• Title/Summary/Keyword: Clinical type

Search Result 4,943, Processing Time 0.035 seconds

Antibacterial Effect on Enterococcus Faecalis and Physical Properties of Chitosan Added Calcium Hydroxide Canal Filling Material (키토산 첨가 수산화칼슘 근관 충전재의 Enterococcus Faecalis에 대한 항균 효과 및 물리적 성질)

  • Song, Sol;Kim, Yu-Jin;Lee, Jung-Hwan;Lee, Joonhaeng;Shin, Jisun;Kim, Jongbin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.2
    • /
    • pp.198-208
    • /
    • 2021
  • The aim of this study was to evaluate the antibacterial effect on Enterococcus Faecalis and physical properties of chitosan added calcium hydroxide canal filling material. Low, medium, high molecular weights of chitosan powder were mixed with calcium hydroxide canal filling material. Also, for each molecular weight group, 1.0, 2.0, 5.0 wt% of chitosan powder were added. An overnight culture of E. faecalis was adjusted to 1 × 106 CFU/ml. For test of antibacterial effect, three different molecular weights of 2.0 wt% chitosan and three different concentrations of high molecular weight chitosan were mixed with calcium hydroxide canal filling material. The absorbance of plates was analyzed using spectrophotometer at 570 nm with a reference wavelength of 600 nm. Physical properties such as flow, film thickness and radiopacity were examined according to ISO 6876 : 2012. All molecular weight type of chitosan containing material showed inhibitory effect against E. faecalis growth compared to non-chitosan added calcium hydroxide canal filling material group (p < 0.05). High molecular weight chitosan containing material showed the most antibacterial effect. Also, the antibacterial effect decreased as the incorporated amount of chitosan decreased (p < 0.05). Every molecular weight group of material containing chitosan had a tendency for reduced flow and radiopacity, increased film thickness according to amount of chitosan. Low molecular weight of 1.0 wt% chitosan addition did not show any significant difference of physical properties compared to conventional calcium hydroxide canal filling material. In conclusion, for reinforcement of antibacterial effect against E. faecalis and for favorable physical properties, 2.0 wt% of chitosan adding is recommended. Considering its antibacterial effect of chitosan, further studies are required for clinical application of chitosan in endodontics and pediatric dentistry.

A Study on the Necessity Verification of Convex Probe Disinfection (Convex Probe 소독 필요성 검증에 관한 연구)

  • Choi, Kwan-Yong;Yoo, Se-jong;Lee, Jun-ho;Hong, Sung-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.193-200
    • /
    • 2019
  • The study was conducted surveying ultrasound room workers on hospital infection awareness in Daejeon and Choong-chunng region. The contamination of ultrasonic probes used in clinical trials was measured using ATP, and the results were verified after using 70% alcohol sterilization. It was measured on the group's general characteristics and the specific categories such as academic background, job type, having professional certificate and infection education. After the examination, the gel removal and method, disinfection status of the probe and variable correlation analysis were performed to analyze the recognition of the ultrasonic probe disinfection. After examination in ultrasound room, it was found that towels were used the most for cleaning, and the gel container was not replaced for more than three months. After 70% alcohol disinfection, ATP contamination was reduced from $1055.4{\pm}944.2$ to $133.5{\pm}93.2$ and the result was analyzed to be statistically significant.(${\rho}<0.01$) The found bacteria were CNS, Gram positive bacillus, and Micrococcus specs. In order to solve this problem, 70% alcohol sterilization was applied and the bacteria were not detected after the treatment. The research shows that regular training on infection control and efforts to prevent infection are necessary, and that 70% alcohol is effective in disinfect the bacteria. Therefore, the medical institution should provide active hospital infection control education to improve the awareness of hospital infection among workers and contribute to the prevention of patient infection. It is also understood that proper use of the results of this study will help prevent infection by means of ultrasonic probes.

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Effects of Gadolinium Contrast agent on Bone Mineral Density Measurement using Dual Energy X-ray Absorptiometry (가돌리늄조영제가 이중에너지 X-선 흡수법을 이용한 골밀도검사에 미치는 영향)

  • Lee, Keun-Ohk;Lee, Min-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Radiographic contrast agents are used for diagnostic purposes and are one of the factors affecting measured values in bone density tests. They are absorbed into tissues and have an effect of increasing the measured values of bone density, so they are avoided as much as possible before performing a bone density test. MRI contrast agents, which have different physical properties and mechanisms of action than radiographic contrast agents, are based on gadolinium, a metal element. They have radiopacity characteristics, so MRI are generally performed prior to examination using radiation. The purpose of this study was to investigate the effects of MRI contrast agents on bone mineral density examination using dual energy X-ray absorption. Two types of gadolinium based MRI contrast agents were injected into an acrylic water tank for each volume, and the humanoid spine phantom was inserted and the BMD and T-score from (L1-L4) were analyzed by scanning a total of 30 times, 5 times for each injection type. The average value of the measured total (L1-L4) bone density for each of the two contrast agents was 0.952±0.052, 0.957±0.050, and 0.956±0.05g/㎠, respectively, for the Gadoterate Meglumine component 0mL, 7.5mL and 15mL, when the gadobutrol components were 0mL, 5mL, and 10mL, there was no statistically significant difference at all sites at 0.953±0.001, 0.954±0.001, and 0.945±0.001g/㎠, respectively(p>0.05). The average value of total T-score was -0.46±0.05, -0.4±0, -0.42±0.04 when the Gadoterate Meglumine component was 0mL, 7.5mL and 15mL, respectively. When the Gadobutrol ingredients were 0mL, 5mL and 10mL, there was no statistically significant difference in all areas, with -0.46±0.05, -0.46±0.05, and 0.5±0.00, respectively. In this experiment, the MRI contrast agent was found to have no effect on bone density tests, using the dual-energy X-ray absorption method. There is a limitation in that physical conditions such as kidney and health conditions etc. were not taken into consideration, so further clinical research is expected to be conducted in the future.

A study on the effect of collimator angle on PAN-Pelvis volumetric modulated arc therapy (VMAT) including junction (접합부를 포함한 PAN-전골반암 VMAT 치료 계획 시 콜리메이터 각도의 영향에 관한 고찰)

  • Kim, Hyeon Yeong;Chang, Nam Jun;Jung, Hae Youn;Jeong, Yun Ju;Won, Hui Su;Seok, Jin Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.61-71
    • /
    • 2020
  • Purpose: To investigate the effect of collimator angle on plan quality of PAN-Pelvis Multi-isocenter VMAT plan, dose reproducibility at the junction and impact on set-up error at the junction. Material and method: 10 adult patients with whole pelvis cancer including PAN were selected for the study. Using Trubeam STx equipped with HD MLC, we changed the collimator angle to 20°, 30°, and 45° except 10° which was the default collimator angle in the Eclipse(version 13.7) and all other treatment conditions were set to be the same for each patient and four plans were established also. To evaluate these plans, PTV coverage, coverage index(CVI) and homogeneity index (HI) were compared and clinical indicators for each treatment sites in normal tissues were analyzed. To evaluate dose reproducibility at the junction, the absolute dose was measured using a Falmer type ionization chamber and dose changes at the junction were evaluated by moving the position of the isocenter in and out 1~3mm and setting up the virtual volume at the junction. Result: CVI mean value was PTV-45 0.985±0.004, PTV-55 0.998±0.003 at 45° and HI mean value was PTV-45 1.140±0.074, and PTV-55 1.031±0.074 at 45° which were closest to 1. V20Gy of the kidneys decreased by 9.66% and average dose of bladder and V30 decreased by 1.88% and 2.16% at 45° compared to 10° for the critical organs. The dose value at the junction of the plan and the actual measured were within 0.3% and within tolerance. At the junction, due to set-up error the maximum dose increased to 14.56%, 9.88%, 8.03%, and 7.05%, at 10°, 20°, 30°, 45°, and the minimum dose decreased to 13.18%, 10.91%, 8.42%, and 4.53%, at 10°, 20°, 30°, 45° Conclusion: In terms of CVI, HI of PTV and critical organ protection, overall improved values were shown as the collimator angle increased. The impact on set-up error at the junction by collimator angle decreased as the angle increased and it will help improve the anxiety about the set up error. In conclusion, the collimator angle should be recognized as a factor that can affect the quality of the multi-isocenter VMAT plan and the dose at the junction, and be careful in setting the collimator angle in the treatment plan.

Preservation of the Posterior Ligaments for Preventing Postoperative Spinal Instability in Posterior Decompression of Lumbar Spinal Stenosis: Comparative Study between Port-Hole Decompression and Subtotal Laminectomy (요추부 척추관 협착증의 후방 감압술에서 후방 인대의 보존 여부와 술 후 척추 불안정성과의 연관성: 포트홀(Port-Hole) 감압술과 후궁 아전절제술 간 비교 연구)

  • Jung, Yu-Hun;Na, Hwa-Yeop;Choe, Saehun;Kim, Jin;Lee, Joon-Ha
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.71-77
    • /
    • 2020
  • Purpose: To determine if sparing the interspinous and supraspinous ligaments during posterior decompression for lumbar spinal stenosis is significant in preventing postoperative spinal instability. Materials and Methods: A total of 83 patients who underwent posterior decompression for lumbar spinal stenosis between March 2014 and March 2017 with a minimum one-year follow-up period, were studied retrospectively. The subjects were divided into two groups according to the type of surgery. Fifty-six patients who underwent posterior decompression by the port-hole technique were grouped as A, while 27 patients who underwent posterior decompression by a subtotal laminectomy grouped as B. To evaluate the clinical results, the Oswestry disability index (ODI), visual analogue scale (VAS) for both back pain (VAS-B) and radiating pain (VAS-R), and the walking distance of neurogenic intermittent claudication (NIC) were checked pre- and postoperatively, while simple radiographs of the lateral and flexion-extension view in the standing position were taken preoperatively and then every six months after to measure anteroposterior slippage (slip percentage), the difference in anteroposterior slippage between flexion and extension (dynamic slip percentage), angular displacement, and the difference in angular displacement between flexion and extension (dynamic angular displacement) to evaluate the radiological results. Results: The ODI (from 28.1 to 12.8 in group A, from 27.3 to 12.3 in group B), VAS-B (from 7.0 to 2.6 in group A, from 7.7 to 3.2 in group B), VAS-R (from 8.5 to 2.8 in group A, from 8.7 to 2.9 in group B), and walking distance of NIC (from 118.4 m to 1,496.2 m in group A, from 127.6 m to 1,481.6 m in group B) were improved in both groups. On the other hand, while the other radiologic results showed no differences, the dynamic angular displacement between both groups showed a significant difference postoperatively (group A from 6.2° to 6.7°, group B from 6.5° to 8.4°, p-value=0.019). Conclusion: Removal of the posterior ligaments, including the interspinous and supraspinous ligaments, during posterior decompression of lumbar spinal stenosis can cause a postoperative increase in dynamic angular displacement, which can be prevented by the port-hole technique, which spares these posterior ligaments.

Epidemiologic Study of Frostbites and Its Current Managements in Community Hospital (지역 병원에서 동상 환자에 대한 역학에 관한 연구 및 최근 치료)

  • Kim, Dong Chul;Min, Byung Duk;Kim, Ji Hoon;Chung, Chang Eun;Lee, Chong Kun;Yu, Sung Hoon
    • Journal of the Korean Burn Society
    • /
    • v.24 no.2
    • /
    • pp.21-29
    • /
    • 2021
  • Purpose: Frostbite is a hazard to people exposed to cold environments. With the progression of modern industrial development and change of leisure behavior encountering cold environments, frequent accidental exposure to frostbite injury during work and human behavior is increasing, and the predisposing factors of frostbite were greatly changed than before. The purpose of this study was to make epidemiological analysis, and to review the treatment outcomes of frostbite. Methods: From March 2010 to February 2021, this study has included 27 patients with second- to third-degree frostbite injuries in Advanced Burn Reconstruction Center, Bundang Jesaeng Hosptial. A retrospective study was made about the distribution of age, gender, predisposing factors, prevalent area, type of managements, and the length of treatment period. Results: In our institution, acute management of frostbite patients has included rewarming, anticoagulation therapy (acetylsalicylic acid), and agents to improve vascular perfusion (lipo-prostaglandin E1 [Eglandin®]). The 25 frostbite patients with second-degree frostbite (92.6%) were successfully managed by the conservative treatment alone with a mean of 20.3 days healing time. Two patients with third-degree frostbite (7.4%) also showed good outcomes after surgical reconstruction with a mean of 59 days healing time. In our clinical experiences of third-degree frostbite, definitive surgical reconstruction should be recommended to wait for more than 4~6 weeks for identification of clear demarcation of necrotic tissue caused by frostbite. In this study, 43 frostbite injuries site in 27 frostbite patients occurred. Among them, 15 patients (55.6%) had multiple-site frostbite injury. The most common predisposing cause of frostbite was refrigerant gas accidents (44.4%), followed by outdoor activity in cold environments (40.8%), misapplying ice pack for treatment purposes (7.4%), barefoot walking on the cold ground (3.7%), and loss of consciousness in cold grounds (3.7%). The most prevalent sites of frostbite injuries revealed as the hand (58.1%), followed by the foot (32.6%), face (7.0%), and abdomen (2.3%). And in the winter season from the November to March, the incidence rate of frostbite injuries was high at 74.1%. Conclusion: This study included 27 frostbite patients with 43 frostbite sites since last decade in a single institution at the community hospital. The frostbite patients with second-degree frostbite (92.6%) were successfully healed by the conservative treatment alone with a mean of 20.3 days healing time. The most common predisposing cause of frostbite was refrigerant gas accidents (44.4%), followed by outdoor activity in cold environments, etc. The most prevalent site of frostbite injuries was the hand (58.1%). And the most prevalent seasonal incidence of frostbite was from November to March (74.1%).

Analysis of Central Line-associated Bloodstream Infection among Infants in the Neonatal Intensive Care Unit: A Single Center Study

  • Kim, Minhye;Choi, Sujin;Jung, Young Hwa;Choi, Chang Won;Shin, Myoung-jin;Kim, Eu Suk;Lee, Hyunju
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.3
    • /
    • pp.133-143
    • /
    • 2021
  • Purpose: This study aimed to determine the incidence of central line-associated bloodstream infection (CLABSI) in the neonatal intensive care unit (NICU), evaluate the patients' clinical characteristics, and identify the etiologic agents for guidance in prevention and treatment. Methods: A retrospective chart review study of infants classified as having CLABSI was conducted at the NICU of Seoul National University Bundang Hospital from January 2016 to December 2020. Results: Of the 45 infants, 53 had CLABSIs within a follow-up period of 18,622 catheter days. The incidence of CLABSIs was 2.85 per 1,000 catheter days. The most common catheter type was a peripherally inserted central catheter (n=47, 81%). A total of 57 pathogens were isolated, of which 57.9% (n=33) were Gram-positive bacteria, 36.8% (n=21) were Gram-negative bacteria, and 5.3% (n=3) were Candida spp. The most common pathogens were Staphylococcus aureus (n=12, 21%) and coagulase-negative staphylococci (n=12, 21%), followed by Klebsiella aerogenes (n=8, 14%). The median duration of bacteremia was 2 days, and 19 episodes showed bacteremia for 3 days or more. The mortality rate of infants within 14 days of CLABSI was 13.3% (n=6). Conclusions: This study analyzed the incidence of CLABSI and the distribution of pathogens in the NICU. Continuous monitoring of CLABSI based on active surveillance serves as guidance for empiric antibiotic use and also serves as a tool to assess the necessity for implementation of prevention strategies and their impact.

A Case of Pseudodeficiency in a Potential Late Onset Pompe Disease Carrier, with Double Dual Variant, Each in cis Formation (Pseudodeficiency 및 potential late onset Pompe disease 보인자로 확인된 cis형 dual variant 돌연변이 두 개를 가진 여아 1례)

  • Seung Ho, Kim;Goo Lyeon, Kim;Young Pyo, Chang;Dong Hwan, Lee
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.22 no.2
    • /
    • pp.58-62
    • /
    • 2022
  • Pompe disease (PD) is an autosomal recessive genetic disorder caused by a deficiency of the lysosomal enzyme acid α-glucosidase (GAA). It is easy to hastily diagnose as patients if they have two pathogenic variants. Clinical pathologists misdiagnosed our infant and her mother as PD. Here, we report a case of pseudodeficiency in a potential late-onset Pompe disease (LOPD) carrier with a double dual variant, each in cis formation in a 3-month infant. The person who has two pathogenic variants was diagnosed as a carrier, not a patient. It was first reported in Korea. The patient had: two likely pathogenic heterozygous mutations on exon #4: c.752C>T (p.Ser251Leu), c.761C>T (p.Ser254Leu), and a heterozygous mutation on exon #12: c.1726G>A (p.Gly576Ser), also with a heterozygous mutation on exon #15: c.2065G>A (p.Glu689Lys). By presenting this case we emphasize the possibility of cis formation of genes which may cause pseudodeficiency, and potential LOPD carrier form. Hereby we suggest that thorough evaluation of GAA gene is essential among whom initially diagnosed as PD.

Current Status and Actual Conditions of the Use of Occupational Therapy Evaluation Tools in Relation to the Type of Therapy Institution (국내 아동작업치료 기관별 평가도구 사용 현황 및 실태에 관한 연구)

  • Gil, Young-Suk;Yoo, Doo-Han
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.21 no.1
    • /
    • pp.47-58
    • /
    • 2023
  • Objective : This study aimed to investigate the current status and actual use of assessment tools by institutions in the field of occupational therapy with children in Korea. Methods : The study was conducted with 67 occupational therapists working with children in Korea. To investigate the use of evaluation tools by area, knowledge of the evaluation tools, and desire to participate in further education, the questionnaires used in studies by Lee, Hong, and Park (2018) and Kim (2015) were modified and supplemented according to the child evaluation tools currently in usein institutions in Korea. For data collection, we distributed Google questionnaires to child occupational therapists for 3 weeks using convenience sampling. Excel was used to analyze the use of the evaluation tools according to institution. Technical statistics and frequency analyses were used to verify the general characteristics, evaluation-related information, status of evaluation tool use, knowledge levels relating to evaluation tools, and desire to participate in education. A t-test was used for the evaluation tool status. Results : Welfare centers used the most evaluation tools, with an average of 11.1, followed by university hospitals, rehabilitation hospitals, clinics, and daycare centers. There were differences in the choice of tools used, hospital with the Jebsen-Taylor hand function test and the Wee-FIM (Functional Independence Measure) being the most frequently applied. Centers, daycare centers, and welfare center the Sensory Profile test and clinical observation were also used often. Regarding the level of knowledge of evaluation tools and the desire to participate further in education, 30 (44.8%) of the respondents had not completed their education, and 42 (62.7%) rated their knowledge level as generally low. When asked about the importance of using a manual to guide them in their use of evaluation tools, 66 (98.6%) answered positively, and 66 (98.6%) answered that they needed specialized training in the use of evaluation tools. Conclusion : This study makes it possible to understand the use and status of evaluation tools as used by different institutions in Korea in the field of child occupational therapy It is anticipated that it will provide the basis for introducing existing evaluation tools and preparing new evaluation tools to be used in this field in Korea.