• Title/Summary/Keyword: Clear Aligner

Search Result 26, Processing Time 0.022 seconds

Integrated three-dimensional digital assessment of accuracy of anterior tooth movement using clear aligners

  • Zhang, Xiao-Juan;He, Li;Guo, Hong-Ming;Tian, Jie;Bai, Yu-Xing;Li, Song
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.275-281
    • /
    • 2015
  • Objective: To assess the accuracy of anterior tooth movement using clear aligners in integrated three-dimensional digital models. Methods: Cone-beam computed tomography was performed before and after treatment with clear aligners in 32 patients. Plaster casts were laser-scanned for virtual setup and aligner fabrication. Differences in predicted and achieved root and crown positions of anterior teeth were compared on superimposed maxillofacial digital images and virtual models and analyzed by Student's t-test. Results: The mean discrepancies in maxillary and mandibular crown positions were $0.376{\pm}0.041mm$ and $0.398{\pm}0.037mm$, respectively. Maxillary and mandibular root positions differed by $2.062{\pm}0.128mm$ and $1.941{\pm}0.154mm$, respectively. Conclusions: Crowns but not roots of anterior teeth can be moved to designated positions using clear aligners, because these appliances cause tooth movement by tilting motion.

Force changes associated with differential activation of en-masse retraction and/or intrusion with clear aligners

  • Zhu, Ye;Hu, Wei;Li, Shuo
    • The korean journal of orthodontics
    • /
    • v.51 no.1
    • /
    • pp.32-42
    • /
    • 2021
  • Objective: To investigate the three-dimensional forces created by clear aligners on mandibular teeth during differential activation with en-masse retraction and/or intrusion in vitro. Methods: Six sets of clear aligners were designed for differential en-masse retraction and/or intrusion procedures in a first premolar extraction model. Group A0 was a control group with no activation. Groups A1-5 underwent different degrees of retractions and/or intrusions. Each group consisted of 10 aligners. Aligner forces were measured on a multi-axis force/torque transducer measurement system in real-time. Results: In the en-masse retraction groups (A1 and A2), lingual and extrusive forces were observed on the incisors; the canines mainly received distal forces; intrusive forces were seen on the second premolars; and the molars received mesial forces. In the en-masse retraction and intrusion groups (A3, A4, and A5), incisors also received lingual and extrusive forces; canines received distal and intrusive forces; mesial and extrusive forces were seen on the second premolars; and the second molars received distal and intrusive forces. The vertical forces on the incisors did not differ significantly among groups A1, A3, and A5. However, the vertical forces on the second premolars reversed from intrusion in group A1 to extrusion in groups A3 and A5. Conclusions: With clear aligners, the "bowing effect" is seen during en-masse anterior teeth retraction and can be partially relieved by performing en-masse retraction accompanied by anterior teeth intrusion. Vertical control of incisors remained unsolved during en-masse retraction, even when intrusive activation was added to the anterior teeth.

Diagnosis and Treatment of Malocclusions using the Invisalign System (인비절라인 시스템을 이용한 부정교합의 진단 및 치료)

  • Kim, Hyungsoo;Ahn, Jae-Hyun;Boyd, Robert L.
    • The korean journal of orthodontics
    • /
    • v.33 no.1 s.96
    • /
    • pp.21-29
    • /
    • 2003
  • Recent developments in software technology have made it possible to create a virtual three-dimensional model of the dental arches from digitally scanned casts of a patient's dentition. This modelmay then be manipulated with software to produce stages of tooth movement from the initial malocclusion to the final desired occlusion. A sterolithograghic model is made for each stage of tooth movement which is the basis for construction of a series of clear and thin overlay appliances. These appliances are worn full time by the patient to move the teeth according to the programmed stages of movement. Malocclusions involving mild to moderate crowding and space closure have been proven to be successfully treated with this appliance. Experience with this appliance has demonstrated excellent patient compliance with less discomfort, improved esthetics and oral hygiene control, when compared with fixed orthodontic appliances. Orthodontic treatment with this appliance is a potentially useful alternative approach to fixed appliances for treatment of a variety of malocclusions in patients with fully erupted permanent teeth.

External apical root resorption 6 months after initiation of orthodontic treatment: A randomized clinical trial comparing fixed appliances and orthodontic aligners

  • Toyokawa-Sperandio, Katia Cristina;Conti, Ana Claudia de Castro Ferreira;Fernandes, Thais Maria Freire;de Almeida-Pedrin, Renata Rodrigues;de Almeida, Marcio Rodrigues;Oltramari, Paula Vanessa Pedron
    • The korean journal of orthodontics
    • /
    • v.51 no.5
    • /
    • pp.329-336
    • /
    • 2021
  • Objective: To compare the magnitude of external apical root resorption (EARR) 6 months after starting orthodontic treatment using orthodontic aligners (OAs) and fixed appliances (FAs). Methods: This parallel randomized clinical trial included 40 patients randomized into two groups: OA group (n = 20, 160 incisors) and FA group (n = 20, 160 incisors). For evaluation of the tooth length, periapical radiographs and standardized linear measurements of the maxillary and mandibular incisors were acquired before (T0) and 6 months after treatment initiation (T1). EARR was calculated through the difference in length between the two time points (T1-T0). Statistical comparisons were performed by means of using t-tests, chi-squared test and covariance analysis (a = 5%). Results: Rounding of the root apex was observed in both groups; the resorption involved 2.88% of the root length, so 97.12% of the tooth length remained intact. Intragroup comparisons between the two time points revealed a significant difference, with (T1-T0) ranging from -0.52 to -0.88 mm in the FA group and from -0.52 to -0.85 mm in the OA group. In the intergroup comparisons, only tooth #21 presented a statistically significant difference (OA: -0.52 ± 0.57 mm, FA: -0.86 ± 0.60 mm); however, the overall differences between groups were not clinically relevant, ranging from 0.03 to 0.35 mm. Conclusions: OA and FA treatment resulted in a similar degree of EARR in the maxillary and mandibular incisors at 6 months after treatment initiation. However, the amount of resorption was small and does not impair tooth longevity.

Effectiveness of the Invisalign Mandibular Advancement Appliance in Children with Class II Division 1 Malocclusion

  • So-Youn An;Hyeon-Jin Kim;Ho-Uk Lee;Sang-Ho Bak;Hyo-Jin Kang;Youn-Soo Shim
    • Journal of dental hygiene science
    • /
    • v.23 no.4
    • /
    • pp.245-254
    • /
    • 2023
  • Background: This study aimed to determine the skeletal and dental effects in pediatric and adolescent Korean patients with Class II Division 1 malocclusion treated using the Invisalign Mandibular Advancement (MA®) appliance. Methods: The study included patients aged 6 to 18 years who received orthodontic treatment with the MA® appliance for Class II Division 1 malocclusion at the Department of Pediatric Dentistry, Wonkwnag University Daejeon Dental Hospital, between July 1, 2018, and December 31, 2021. The treatment group consisted of 20 patients, 10 boys and 10 girls. The control participants were also 10 boys and 10 girls. Lateral cephalometric radiographs were taken before and after treatment, and 41 measurements of skeletal and dental changes were measured and analyzed using the V-CephTM 8.0 (Osstem Implant). All analyses were performed using SPSS software (IBM SPSS for Windows, ver 26.0; IBM Corp.), and statistical significance was tested using paired and independent samples t-tests for within-group and between-group comparisons, respectively. Results: The patients in the treatment group showed significant decreases in ANB (A point, Nasion, B point), maxillary protrusion, maxillary anterior incisor labial inclination, and maxillary protrusion after treatment. However, when compared with the growth changes observed in the control group, only ANB and maxillary protrusion decreased, with no significant differences in SNA, SNB, and mandibular length. Conclusion: Collectively, the results of this study confirm that the use of MA® appliance in pediatric and adolescent Korean patients with Class II Division 1 malocclusion results in a reduction of anteroposterior skeletal and dental disharmony.

Application of 3D printer in dental clinic (치과 진료실에서 3D 프린트의 활용)

  • Kim, Hyun Dong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.2
    • /
    • pp.82-96
    • /
    • 2018
  • 3D printing is a process of producing 3d object from a digital file in STL format by joining, bonding, sintering or polymerizing small volume elements by layer. The various type of 3d printing is classified according to the additive manufacturing strategies. Among the types of 3D printer, SLA(StereoLithography Apparatus) and DLP(Digital Light Processing) 3D printer which use polymerization by light source are widely used in dental office. In the previous study, a full-arch scale 3d printed model is less precise than a conventional stone model. However, in scale of quadrant arch, a 3d printed model is significantly precise than a five-axis milled model. Using $3^{rd}$ Party dental CAD program, full denture, provisional crowns and diagnostic wax-up model are fabricated by 3d printer in dental office. In Orthodontics, based on virtual setup model, indirect bracket bonding tray can be generated by 3d printer. And thermoforming clear aligner can be fabricated on the 3d printed model. 3D printed individual drilling guide enable the clinician to place the dental implant on the proper position. The development of layer additive technology enhance the quality of 3d printing object and shorten the operating time of 3D printing. In the near future, traditional dental laboratory process such as casting, denture curing will be replaced by digital 3D printing.