• Title/Summary/Keyword: Clinical use

Search Result 5,942, Processing Time 0.038 seconds

A Study on the Sensitivity of Human Rights and the Advocacy Activities of Korean Occupational Therapists (국내 작업치료사의 인권감수성이 옹호활동에 미치는 영향)

  • Kim, Ji-Man;Hong, Ki-Hoon;Lee, Chun-Yeop;Kim, Hee-Jung
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.10 no.2
    • /
    • pp.11-24
    • /
    • 2020
  • Objective : The Human Rights constitute one of the basic pillars of every work where persons are involved, such is the case of the occupational therapy field. Methods : In this study we investigate the human rights sensitivity and the advocacy activities of occupational therapists. The differences according to their characteristics, the relationship and the impact of the human rights sensitivity are examined and presented. Making use of online surveys 116 subjects participated in the study. Results : The measured average of human right sensitivity is 69.00 ± 17.67 point, being them distributed according to the following subcategories: to the perception of the situation corresponds 23.25±5.62 points, to the perception of the consequences 22.75±6.54 points and for the perception of the responsibility 23±6.54 points. In all the cases have been taken in account the equal rights, the right to education in disables, the right to pursue the happiness of the elderly, the right of the disables to have personal freedom, the privacy rights and the privacy rights for mental illness people. According to the working area the Human Right sensitiveness is higher in Seoul than in the Gyeongsang province meanwhile the advocacy activities is higher in Seoul and in Gyeonggi province than in Gyeongsang province. Depending of the type of service, general hospitals and rehabilitation/nursing hospitals showed higher human rights sensitivity than other service organizations According to the working field, occupational therapy group focused in elderly showed higher Human Right sensitivity than other fields. Professionals belonging groups of clinical experience from 3 to 5 years and from 6 to 10 years showed higher advocacy activities than professionals with more than 11 years of experience. A positive correlation was showed between the human rights sensitivity and the advocacy activities. For this situation, the human rights sensitiveness was divided in sub-categories in perception of the situation, perception of the consequences and perception of the responsibility. As showed by the result of multiple regression analyses the advocacy activities of human would grow up in accordance with the increase of the human rights sensitiveness of responsibility perception. Conclusion : Due to the actual lack of information, the collection and study of basic data is fundamental for the development of practical human rights educational programs and to emphasize the role of the defense of the human rights.

Synthesis of Ultrasound Contrast Agent: Characteristics and Size Distribution Analysis (초음파 조영제의 합성 및 합성된 초음파 조영제의 특성 분석)

  • Lee, Hak Jong;Yoon, Tae Jong;Yoon, Young Il
    • Ultrasonography
    • /
    • v.32 no.1
    • /
    • pp.59-65
    • /
    • 2013
  • Purpose: The purpose of this study is to establish the methodology regarding synthesis of ultrasound contrast agent imaging, and to evaluate the characteristics of the synthesized ultrasound contrast agents, including size or degradation interval and image quality. Materials and Methods: The ultrasound contrast agent, composed of liposome and SF6, was synthesized from the mixture solution of $21{\mu}mol$ DPPC (1, 2-Dihexadecanoyl-sn-glycero-3-phosphocholine, $C_{40}H_{80}NO_8P$), $9{\mu}mol$ cholesterol, $1.9{\mu}mol$ of DCP (Dihexadecylphosphate, $[CH_3(CH_2)_{15}O]_2P(O)OH$), and chloroform. After evaporation in a warm water bath and drying during a period of 12-24 hours, the contrast agent was synthesized by the sonication process by addition of buffer and SF6 gas. The size of the contrast agent was controlled by use of either extruder or sonication methods. After synthesis of contrast agents, analysis of the size distribution of the bubbles was performed using dynamic light scattering measurement methods. The degradation curve was also evaluated by changes in the number of contrast agents via light microscopy immediate, 12 hours, 24 hours, 36 hours, 48 hours, 60 hours, 72 hours, and 84 hours after synthesis. For evaluation of the role as an US contrast agent, the echogenicity of the synthesized microbubble was compared with commercially available microbubbles (SonoVue, Bracco, Milan, Italy) using a clinical ultrasound machine and phantom. Results: The contrast agents were synthesized successfully using an evaporation-drying-sonication method. The majority of bubbles showed a mean size of 154.2 nanometers, and they showed marked degradation 24 hours after synthesis. ANOVA test revealed a significant difference among SonoVue, synthesized contrast agent, and saline (p < 0.001). Although no significant difference was observed between SonoVue and the synthesized contrast agent, difference in echogenicity was observed between synthesized contrast agent and saline (p < 0.01). Conclusion: We could synthesize ultrasound contrast agents using an evaporation-drying-sonication method. On the basis of these results, many prospective types of research, such as anticancer drug delivery, gene delivery, including siRNA or microRNA, targeted molecular imaging, and targeted therapy can be performed.

Development and Evaluation of Silicon Passive Layer Dosimeter Based Lead-Monoxide for Measuring Skin Dose (피부선량 측정을 위한 Lead-Monoxide 기반의 Silicon Passive layer PbO 선량계 개발 및 평가)

  • Yang, Seung-Woo;Han, Moo-Jae;Jung, Jae-Hoon;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.781-788
    • /
    • 2021
  • Due to the high sensitivity to radiation, excessive exposure needs to be prevented by accurately measuring the dose irradiated to the skin during radiation therapy. Although clinical trials use dosimeters such as film, OSLD, TLD, glass dosimeter, etc. to measure skin dose, these dosimeters have difficulty in accurate dosimetry on skin curves. In this study, to solve these problems, we developed a skin dosimeter that can be attached according to human flexion and evaluated its response characteristics. For the manufacture of the dosimeter, lead oxide (PbO) with high atomic number (ZPb: 82, ZO: 8) and density (9.53 g/cm3) and silicon binders that can bend according to human flexion were used. In the case of a dosimeter made of PbO material, the performance degradation has been prevented by using parylene and others due to the presence of degradation due to oxidation, but the previously used parylene is affected by bending, so a new form of passive layer was produced and applied to the skin dosimeter. The characteristic evaluation of the skin dosimeter was evaluated by analyzing SEM, reproducibility, and linearity. Through SEM analysis, bending was evaluated, reproducibility and linearity at 6 MeV energy were evaluated, and applicability was assessed with a skin dosimeter. As a result of observing the dosimeter surface through SEM analysis, the parylene passive layer PbO dosimeter with the positive layer raised to the parylene produced cracks on the surface when bent. On the other hand, no crack was observed in the silicon passive layer PbO dosimeter, which was raised to silicon passive layer. In the reproducibility measurement results, the RSD of the silicon passive layer PbO dosimeter was 1.47% which satisfied the evaluation criteria RSD 1.5% and the linearity evaluation results showed the R2 value of 0.9990, which satisfied the evaluation criteria R2 9990. The silicon passive layer PbO dosimeter was evaluated to be applicable to skin dosimeters by demonstrating high signal stability, precision, and accuracy in reproducibility and linearity, without cracking due to bending.

Cementless Total Hip Arthroplasty Using Ceramic Femoral Head on Cross-Linked Ultra-High-Molecular Weight Polyethylene Liner in Patients Older than 65 Years: Minimum Five-Year Follow-Up Results (세라믹 대퇴 골두 및 교차결합 초고분자량 폴리에틸렌 라이너를 이용한 65세 이상 무시멘트형 인공 고관절 전치환술: 최소 5년 중기 추시 결과)

  • Yun, Ho Hyun;Cheong, Ji Young;Sim, Hyun Bo;Park, Jae Hong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.490-497
    • /
    • 2018
  • Purpose: To evaluate the utility of ceramic-on-polyethylene articular bearing surface when cementless total hip arthroplasty is performed in patients older than 65 years through an analysis of the minimum five-year follow-up results using the ceramic femoral head and cross-linked polyethylene liner. Materials and Methods: From March 2010 to September 2012, 51 patients (56 hips) who were older than 65 years were enrolled in this retrospective study. The mean age at surgery was $70.9{\pm}5.1years$ old. A clinical assessment was analyzed using the Harris hip score. For the radiographic assessment, the cup inclination and anteversion, stem alignment, and wear amount were measured. The postoperative complications were also determined. Results: The mean Harris hip score was improved from preoperative 48 points to postoperative 87 points (p<0.05). The mean cup inclination was $40.9^{\circ}{\pm}6.4^{\circ}$ and the mean cup anteversion was $20.3^{\circ}{\pm}8.1^{\circ}$. The mean cup anteversion of the elevated liner-used group (16 cases) was $14.3^{\circ}{\pm}7.9^{\circ}$ and the mean cup anteversion of the neutral liner used group (40 cases) was $22.4^{\circ}{\pm}9.1^{\circ}$ (p<0.05). The mean stem alignment angle was $0^{\circ}$ (range, varus $4^{\circ}$-valgus $4^{\circ}$). The mean linear wear amount was $0.458{\pm}0.041mm$ and the average annual linear wear rate was $0.079{\pm}0.032mm/yr$. Six cases (10.7%) of intraoperative periprosthetic femoral fractures were encountered. Conclusion: Based on these results, the use of a ceramic-on-polyethylene articular bearing surface in elderly patients with cementless total hip arthroplasty is beneficial. On the other hand, careful effort is needed to prevent intraoperative periprosthetic femoral fractures.

A Study on the Necessity Verification of Convex Probe Disinfection (Convex Probe 소독 필요성 검증에 관한 연구)

  • Choi, Kwan-Yong;Yoo, Se-jong;Lee, Jun-ho;Hong, Sung-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.193-200
    • /
    • 2019
  • The study was conducted surveying ultrasound room workers on hospital infection awareness in Daejeon and Choong-chunng region. The contamination of ultrasonic probes used in clinical trials was measured using ATP, and the results were verified after using 70% alcohol sterilization. It was measured on the group's general characteristics and the specific categories such as academic background, job type, having professional certificate and infection education. After the examination, the gel removal and method, disinfection status of the probe and variable correlation analysis were performed to analyze the recognition of the ultrasonic probe disinfection. After examination in ultrasound room, it was found that towels were used the most for cleaning, and the gel container was not replaced for more than three months. After 70% alcohol disinfection, ATP contamination was reduced from $1055.4{\pm}944.2$ to $133.5{\pm}93.2$ and the result was analyzed to be statistically significant.(${\rho}<0.01$) The found bacteria were CNS, Gram positive bacillus, and Micrococcus specs. In order to solve this problem, 70% alcohol sterilization was applied and the bacteria were not detected after the treatment. The research shows that regular training on infection control and efforts to prevent infection are necessary, and that 70% alcohol is effective in disinfect the bacteria. Therefore, the medical institution should provide active hospital infection control education to improve the awareness of hospital infection among workers and contribute to the prevention of patient infection. It is also understood that proper use of the results of this study will help prevent infection by means of ultrasonic probes.

Validation of Electronic Foot Function Index in Patients with Foot and Ankle Disease: A Randomized, Prospective Multicenter Study (족부 족관절 질환 환자에서 전자식 족부 기능 지수의 인증: 임의 배정, 전향적, 다기관 연구)

  • Lee, Dong Yeon;Kim, Yu Mi;Lee, Jun Hyung;Kim, Jin;Kim, Ji-Beom;Kim, Bom Soo;Choi, Gi Won;Seo, Sang Gyo;Kim, Jun Beom;Park, Se-Jin;Kim, Yoon-Chung;Choi, Young Rak;Lee, Dong-Oh;Cho, Jae-Ho;Chun, Dong-Il;Kim, Hyong Nyun;Park, Jae-Yong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.1
    • /
    • pp.24-30
    • /
    • 2019
  • Purpose: To evaluate the efficiency of the electronic foot function index (eFFI) through a prospective, random based, multi-institutional study. Materials and Methods: The study included 227 patients ranging in age from 20 to 79 years, visited for surgery in different 15 institutes, and agreed to volunteer. The patients were assigned randomly into a paper-based evaluated group (n=113) and tablet-based evaluated group (n=114). The evaluation was done on the day of hospital admission and the method was changed on the second day of surgery and re-evaluated. PADAS 2.0 (https://www.proscore.kr) was used as an electronic evaluation program. Results: There were no differences in age and sex in both groups. The intraclass correlation coefficient (ICC) evaluation revealed an eFFI ICC of 0.924, showing that both results were similar. The evaluation time was shorter in the tablet-based group than the paper-based group (paper vs tablet, $3.7{\pm}3.8$ vs $2.3{\pm}1.3minutes$). Thirty-nine patients (17.2%) preferred to use paper and 131 patients (57.7%) preferred the tablet. Fifty-seven patients (25.1%) found both ways to be acceptable. Conclusion: eFFI through tablet devices appears to be more constant than the paper-based program. In addition, it required a shorter amount of time and the patients tended to prefer the tablet-based program. Overall, tablet and cloud system can be beneficial to a clinical study.

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

Incidence and Characteristics of Clostridioides difficile Infection in Children (소아 Clostridioides difficile 감염의 발생률 및 임상양상)

  • Jeong, Heera;Kang, Ji-Man;Ahn, Jong Gyun
    • Pediatric Infection and Vaccine
    • /
    • v.27 no.3
    • /
    • pp.158-170
    • /
    • 2020
  • Purpose: We evaluated the incidence and characteristics of Clostridioides difficile infection (CDI) in Korean children. Methods: Medical records of patients aged 2-18 years and diagnosed with CDI at a tertiary hospital between 2009 and 2018 were analyzed. The patients were classified into three CDI groups: community-acquired (CA), community onset-health care facility-associated (CO-HCFA), and healthcare facility onset (HO). Results: The incidence of CDI increased from 1.00 to 10.01 cases per 10,000 admissions from 2009 to 2018 (P<0.001). As compared to the CA group, the HO group had a higher frequency of operation and malignancy as predisposing factors (40.4% vs. 0.0%, P=0.001; and 27.7% vs. 0.0%, P=0.027, respectively), frequency and number of previous antibiotic use (97.9% vs. 31.3%, P<0.001; and 2 vs. 0, P<0.001, respectively), and median postdiagnosis hospital stay (13 vs. 5 days, P=0.008). The CO-HCFA group had a lower median age and higher frequency of malignancy than the CA group (5 vs. 13 years, P=0.012; and 30.8% vs. 0.0%, P=0.030, respectively). As compared to the HO group, the CA group had a higher frequency of abdominal pain and hematochezia (56.3% vs. 10.6%, P=0.001; and 50.0% vs. 10.6%, P=0.002, respectively), inflammatory bowel disease (68.8% vs. 2.1%, P=0.001), and intravenous metronidazole treatment (37.5% vs. 2.1%, P=0.001). Conclusions: With the increasing incidence of pediatric CDI, awareness regarding its epidemiology and clinical characteristics is important to manage nosocomial infections.

A Study of Waterproofing Evaluation and Effect of UV Protection (UVB/UVA) of Multiple Emulsion Sunblock Cream using Sensory Engeeneering Science (감성공학을 적용한 다중에멀젼 선블록크림의 자외선차단(UVA/B) 효과와 내수성 평가 연구)

  • Kim, In-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.1517-1527
    • /
    • 2020
  • This study is about the UV protection effect and water resistance of a multiple emulsion (W/O/W) sunblock cream applied with emotional engineering and reports an actual industrial case. Multiple emulsion system of sunblock cream has the characteristics of changing to a W/O type that is soft and moist when applied, and has excellent water resistance after absorption. Multiple emulsion cream is a highly functional sunblock cream that has both moisture and water resistance. It is a stable milky white cream with a viscosity of 36,000 cps. The organic sunscreen used for the sunscreen was ethylhexylmethoxycinnamate and bisethylhexyloxyphenolmethoxyphenyltriazine. Hexagonal zinc oxide and titanium dioxide that block both UVB and UVA were used. As a result of measuring the UV protection effect by the in-vitro method, the UV protection effect (SPF) is 78.9 for multiple emulsion cream, 76.7 for W/O cream, and 71.3 for O/W cream. It was found that the blocking effect was different. This obtained the highest effect value in the multiple emulsion. As a clinical (in-vivo) result of the UV protection effect, the SPF value representing the UV protection effect of the sunblock cream developed with a multiple emulsion system was 85.7, and the PA-value that blocks the UVA area was 26.5, and ++++. It was found that it has a corresponding high blocking effect. As a result of the water resistance test, the W/O/W formulation had a high waterproofing resistance of 93.8% even after 4 hours, W/O had 75.4%, and O/W had a low water resistance of 25.3%. In the results of the HUT test, it was found in the order of multiple emulsion sun block cream > hydrophilic cream > lipophilic cream. Based on the research results of this multiple emulsion, it is expected to be highly active as a sunblock cream dedicated to outdoor activities by improving the feeling of use, UV protection index, and water resistance. Therefore, in this study, a multiple emulsion system of sunblock cream is developed and has a characteristic that changes to a W/O type that has a soft and moist feeling when applied, and has excellent water resistance after absorption.

Diagnostic Evaluation of the BioFire® Meningitis/Encephalitis Panel: A Pilot Study Including Febrile Infants Younger than 90 Days (BioFire® Meningitis/Encephalitis Panel의 진단적 유용성 평가: 90일 미만 발열영아에서의 예비 연구)

  • Kim, Kyung Min;Park, Ji Young;Park, Kyoung Un;Sohn, Young Joo;Choi, Youn Young;Han, Mi Seon;Choi, Eun Hwa
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.2
    • /
    • pp.92-100
    • /
    • 2021
  • Purpose: Rapid detection of etiologic organisms is crucial for initiating appropriate therapy in patients with central nervous system (CNS) infection. This study aimed to evaluate the diagnostic value of the BioFire® Meningitis/Encephalitis (ME) panel in detecting etiologic organisms in cerebrospinal fluid (CSF) samples from febrile infants. Methods: CSF samples from infants aged <90 days who were evaluated for fever were collected between January 2016 and July 2019 at the Seoul National University Children's Hospital. We performed BioFire® ME panel testing of CSF samples that had been used for CSF analysis and conventional tests (bacterial culture, Xpert® enterovirus assay, and herpes simplex virus-1 and -2 polymerase chain reaction) and stored at -70℃ until further use. Results: In total, 72 (24 pathogen-identified and 48 pathogen-unidentified) CSF samples were included. Using BioFire® ME panel testing, 41 (85.4%) of the 48 pathogen-unidentified CSF samples yielded negative results and 22 (91.7%) of the 24 pathogen-identified CSF samples yielded the same results (enterovirus in 19, Streptococcus agalactiae in 2, and Streptococcus pneumoniae in 1) as those obtained using the conventional tests, thereby resulting in an overall agreement of 87.5% (63/72). Six of the 7 pathogen-unidentified samples were positive for human parechovirus (HPeV) via BioFire® ME panel testing. Conclusions: Compared with the currently available etiologic tests for CNS infection, BioFire® ME panel testing demonstrated a high agreement score for pathogen-identified samples and enabled HPeV detection in young infants. The clinical utility and cost-effectiveness of BioFire® ME panel testing in children must be evaluated for its wider application.