• Title/Summary/Keyword: Clinical CT

Search Result 1,843, Processing Time 0.167 seconds

Interstitial Lung Abnormalities: What Radiologists Should Know

  • Kum Ju Chae;Gong Yong Jin;Jin Mo Goo;Myoung Ja Chung
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.454-463
    • /
    • 2021
  • Interstitial lung abnormalities (ILAs) are radiologic abnormalities found incidentally on chest CT that are potentially related to interstitial lung diseases. Several articles have reported that ILAs are associated with increased mortality, and they can show radiologic progression. With the increased recognition of ILAs on CT, the role of radiologists in reporting them is critical. This review aims to discuss the clinical significance and radiologic characteristics of ILAs to facilitate and enhance their management.

Utility of Computed Tomography in a Differential Diagnosis for the Patients with an Initial Diagnosis of Chronic Obstructive Pulmonary Disease Exacerbation

  • Park, Hyung Jun;Kim, Soo Han;Kim, Ho-Cheol;Lee, Bo Young;Lee, Sei Won;Lee, Jae Seung;Lee, Sang-Do;Seo, Joon Beom;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.82 no.3
    • /
    • pp.234-241
    • /
    • 2019
  • Background: The utility of computed tomography (CT) in the differential diagnosis of patients with chronic obstructive pulmonary disease (COPD) exacerbation remains uncertain. However, due to the low cost associated with CT scan along with the impact of Koreas' health insurance system, there has been a rise in the number of CT scans in the patients with initial diagnosis of COPD exacerbations. Therefore, the utility of CT in the differential diagnosis was investigated to determine whether performing CT scans affect the clinical outcomes of the patients with an initial diagnosis of COPD exacerbation. Methods: This study involved 202 COPD patients hospitalized with an initial diagnosis of COPD exacerbation. We evaluated the change in diagnosis or treatment after performing a CT scan, and compared the clinical outcomes of patient groups with vs. without performing CT (non-CT group vs. CT group). Results: After performing CT, the diagnosis was changed for two (3.0%) while additional diagnoses were made for 27 of the 64 patients (42.1%). However, the treatment changed for only one (1.5%), and six patients (9.3%) received supplementary medication. There were no difference in the median length of hospital stay (8 [6-13] days vs. 8 [6-12] days, p=0.786) and intensive care unit care (14 [10.1%] vs. 11 [16.7%], p=0.236) between the CT and non-CT groups, respectively. These findings remained consistent even after the propensity score matching. Conclusion: Utility of CT in patients with acute COPD exacerbation might not be helpful; therefore, we do not recommend chest CT scan as a routine initial diagnostic tool.

C1420T Polymorphism of Cytosolic Serine Hydroxymethyltransferase and Risk of Cancer: a Meta-analysis

  • Zhong, Shan-Liang;Zhang, Jun;Hu, Qing;Chen, Wei-Xian;Ma, Teng-Fei;Zhao, Jian-Hua
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.5
    • /
    • pp.2257-2262
    • /
    • 2014
  • A series of studies have explored the role of cytosolic serine hydroxymethyltransferase (SHMT1) C1420T polymorphism in cancer risk, but their results were conflicting rather than conclusive. To derive a more precise estimation of the association between C1420T and cancer risk, the present meta-analysis of 28 available studies with 15,121 cases and 18,023 controls was conducted. The results revealed that there was no significant association between the polymorphism and cancer risk overall. In stratified analysis by cancer type (breast cancer, gastrointestinal cancer, leukemia, lymphoma, and others), the results showed that 1420T allele was associated with decreased risk in leukemia (CT vs. CC: OR= 0.825, 95% CI =0.704-0.966; and CT+TT vs. CC: OR= 0.838, 95% CI = 0.722-0.973), but the same results were not present for other cancer types. When subgroup analysis was performed by source of control (population-based [PB] and hospital-based [HB]), a borderline inverse association was observed for the HB subgroup (CT vs. CC: OR= 0.917, 95% CI = 0.857-0.982) but not for the PB subgroup. Stratifying by geographic area (America, Asia and Europe), significant inverse association was only found in Asia subgroup (CT vs. CC: OR= 0.674, 95% CI = 0.522-0.870). In summary, the findings suggest that SHMT1 C1420T polymorphism is not associated with overall cancer development, but might decrease cancer susceptibility of Asians as well as reduce leukemia risk. Large well-designed epidemiological studies will be necessary to validate the risk identified in the current meta-analysis.

Spect Assessment of Regional Cerebral Perfusion Abnormality in Head Injury (두부외상 환자에서 HMPAO-SPECT를 이용한 국소 뇌혈류 변화의 평가)

  • Lee, Kyung-Han;Kim, Chul-Hee;Chang, Ha-Sung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.235-243
    • /
    • 1992
  • Patterns of abnormality in regional cerebral perfusion and its relation to clinical severity was evaluated with 32 head injury patients using $^{99m}Tc-HMPAO$ single photon emission tomography (SPECT). The findings were compared with computed tomography (CT) done within 48 hours of each SPECT study. The initial SPECT study was done within 7 days of injury in 16 cases, between 1 week and 2 months in 12, and after over 2 months in 4. Nineteen of the patients underwent followup SPECT and CT after a mean interval of 1 to 2 months. The initial SPECT showed abnormalities in 96% (31/32) of the patients while CT showed abnormal findings in only 81% (26/32). There were a total of 54 supratentorial SPECT lesions in all. Ninity percent (49/54) of these were of regional hypoperfusion, while 5 lesions showed focal hyperperfusion. The lesions were most often localized in the frontal and temporal lobes. Fifty five percent (30/54) were areas not detected as a lesion on CT. Cerebellar diaschisis was observed in 50% (16/32) of the patients. The degree of perfusion abnormality was quantified by the product of differential activity and a size factor. Correlation between the degree of perfusion abnormality and the clinical severity (Glasgow coma scale) failed to show statistical significance (p=0.053). The amount of change in the degree of perfusion abnormality on follow up SPECT was compared to the amount of change in clinical severity. Perfusion abnormality showed a tendancy to improve in most patients, and the degree of improvement showed significant correlation with the amount of clinical improvement (p < 0.01).

  • PDF

Studies and Real-World Experience Regarding the Clinical Application of Artificial Intelligence Software for Lung Nodule Detection (폐결절 검출 인공지능 소프트웨어의 임상적 활용에 관한 연구와 실제 사용 경험)

  • Junghoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.4
    • /
    • pp.705-713
    • /
    • 2024
  • This article discusses studies and real-world experiences related to the clinical application of artificial intelligence-based computer-aided detection (AI-CAD) software (LuCAS-plus, Monitor Corporation) in detecting pulmonary nodules. During clinical trials for lung cancer screening, AI-CAD exhibited performance comparable to that of medical professionals in terms of sensitivity and specificity. Studies revealed that applying AI-CAD for diagnosing pulmonary metastases led to high detection rates. The use of a nodule matching algorithm in diagnosing pulmonary metastases significantly reduced false non-metastasis results. In clinical settings, implementing AI-CAD enhanced the efficiency of pulmonary nodule detection, saving time and effort during CT reading. Overall, AI-CAD is expected to offer substantial support for lung cancer screening and the interpretation of chest CT scans for malignant tumor surveillance.

Quantitative CT Analysis Based on Smoking Habits and Chronic Obstructive Pulmonary Disease in Patients with Normal Chest CT (정상 흉부 단층촬영 검사에서 흡연 및 폐쇄성 폐질환 유무에 따른 정량화 검사 분석)

  • Jung Hee Byon;Gong Yong Jin;Young Min Han;Eun Jung Choi;Kum Ju Chae;Eun Hae Park
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.900-910
    • /
    • 2023
  • Purpose To assess normal CT scans with quantitative CT (QCT) analysis based on smoking habits and chronic obstructive pulmonary disease (COPD). Materials and Methods From January 2013 to December 2014, 90 male patients with normal chest CT and quantification analysis results were enrolled in our study [non-COPD never-smokers (n = 38) and smokers (n = 45), COPD smokers (n = 7)]. In addition, an age-matched cohort study was performed for seven smokers with COPD. The square root of the wall area of a hypothetical bronchus of internal perimeter 10 mm (Pi10), skewness, kurtosis, mean lung attenuation (MLA), and percentage of low attenuation area (%LAA) were evaluated. Results Among patients without COPD, the Pi10 of smokers (4.176 ± 0.282) was about 0.1 mm thicker than that of never-smokers (4.070 ± 0.191, p = 0.047), and skewness and kurtosis of smokers (2.628 ± 0.484 and 6.448 ± 3.427) were lower than never-smokers (2.884 ± 0.624, p = 0.038 and 8.594 ± 4.944, p = 0.02). The Pi10 of COPD smokers (4.429 ± 0.435, n = 7) was about 0.4 mm thicker than never-smokers without COPD (3.996 ± 0.115, n = 14, p = 0.005). There were no significant differences in MLA and %LAA between groups (p > 0.05). Conclusion Even on normal CT scans, QCT showed that the airway walls of smokers are thicker than never-smokers regardless of COPD and it preceded lung parenchymal changes.

Clinical Utility of CT-Based Bronchial Aspirate TB-PCR for the Rapid Diagnosis of Pleural Tuberculosis

  • Lee, Jaehee;Lee, So Yeon;Choi, Keum Ju;Lim, Jae Kwang;Yoo, Seung Soo;Lee, Shin Yup;Cha, Seung Ick;Park, Jae Yong;Kim, Chang Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.75 no.4
    • /
    • pp.150-156
    • /
    • 2013
  • Background: Thoracoscopic pleural biopsy is often required for rapid and confirmative diagnosis in patients with suspected pleural tuberculosis (PL-TB). However, this method is more invasive and costly than its alternatives. Therefore, we evaluated the clinical utility of the chest computed tomography (CT)-based bronchial aspirate (BA) TB-polymerase chain reaction (PCR) test in such patients. Methods: Bronchoscopic evaluation was performed in 54 patients with presumptive PL-TB through diagnostic thoracentesis but without a positive result of sputum acid-fast bacilli (AFB) smear, pleural fluid AFB smear, or pleural fluid TB-PCR test. Diagnostic yields of BA were evaluated according to the characteristics of parenchymal lesions on chest CT. Results: Chest radiograph and CT revealed parenchymal lesions in 25 (46%) and 40 (74%) of 54 patients, respectively. In cases with an absence of parenchymal lesions on chest CT, the bronchoscopic approach had no diagnostic benefit. BA TB-PCR test was positive in 21 out of 22 (95%) patients with early-positive results. Among BA results from 20 (37%) patients with patchy consolidative CT findings, eight (40%) were AFB smear-positive, 18 (90%) were TB-PCR-positive, and 19 (95%) were culture-positive. Conclusion: The BA TB-PCR test seems to be a satisfactory diagnostic modality in patients with suspected PL-TB and patchy consolidative CT findings. For rapid and confirmative diagnosis in these patients, the bronchoscopic approach with TB-PCR may be preferable to the thoracoscopy.

Clinical Feasibility of CT Brain Perfusion in a Dog with Sellar Region Tumor

  • Minji Kim;Gunha Hwang;Jeongmin Ryu;Jiwon Yoon;Moon Yeong Choi;Joong-Hyun Song;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.178-182
    • /
    • 2024
  • A 10-year-old spayed female Poodle was referred for blindness. On ophthalmic examination, loss of bilateral ocular pupil light reflex, visual loss, and right retinal detachment were confirmed at a local hospital. Magnetic resonance imaging (MRI) of the brain was performed to identify the optic nerve, optic chiasm, and brain disease. A sessile mass centered on the region of the optic chiasm was identified. The mass had iso- to hypointense on fluid-attenuated inversion recovery and T2-weighted images and mildly hypointense on T1-weighted images compared to the gray matter, with strong contrast enhancement. Peripheral edema was also identified. Computed tomography (CT) brain perfusion was performed to obtain additional hemodynamic information about the patient using a multislice CT. CT perfusion showed that the cerebral blood volume in the left temporal lobe region (13.4 ± 1.6 mL/100 g) was decreased relative to the contralateral region (19.9 ± 0.3 mL/100 g). The patient showed decreased appetite and consciousness one week after the CT scan with clinical symptoms worsened. The patient had seizure, tetraparesis, and loss of consciousness. It was euthanized one month later at the request of the owner. This report suggests that CT brain perfusion can provide additional hemodynamic information such as insufficient brain perfusion in sellar region tumor which can help assess potential complications and prognosis and plan treatment.

Clinical Applications of Dual-Energy CT

  • Saira Hamid;Muhammad Umer Nasir;Aaron So;Gordon Andrews;Savvas Nicolaou;Sadia Raheez Qamar
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.970-982
    • /
    • 2021
  • Dual-energy CT (DECT) provides insights into the material properties of tissues and can differentiate between tissues with similar attenuation on conventional single-energy imaging. In the conventional CT scanner, differences in the X-ray attenuation between adjacent structures are dependent on the atomic number of the materials involved, whereas in DECT, the difference in the attenuation is dependent on both the atomic number and electron density. The basic principle of DECT is to obtain two datasets with different X-ray energy levels from the same anatomic region and material decomposition based on attenuation differences at different energy levels. In this article, we discuss the clinical applications of DECT and its potential robust improvements in performance and postprocessing capabilities.

A Study on Usefulness of Clinical Application of Metal Artifact Reduction Algorithm in Radiotherapy (방사선치료 시 Metal artifact reduction Algorithm의 임상적용 유용성평가)

  • Park, Ja Ram;Kim, Min Su;Kim, Jeong Mi;Chung, Hyeon Suk;Lee, Chung Hwan;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.9-17
    • /
    • 2017
  • Purpose: The tissue description and electron density indicated by the Computed Tomography(CT) number (also known as Hounsfield Unit) in radiotherapy are important in ensuring the accuracy of CT-based computerized radiotherapy planning. The internal metal implants, however, not only reduce the accuracy of CT number but also introduce uncertainty into tissue description, leading to development of many clinical algorithms for reducing metal artifacts. The purpose of this study was, therefore, to investigate the accuracy and the clinical applicability by analyzing date from SMART MAR (GE) used in our institution. Methode: and material: For assessment of images, the original images were obtained after forming ROIs with identical volumes by using CIRS ED phantom and inserting rods of six tissues and then non-SMART MAR and SMART MAR images were obtained and compared in terms of CT number and SD value. For determination of the difference in dose by the changes in CT number due to metal artifacts, the original images were obtained by forming PTV at two sites of CIRS ED phantom CT images with Computerized Treatment Planning (CTP system), the identical treatment plans were established for non-SMART MAR and SMART MAR images by obtaining unilateral and bilateral titanium insertion images, and mean doses, Homogeneity Index(HI), and Conformity Index(CI) for both PTVs were compared. The absorbed doses at both sites were measured by calculating the dose conversion constant (cCy/nC) from ylinder acrylic phantom, 0.125cc ionchamber, and electrometer and obtaining non-SMART MAR and SMART MAR images from images resulting from insertions of unilateral and bilateral titanium rods, and compared with point doses from CTP. Result: The results of image assessment showed that the CT number of SMART MAR images compared to those of non-SMART MAR images were more close to those of original images, and the SD decreased more in SMART compared to non-SMART ones. The results of dose determinations showed that the mean doses, HI and CI of non-SMART MAR images compared to those of SMART MAR images were more close to those of original images, however the differences did not reach statistical significance. The results of absorbed dose measurement showed that the difference between actual absorbed dose and point dose on CTP in absorbed dose were 2.69 and 3.63 % in non-SMRT MAR images, however decreased to 0.56 and 0.68 %, respectively in SMART MAR images. Conclusion: The application of SMART MAR in CT images from patients with metal implants improved quality of images, being demonstrated by improvement in accuracy of CT number and decrease in SD, therefore it is considered that this method is useful in dose calculation and forming contour between tumor and normal tissues.

  • PDF