• Title/Summary/Keyword: Clinical value

Search Result 3,095, Processing Time 0.034 seconds

Patterns of Retear After Repair of the Rotator Cuff - MRI Analysis of 109Cases - (회전근 개 봉합술 후 발생한 재파열의 양상 - 109예의 자기 공명 영상 검사 분석 -)

  • Tae, Suk-Kee;Kim, Young-Sung;Lee, Ho-Min;Park, Pan-Kun
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.16-24
    • /
    • 2012
  • Purpose: This study was designed to investigate the rate of incidence, location and the clinical value of the rotator cuff retear by analyzing MRI scans, which was taken after an arthroscopic rotator cuff repair. Materials and Methods: This study included a total of 109 patients, who underwent a shoulder MRI scan after an average of 10.6 months later from the arthroscopic rotator cuff repair. We only defined the 'retear' when the Sugaya type IV and V was observed in the sagittal section of the MRI. The location of the retear was divided into the medial and lateral areas by the site, which was 1 cm medial to the anchor insertion. We investigated the incidence rate and the location of the retear, in terms of the age, sex, initial tear size and the suture method. Also, we compared the functional score of the retear group and the non-retear group, after an average of 13.9 months follow-up. Results: There were 38 of the 109 patients that showed the rotator cuff retear. Of these patients, 25 were male patients, and 13 were female patients. Of the 38 patients with the rotator cuff retear, 21 patients were included in the <3 cm retear group, and 17 were included in the ${\geqq}3$ cm retear group. At the end of the follow up period, all 109 patients showed a statistical significant improvement in the shoulder functional score. Conclusion: According to the follow up of the MRI scan, which was taken after the rotator cuff repair, the retear rate reached 34.9 %, and there were no significant differences on the age and the suture method. More rotator cuff retear occurred in male patients, and the initial tear size was positively correlated with the incidence rate of the rotator cuff retear. Also, the retear was more frequently observed at the medial side. That is because when the suture was performed, excessive tension was loaded on the medial side of the suture site.

Non-radiologic Methods for Predicting Vesicoureteral Reflux in Childhood Urinary Tract Infection (요로감염 환아에서 비방사선학적 방법에 의한 방광요관역류의 조기 예측에 관한 연구)

  • Jeon Seong-Hoi;Lee K.C.;Yoo Kee-Hwan
    • Childhood Kidney Diseases
    • /
    • v.1 no.1
    • /
    • pp.38-45
    • /
    • 1997
  • Purpose : Vesicoureteral reflux(VUR) in childhood may be the primary cause of recurrent urinary tract infection and renal scarring. Renal ultrasonography, DMSA, and voiding cystourethrogram are the standard clinical methods for detection of vesicoureteral reflux. But these methods have many disadvantages such as invasiveness and high cost. So, we studied to observe the significance of urine ${\beta}_2$-microglobulin in association with other non-radiologic methods for predictng vesicoureteral reflux. Methods : We evaluated 40 patients with urinary tract infection who were admitted to Korea university Hospital from July 1993 to June 1994. Among them, 24 patients revealed urinary tract infection and vesicoureteral reflux(group A), 16 patients revealed only urinary tract infection(group B). Both groups were compared by presence of fever, hematuria, and proteinuria, positivity of CRP, and level of BUN, Cr, GFR by 99mTc-DTPA, urine ${\beta}_2$-microglobulin, 24 hours urine albumin. Results : 1) Among 24 patients who had vesicoureteral reflux, 14 had unilateral VUR, 10 had bilateral VUR, three kidneys with grade I, nine with grade II, eleven with grade III, eleven with grade IV by classification of International Reflux Study Committee. Among them, 14 patients had renal scar, five with type A, five with type B, four with type C, none with type D by Smellie's classification. 2) The mean of GFR, BUN, Cr, 24hrs urine albumin and the presence of hematuria and proteinuria showed no significant difference between group A and group B. The mean of urine ${\beta}_2$ microglobulin in group A and group B were $283.6{\pm}195.8{\mu}g/l$ and $78.7{\pm}48.5{\mu}g/l$ respectively, showing that group A had a higher value than group B (p<0.01). In case of ${\beta}_2$ microglobulin > $120{\mu}g/l$ and CRP(+), the sensitivity was 93.3% and the specificity is 77.8% for detecting of VUR. In case of ${\beta}_2$-microglobulin>$120{\mu}g/l$ and fever(+), the sensitivity was 92.2%, and the specificity was 62.5% for detecting of VUR Conclusions : If the level of urinary ${\beta}_2$-microglobulin is more than 120ug/l in children with urinary tract infection in association with fever(+) or CRP(+), it can predict VUR. So we can use it for early detection of VUR.

  • PDF

Clinical Significance of Hypopharyngeal pH Monitoring in Gastroesophageal Reflux (위식도 역류에 대한 후두인두부에서 산도 검사의 의의)

  • Jeong, Da Woon;Kim, So Hee;Kim, Eun Young;Moon, Kyung Rye
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.8 no.2
    • /
    • pp.143-149
    • /
    • 2005
  • Purpose: The aim of this study was to evaluate the significance of pH monitoring at two levels, hypopharynx and esophagus in gastroesophageal reflux. Methods: 29 patients with pathological gastroesophageal reflux were classified into two groups: Group I had recurrent respiratory symptoms and Group II had not recurrent respiratory symptoms. The ambulatory pH monitoring was performed at the hypopharynx and the esophagus simultaneously with two channel catheter for 18~24 hr. The pathological reflux was defined when the percent of time that pH was below 4.0 exceeding the 95th percentile of normal value. Hypopharyngeal reflux was defined as the pharyngeal pH drops below 4. Results: 39 patients were performed pH monitoring at the level of hypopharynx and esophagus for 24 hours. Among 7 patients with chronic respiratory symptom, 6 patients (85.7%) have pathological esophageal reflux. Among 32 patients without chronic respiratory symptom, 23 patients (71.8%) have pathological esophageal reflux. Thus 29 out of 39 patients (74%) have pathological esophageal reflux. In the Group I, all parameters except the longest episode showed significant differences between hypopharyngeal and esophageal pH monitoring. None of parameters showed significant differences between group I and II in the pharyngeal pH monitoring. Conclusion: Regardless of presence of respiratory symptoms, the pH monitoring at the pharyngeal level in patients with gastroesophageal reflux did not showed any differences compared with the esophageal pH monitoring. Therefore we may reconsider the usefulness of hypopharyngeal pH monitoring in patients with chronic respiratory symptoms.

  • PDF

The Clinical Outcome of Pulmonary Thromboendarterectomy for the Treatment of Chronic Pulmonary Thromboembolism (만성 폐동맥 색전증 환자에서의 폐동맥 내막절제술의 임상적 결과)

  • Bang, Jeong-Hee;Woo, Jong-Soo;Choi, Pil-Jo;Jo, Gwang-Jo;Park, Kwon-Jae;Kim, Si-Ho;Yie, Kil-Soo
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.254-259
    • /
    • 2010
  • Background: Diagnosing chronic pulmonary embolism at an early stage is difficult because of the patient’s nonspecific symptoms. This condition is not prevalent in Korea, and in fact, there have been only a few case reports on this in the Korean medical literature. We analyzed the surgical outcome of performing pulmonary thromboendarterectomy in patients with chronic pulmonary embolism. Material and Method: The study subjects included those patients who underwent surgery for chronic pulmonary embolism from 1996 to 2008. For making the diagnosis, echocardiography, chest CT and a pulmonary perfusion scan were performed on the patients who complained of chronic dyspnea. Result: Pulmonary endarterectomy was performed as follows: by incision via a mid-sternal approach (7 patients); by incision via a left posterolateral approach (1 patient); using the deep hypothermic circulatory arrest technique (4 patients); under ventricular fibrillation (3 patients); and under cardioplegic arrest (1 patient). The postoperative systolic pulmonary artery blood pressure significantly decreased from a preoperative value of $78.9{\pm}14.5\;mmHg$ to $45.6{\pm}17.6\;mmHg$ postoperatively (p=0.000). The degree of tricuspid regurgitation was less than grade II after surgery. Two patients died early on, including one patient who had persistent pulmonary hypertension without improvement and right heart failure. Conclusion: Patients who have chronic pulmonary embolism are known to have a poor prognosis. However, we think that early surgical treatment along with making the proper diagnosis before the aggravation of right heart failure can help improve the quality of a patient's life.

Assessment of Right Ventricular Function in Patients with Chronic Obstructive Pulmonary Disease Using Echocardiographic Tei Index (만성 폐쇄성 폐질환 환자에서 Tei 지수를 이용한 우심실기능 평가)

  • Oh, Yoon-Jung;Shin, Joon-Han;Kim, Deog-Ki;Choi, Young-Hwa;Park, Kwang-Joo;Hwang, Sung-Chul;Lee, Yi-Hyeong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.3
    • /
    • pp.343-352
    • /
    • 2001
  • Background : Advanced chronic obstructive pulmonary disease is characterized by progressive pulmonary hypertension leading to right heart dysfunction, which plays a Important role in clinical evaluation but remains difficult and challenging to quantify. The noninvasive doppler echocardiographic value referred to as the Tei index has been suggested as a simple, reproducible and reliable parameter of the right ventricular function. The purpose of this was to assess the right ventricular function in patients with chronic obstructive pulmonary disease using the Tei index and to evaluate its relationship with the pulmonary functional status. Methods : The study population comprised of 26 patients with chronic obstructive pulmonary disease and 10 normal control subjects. The Tei index was obtained by dividing the sum of the isovolumetric contraction and the relaxation times by the ejection time using a pulsed-wave doppler. It was compared with the other available Doppler echocardiographic parameters of systolic or diastolic function and with the pulmonary function of the patients. Results : The Tei indices of the patients with COPD were significantly higher than those of normal subjects($0.45{\pm}0.17$ vs. $0.27{\pm}0.03$, p<0.01). The isovolumetric contraction time/ejection time($0.32{\pm}0.08$ vs. $0.25{\pm}0.05$, p<0.05), the isovolumetric relaxation time/ejection time($0.29{\pm}0.16$ vs. $0.15{\pm}0.08$, p<0.05)and the preejection period/ejection time ($0.46{\pm}0.10$ vs. $0.38{\pm}0.06$, p<0.05) were prolonged and the ejection time ($255.2{\pm}32.6$ vs. $314.2{\pm}16.5$ msec, p<0.05) was significantly shortened in patients with COPD compared to normal subjects. The tei indices were inversely correlated with the $FEV_1$ (r=-0.46, p<0.05) and were prolonged significantly in patients with a severe obstructive ventilatory dysfunction(less than 35% of predicted $FEV_1$) compared to those with a mild and moderate ventilatory dysfunction. The tei indices showed an inverse correlation to with the ejection time (r=-0.469), the isovolumetric contraction time/ejection time(r=0.453), the isovolumetric relaxation time/ejection time(r=0.896) and the preejection period/ejection time(r=0.480). Conclusion : The tei index appeared to be a useful noninvasive means of evaluating the right ventricular function. It revealed a significant correlation with the pulmonary function in patients with COPD.

  • PDF

Utility of CoaguChek XS for Monitoring the Prothrombin Time (프로트롬빈시간 모니터링을 위한 CoaguChek XS의 유용성)

  • Park, Rojin;Kim, Yong-Hyun;Kwon, Kyung Ock;Na, Jongsung;Won, Yong Soon;Sung, Ki Bum;Lee, Nae-Hee;Choi, Tae Youn;Shin, Jeong Won;Shin, Hee Bong;Lee, Yong-Wha;Lee, You Kyeong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.6
    • /
    • pp.471-475
    • /
    • 2008
  • Background: In order to achieve a maintenance level and to prevent hemorrhagic complications, regular monitoring of the INR is mandatory for patients on oral anticoagulation therapy (OAT). A point-of-care instrument for INR monitoring is convenient for users, but the accuracy of the results has been controversial, and so this calls for exact evaluation of the point-of-care instrument that is used for INR monitoring. Methods: From Aug 2007 through Feb 2008, 85 patients on OAT among the all the patients who were admitted to Soonchunhyang University Bucheon Hospital were involved in this study. Parallel measurements of the PT INR were performed using a CoaguChek-XS and, a CA-7000 laboratory reference instrument and the results were analyzed. In addition, the patients' clinical data, including the diagnosis and the frequency and interval of the INR measurements, were also analyzed. Results: Of the 85 patients, 25 were admitted more than once to undergo INR testing and the mean interval between testing was 8.6 weeks with 39% and 38% of the tests being less than INR 2 units with using the CoaguChek-XS and the reference method, respectively. The coefficients of variation of CoaguChek-XS were 4.50 and 2.45 for the high and low INR patients, respectively. An excellent correlation was found between the two methods with a $R^2$ of 0.966 (p<0.001). Through Bland-Altman analysis, the mean INR difference between the two methods was 0.13 with the limit of agreement being -0.47~+0.72 with a 95% confidence interval. CoaguChek-XS was shown to overestimate the INR value for patients with an increasing INR, as compared to the reference method. Conclusion: CoaguChek-XS demonstrated great precision and accuracy for patients on OAT when compared to the laboratory INR results. Accordingly, the instrument should help to monitor the INR in the patients on OAT.

Shear bond strength of veneer ceramic and colored zirconia by using aqueous metal chloride solutions (염화수화물용액 침지법으로 제작한 유색 지르코니아와 전장도재의 전단결합강도)

  • Yun, Kwi-Dug;Ryu, Su-Kyoung;Vang, Mong-Sook;Yang, Hong-So;Kim, Hyun-Seung;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.151-157
    • /
    • 2010
  • Purpose: The purposes of this study was to evaluates shear bond strength between zirconia core and veneer-ceramic in order to examine the clinical practice of colored zirconia block fabricated by infiltration method into the metal chloride solution. Material and methods: CNU block and $Everest{(R)}$ ZS blank were used. VITA In-$Ceram{(R)}$2000 YZ Coloring liquid (LL1) and 3 aqueous metal chloride solutions containing chromium and molybdenum ingredients were used. 40 zirconia specimens were prepared into cuboid shape ($5{\times}5{\times}10 mm$). All specimens were divided into 5 groups by infiltrating into the coloring liquids. After that, porcelain was build up into the shape of $5{\times}5{\times}4mm^3$, followed by sintering. The maximum loading and shear bond strength was measured. Failure patterns and failure sites were examined. Results: 1. There were no statistical differences in shear bond strength between zirconia blocks (P > .05). 2. There were no statistically significant differences in shear bond strength between non-colored and colored zirconia blocks, while shear bond strength of non-colored zirconia blocks is higher than that of colored specimen (P > .05). 3. In the comparison with shear bond strength among colored zirconia blocks, there were no statistical differences according to kinds of coloring liquid (P > .05). 4. Mixed failure patterns were mainly observed in the failure between zirconia and veneering ceramic. The veneering ceramic failure of all specimens was observed in either interface of zirconia or veneering ceramic. Conclusion: Shear bond strength between colored zirconia and veneering ceramic shows lower tendency than non-colored zirconia, but there was clinically allowable value.

Quality Assurance Program of Electron Beams Using Thermoluminescence Dosimetry (열형광선량계를 이용한 전자선 품질보증 프로그램에 관한 연구)

  • Rah Jeong-Eun;Kim Gwe-Ya;Jeong Hee-Kyo;Shin Dong-Oh;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.62-69
    • /
    • 2005
  • The purpose of this study has been performed to investigate the possibility of external audit program using thermoluminescence dosimetry for electron beam in korea. The TLD system consists of LiF powder, type TLD-700 read with a PCL 3 reader. In order to determine a calibration coefficient of the TLD system, the reference dosimeters are irradiated to 2 Gy in a $^{60}CO$ beam at the KFDA The irradiation is performed under reference conditions is water phantom using the IAEA standard holder for TLD of electron beam. The energy correction factor is determined for LiF powder irradiated of dose to water 2 Gy in electron beams of 6, 9, 12, 16 and 20 MeV (Varian CL 2100C). The dose is determined according to the IAEA TRS-398 and by measurement with a PTW Roos type plane-parallel chamber. The TLD for each electron energy are positioned in water at reference depth. In this study, to verify of the accuracy of dose determination by the TLD system are performed through a 'blind' TLD irradiation. The results of blind test are $2.98\%,\;3.39\%\;and\;0.01\%(1\sigma)$ at 9, 16, 20 MeV, respectively. The value generally agrees within the acceptance level of $5\%$ for electron beam. The results of this study prove the possibility of the TLD quality assurance program for electron beams. It has contributed to the improvement of clinical electron dosimetry in radiotherapy centers.

  • PDF

Study on Tumor Control Probability and Normal Tissue Complication Probability in 3D Conformal Radiotherapy (방사선 입체조형치료에 대한 종양치유확율과 정상조직손상확율에 관한 연구)

  • 추성실
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.227-245
    • /
    • 1998
  • A most appropriate model of 3-D conformal radiotherapy has been induced by clinical evaluation and animal study, and therapeutic gains were evaluated by numerical equation of tumor control probability(TCP) and normal tissue complication probability (NTCP). The radiation dose to the tumor and the adjacent normal organs was accurately evaluated and compared using the dose volume histogram(DVH). The TCP and NTCP was derived from the distribution of given dosage and irradiated volume, and these numbers were used as the biological index for the assessment of the treatment effects. Ten patients with liver disease have been evaluated and 3 dogs were sacrificed for this study. Based on the 3-D images of the tumor and adjacent organs, the optimum radiation dose and the projection direction which could maximize the radiation effect while minimizing the effects to the adjacent organs could be decided. 3). The most effective collimation for the normal adjacent organs was made through the beams eye view with the use of multileaf collimator. When the dose was increased from 50Gy to 70Gy, the TCP for the conventional 2-port radiation and the 5-port multidimensional therapy was 0.982 and 0.995 respectively, while the NTCP was 0.725 and 0.142 respectively, suggesting that the 3-D conformal radiotherapy might be the appropriate therapy to apply sufficient radiation dose to the tumor while minimizing the damages to the normal areas of the liver. Positive correlation was observed between the NTCP and the actual complication of the normal liver in the animal study. The present study suggest that the use of 3-D conformal radiotherapy and the application of the mathematical models of TCP and NTCP may provide the improvements in the treatment of hepatoma with enhanced results.

  • PDF

Expected Values for the Analysis of Accommodation and Vergence Dysfunction of Young Adluts (젊은 성인의 조절 및 이향운동 기능장애 분석을 위한 표준 값)

  • Baarg, Saang-Bai
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.127-134
    • /
    • 2008
  • Purpose: The purpose of this study was to determine the expected values of accommodation and vergence system for analysis of binocular vision. Methods: Seventy three healty subjects without past history of eye disease were selected for this study, Patients showing clinical binocular anomalies including manifest squint and intermittent heterotropia were excluded and data was collected on 54 patients(mean age, 25.3${\pm}$2.7 year). Near point of convergence, distance and near phoiras were measured based on objective deviation angle. And then AC/ A ratio, relative accommodation were measured and all of the data were compared with the Morgan's expected values. Results: The values of distance and near heterophoria were 1.24${\pm}$2.72${\Delta}$ and 2.70${\pm}$4.91${\Delta}$ respectively and the gradient AC/A ratio was 3.92${\pm}$2.17${\Delta}$/D which were all about the same compared with the Morgan's expected values. The values of distance negative fusional convergence was same, however, distance positive fusional convergence was 7${\Delta}$ greater than the Morgan's one. There were no significant differences in the range values of both near vergences while the range of distance vergence was relatively larger than the Morgan's one. Positive relative accommodation was +0.37D greater and negative relative accommodation was -0.63D greater than the Morgan's values. Conclusions: The findings in this study appear that the Morgan's expected values have a possibilities of including considerable proximal convergence value. In comparison with Morgan's values, Korean's normal expected values have much different values of especially BO limit, so if the Morgan's values are directly applied to binocular vision analysis for Korean people, it may lead to an inaccurate binocular vision diagnosis. This results can be used to diagnose the accommodation and vergence system of Korean normal young adults.

  • PDF