Anomaly Detection in Medical Wireless Sensor Networks

  • Salem, Osman;Liu, Yaning;Mehaoua, Ahmed
    • Journal of Computing Science and Engineering
    • /
    • 제7권4호
    • /
    • pp.272-284
    • /
    • 2013
  • In this paper, we propose a new framework for anomaly detection in medical wireless sensor networks, which are used for remote monitoring of patient vital signs. The proposed framework performs sequential data analysis on a mini gateway used as a base station to detect abnormal changes and to cope with unreliable measurements in collected data without prior knowledge of anomalous events or normal data patterns. The proposed approach is based on the Mahalanobis distance for spatial analysis, and a kernel density estimator for the identification of abnormal temporal patterns. Our main objective is to distinguish between faulty measurements and clinical emergencies in order to reduce false alarms triggered by faulty measurements or ill-behaved sensors. Our experimental results on both real and synthetic medical datasets show that the proposed approach can achieve good detection accuracy with a low false alarm rate (less than 5.5%).

Vancomycin Therapeutic Drug Monitoring 운영 실태 조사와 업무 개선 방안 (An Improvement Plan with Assessment of Therapeutic Drug Monitoring Service for Vancomycin)

  • 김해숙;이숙향
    • 한국임상약학회지
    • /
    • 제19권2호
    • /
    • pp.120-130
    • /
    • 2009
  • The objective of this study was to analyze and to improve therapeutic drug monitoring(TDM) service of vancomycin in a local hospital. Patients with TDM service between September 2005 and December 2008 were included and the data were collected for vancomycin use and components of TDM. During that period, 421 cases of TDM service of vancomycin in 236 patients were retrospectively reviewed. The first dosages of vancomycin were appropriate in 135(57.2%) patients and administration of vancomycin was discontinued in 126(53.4%) patients due to therapeutic failure or adverse drug reaction. MRSA was identified in 191(80.9%) patients and 135(70.7%) samples for the identification were sputum. According to the TDM reports, 232(55.1%) serum samples were obtained at the steady-state conditions and 55.5% of the samples that were drawn before the steady-state was due to the physician's inappropriate knowledge about the steady-state. Based on the time of vancomycin administration, 35.8% of the samples were not obtained at the recommended sampling time. For the patients in general wards, the most common reason for the incorrect samples was routine serum sampling by the laboratory medicine phlebotomists between 6 and 8 a.m. except sunday. In contrast, samples drawn by nurses or physicians at inappropriate time were the most common reason for the incorrect samples with patients in the intensive care units. Physicians accepted 68.5% of the recommendations for vancomycin dosage and administration. In conclusion, TDM service of vancomycin needs to be improved in inappropriate sampling time and vancomycin dosage. For solving these problems, current team made of TDM pharmacists and physicians of laboratory medicine can be expanded to include a physician of infectious diseases, nurses and laboratory medicine phlebotomists as new members. Through the TDM service of vancomycin by the new team, we can settle the problems and make the guideline for the scientific controversies associated with therapeutic monitoring of vancomycin.

  • PDF

Contributions of CYP2C9/CYP2C19 Genotypes and Drug Interaction to the Phenytoin Treatment in the Korean Epileptic Patients in the Clinical Setting

  • Lee, Soo-Youn;Lee, Seung-Tae;Kim, Jong-Won
    • BMB Reports
    • /
    • 제40권3호
    • /
    • pp.448-452
    • /
    • 2007
  • We examined the contribution of CYP2C9 and CYP2C19 genotypes and drug interactions to the phenytoin metabolism among 97 Korean epileptic patients to determine if pharmacogenetic testing could be utilized in routine clinical practice. The CYP2C9 polymorphism is a wellknown major genetic factor responsible for phenytoin metabolism. The CYP219 polymorphism, with a high incidence of variant alleles, has a minor influence on phenytoin treated Koran patients. Using a multiple regression model for evaluation of the CYP2C9 and CYP2C19 genotypes, together with other non-genetic variables, we explained 39.6% of the variance in serum phenytoin levels. Incorporation of genotyping for CYP2C9 and CYP2C19 into a clinical practice may be of some help in the determination of phenytoin dosage. However, because concurrent drug treatment is common in patients taking phenytoin and many environmental factors are likely to play a role in drug metabolism, these factors may overwhelm the relevance of CYP polymorphisms in the clinical setting. Further investigations with an approach to dose assessment that includes comprehensive interpretation of both pharmacogenetic and pharmacokinetic data along with understanding of the mechanism of drug interactions in dosage adjustment is warranted.

FIPA-OS를 사용한 지능형 CCOW 서비스 (Agent based CCOW Service Using FIPA-OS)

  • 송준현;김일곤;조훈;곽연식
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2003년도 가을 학술발표논문집 Vol.30 No.2 (2)
    • /
    • pp.760-762
    • /
    • 2003
  • HL7(Health Level 7)은 보건의료 분야에서 ANSI에서 승인한 SDO(Standards Developing Organization)들 중의 하나이다. 대부분의 SDO들은 약제. 의료 장비 이미지, 보험 처리 등과 같은 보건의료 분야에서의 표준을 만든다. HL7의 영역은 진료와 병원 행정적인 부분이다. HL7에서는 Version2.3, Version2.4, Version3.0 등을 포함해 Data Model. Arden Syntax, CCOW(Common Context Object Workgroup) CDA(Clinical Document Architecture) 등의 표준을 만들어 나간다. 본 논문에서는 이 표준들 중 CCOW에 대해 알아보고. 기존 Agent System에 좀 더 지능적이고 자율적인 CCOW 서비스를 제공하는 방안을 알아본다.

  • PDF

울혈성 심부전 환자에서 N-Terminal Probrain-type Natriuretic Peptide의 진단적 유용성 (Diagnostic Usefulness of N-Terminal Probrain-type Natriuretic Peptide to Detect Congestive Heart Failure Patients)

  • 손계성
    • 대한임상검사과학회지
    • /
    • 제37권2호
    • /
    • pp.88-95
    • /
    • 2005
  • Even though the echocardiograph has been recognized as the method of choice among various diagnostic tools to detect congestive heart failure (CHF), there were some limitations in relation to the consumption of time, labor and process. We analyzed results of N-terminal probrain-type natriuretic peptide (NT-proBNP) and various parameters of the echocardiographic findings to clarify the diagnostic usefulness of NT-proBNP in detecting patients with CHF. We analyzed the sera from total of 242 cases from in-patients and out-patients, which were requested from the cardiovascular section of department of Internal Medicine at Chungnam National University Hospital from March 2003 to May 2004. The procedures were performed in order as shown below; sampling, NT-proBNP analysis, data acquisition and data analysis. All data including personal information and echocardiographic findings ware acquired by medical record review. When classifying the study population into six groups according to the degree of left ventricular ejection fraction (LVEF), the serum level of NT-proBNP was higher in the group with 51-60% of LVEF (P=0.023). There were low correlation between the serum level of NT-proBNP and various parameters of the echocardiographic findings with LVESD (r=0.1513), LVEDD (r=0.0831), LVEF (r=0.2035), IVST (r=0.03) and LVPWT (r=0.0728), respectively. When comparing NT-proBNP with atrial and/or ventricular enlargement, the patient group with both left atrial and left ventricular enlargement (p=0.186) or only left atrial (p=0.105) or only left ventricular enlargement (p=0.256) showed higher level of NT-proBNP without statistical significance than patient group with no enlargement. Searching the optimal cutoff of the serum level of NT-proBNP, the sensitivity (98.9%) and the specificity (100%) was highest at the cutoff of 300 pg/mL than any other cutoffs. These findings suggested that the analysis of NT-proBNP in serum might detect the patients with CHF earlier than with the echocardiograph, especially in patients with asymptomatic or mild symptomatic CHF. In conclusion, NT-proBNP test was proved to be clinically useful to diagnose CHF patients.

  • PDF

Evaluation of different approaches for using a laser scanner in digitization of dental impressions

  • Lee, Wan-Sun;Kim, Woong-Chul;Kim, Hae-Young;Kim, Wook-Tae;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.22-29
    • /
    • 2014
  • PURPOSE. This study aimed to investigate the potential clinical application of digitized silicone rubber impressions by comparing the accuracy of zirconia 3-unit fixed partial dentures (FPDs) fabricated from 2 types of data (working model and impression) obtained from a laser scanner. MATERIALS AND METHODS. Ten working models and impressions were prepared with epoxy resin and vinyl polysiloxane, respectively. Based on the data obtained from the laser scanner (D-700; 3Shape A/S, Copenhagen, Denmark), a total of 20 zirconia frameworks were prepared using a dental CAD/CAM system (DentalDesigner; 3shape A/S, Copenhagen, Denmark / Ener-mill, Dentaim, Seoul, Korea). The silicone replicas were sectioned into four pieces to evaluate the framework fit. The replicas were imaged using a digital microscope, and the fit of the reference points (P1, P2, P3, P4, P5, P6, and P7) were measured using the program in the device. Measured discrepancies were divided into 5 categories of gaps (MG, CG, AWG, AOTG, OG). Data were analyzed with Student's t-test ($\alpha$=0.05), repeated measures ANOVA and two-way ANOVA (${\alpha}=0.05$). RESULTS. The mean gap of the zirconia framework prepared from the working models presented a narrower discrepancy than the frameworks fabricated from the impression bodies. The mean of the total gap in premolars (P=.003) and molars (P=.002) exhibited a statistical difference between two groups. CONCLUSION. The mean gap dimensions of each category showed statistically significant difference. Nonetheless, the digitized impression bodies obtained with a laser scanner were applicable to clinical settings, considering the clinically acceptable marginal fit ($120{\mu}m$).

Clinical Characteristics and Ultrasonographic Findings of Acute Bacterial Enterocolitis in Children

  • Chun, Peter;Lim, Taek Jin;Hwang, Eun Ha;Mun, Sang Wook;Lee, Yeoun Joo;Park, Jae Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제20권2호
    • /
    • pp.107-113
    • /
    • 2017
  • Purpose: This study clarified the bacterial pathogens currently causing acute infectious enterocolitis (AIE) in children and evaluated the clinical characteristics and ultrasonographic findings according to the different pathogens. Methods: Medical records regarding age, sex, clinical symptoms, laboratory data, identified enteropathogens, ultrasonographic findings, treatment, and outcome of 34 patients who were diagnosed with AIE via stool examination using multiplex polymerase chain reaction (PCR) or culture, were retrospectively reviewed. Results: Twenty-four patients (70.6%) were male. The mean age of the patients was $8.5{\pm}6.2$ (range, 1.1-17.1) years. Six bacterial pathogens were isolated: Salmonella species (spp.) (32.4%), Campylobacter spp. (20.6%), verotoxin-producing Escherichia coli (14.7%), Staphylococcus aureus (11.8%), Clostridium difficile (8.8%), and Shigella spp. (2.9%). Abdominal pain occurred in all patients regardless of pathogen. The patients infected with Salmonella were older than those infected with verotoxin-producing E. coli (p<0.05). C-reactive protein levels were higher in patients with Salmonella and Campylobacter infections than in those with verotoxin-producing E. coli infection (p< 0.05), the other clinical and laboratory data were indistinguishable between pathogens. Ultrasonography demonstrated diverse involvement of bowel segments according to pathogen. Wall thickening of both the ileum and the entire colon was the most common lesion site regardless of pathogen. Conclusion: Various bacterial agents cause AIE and the symptoms are diverse symptoms, however, all most children recovered spontaneously. Use of multiplex PCR on stool samples warrants improvement of its sensitivity for diagnosis of enteropathogenic bacteria. Ultrasonographic examination is useful for diagnosis of AIE; it can also detect the disease extent and severity.

내·외적인 자극을 받는 뇌파의 비선형 동력학적 특징 (Nonlinear Characterization of EEG Under the Internal and External Stimuli)

  • 정기영;김재문;유철승;이상훈
    • Annals of Clinical Neurophysiology
    • /
    • 제4권1호
    • /
    • pp.28-33
    • /
    • 2002
  • Backgrounds and objective : EEG reflect dynamic changes of continuous neuronal activities by internal and external stimuli. The aim of this study is to quantify nonlinearly the local dynamic differences among EEG data corresponding to different states of brain. Methods : EEG was recorded from twelve healthy normal subjects(mean age, 29.7 years; 8 men and 4 women) using digital EEG machine. 18-channel EEG data were selected during eyes closed(EC), eyes open(EO), and mental arithmetic(MA) in each subject. Correlation dimension(D2) and largest Lyapunov exponent(LLE) were calculated from three states and average value was mapped 2 dimensionally and compared with each other. Results : The distribution of D2 was relatively symmetric and its value was higher in frontal than in parieto-occipital region during EC. These findings were reversed during EO. Bilateral centro-temporo-parietal region showed high D2 value in MA compared with those in EC, which was more prominent in left side. LLE was larger than zero in all state and showed significant differences among EC, EO and MA(p=0.000). Conclusion : These results suggest that nonlinear analysis of EEG can quantify dynamic state of brain.

  • PDF

Expression of Poly (ADP-ribose) Polymerase During Apoptosis Induced by Ultraviolet Radiation in HeLa $S_3$ Cells

  • Chang, Jeong-Hyun;Kwon, Heun-Young
    • 대한의생명과학회지
    • /
    • 제12권4호
    • /
    • pp.349-354
    • /
    • 2006
  • Induction of apoptosis allows the organism to get rid of abnormal cells and also of tumor cells. Understanding the mechanism involved in Ultraviolet radiation (UV) induced apoptosis may improve its therapeutic efficacy. In this study, we present expression of poly (ADP-ribose) polymerase (PARP) during apoptosis induced by UV in HeLa $S_3$ cells. Four different assays were performed in this study: morphological assessment of apoptotic cells and cell viability, DNA fragmentation analysis by agarose gel electrophoresis, quantitative assay of fragmented DNA, and expression of PARP by the western blot analysis. The percentages of apoptotic HeLa $S_3$ cells irradiated with $75J/m^2$ UV was increased continuously from 3 hrs incubation. DNA ladder pattern was appeared at 6 hrs. The amount of nucleosomal DNA fragments in cells treated UV increased from 3 to 12 hrs incubation and gradually decreased. The cleavage of PARP in HeLa $S_3$ cells irradiated with UV was induced, and the cleavage of PARP was more delayed in the cells pretreated with $5J/m^2$ UV and subsequently irradiated with $75J/m^2$ UV. than that in the cells only irradiated with $75J/m^2$ UV. Thus these data suggest that the cleavage of PARP relates with DNA fragmentation associated with apoptosis.

  • PDF

자동화학 분석기 Toshiba 120 FR의 평가 (Evaluation of Autochemical Analyzer Toshiba 120 FR)

  • 박점기
    • 대한임상검사과학회지
    • /
    • 제36권2호
    • /
    • pp.98-109
    • /
    • 2004
  • The lower limit of detection, precision, setting method of target value, reportable range determination, recovery, linearity, and comparison study with another equipment was evaluated for the Toshiba-120FR chemistry autoanalyzer which was newly introduced at the Daejeon Veteran Hospital in Dec. 2003. Nineteen kinds of test for AST, ALT, ALP, LDH, GGT, TP, ALB, GLU, T-cho, T-bil, TG, UA, CAL, IP, AMY, HDL-C, LDL-C, Cre and BUN were performed to evaluate the lower limit of detection, precision, setting method of target value, reportable range determination, recovery, linearity, and comparison study with other equipment according to the NCCLS guidelines(EP5-A, EP6-P, EP9-A). The Toshiba-120FR autochemical analyzer showed good precision for all tested items. The data concerning the lower limit of detection, precision(total CV 0.47%~3.65%), setting method of target value, reportable range determination, recovery(93%~111%), linearity($R^2=0.997{\sim}0.999$), and comparison study(r=0.977~0.999) with other equipment was acceptable for all tested items. The results of evaluation for the Toshiba-120FR autochemical analyzer showed that this equipment could be used as an alternative to other equipment.

  • PDF