archiving practices are very careful by using a special stack room in steady temperature and humidity and depositing it in stack or archival box made of paulownia tree and 3) fire prevention, lighting, and fumigation are thoroughly prepared. Chapter 4 summarizes the status quo of digitization projects of records heritage in Korea. The most important issue related to digitization and database construction on Korean records heritage is likely to set up the standardization of digitization processes and facilities. It is urgently necessary to develop comprehensive standard systems for digitization. Two institutions are closely interested in these tasks: 1) the National Records and Archives Service experienced in developing government records management systems; and 2) the Cultural Heritage Administration interested in digitization of Korean old documents. In collaboration of these two institutions, a new standard system will be designed for digitizing records heritage on Korean Studies. Chapter 5 deals with additional Korean records heritage in the wish list for UNESCO's Memory of the World Register, including: 1) Wooden Printing Blocks(經板) of Koryo-Taejangkyong(高麗大藏經) in Haein Temple(海印寺); 2) Dongui-Bogam("東醫寶鑑") 3) Samguk-Yusa("三國遺事") and 4) Mugujeonggwangdaedaranigyeong. Their world value and importance are examined as followings. Wooden Printing Blocks of Koryo-Taejangkyong in Haein Temple is the worldly oldest wooden printing block of cannon of Buddhism that still exist and was created over 750 years ago. It needs a special conservation treatment to disinfect germs residing in surface and inside of wooden plates. Otherwise, it may be damaged seriously. For its effective conservation and preservation, we hope that UNESCO and Government will schedule special care and budget and join the list of Memory of the Word Register. Dongui-Bogam is the most comprehensive and well-written medical book in the Korean history, summarizing all medical books in Korea and China from the Ancient Times through the early 17th century and concentrating on Korean herb medicine and prescriptions. It is proved as the best clinical guidebook in the 17th century for doctors and practitioners to easily use. The book was also published in China and Japan in the 18th century and greatly influenced the development of practical clinic and medical research in Asia at that time. This is why Dongui Bogam is in the wish list to register to the Memory of the World. Samguk-Yusa is evaluated as one of the most comprehensive history books and treasure sources in Korea, which illustrates foundations of Korean people and covers histories and cultures of ancient Korean peninsula and nearby countries. The book contains the oldest fixed form verse, called Hyang-Ka(鄕歌), and became the origin of Korean literature. In particular, the section of Gi-ee(紀異篇) describes the historical processes of dynasty transition from the first dynasty Gochosun(古朝鮮) to Goguryeo(高句麗) and illustrates the identity of Korean people from its historical origin. This book is worthy of adding to the Memory of the World Register. Mugujeonggwangdaedaranigyeong is the oldest book printed by wooden type plates, and it is estimated to print in between 706 and 751. It contains several reasons and evidence to be worthy of adding to the list of the Memory of the World. It is the greatest documentary heritage that represents the first wooden printing book that still exists in the world as well as illustrates the history of wooden printing in Korea.

MR T2 Map Technique: How to Assess Changes in Cartilage of Patients with Osteoarthritis of the Knee (MR T2 Map 기법을 이용한 슬관절염 환자의 연골 변화 평가)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.298-307
    • /
    • 2009
  • By using the MR T2 map technique, this study intends, first, to measure the change of T2 values of cartilage between healthy people and patients with osteoarthritis and, second, to assess the form and the damage of cartilage in the knee-joint, through which this study would consider the utility of the T2 map technique. Thirty healthy people were selected based on their clinical history and current status and another thirty patients with osteoarthritis of the knee who were screened by simple X-ray from November 2007 to December 2008 were selected. Their T2 Spin Echo (SE hereafter) images for the cartilage of the knee joint were collected by using the T2 SE sequence, one of the multi-echo methods (TR: 1,000 ms; TE values: 6.5, 13, 19.5, 26, 32.5. 40, 45.5, 52). Based on these images, the changes in the signal intensity (SI hereafter) for each section of the cartilage of the knee joint were measured, which yielded average values of T2 through the Origin 7.0 Professional (Northampton, MA 01060 USA). With these T2s, the independent samples T-test was performed by SPSS Window version 12.0 to run the quantitative analysis and to test the statistical significance between the healthy group and the patient group. Closely looking at T2 values for each anterior and lateral articular cartilage of the sagittal plane and the coronal plane, in the sagittal plane, the average T2 of the femoral cartilage in the patient group with arthritis of the knee ($42.22{\pm}2.91$) was higher than the average T2 of the healthy group ($36.26{\pm}5.01$). Also, the average T2 of the tibial cartilage in the patient group ($43.83{\pm}1.43$) was higher than the average T2 in the healthy group ($36.45{\pm}3.15$). In the case of the coronal plane, the average T2 of the medial femoral cartilage in the patient group ($45.65{\pm}7.10$) was higher than the healthy group ($36.49{\pm}8.41$) and so did the average T2 of the anterior tibial cartilage (i.e., $44.46{\pm}3.44$ for the patient group vs. $37.61{\pm}1.97$ for the healthy group). As for the lateral femoral cartilage in the coronal plane, the patient group displayed the higher T2 ($43.41{\pm}4.99$) than the healthy group did ($37.64{\pm}4.02$) and this tendency was similar in the lateral tibial cartilage (i.e., $43.78{\pm}8.08$ for the patient group vs. $36.62{\pm}7.81$ for the healthy group). Along with the morphological MR imaging technique previously used, the T2 map technique seems to help patients with cartilage problems, in particular, those with the arthritis of the knee for early diagnosis by quantitatively analyzing the structural and functional changes of the cartilage.

  • PDF