• Title/Summary/Keyword: Climbing control system

Search Result 47, Processing Time 0.025 seconds

Mobile Healthcare System Based on Bluetooth Medical Device

  • Kim, Jeong-Heon;Lee, Seung-Chul;Lee, Boon-Giin;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.241-248
    • /
    • 2012
  • Recently healthcare industry such as pharmaceutical, medical device and healthcare service technology is growing significantly. Mobile healthcare has attracted big attention due to IT convergence technology. Paradigm of healthcare has been changed from the 1st generation(communicable disease prevention) and the 2nd generation(treatment of disease due to extended life expectancy) to the 3rd generation(extended life expectancy due to prevention and control). In our study, we suggest the 3rd generation mobile healthcare system using Bluetooth based wearable ECG monitoring system and smart phone technology. The mobile healthcare system consists of wearable shirts with Bluetooth communication module, ECG sensor, battery, and mobile phone. The ECG data is obtained by a miniaturized sensor and the data is transferred to a mobile phone using Bluetooth communication. Then, user can monitor his/her own ECG signal on an application using Android in mobile phone. The Bluetooth communication device is used due to highly reliable data transmission property and the Bluetooth chip is embedded in every mobile phone. The wearable shirts with chest belt of Bluetooth ECG module is designed with a focus on convenience in the daily life of a wearer. The ECG signal evaluation software in Android based mobile phone is developed for the health check and the ECG signal variation is tested according to the activities of the wearer such as walking, climbing stairs, stand up and sit down, and so on.

Development and Performance Evaluation of Hull Blasting Robot for Surface Pre-Preparation for Painting Process (도장전처리 작업을 위한 블라스팅 로봇 시스템 개발 및 성능평가)

  • Lee, JunHo;Jin, Taeseok
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.5
    • /
    • pp.383-389
    • /
    • 2016
  • In this paper, we present the hull blasting machine with vision-based weld bead recognition device for cleaning shipment exterior wall. The purpose of this study is to introduce the mechanism design of the high efficiency hull blasting machine using the vision system to recognize the weld bead. Therefore, we have developed a robot mechanism and drive controller system of the hull blasting robot. And hull blasting characteristics such as the climbing mechanism, vision system, remote controller and CAN have been discussed and compared with the experimental data. The hull blasting robots are able to remove rust or paint at anchor, so the re-docking is unnecessary. Therefore, this can save time and cost of undergoing re-docking process and build more vessels instead. The robot uses sensors to navigate safely around the hull and has a filter system to collect the fouling removed. We have completed a pilot test of the robot and demonstrated the drive control and CAN communication performance.

Simultaneous monitoring of motion ECG of two subjects using Bluetooth Piconet and baseline drift

  • Dave, Tejal;Pandya, Utpal
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.365-371
    • /
    • 2018
  • Uninterrupted monitoring of multiple subjects is required for mass causality events, in hospital environment or for sports by medical technicians or physicians. Movement of subjects under monitoring requires such system to be wireless, sometimes demands multiple transmitters and a receiver as a base station and monitored parameter must not be corrupted by any noise before further diagnosis. A Bluetooth Piconet network is visualized, where each subject carries a Bluetooth transmitter module that acquires vital sign continuously and relays to Bluetooth enabled device where, further signal processing is done. In this paper, a wireless network is realized to capture ECG of two subjects performing different activities like cycling, jogging, staircase climbing at 100 Hz frequency using prototyped Bluetooth module. The paper demonstrates removal of baseline drift using Fast Fourier Transform and Inverse Fast Fourier Transform and removal of high frequency noise using moving average and S-Golay algorithm. Experimental results highlight the efficacy of the proposed work to monitor any vital sign parameters of multiple subjects simultaneously. The importance of removing baseline drift before high frequency noise removal is shown using experimental results. It is possible to use Bluetooth Piconet frame work to capture ECG simultaneously for more than two subjects. For the applications where there will be larger body movement, baseline drift removal is a major concern and hence along with wireless transmission issues, baseline drift removal before high frequency noise removal is necessary for further feature extraction.

The Spatio-temporal Analysis of Gait Characteristics during Ramp Ascent and Descent at Different Inclinations (정상인의 경사로 보행 시 경사각에 따른 시공간적 보행 특성 분석)

  • Han, Jin-Tae;Cho, Jeoung-Sun;Bae, Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.1
    • /
    • pp.95-106
    • /
    • 2006
  • Purpose: The aim of this study was to investigate the kinematics of young adults during ramp climbing at different inclinations. Methods: Twenty-three subjects ascended and descended four steps at four different inclinations(level, $8^{\circ},\;16^{\circ},\;24^{\circ}$). Temporal-spatial parameters were measured by GaitRite system(standard mat). Groups difference was analysed with on-way ANOVA and Student-Newman-Keuls test. Results: The different kinematics of ramp ascent and descent were analysed and compared to level walking patterns. In ascending ramps, step length and stride length decreased with $24^{\circ}$ inclination (p<.000). Stance duration increased with $24^{\circ}$, but swing duration decreased with $24^{\circ}$ inclination (p<.000). Step time and velocity decreased with $16^{\circ}C,\;24^{\circ}$ inclination (p<.000). Cadence decreased with all inclination($8^{\circ},\;16^{\circ},\;24^{\circ}$)(p<.000). In descending ramps, step length and stride length, velocity decreased with all inclination($8^{\circ},\;16^{\circ},\;-24^{\circ}$)(p<.000). Stance duration increased with all inclination($8^{\circ},\;-16^{\circ},\;-24^{\circ}$) and swing duration decreased with all inclination($-8^{\circ},\;-16^{\circ},\;-24^{\circ}$)(p<.000). But Step time was not differentiated with different inclinations. Cadence decreased with only. $8^{\circ}$ inclination(p<.05). Conclusion: These results suggest that there is a certain inclination angle or angular range where subjects do switch between level walking and ramp walking gait pattern. This shows their motor control strategy between level and ramp walking. Further studies are necessary to confirm and detect the ascent and descent ramp gait patterns.

  • PDF

Development of PDA-Based Software for Forest Geographic Information (PDA기반의 산림지리정보 소프트웨어 개발에 관한 연구)

  • Suk, Sooil;Lee, Heonho;Lee, Dohyung
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.1
    • /
    • pp.7-13
    • /
    • 2007
  • This study was done to develop PDA based application system for forest geographic information with GPS. The major results obtained in this study were as follows. A PDA based application program was developed to work on $Microsoft^{TM}$ PocketPC 2002 and 2003 operating system. The screen of PDA displays a 1:25,000 digital topographical map adopted DXF format converted from PC, and the map data with 1:2,500 to 1:30,000 on PDA can be zoomed in or out to five levels. Current position and navigating path received from GPS can be displayed on the screen and be saved in PDA. Information selected among layers of digital topographic map in DXF format can be converted into binary files which can be used on forest geographic information software. This can compress DXF files to 90% in size, and the processing speed of PDA was improved. The forest geographic information management system can be used to manage sample plots on which forest inventory is done, with the help of the sub-menus and grid index values with position information received from GPS. Forest workers can in quire forest geographic information such as forest type, location, forest roads, soil erosion control dams using forest geographic information management system in the field. The forest geographic information management system can provide current position and mobile path information to people who enjoy forest related activities like mountain-climbing, sightseeing, and visiting to historic spots.

DEVELOPMENT OF A PERSIMMON HARVESTING SYSTEM

  • Kim, S. M.;Park, S. J.;Kim, C. S.;Kim, M. H.;Lee, C. H.;J. Y. Rhee
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.472-479
    • /
    • 2000
  • A persimmon harvesting vehicle that can be operated in hilly orchards as well as a manipulator that can be used to harvest persimmons located in remote positions in the trees were designed and developed. The vehicle could be operated with keeping balanced position in an inclined field and its working platform could be moved up and down easy to approach fruits in a remote region with the aids of a hydraulic and a electrical and electronics systems. The weight of the vehicle was 927 kg and the center of gravity was located at 427 mm to the inner side from the center of a right driving caterpillar, 607 mm to a rear axle from the center of a front axle, and 562 mm to upward from ground. The automatic level control sensor for leveling the working platform was activated within 14.5 ∼ 16.5 degrees of slope variation. The total length of the manipulator was 1.39 m and weight is 975 g. It was powered by a 12 V geared motor to detach persimmon fruits with a rotational force. The gripper was made of plastic and rubber to increase a frictional force. In a performance evaluation test, static tipping angle, dynamic tipping angle toward front side when the vehicle was moving downward, climbing angle, driving speed of the vehicle were measured or calculated. In persimmon harvesting tests 24.9% of yield was increased by hand picking with the aid of the vehicle and additional 7% of yield were increased when the manipulator was used. Therefore, 99010 of total possible yield was achievable when both of the vehicle and the manipulator were used for the manual persimmon harvesting. Increase in 22.5% of total yield was achieved with the manipulator only.

  • PDF

The 3-D Motion Analysis of Kinematic Variety on Lower Extremity during Ramp Ascent at Different Inclinations (정상인의 오름 경사로 보행 시 경사각에 따른 하지 관절의 삼차원적 동작 분석)

  • Han, Jin-Tae;Lee, Jong-Dae;Bae, Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.4
    • /
    • pp.633-650
    • /
    • 2005
  • The aim of this study was to investigate the kinematics of young adults during ascent ramp climbing at different inclinations. Twenty-three subjects ascended a four step at four different inclinations(level, $8^{\circ},\;16^{\circ},\;24^{\circ}$). The 3-D kinematics was analysed by a camera-based falcon system. Groups difference was tested with one -way ANOVA and SNK test. The different kinematic patterns of ramp ascent were analysed and compared to level walking patterns. The kinematics of ramp walking could be clearly distinguished from the kinematics of level walking. In sagittal plane, Ankle joint was more dorsiflexed at initial contact and Max. dorsiflex. during stance phase with $16^{\circ},\;24^{\circ}$ inclination and more plantarflexed at toe off and Max. plantarflex. during swing phase with $24^{\circ}$(p<.001). Knee joint was more flexed at initial contact with $16^{\circ},\;24^{\circ}$ inclination(p<.001). Hip joint was more flexed at initial contact and Max. flex. during swing phase with $16^{\circ},\;24^{\circ}$ inclination and at toe off with $24^{\circ}$(p<.001) and was more extended at Max. ext. during stance phase with $24^{\circ}$(p<.05). In frontal plane, ankle joint was more everted at Max. eversion. during stance phase with $16^{\circ},\;24^{\circ}$ inclination(p<.001). Knee joint was more increased at Max. varus. during stance phase with $16^{\circ},\;24^{\circ}$ inclination(p<.001). Hip joint was not differentiated with different inclinations. In horizontal plane, all joints were not differentiated with different inclinations. Conclusionally, In ascent ramp walking, the different gait pattern generally occurred at over $16^{\circ}$ on the ascending ramp in sagittal and frontal plane. These results suggest that there is a certain inclination angle or angular range where subjects do switch between a level walking and a ascent ramp walking gait pattern. This shows their motor control strategy between level and ascent ramp walking. Further studies are necessary to confirm and detect the ascent ramp gait patterns.

  • PDF