• 제목/요약/키워드: Clinical Integration

검색결과 336건 처리시간 0.027초

Effect of cell-penetrating peptide-conjugated estrogen-related receptor ${\beta}$ on the development of mouse embryos cultured in vitro

  • Yang, Ning Jie;Seol, Dong-Won;Jo, Junghyun;Jang, Hyun Mee;Yoon, Sook-Young;Lee, Dong Ryul
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제41권1호
    • /
    • pp.1-8
    • /
    • 2014
  • Objective: Estrogen related receptor ${\beta}$ (Esrrb) is a member of the orphan nuclear receptors and may regulate the expression of pluripotencyrelated genes, such as Oct4 and Nanog. Therefore, in the present study, we have developed a method for delivering exogenous ESRRB recombinant protein into embryos by using cell-penetrating peptide (CPP) conjugation and have analyzed their effect on embryonic development. Methods: Mouse oocytes and embryos were obtained from superovulated mice. The expression of Oct4 mRNA and the cell number of inner cell mass (ICM) in the in vitro-derived and in vivo-derived blastocysts were first analyzed by real time-reverse transcription-polymerase chain reaction and differential staining. Then 8-cell embryos were cultured in KSOM media with or without $2{\mu}g/mL$ CPP-ESRRB protein for 24 to 48 hours, followed by checking their integration into embryos during in vitro culture by Western blot and immunocytochemistry. Results: Expression of Oct4 and the cell number of ICM were lower in the in vitro-derived blastocysts than in the in vivo-derived ones (p<0.05). In the blastocysts derived from the CPP-ESRRB-treated group, expression of Oct4 was greater than in the non-treated groups (p<0.05). Although no difference in embryonic development was observed between the treated and non-treated groups, the cell number of ICM was greater in the CPP-ESRRB-treated group. Conclusion: Treatment of CPP-ESRRB during cultivation could increase embryos' expression of Oct4 and the formation rate of the ICM in the blastocyst. Additionally, an exogenous delivery system of CPP-conjugated protein would be a useful tool for improving embryo culture systems.

119와 1339에 접수되는 중독 상담 정보의 변화 비교: 응급의료정보센터(1339) 통합 이후의 소방구급상황센터(119)에서의 병원 전 독성 물질 노출자료 현황 분석 (Changes of Poison Data Characteristics Collected from Telephone Response in 1339 and 119: Discrepancy in Characteristics of Post-toxin Exposure Data Obtained through Telephone Counselling Provided by 1339 and 119)

  • 박광훈;박종수;이성우;김수진;한갑수;이의중
    • 대한임상독성학회지
    • /
    • 제15권2호
    • /
    • pp.116-121
    • /
    • 2017
  • Purpose: The aim of this study was to compare the toxicologic profiles and outcome of poisoned patients by comparing the data obtained through telephone counselling, each provided by emergency medical information center (1339) and emergency dispatch center (119). Methods: We analyzed the telephone-based poison exposure data before and after Seoul 1339 merged to 119. We compared the Seoul 1339 call response data in 2008 with Seoul and Busan 119 call response data between 2014 and 2016. We analyzed the changes in the trend and quality of data obtained, as well as the quality of service provided by each center before and after this reallocation, by comparing the data each obtained through telephone counselling. Results: The data was collected for a total of 2260 toxin exposure related calls made to Seoul 1339 in 2009, and 1657 calls to 119 in Seoul and Busan between 2014 and 2016. Significant difference was observed for age, sex, and reason for exposure to toxic substance between the two groups. Conclusion: After the integration of 1339 with 119, 119 focused on role of field dispatch and hospital transfer, lacking the consulting on drug poisoning. Moreover, data on exposure to toxic substances at the pre-hospital stage indicate that drug information and counseling are missing or unknown. In addition, first aid or follow-up instructions are not provided. Thus, systematic approach and management are required.

CDMA-Based Ubiquitous $SaO_2$ Monitoring System for Oxygen Therapy Patients

  • Lee, Seung-Yup;Kang, Jae-Min;Shin, Il-Hyeung;Lee, Jae-Ho;Lee, Choon-Taek;Kim, Hee-Chan
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권5호
    • /
    • pp.274-281
    • /
    • 2006
  • In this paper, we propose a ubiquitous $SaO_2$ monitoring system for patients using oxygen therapy. For these patients, the ability to monitor oxygen saturation ubiquitously is very important fur accurate adjustment of ventilator's flow rate to match the patient's time-varying requirements with the shortest lag time possible. We have developed a portable device to measure $SaO_2$ and transmit it to hospital in real-time or in store-and-forward mode through the integration of $Bluetooth^{TM}$ technology and the code division multiple access (CDMA) cellular network. We also developed software for doctors to receive and manage the patients' $SaO_2$ information. Performance of the developed system was evaluated as acceptable by assessing the accuracy of the measured oxygen saturation value and the stability of communication network. Test results in real clinical setting demonstrate that our system is feasible for immediate use in home oxygen therapy.

Evaluation of Osseointegration around Tibial Implants in Rats by Ibandronate-Treated Nanotubular Ti-32Nb-5Zr Alloy

  • Nepal, Manoj;Li, Liang;Bae, Tae Sung;Kim, Byung Il;Soh, Yunjo
    • Biomolecules & Therapeutics
    • /
    • 제22권6호
    • /
    • pp.563-569
    • /
    • 2014
  • Materials with differing surfaces have been developed for clinical implant therapy in dentistry and orthopedics. This study was designed to evaluate bone response to titanium alloy containing Ti-32Nb-5Zr with nanostructure, anodic oxidation, heat treatment, and ibandronate coating. Rats were randomly assigned to two groups for implantation of titanium alloy (untreated) as the control group and titanium alloy group coated with ibandronate as the experimental group. Then, the implants were inserted in both tibiae of the rats for four weeks. After implantation, bone implant interface, trabecular microstructure, mechanical fixation was evaluated by histology, micro-computed tomography (${\mu}CT$) and the push-out test, respectively. We found that the anodized, heat-treated and ibandronate-coated titanium alloy triggered pronounced bone implant integration and early bone formation. Ibandronate-coated implants showed elevated values for removal torque and a higher level of BV/TV, trabecular thickness and separation upon analysis with ${\mu}CT$ and mechanical testing. Similarly, higher bone contact and a larger percentage bone area were observed via histology compared to untreated alloy. Furthermore, well coating of ibandronate with alloy was observed by vitro releasing experiment. Our study provided evidences that the coating of bisphosphonate onto the anodized and heat-treated nanostructure of titanium alloy had a positive effect on implant fixation.

Improved Biocompatibility of Intra-Arterial Poly-L-Lactic Acid Stent by Tantalum Ion Implantation : 3-Month Results in a Swine Model

  • Kim, Kangmin;Park, Suhyung;Park, Jeong Hwan;Cho, Won-Sang;Kim, Hyoun-Ee;Lee, Sung-Mi;Kim, Jeong Eun;Kang, Hyun-Seung;Jang, Tae-Sik
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권6호
    • /
    • pp.853-863
    • /
    • 2021
  • Objective : Biodegradable poly-L-lactic acid (PLLA) with a highly biocompatible surface via tantalum (Ta) ion implantation can be an innovative solution for the problems associated with current biodegradable stents. The purpose of this study is to develop a Taimplanted PLLA stent for clinical use and to investigate its biological performance capabilities. Methods : A series of in vitro and in vivo tests were used to assess the biological performance of bare and Ta-implanted PLLA stents. The re-endothelialization ability and thrombogenicity were examined through in vitro endothelial cell and platelet adhesion tests. An in vivo swine model was used to evaluate the effects of Ta ion implantation on subacute restenosis and thrombosis. Angiographic and histologic evaluations were conducted at one, two and three months post-treatment. Results : The Ta-implanted PLLA stent was successfully fabricated, exhibiting a smooth surface morphology and modified layer integration. After Ta ion implantation, the surface properties were more favorable for rapid endothelialization and for less platelet attachment compared to the bare PLLA stent. In an in vivo animal test, follow-up angiography showed no evidence of in-stent stenosis in either group. In a microscopic histologic examination, luminal thrombus formation was significantly suppressed in the Ta-implanted PLLA stent group according to the 2-month follow-up assessment (21.2% vs. 63.9%, p=0.005). Cells positive for CD 68, a marker for the monocyte lineage, were less frequently identified around the Ta-implanted PLLA stent in the 1-month follow-up assessments. Conclusion : The use of a Ta-implanted PLLA stent appears to promote re-endothelialization and anti-thrombogenicity.

Design of a Hospice Referral System for Terminally Ill Cancer Patients Using a Standards-Based Health Information Exchange System

  • Lim, Kahyun;Kim, Jeong-Whun;Yoo, Sooyoung;Heo, Eunyoung;Ji, Hyerim;Kang, Beodeul
    • Healthcare Informatics Research
    • /
    • 제24권4호
    • /
    • pp.317-326
    • /
    • 2018
  • Objectives: The demand for hospice has been increasing among patients with cancer. This study examined the current hospice referral scenario for terminally ill cancer patients and created a data form to collect hospice information and a modified health information exchange (HIE) form for a more efficient referral system for terminally ill cancer patients. Methods: Surveys were conducted asking detailed information such as medical instruments and patient admission policies of hospices, and interviews were held to examine the current referral flow and any additional requirements. A task force team was organized to analyze the results of the interviews and surveys. Results: Six hospices completed the survey, and 3 physicians, 2 nurses, and 2 hospital staff from a tertiary hospital were interviewed. Seven categories were defined as essential for establishing hospice data. Ten categories and 40 data items were newly suggested for the existing HIE document form. An implementation guide for the Consolidated Clinical Document Architecture developed by Health Level 7 (HL7 CCDA) was also proposed. It is an international standard for interoperability that provides a framework for the exchange, integration, sharing, and retrieval of electronic health information. Based on these changes, a hospice referral scenario for terminally ill cancer patients was designed. Conclusions: Our findings show potential improvements that can be made to the current hospice referral system for terminally ill cancer patients. To make the referral system useful in practice, governmental efforts and investments are needed.

노인복지분야의 통합적 케어와 사회복지사의 역할 (Integrated Care Setting for the Elderly and the Roles of Social Workers)

  • 윤경아
    • 한국콘텐츠학회논문지
    • /
    • 제19권3호
    • /
    • pp.441-456
    • /
    • 2019
  • 본 연구의 목적은 노인대상 통합적 케어 프로그램의 구성 요소와 효과를 탐색하고, 이러한 프로그램에서 다학제팀의 일원으로 활동하는 사회복지사의 역할을 기술하는 것이다. 연구를 위해 신속 체계적 문헌고찰을 실시하였으며, 데이터베이스 검색과 수기 검색을 단계적으로 진행하였다. 주요 연구결과는 다음과 같다. 첫째, 노인대상 통합적 케어 프로그램의 주요 요소는 케이스매니지먼트, 개별케에플랜, 서비스 특성, 클라이언트 욕구중심, 환자교육, 자기관리로 나타났다. 둘째, 참여노인의 케어경험과 건강 및 경제적 측면에서, 결과가 혼합되어 있긴 하지만, 대조군에 비해 프로그램 참여노인에게 어느 정도 긍정적인 효과가 나타났다. 셋째, 통합적 케어 프로그램의 다학제팀에서 사회복지사는 케이스매니저, 케어매니저, 케어코디네이터, 그리고 직접 서비스 제공자의 역할을 수행하고 있는 것으로 나타났다. 연구결과를 바탕으로 노인대상 통합적 케어를 준비하기 위해 필요한 교육과 정책에 대한 제언을 하였다.

의과대학생을 위한 환자안전 교육의 국제적 동향 및 국내 현황 (Patient Safety Education for Medical Students: Global Trends and Korea's Status)

  • 노혜린
    • 의학교육논단
    • /
    • 제21권1호
    • /
    • pp.1-12
    • /
    • 2019
  • This study is a narrative review introducing global trends in patient safety education within medical schools and exploring the status of Korean education. Core competences for patient safety include patient centeredness, teamwork, evidence- and information-based practice, quality improvement, addressing medical errors, managing human factors and system complexity, and patient safety knowledge and responsibility. According to a Korean report addressing the role of doctors, patient safety was described as a subcategory of clinical care. Doctors' roles in patient safety included taking precautions, educating patients about the side effects of drugs, and implementing rapid treatment and appropriate follow-up when patient safety is compromised. The Korean Association of Medical Colleges suggested patient safety competence as one of eight essential human and society-centered learning outcomes. They included appropriate attitude and knowledge, human factors, a systematic approach, teamwork skills, engaging with patients and carers, and dealing with common errors. Four Korean medical schools reported integration of a patient safety course in their preclinical curriculum. Studies have shown that students experience difficulty in reporting medical errors because of hierarchical culture. It seems that patient safety is considered in a narrow sense and its education is limited in Korea. Patient safety is not a topic for dealing with only adverse events, but a science to prevent and detect early system failure. Patient safety emphasizes patient perspectives, so it has a different paradigm of medical ethics and professionalism, which have doctor-centered perspectives. Medical educators in Korea should understand patient safety concepts to implement patient safety curriculum. Further research should be done on communication in hierarchical culture and patient safety education during clerkship.

A comparative study between sterile freeze-dried and sterile pre-hydrated acellular dermal matrix in tissue expander/implant breast reconstruction

  • Cheon, Jeong Hyun;Yoon, Eul Sik;Kim, Jin Woo;Park, Seung Ha;Lee, Byung Il
    • Archives of Plastic Surgery
    • /
    • 제46권3호
    • /
    • pp.204-213
    • /
    • 2019
  • Background In implant-based breast reconstruction, acellular dermal matrix (ADM) is essential for supporting the inferolateral pole. Recent studies have compared non-sterilized freeze-dried ADM and sterilized pre-hydrated ADM, but have not assessed whether differences were attributable to factors related to sterile processing or packaging. This study was conducted to compare the clinical outcomes of breast reconstruction using two types of sterile-processed ADMs. Methods Through a retrospective chart review, we analyzed 77 consecutive patients (85 breasts) who underwent tissue expander/implant breast reconstruction with either freeze-dried ADM (35 breasts) or pre-hydrated ADM (50 breasts) from March 2016 to February 2018. Demographic variables, postoperative outcomes, and operative parameters were compared between freeze-dried and pre-hydrated ADM. Biopsy specimens were obtained for histologic analysis. Results We obtained results after adjusting for variables found to be significant in univariate analyses. The total complication rate for freeze-dried and pre-hydrated ADMs was 25.7% and 22.0%, respectively. Skin necrosis was significantly more frequent in the freeze-dried group than in the pre-hydrated group (8.6% vs. 4.0%, P=0.038). All other complications and operative parameters showed no significant differences. In the histologic analysis, collagen density, inflammation, and vascularity were higher in the pre-hydrated ADM group (P=0.042, P=0.006, P=0.005, respectively). Conclusions There are limited data comparing the outcomes of tissue expander/implant breast reconstruction using two types of sterile-processed ADMs. In this study, we found that using pre-hydrated ADM resulted in less skin necrosis and better integration into host tissue. Pre-hydrated ADM may therefore be preferable to freeze-dried ADM in terms of convenience and safety.

Validity of Three-dimensional Facial Scan Taken with Facial Scanner and Digital Photo Wrapping on the Cone-beam Computed Tomography: Comparison of Soft Tissue Parameters

  • Aljawad, Hussein;Lee, Kyungmin Clara
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.19-30
    • /
    • 2022
  • Purpose: The purpose of the study was to assess the validity of three-dimensional (3D) facial scan taken with facial scanner and digital photo wrapping on the cone-beam computed tomography (CBCT). Materials and Methods: Twenty-five patients had their CBCT scan, two-dimensional (2D) standardized frontal photographs and 3D facial scan obtained on the same day. The facial scans were taken with a facial scanner in an upright position. The 2D standardized frontal photographs were taken at a fixed distance from patients using a camera fixed to a cephalometric apparatus. The 2D integrated facial models were created using digital photo wrapping of frontal photographs on the corresponding CBCT images. The 3D integrated facial models were created using the integration process of 3D facial scans on the CBCT images. On the integrated facial models, sixteen soft tissue landmarks were identified, and the vertical, horizontal, oblique and angular distances between soft tissue landmarks were compared among the 2D facial models and 3D facial models, and CBCT images. Result: The results showed no significant differences of linear and angular measurements among CBCT images, 2D and 3D facial models except for Se-Sn vertical linear measurement which showed significant difference for the 3D facial models. The Bland-Altman plots showed that all measurements were within the limit of agreement. For 3D facial model, all Bland-Altman plots showed that systematic bias was less than 2.0 mm and 2.0° except for Se-Sn linear vertical measurement. For 2D facial model, the Bland-Altman plots of 6 out of 11 of the angular measurements showed systematic bias of more than 2.0°. Conclusion: The facial scan taken with facial scanner showed a clinically acceptable performance. The digital 2D photo wrapping has limitations in clinical use compared to 3D facial scans.