• Title/Summary/Keyword: Cleaning Performance

Search Result 470, Processing Time 0.029 seconds

Analysis and Survey for Contamination of Deoxynivalenol and Zearalenone in Feed by High Performance Liquid Chromatography (HPLC를 이용한 사료 중 Deoxynivalenol, Zearalenone의 분석과 오염도 조사)

  • Kim, Dong-Ho;Choi, Kyu-Il;Hong, Kyung-Suk;Kim, Hyun-Jung;Song, Yeong-Jin;Gang, Seung-Hun;Jang, Han-Sub;Cho, Hyun-Jung;Han, Gye-Su
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.3
    • /
    • pp.214-221
    • /
    • 2011
  • Deoxynivalenol (DON) and zearalenone (ZEN) are mainly contaminated mycotoxins in feeds. The study was carried out to analyze and survey the contamination of DON and ZEN in one hundred thirteen samples of feeds. After cleaning all samples with immunoaffinity column, the mycotoxins were analysed by using high performance liquid chromatography/fluorescence with diode array detector (HPLC/FLD with DAD). The average recoveries of DON were 88.76 and 95.40% at the levels of 200 and 1,000 ${\mu}g/kg$ and 87.09 and 98.40% of ZEN were recovered at the levels of 100 and 500 ${\mu}g/kg$, respectively. The limit of detection (LOD) were 6.0 and 3.0 ${\mu}g/kg$ for DON and ZEN, respectively. The average concentrations of DON were 372.1, 324.0 and 990.9 ${\mu}g/kg$ in chicken, pig and cattle feed, respectively. Those of ZEN were 76.1, 43.7 and 196.2 ${\mu}g/kg$ for them, individually.

Low Noise Vacuum Cleaner Design (저소음 청소기 개발)

  • Joo, Jae-Man;Lee, Jun-Hwa;Hong, Seun-Gee;Oh, Jang-Keun;Song, Hwa-Gyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.939-942
    • /
    • 2007
  • Vacuum cleaner is a close life product that can remove various dusts from our surroundings. However well vacuum cleaner clean our environments, many people are looking away from it, due to its loud noise. Its noise causes a big trouble in the usual life, for example, catch calls, TV watching and discussing etc. To reduce these inconveniences, noise reduction methods and systematic design of low noise vacuum cleaner are studied in this paper. At first, sound quality investigation is performed to get the noise level and quality that make people TV watching and catch calls available. Based on the European and domestic customer SQ survey result, sound power, peak noise level and target sound spectrum guideline are studied and introduced. As a second, precise product sound spectrums are designed into each part based on the sound quality result. Fan-motor, brush, mainbody, cyclone spectrums are decided to get the final target sound based on the contribution level. Fan-motor is the major noise source of vacuum cleaner. Specially, its peak sound, RPM peak and BPF Peak, cause the people nervous. To reduce these peak sounds, high rotating impeller and diffuser are focused due to its interaction. A lot of experimental and numerical tests, operation points are investigated and optimization of flow path area between diffusers is performed. As a bagless device, cyclones are one of the major noise sources of vacuum cleaner. To reduce its noise, previous research is used and adopted well. Brush is the most difficult part to reduce noise. Its noise sources are all comes from aero-acoustic phenomena. Numerical analysis helps the understanding of flow structure and pattern, and a lot of experimental test are performed to reduce the noise. Gaps between the carpet and brush are optimized and flow paths are re-designed to lower the noise. Reduction is performed with keeping the cleaning efficiency and handling power together and much reduction of noise is acquired. With all above parts, main-body design is studied. To do a systematic design, configuration design developments technique is introduced from airplane design and evolved with each component design. As a first configuration, fan-motor installation position is investigated and 10 configuration ideas are developed and tested. As a second step, reduced size and compressed configuration candidates are tested and evaluated by a lot of major factor. Noise, power, mass production availability, size, flow path are evaluated together. If noise reduction configuration results in other performance degrade, the noise reduction configuration is ineffective. As a third configuration, cyclones are introduced and the size is reduced one more time and fourth, fifth, sixth, seventh configuration are evolved with size and design image with noise and other performance indexes. Finally we can get a overall much noise level reduction configuration. All above investigations are adopted into vacuum cleaner design and final customer satisfaction tests in Europe are performed. 1st grade sound quality and lowest noise level of bagless vacuum cleaner are achieved.

  • PDF

A Study on Self Care Compliance Related to Infection Management for Continuous Ambulatory Peritoneal Dialysis Patients (복막투석환자의 감염예방과 관련된 자가간호 이행에 관한 연구)

  • Lee Eun-Young;Kim Jung-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.2
    • /
    • pp.313-323
    • /
    • 1998
  • This study was a descriptive research on the level of self-care available to continous ambulatory peritoneal dialysis patients (hereinafter referred to as 'CAPD patient') related to the specific area of infection management. The method employed for the collection of data was a modified instrument of the self-care survey essentially based on Young Sook Choi's instrument. The relevant data was collected from september 1, 1996 to september 30, 1996. The subjects were provided with an open-ended question regarding the reasons behind why they did not seek self-care. The answers provided about self-care compliance were analyzed by SPSS for frequency, percentage, mean, t-test, ANOVA. Reasons for non-compliance were analyzed by content analysis. The results of the study were as follows : 1. The percentage of patients engaging in self-care were according to the following self performed tasks : preparation of dialysis : 30.58 points Dialysate exchange procedures : 49.40 points - Two bag type : 50.50 points - Spike type : 48.80 points - Neo type : 48.90 points Catheter exit site care : 25.13 points More specifically, in relation to the preparation of dialysis as referred to above, those patients engaging in self care was relatively high with respect to the cleaning of the dialysis before use and for the preservation of peritosol. However, in dialysate exchange procedures, data revealed that those patients engaging in self-care are relatively low with respect to putting on a mask during the performance of peritosol exchange. Similary in peritosol exchange procedure and catheter exit care, low levels of self-care performance were found in the area of putting on a mask during the peritosol exchange procedures and catheter line testing procedures, respectively. 2. In general characteristics, there appeared to be no distinction in self-care compliance among CAPD patients. 3. The main reasons for non-compliance were based in the following factor : intellectual, attitude, enviromental surrounding and physical. As a result of the foregoing finding, nurses should provide adequate assistance to promote self-care compliance by CAPD patients by checking the preparation of dialysis, dialysate exchange procedure, and catheter exit site care which recieved low point in this research.

  • PDF

An Overview on the Physicochemical Properties and Photocatalytic Pollutant Removal Performances of TiO2-incorporated Cementitious Composites (TiO2 혼입 시멘트 복합체의 물리·화학적 특성 및 광촉매 반응을 이용한 오염물 제거 성능에 대한 개요)

  • Seo, J.H.;Yoon, H.N.;Kim, S.H.;Bae, S.J.;Jang, D.I.;Kil, T.G.;Park, S.M.;Lee, H.K.
    • Composites Research
    • /
    • v.33 no.2
    • /
    • pp.68-75
    • /
    • 2020
  • Recently, the use of TiO2 as a phtocatalyst has been diversely investigated due to its excellent durability performance and high photocatalytic reaction efficiency. Active researches have particularly focused on the development of TiO2-incorporated cementitious composites in order to remove the atmospheric pollutants. Furthermore, the potential utilization of TiO2-incorporated cementitious composites as road accessories such as tunnels, road median separators and soundproof walls in the form of tiles, blocks and structural components has been widely examined. In this regard, a thorough understanding on the material characteristics of TiO2-incorporated cementitious composites should be preceded. The present overview article, therefore, revisits previous studies of TiO2-incorporated cementitious composites and summarizes their various physicochemical properties and atmospheric pollutants removal performance.

Clinical Microscopy: Performance, Maintenance and Laser Safety (임상에서의 현미경: 작동, 유지보수 및 레이저 안전)

  • Lee, Tae Bok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.125-133
    • /
    • 2019
  • A microscope is the fundamental research and diagnostic apparatus for clinical investigation of signaling transduction, morphological changes and physiological tracking of cells and intact tissues from patients in the biomedical laboratory science. Proper use, care and maintenance of microscope with comprehensive understanding in mechanism are fully requested for reliable image data and accurate interpretation for diagnosis in the clinical laboratory. The standard operating procedure (SOP) for light microscopes includes performance procedure, brief information of all mechanical parts of microscopes with systematic troubleshooting mechanism depending on the laboratory capacity. Maintenance program encompasses cleaning objective, ocular lenses and inner optics; replacement and calibration of light source; XY sample stage management; point spread function (PSF) measurement for confocal laser scanning microscope (CLSM); quality control (QC) program in fluorescent microscopy; and systematic troubleshooting. Laser safety is one of the concern for medical technologists engaged in CLSM laboratory. Laser safety guideline based on the laser classification and risk level, and advisory lab wear for CLSM users are also expatiated in this overview. Since acquired image data presents a wide range of information at the moment of acquisition, well-maintained microscopes with proper microscopic maintenance program are impulsive for its interpretation and diagnosis in the clinical laboratory.

Influence of COVID-19 on Public Transportation Mode Change and Countermeasures (COVID-19에 따른 대중교통수단 변화에 미치는 영향 분석 및 대책에 관한 연구)

  • Kim, Su Min;Jung, Hun Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.379-389
    • /
    • 2022
  • The number of public transportation users has dropped drastically due to COVID-19. In this work, my survey was conducted to uncover the factors that influence citizens' travel patterns. Data were collected and logistic regression analysis on the shifts in transportation was undertaken. Additionally, an importance-performance analysis was carried out to investigate how to effectively operate public transportation systems and improve facilities. The main research findings were as follows: First, the more individuals were concerned about COVID-19 (+) and being infected when using public transportation (+), the greater the tendency to switch to private transportation modes. Secondly, when it came to personal traits, respondents who could drive a car (+) or owned a car (+)or did more online shopping (+) or used public transportation for trips (+) tended to switch over, compared with respondents who could not drive or did not own a caror used public transportation to commute. In addition, respondents who were vaccinated (-) or had more household members tended not to switch transportation modes, compared with those who were not vaccinated or had fewer household members. Third, it is important to continue the following efforts to safeguardhygiene linked to public transportation: wearing masks, disinfecting hands, controlling diseases, and general cleaning. The conclusion was that it is important to put traffic congestion and ventilation issues first, especially in regards public transportation, which was not rated as satisfactory enough compared to its importance. The research findings can provide useful basic data when establishing countermeasures to the current COVID-19 circumstances in the areas of public transportation operation and management and in the event of an infectious disease outbreak in the future.

Improvement of existing drainage system for leakage treatment in exiting underground structures (운영중인 지하구조물의 누수처리를 위한 유도배수공법의 개선)

  • Kim, Dong-Gyou;Yim, Min-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.4
    • /
    • pp.669-683
    • /
    • 2017
  • The objective of this study is to propose a modification of the previously proposed drainage system for catching the partial leakage of underground concrete structures. Two techniques were proposed for applying the drainage system only to the leaking parts. One was for conveying leaking groundwater to the collection point in the drainage system and the other was for conveying the collected groundwater to the primary drainage system of the underground concrete structure. Four waterproofing materials for conveying leaking groundwater to the catchment point of the drainage system, Durkflex made of porous rubber material, KE-45 silicone adhesive with super strong adhesion, Hotty-gel made of polymeric materials and general silicone adhesive were evaluated for waterproofing performance. Hotty-gel only showed perfect waterproof performance and the other three waterproof materials leaked. The modified drainage system with Hotty-gel and drainage pipe with fixed saddle to convey the leaking groundwater from the catchment point to the primary drainage system were tested on the concrete retaining wall. The waterproof performance and the drainage performance were evaluated by injecting 1,000 ml of water in the back of the modified drainage system at the 7-day, 14-day, 21-day, 28-day, 2-month and 3-month. There was no problem in waterproof performance and drainage performance of the modified drainage system during 3 months. In order to evaluate the construction period and construction cost of the modified drainage system, it was compared with the existing leaching repair method in surface cleaning stage, leakage treatment stage, and protective barrier stage. Total construction period and construction cost were compared in considering the contents of work, repair material, construction equipment, working time, and total number of workers. As a result of comparing and analyzing in each construction stage, it was concluded that the modified drainage system could save construction period and construction cost compared to the existing leaching repair method.

Performance enhancement of Organic Thin Film Transistor by Ar Ion Beam treatment (Ar Ion Beam 처리를 통한 Organic Thin Film Transistor의 성능향상)

  • Jung, Suk-Mo;Park, Jae-Young;Yi, Moon-Suk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.15-19
    • /
    • 2007
  • This paper reports the effects of Ar ion beam surface treatment on a $SiO_2$ dielectric layer in organic thin film transistors. We compared the electrical properties of pentacene-based OTFTs, treated by $O_2$ plasma or Ar ion beam treatments and characterized the states of the surface of the dielectric by using atomic force microscopy and X-ray photoelectron spectroscopy. For the sample which received $O_2$ plasma treatment, the mobility increased significantly but the on/off current ratio was found very low. The Ar ion beam-treated sample showed a very high on/off current ratio as well as a moderately improved mobility. XPS data taken from the dielectric surfaces after each of treatments exhibit that the ratio of between Si-O bonds and O-Si-O bonds was much higher in the $O_2$ plasma treated surface than in the Ar ion beam treated surface. We believe that our surface treatment using an inert gas, Ar, carried out an effective surface cleaning while keeping surface damage very low, and also the improved device performances was achieved as a consequence of improved surface condition.

A Study on Operating Condition of Test-Bed Plant using Membrane filtration of D Water Treatment Plant in Gwang-Ju (D정수장 정밀여과막 실증플랜트의 최적 운전조건 연구)

  • Yang, Hyung-Jae;Yi, Seung-Hoon;Moon, Kyung-Ran
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.3
    • /
    • pp.155-163
    • /
    • 2017
  • Membrane filtration has become more popular in drinking water treatment recently, since the filtration can control not only particulate matters but also pathogenic microorganisms such as giardia and cryptosporidium very effectively. Pilot-scale ($120m^3/d$ of treatment capacity) and test-bed ($25,000m^3/d$ of treatment capacity) microfiltration experiments were conducted to find optimum operating mode and the critical flux. Optimum operating mode of pilot-test was assessed as inflow 1.0 min, filtration 36.5 min, air backwash 0.9 min, backwash 1.0 min and outflow 1.0 min with 50 LMH ($L/min{\cdot}m3^$) of critical flux. Critical Flux was calculated to be $50L/m^2-h$ (within TMP 0.5 bar) based on the increase formula of the transmembrane pressure difference according to the change of time at Flux 20, 40, 56 and 62 LMH in pilot operation. Chemical cleaning was first acid washed twice, and alkali washing was performed secondarily, and a recovery rate of 95% was obtained in the test-bed plant. The results of operating under these appropriate conditions are as follows. Turbidity of treated water were 0.028, 0.024, 0.026 and 0.028 NTU in spring, summer, autumn and winter time, respectively. Microfiltration has superior treatment capability and performance characteristics in removing suspended solids and colloidal materials, which are the main cause of turbidity and important carrier of metal elements, and it has shown great potential in being an economically substitute to traditional processes (sand filtration).

Effect of Saw-Damage Etching Conditions on Flexural Strength in Si Wafers for Silicon Solar Cells (태양전지용 실리콘 기판의 절삭손상 식각 조건에 의한 곡강도 변화)

  • Kang, Byung-Jun;Park, Sung-Eun;Lee, Seung-Hun;Kim, Hyun-Ho;Shin, Bong-Gul;Kwon, Soon-Woo;Byeon, Jai-Won;Yoon, Se-Wang;Kim, Dong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.20 no.11
    • /
    • pp.617-622
    • /
    • 2010
  • We have studied methods to save Si source during the fabrication process of crystalline Si solar cells. One way is to use a thin silicon wafer substrate. As the thickness of the wafers is reduced, mechanical fractures of the substrate increase with the mechanical handling of the thin wafers. It is expected that the mechanical fractures lead to a dropping of yield in the solar cell process. In this study, the mechanical properties of 220-micrometer-solar grade Cz p-type monocrystalline Si wafers were investigated by varying saw-damage etching conditions in order to improve the flexural strength of ultra-thin monocrystalline Si solar cells. Potassium hydroxide (KOH) solution and tetramethyl ammonium hydroxide (TMAH) solution were used as etching solutions. Etching processes were operated with a varying of the ratio of KOH and TMAH solutions in different temperature conditions. After saw-damage etching, wafers were cleaned with a modified RCA cleaning method for ten minutes. Each sample was divided into 42 pieces using an automatic dicing saw machine. The surface morphologies were investigated by scanning electron microscopy and 3D optical microscopy. The thickness distribution was measured by micrometer. The strength distribution was measured with a 4-point-bending tester. As a result, TMAH solution at $90^{\circ}C$ showed the best performance for flexural strength.