The Acoustic Severity Index in the Pathologic Voice (음성장애에 대한 음향학적 중등도 지표)

  • Hong, Ki-Hwan;Kim, Hyun-Ki;Yang, Yoon-Soo
    • Speech Sciences
    • /
    • v.10 no.4
    • /
    • pp.201-219
    • /
    • 2003
  • Background: The perceptual assessment is generally performed by the voice specialist. The objective evaluation is performed in a voice laboratory. Research in voice laboratories has generated a variety of different objective tests and parameters. The perceptual evaluation is one of the most controversial topics in voice research. Review of literature reveals a wide variety of rating scales and reliability data fluctuating from study to study. Unfortunately, there is no widely accepted valid method for classifying voice disorders and assessing outcome after voice treatment. Objectives: The goals of this research were to identify important objective acoustic parameters of vocal quality, and to establish an objective and quantitative correlate of the perceived vocal quality. Materials and Methods : We evaluated the voice analyzed data from 122 dysphonic patients and 20 normal volunteers. A computerized speech lab. 4300B(CSL) was used to carry out the analysis of each voice sample. Results: Three dysphonia severity indices(DSI) were created using discriminant analysis. DSI is based on the weighted combination of the following selected set of acoustic parameters: absolute jitter(Jita in us), smoothed pitch period perturbation (sPPQ in %), amplitude perturbation quotient(APQ in %), soft phonation index(SPI), average fundamental frequency(Fo in Hz), lowest fundamental frequency(Flo in Hz), and smoothed amplitude perturbation quotient(sAPQ in %). The DSI, being the discriminating rule calculated by the logistic regression, consists of three equation based on statistically significant acoustic parameters. Three DSI were created to reflects best the degree of hoarseness as expressed by G from the GRBAS scale. The more positive this DSI is for a patient, the worse the vocal quality. The more it is negative, the better it is. The effect of sex is included implicitly in the DSI-1 and DSI-2, so that a separate DSI-1 and DSI-2 for males and females need not be used. The DSI is objective because no perceptual input is required for its calculation. Conculsion : This research demonstrates that the voice function values calculated from three different multivariate objective dysphonia severity indices are significantly associated with subjective voice assessments. These multivariate objective dysphonia severity indices may be appropriate for use in clinical trials and outcomes research on treatment effectiveness for voice disorders.

  • PDF

The Measurement and Estimation of Minimum Flash Point Behavior for Binary Mixtures Using Tag Open-Cup Tester (Tag 개방식 장치를 이용한 이성분계 혼합물의 최소인화점 현상의 측정 및 예측)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.50-55
    • /
    • 2008
  • The flash points for the systems, ethlybenzene+n-butanol and ethlybenzene+n-hexanol, were measured by using Tag open-cup tester (ASTM D1310-86). These binary mixtures exhibited MFPB (minimum flash point behavior), which leads to the minimum on the flash point vs composition curve. The experimental data were compared with the values calculated by the Raoult's law, the UNIQUAC equation and the NRTL equation. The calculated values based on the UNIQUAC and NRTL equations were found to be better than those based on the Raoult's law. It was concluded that the UNIQUAC and NRTL equations were more effective than the Raoult' law at describing the activity coefficients for nonideal solution such as the ethlybenzene+n-butanol and ethlybenzene+n-hexanol systems. And the predictive curve of the flash point prediction model based on the NRTL equation described the experimentally-derived data more effectively than was the case when the prediction model was based upon the UNIQUAC equation.

  • PDF

Local Residents' Levels of Perception of Health and Happiness according to Whether or Not They Have Experienced Public Health Education(Smoking, Drinking, Nutrition) (지역주민들의 보건교육(흡연, 음주, 영양)경험 유무에 따른 주관적 건강인식수준과 주관적 행복감)

  • Yoon, Hyunseo;Park, Chungmu;Chun, Jinho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.4
    • /
    • pp.101-110
    • /
    • 2018
  • Purpose : This study aimed to analyze the relationship between local residents' experience of public health education on smoking, drinking, and nutrition and their perceptions of health and happiness, thereby providing data for improving the levels of residents' perceptions of health and happiness through the expansion of public health education. Methods : This study used 2017 data on the health of local communities in Gyeongsangnam-do. SPSS (version 25.0) was employed for the statistical analysis. A t-test and an analysis of variance were conducted in order to examine the levels of local residents' perceptions of health and happiness according to their general characteristics and whether or not they had received public health education on smoking, drinking, and nutrition. Results : Those who resided in a city, were younger, earned money, had high educational background, and had high income level had much experience on smoking, drinking, and nutrition education. Those who lived in a county, were males, were younger, had a high level of education, earned money, and had high income level felt a high level of subjective happiness. Residents who had experienced smoking, drinking, and nutrition education had a high level of subjective perception of general health and oral health. The subjects' experience of public health education was positively correlated with their levels of perception of their health and happiness. Conclusion : Education on smoking, drinking, and nutrition for local residents does not merely provide them with knowledge but also it is conductive to improving their quality of life. Therefore, more opportunities for a larger number of people to receive public health education on diverse topics should be given to increase their levels of happiness.

Hematologic and Serological Investigation of Effect on Gyeongokgo in Healthy Individuals : a Randomized, Subject-assessor-blind, Placebo-controlled, Single-center Pilot Study

  • Sunwoo, Yun-Young;Kim, Hye Jung;Kim, Ja Young;Yang, Na Rae;Lee, Jin Hyun;Park, Tae Yong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.33 no.4
    • /
    • pp.239-248
    • /
    • 2019
  • There are no published data on Gyeongokgo (GOK) safety or efficacy despite being commonly use. The Gyeongokgo (GOK) is commonly used in traditional Korean medicine to promote a health qi and blood, but their objective data was not sufficient in clinical field. To investigate the safety and efficacy of GOK with hematologic and serologic testing and the change of the quality of life in healthy individuals. Randomized, subject-assessor-blind, placebo-controlled, single-center pilot study Participants and Interventions 29 healthy volunteer subjects were randomly placed into the GOK group (n = 20) or placebo control group (n = 9) and instructed to take one treatment packet (GOK or placebo) twice daily for 4 weeks. Subjects were assessed using the Fatigue Severity Scale (FSS) and Short Form 36 Health Survey (SF-36) and underwent hematologic and serologic tests and body composition analysis. The FSS total score (p = 0.093) and SF-36 general health index (p = 0.002) were improved following treatment in the GOK group. Post-treatment thyroid-stimulating hormone levels were increased in the GOK group compared with pre-treatment levels (p = 0.0042). C-reactive protein levels decreased (p = 0.0256) in the GOK group compared with that the placebo group. In time-series tests, GOK did not affect post-prandial serum triglycerides, glucose, insulin, or C-peptide levels. Notably, elevations in serum fasting triglycerides at 2- (p = 0.0333) and 4-hours (p = 0.0414) post-prandial were lower than those in the placebo group. GOK reduced fatigue levels and did not significantly affect laboratory test results performed to measure safety, serum glucose, and lipid profiles. Post-meal triglyceride levels were effectively reduced with treatment.

Distinctive Features of Hepatic Steatosis in Children: Is It Primary or Secondary to Inborn Errors of Metabolism?

  • Karhan, Asuman Nur;Hizarcioglu-Gulsen, Hayriye;Gumus, Ersin;Akcoren, Zuhal;Demir, Hulya;Saltik-Temizel, Inci Nur;Orhan, Diclehan;Ozen, Hasan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.24 no.6
    • /
    • pp.518-527
    • /
    • 2021
  • Purpose: The incidence of hepatic steatosis among children has been increasing; however, data distinguishing simple steatosis from a more complex disorder are lacking. Methods: This study identified the etiologies resulting in hepatic steatosis through a retrospective review of pediatric liver biopsies performed in the last 10 years. A total of 158 patients with hepatic steatosis proven by histopathological evaluation were enrolled in the study, and baseline demographic features, anthropometric measurements, physical examination findings, laboratory data, ultrasonographic findings, and liver histopathologies were noted. Results: The two most common diagnoses were inborn errors of metabolism (IEM) (52.5%) and nonalcoholic fatty liver disease/steatohepatitis (NAFLD/NASH) (29.7%). The three most common diseases in the IEM group were glycogen storage disorders, Wilson's disease, and mitochondrial disease. The rates of consanguineous marriage (75.6%; odds ratio [OR], 26.040) and positive family history (26.5%; OR, 8.115) were significantly higher (p=0.002, p<0.001, respectively) in the IEM group than those in the NAFLD/NASH group. Younger age (p=0.001), normal anthropometric measurements (p=0.03), increased aspartate aminotransferase levels (p<0.001), triglyceride levels (p=0.001), and cholestatic biochemical parameters with disrupted liver function tests, as well as severe liver destruction of hepatic architecture, cholestasis, fibrosis, and nodule formation, were also common in the IEM group. Conclusion: Parents with consanguinity and positive family history, together with clinical and biochemical findings, may provide a high index of suspicion for IEM to distinguish primary steatosis from the consequence of a more complex disorder.

Determination of Flash Point for n-Octane+n-Nonane and n-Nonane+n-Decane Systems by Seta flash Apparatus (Seta flash 장치에 의한 n-Octane + n-Nonane계 및 n-Nonane + n-Decane계의 인화점 결정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.11-17
    • /
    • 2020
  • In order to guarantee safe storage and transportation of a flammable liquid solution, it is very important to know its flash point information. In this paper, flash points of n-octane+n-nonane system and n-nonane+n-decane system were measured by Seta flash apparatus and an empirical equation is proposed for the accurate estimation of flash point. Empirical equation is used to predict flash point of n-octane+n-nonane system and n-nonane+n-decane system, which were also compared to Unifac-based model. Absolute average errors of flash point data predicted by Unifac-based model are 0.7℃ and 0.6℃ for n-octane+n-nonane system and n-nonane+n-decane system, respectively. Absolute average errors of flash point data predicted by empirical equation are 0.2℃ and 0.4℃ for n-octane+n-nonane system and n-nonane+n-decane system, respectively. In conclusion, empirical equation proposed in this paper, presented the most satisfactory.

Prediction of Lung Cancer Based on Serum Biomarkers by Gene Expression Programming Methods

  • Yu, Zhuang;Chen, Xiao-Zheng;Cui, Lian-Hua;Si, Hong-Zong;Lu, Hai-Jiao;Liu, Shi-Hai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9367-9373
    • /
    • 2014
  • In diagnosis of lung cancer, rapid distinction between small cell lung cancer (SCLC) and non-small cell lung cancer (NSCLC) tumors is very important. Serum markers, including lactate dehydrogenase (LDH), C-reactive protein (CRP), carcino-embryonic antigen (CEA), neurone specific enolase (NSE) and Cyfra21-1, are reported to reflect lung cancer characteristics. In this study classification of lung tumors was made based on biomarkers (measured in 120 NSCLC and 60 SCLC patients) by setting up optimal biomarker joint models with a powerful computerized tool - gene expression programming (GEP). GEP is a learning algorithm that combines the advantages of genetic programming (GP) and genetic algorithms (GA). It specifically focuses on relationships between variables in sets of data and then builds models to explain these relationships, and has been successfully used in formula finding and function mining. As a basis for defining a GEP environment for SCLC and NSCLC prediction, three explicit predictive models were constructed. CEA and NSE are requentlyused lung cancer markers in clinical trials, CRP, LDH and Cyfra21-1 have significant meaning in lung cancer, basis on CEA and NSE we set up three GEP models-GEP 1(CEA, NSE, Cyfra21-1), GEP2 (CEA, NSE, LDH), GEP3 (CEA, NSE, CRP). The best classification result of GEP gained when CEA, NSE and Cyfra21-1 were combined: 128 of 135 subjects in the training set and 40 of 45 subjects in the test set were classified correctly, the accuracy rate is 94.8% in training set; on collection of samples for testing, the accuracy rate is 88.9%. With GEP2, the accuracy was significantly decreased by 1.5% and 6.6% in training set and test set, in GEP3 was 0.82% and 4.45% respectively. Serum Cyfra21-1 is a useful and sensitive serum biomarker in discriminating between NSCLC and SCLC. GEP modeling is a promising and excellent tool in diagnosis of lung cancer.

Determination of Beam Quality Correction Factors for the PTW-Markus Chamber for Electron Beam Qualities R50=1.0 and 1.4 g/cm2 (전자선 선질 R50=1.0과 1.4 g/cm2에 대한 PTW-Markus 전리함의 선질보정인자 결정에 관한 연구)

  • Kim, Me Young;Rhee, Dong Joo;Moon, Young Min;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.178-184
    • /
    • 2015
  • The Markus ionization chamber(R) is a small plane parallel ionization chamber widely used in clinical electron beam dosimetry. Plane parallel chambers were recommended for low energy electron dosimetry with the beam quality at $R_{50}<4.0g/cm^2$ (${\bar{E}}{\approx}10MeV$) according to TRS-398 protocol. However, the quality correction factors ($k_{Q,Q_0}$) of the Markus chamber was not presented in TRS-398 protocol for electron beam quality at $R_{50}<2.0g/cm^2$ (${\bar{E}}{\approx}4MeV$). In this study, the $k_{Q,Q_0}$ factors of the Markus chambers (PTW-34045) for beam qualities at $R_{50}=1.0$, 1.4, 2.0, 2.5, 3.0, and $5.0g/cm^2$ were determined by Monte Carlo calculations (DOSRZnrc/EGSnrc) and the dosimetric formalism of quality correction factor. The derived $k_{Q,Q_0}$ values were evaluated using the produced data based on TRS-398 and TG-51 protocols and known values for the Markus chamber.

Evaluation of DNA Double Strand Breaks in Human and Mouse Lymphocyte Following ${\gamma}-Irradiation$ (${\gamma}-Ray$ 조사에 따른 사람의 정상임파구와 마우스 정상임파구의 DNA Double Strand Break 발생율에 대한 비교분석)

  • Kim Tae Hwan;Kim Sung Ho;Chung In Yong;Cho Chul Koo;Ko Kyung Hwan;Yoo Seong Yul
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.219-225
    • /
    • 1993
  • The evaluation of radiation-induced DNA double strand breaks (DSB) was made following irradiation of human lymphocytes, murine lymphocytes and EL-4 leukemia cells over a wide dose range of $^{60}Co\;{gamma}-rays.$ In lipopolysaccharide (LPS) or phytohemagglutinin (PHA)-stimulated murine lymphocytes, the slopes of the stand scission factor (SSF) revealed that lymphocytes with LPS increased DNA DSB formation by a factor of 1.432 (p<0.005). Furthermore, strand break production was relatively inefficient in the T lymphocytes compared to the B lymuhocytes. And EL-4 leukemia cells were found to form significantly more DNA DSB to a greater extent than normal lymphocytes (p<0.005). The in vitro studies of the intrinsic radiosensitivity between human lymphocytes and murine lymphocytes showed similar phasic kinetics. However, murine lymphocytes were lower in DNA DSB formation and higher in the relative radiation dose of 10 percent DNA strand breaks at 3.5 hours following ${gamma}-irradiation$ than human lymphocytes. Though it is difficult to interpret these results, these differences may be result from environmental and genetic factors. From our data, if complementary explanations for this difference will be proposed, the differences in the dose-effect relationship for the induction of DSB between humans and mice must be related to interspecies variations in the physiological condition of the peripheral blood in vitro and not to differences in the intrinsic radiation sensitivity of the lymphocytes. These results can be estimated on the basis of dose-effect correlation enabling the interpretation of clinical response and the radiobiological parameters of cytometrical assessment.

  • PDF

The Relationship between the Progression of Chronic Kidney Disease and Beta Cell Function in Non-Diabetic Korean Adults (대한민국 비당뇨 성인에서 만성신장질환과 인슐린저항성 및 베타세포기능의 관련성)

  • Kim, Hyung Rag
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.3
    • /
    • pp.165-171
    • /
    • 2020
  • This study examined the relationship between chronic kidney disease (CKD) and the homeostasis model assessment of insulin resistance (HOMA-IR) and beta-cell function (HOMA-B) in non-diabetic Korean adults. This study included 4,380 adults aged 20 or older (50.32±16.14) using the 2015 Korea National Health and Nutrition Examination Survey (KNHANES) data, which represents the national data in Korea. The present study had several key findings. First, in terms of HOMA-IR, after adjusting for the related variables (Model 4), the HOMA-IR (M±SE, 95% confidence interval [CI]) in group 1 (G1; estimated glomerular filtration rate [eGFR], ≥90 mL/min/1.73 ㎡), group 2 (G2; eGFR, 60~89 mL/min/1.73 ㎡), group 3a (G3a; eGFR, 30~59 mL/min/1.73 ㎡), and ≥group 3b (≥G3b; eGFR, <30 mL/min/1.73 ㎡) were 1.78±0.03 (1.73~1.83), 1.87±0.03 (1.81~1.93), 2.16±0.13 (1.91~2.42), and 2.59±0.24 (2.12~3.06), respectively. The HOMA-IR was positively associated with the progression of CKD (P<0.001). Second, in terms of the HOMA-B, after adjusting for the related variables (Model 4), the HOMA-B (M±SE, 95% CI) in G1, G2, G3a, and ≥G3b were 87.46±1.21 (85.08~89.84), 89.11±1.38 (86.40~91.81), 104.82±5.91 (93.23~116.42), and 123.97±10.87 (102.66~145.29), respectively. HOMA-B was positively associated with the progression of CKD (P<0.001). Both insulin resistance and the beta-cell function were positively associated with CKD in non-diabetic Korean adults.