• Title/Summary/Keyword: Clearance Level

Search Result 210, Processing Time 0.025 seconds

Effect of Tip Clearance on the Performance of a Turbopump Inducer (끝틈새가 터보펌프 인듀서의 성능에 미치는 영향)

  • Hong, Soon-Sam;Kim, Jin-Sun;Choi, Chang-Ho;Kim, Jinhan
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.558-563
    • /
    • 2004
  • Experiments were performed to see the effect of radial tip clearance on a turbopump inducer, which has two blades with inlet tip blade angle of 7.8 degree and tip solidity of 2.7. Hydraulic and cavitation tests were done for three cases of tip clearance ratio, that is, 0.026, 0.053, and 0.079. With increase in the tip clearance, inducer head and pressure on the inducer tip decreased. Attached cavitation and cavitation surge were found in the cavitation tests. In the attached cavitation one cell rotated at the same rotational speed as that of the inducer. Cavitation performance deteriorated with increase in the tip clearance. The level of casing vibration increased in the cavitation condition and the level was very high when the attached cavitation appeared.

  • PDF

Effect of Tip Clearance on the Performance of a Turbopump Inducer (끝틈새가 터보펌프 인듀서의 성능에 미치는 영향)

  • Hong, Soon-Sam;Kim, Jin-Sun;Choi, Chang-Ho;Kim, Jin-Han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.1 s.34
    • /
    • pp.19-24
    • /
    • 2006
  • Experiments are carried out to investigate the effect of radial tip clearance on a turbopump inducer, which has two blades with inlet tip blade angle of 7.8 degree and tip solidity of 2.7. Hydraulic and cavitation tests are performed for three cases of tip clearance ratio, that is, 0.026, 0.053, and 0.079. With increase in the tip clearance, inducer head and pressure on the inducer tip decrease. Attached cavitation and cavitation surge are observed in the cavitation tests. In the attached cavitation one cell rotates at the same rotational speed as that of the inducer. Cavitation performance deteriorates with increase in the tip clearance. The level of casing vibration increases in the cavitation condition and the level is very high when the attached cavitation appears.

Variation of Operating Clearance Depending on Cooling Methods of High-Speed Roller Bearings for Aerospace Applications (항공용 고속 롤러베어링의 냉각 방식에 따른 작동간극 변화)

  • Jisu Park
    • Tribology and Lubricants
    • /
    • v.39 no.4
    • /
    • pp.123-132
    • /
    • 2023
  • In this study, the expansion, stress, and operating clearance of bearing elements during operation are observed using the inner/outer ring temperature test data of a 3.0×106 DN-class roller bearing. The operating clearance characteristics of inner-/outer-ring cooling (IORC) bearings are compared to those of inner-ring cooling (IRC) bearings. For IRC bearings, the thermal expansion of the outer ring is the most important factor in clearance variation. As a result, the operating clearance is less than the initial clearance of 61 ㎛, and the operating clearance decreases to 0.5 ㎛ at 25,500 rpm. Conversely, the temperature of the outer ring of IORC bearings is lower than that of IRC bearings, so the operating clearance is kept smaller. When the coolant flow rate to the outer ring is approximately 1.5 to 2.0 L/min, the temperature difference between the inner and outer rings is minimized and the operating clearance is maintained at a significantly lower level than IRC bearings. Small operating clearances are expected to be effective in reducing cage slip and skid damage in roller bearings. The results and analysis procedures of this study can be utilized to design of bearing clearance, lubricant flow rate, and assembled interference in the early design stage of aerospace roller bearings.

Effects of Na Restriction, K Supplement and Diuresis on Aldosterone Metabolic Clearance in the Normal Korean (한국인의 Aldosterone 대사 제거율에 미치는 Na 섭취제한, K 보충투여 및 이뇨의 영향)

  • Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.11 no.1
    • /
    • pp.37-44
    • /
    • 1977
  • In the previous study of the release, excretion, and plasma concentration of aldosterone in normal Koreans, the author found that urinary aldosterone excretion and aldosterone secretion rate of the Korean who usually take high amount of salt are significantly lower, in compared to Americans, although the plasma concentration is only tended to be low. The control of plasma aldosterone level depends on the secretion rate and the metabolic clearance of the hormone. In this experiments, the metabolic clearance rate of aldosterone was determined in normotensive korean and the effects of adrenal stimulations on the rates were also studied in the same subjects. The metabolic clearance rate of the normal Korean was not significantly different from those of the American, and shown a little increase in response to sodium restriction. These results indicate that the decrease in secretion rate rather than the increase in metabolic clearance Tate is the major factor maintaining lower plasma aldosterone level. After furosemide diuresis, on the contrary, the removal of aldosterone showed significant the decrease despite slight increase of secretion rate. This suggest that the reduction in metabolic clearance rate of the hormone during volume depletion found to be major cause of high plasma concentration. Additional potassium supply produced detectable decrease of metabolic clearance rate, but the changes were smaller than that of secretion rate, which suggested that the higher secretion rate could account for elevated plasma concentration of aldosterone rather than metabolic clearance. Above results also support author's previous evidences that the normal Korean who already adapted to a high sodium diet have ability to produce adequate aldosterone activity without producing detectable changes on the metabolic clearance rate under the condition of sodium restriction with approp riate potassium intake.

  • PDF

Thermal characteristics of spent activated carbon generated from air cleaning units in korean nuclear power plants

  • So, Ji-Yang;Cho, Hang-Rae
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.873-880
    • /
    • 2017
  • To identify the feasibility of disposing of spent activated carbon as a clearance level waste, we performed characterization of radioactive pollution for spent activated carbon through radioisotope analysis; results showed that the C-14 concentrations of about half of the spent activated carbon samples taken from Korean NPPs exceeded the clearance level limit. In this situation, we selected thermal treatment technology to remove C-14 and analyzed the moisture content and thermal characteristics. The results of the moisture content analysis showed that the moisture content of the spent activated carbon is in the range of 1.2-23.9 wt% depending on the operation and storage conditions. The results of TGA indicated that most of the spent activated carbon lost weight in 3 temperature ranges. Through py-GC/MS analysis based on the result of TGA, we found that activated carbon loses weight rapidly with moisture desorption reaching to $100^{\circ}C$ and desorbs various organic and inorganic carbon compounds reaching to $200^{\circ}C$. The result of pyrolysis analysis showed that the experiment of C-14 desorption using thermal treatment technology requires at least 3 steps of heat treatment, including a heat treatment at high temperature over $850^{\circ}C$, in order to reduce the C-14 concentration below the clearance level.

An experimental study for reduction of B.P.F. noise level of multi-blade fan (다익 송풍기의 이산 주파수 소음 저감을 위한 실험적 연구)

  • 김영찬;이상환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.167-175
    • /
    • 1999
  • B.P.F.(Blade Passing Frequency) levels were measured with the cut-off clearance changes. The velocity inside the scroll, pressure fluctuation at cut-off region, and the scroll surface pressure distribution along the scroll from the cut-off to outlet were measured. With a certain cut-off clearance the improvement of efficiency and attenuation of B.P.F. noise level could be achieved. The measured results of pressure fluctuation and scroll surface pressure distribution showed that the secondary flow inside the scroll increased B.P.F. noise level at the cut-off region as the cut-off clearance got wide.

  • PDF

Development of Freeway Traffic Incident Clearance Time Prediction Model by Accident Level (사고등급별 고속도로 교통사고 처리시간 예측모형 개발)

  • LEE, Soong-bong;HAN, Dong Hee;LEE, Young-Ihn
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.5
    • /
    • pp.497-507
    • /
    • 2015
  • Nonrecurrent congestion of freeway was primarily caused by incident. The main cause of incident was known as a traffic accident. Therefore, accurate prediction of traffic incident clearance time is very important in accident management. Traffic accident data on freeway during year 2008 to year 2014 period were analyzed for this study. KNN(K-Nearest Neighbor) algorithm was hired for developing incident clearance time prediction model with the historical traffic accident data. Analysis result of accident data explains the level of accident significantly affect on the incident clearance time. For this reason, incident clearance time was categorized by accident level. Data were sorted by classification of traffic volume, number of lanes and time periods to consider traffic conditions and roadway geometry. Factors affecting incident clearance time were analyzed from the extracted data for identifying similar types of accident. Lastly, weight of detail factors was calculated in order to measure distance metric. Weight was calculated with applying standard method of normal distribution, then incident clearance time was predicted. Prediction result of model showed a lower prediction error(MAPE) than models of previous studies. The improve model developed in this study is expected to contribute to the efficient highway operation management when incident occurs.

Mechanisms of Amyloid-β Peptide Clearance: Potential Therapeutic Targets for Alzheimer's Disease

  • Yoon, Sang-Sun;AhnJo, Sang-Mee
    • Biomolecules & Therapeutics
    • /
    • v.20 no.3
    • /
    • pp.245-255
    • /
    • 2012
  • Amyloid-${\beta}$ peptide ($A{\beta}$) is still best known as a molecule to cause Alzheimer's disease (AD) through accumulation and deposition within the frontal cortex and hippocampus in the brain. Thus, strategies on developing AD drugs have been focused on the reduction of $A{\beta}$ in the brain. Since accumulation of $A{\beta}$ depends on the rate of its synthesis and clearance, the metabolic pathway of $A{\beta}$ in the brain and the whole body should be carefully explored for AD research. Although the synthetic pathway of $A{\beta}$ is equally important, we summarize primarily the clearance pathway in this paper because the former has been extensively reviewed in previous studies. The clearance of $A{\beta}$ from the brain is accomplished by several mechanisms which include non-enzymatic and enzymatic pathways. Nonenzymatic pathway includes interstitial fluid drainage, uptake by microglial phagocytosis, and transport across the blood vessel walls into the circulation. Multiple $A{\beta}$-degrading enzymes (ADE) implicated in the clearance process have been identified, which include neprilysin, insulin-degrading enzyme, matrix metalloproteinase-9, glutamate carboxypeptidase II and others. A series of studies on $A{\beta}$ clearance mechanism provide new insight into the pathogenesis of AD at the molecular level and suggest a new target for the development of novel therapeutics.

Safety Evaluation of Clearance of Radioactive Metal Waste After Decommissioning of NPP (원전해체후 규제해제 대상 금속폐기물에 대한 자체처분 안전성 평가)

  • Choi, Young-Hwan;Ko, Jae-Hun;Lee, Dong-Gyu;Hwang, Young-Hwan;Lee, Mi-Hyun;Lee, Ji-Hoon;Hong, Sang-Bum
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.291-303
    • /
    • 2020
  • The Kori-Unit 1 nuclear power plant, which is scheduled to be decommissioned after permanent shutdown, is expected to generate large amounts of various types of radioactive waste during the decommissioning process. Among these, nuclear reactors and internal structures have high levels of radioactivity and the dismantled structure must have the proper size and weight on the primary side. During decommissioning, it is important to prepare an appropriate and efficient disposal method through analysis of the disposal status and the legal restrictions on wastes generated from the reactors and internal structures. Nuclear reactors and internal structures generate radioactive wastes of various levels, such as medium, very low, and clearance. A radiation evaluation indicates that wastes in the clearance level are generated in the reactor head and upper head insulation. In this study, a clearance waste safety evaluation was conducted using the RESRAD-RECYCLE code, which is a safety evaluation code, based on the activation evaluation results for the clearance level wastes. The clearance scenario for the target radioactive waste was selected and the maximum individual and collective exposure doses at the time of clearance were calculated to determine whether the clearance criteria limit prescribed by the Nuclear Safety Act was satisfied. The evaluation results indicated that the doses were significantly low, and the clearance criteria were satisfied. Based on the safety assessment results, an appropriate metal recycle and disposal method were suggested for clearance, which are the subject of the deregulation of internal structures of nuclear power plant.

Safety Assessment for the self-disposal plan of clearance radioactive waste after nuclear power plant decommissioning (원전해체후 규제해제 콘크리트 방사성 폐기물의 자체처분을 위한 안전성 평가)

  • Choi, YoungHwan;Ko, JaeHun;Lee, DongGyu;Kim, HaeWoong;Park, KwangSoo;Sohn, HeeDong
    • Journal of Energy Engineering
    • /
    • v.29 no.1
    • /
    • pp.63-74
    • /
    • 2020
  • The Kori-Unit 1 nuclear power plant, which is scheduled for decommissioning after permanent shutdown, is expected to generate a large amount of various types of radioactive waste during decommissioning process. For concrete radioactive waste, which is expected to occupy the most amount, it is important to analyze the current waste disposal status and legal limitations and to prepare an appropriate and efficient disposal method. Concrete radioactive waste is waste of various levels, of which the clearance level is bioshield concrete. In this paper, clearance radioactive waste safety evaluation was performed using the RESRAD code, which is a safety evaluation code, based on the activation evaluation results for the wastes with the clearance level. The clearance scenario of the target radioactive waste was selected and the individual's exposure dose was calculated at the time of clearance to determine whether the clearance criteria limit prescribed by the Nuclear Safety Act was satisfied. As a result of the evaluation, the results showed significantly lower results and satisfied the criteria value. Based on the results of this clearance safety assessment, the appropriate disposal method for bioshield concrete, which are the clearance wastes of subject of deregulation, was suggested.