• Title/Summary/Keyword: Cleaning Performance

Search Result 470, Processing Time 0.026 seconds

Evaluation of Indoor Air Quality Improvement by Formaldehyde Emission Rate in School Indoor Environment Using Mass Balance (물질수지를 이용한 학교 실내환경의 포름알데히드(HCHO) 배출량 산정에 의한 실내공기질 개선 평가)

  • Yang, Won-Ho;Son, Bu-Soon;Kim, Dae-Won;Kim, Young-Hee;Byeon, Jae-Cheol;Jung, Soon-won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.160-165
    • /
    • 2005
  • Schools have significant and serious indoor environmental health problem, of which indoor air quality (IAQ) in school building may affect the health of the students and indirectly affect learning performance. Schools are of special concern when regarding indoor exposure to air pollutants, because students are particularly sensitive to pollutants and spend a significant amount of time in that environment. Therefore researches for improvement of indoor air quality have been developed such as installation of air cleaning device, ventilation system, titanium dioxide(TiO2) coating and so on. However, it is difficult to evaluate the magnitude of improvement of indoor air quality in field study because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. In this study, evaluation of reduction of formaldehyde emission rate in school indoor environments by far-Infrared ray coating material was carried out using mass balance model in indoor environment. we proposed the evaluation method of magnitude of improvement in indoor air quality, considering outdoor level and ventilation. Since simple indoor concentration measurements could not properly evaluate the indoor air quality, outdoor level and ventilation should be considered when evaluate the indoor air quality.

The Analyses of Customer Satisfaction Index on University Library Service (대학도서관서비스에 대한 고객만족도 분석)

  • 백항기
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.12 no.1
    • /
    • pp.43-64
    • /
    • 2001
  • The purpose of this study was to measure performance of university libraries, especially investigating the components of service quality and their relationship to the customer satisfaction. The result of the statistical analyses is summarized as follows: The result of 5 point scale study shows the following degree of satisfaction in 55 components: timeliness of circulation, processing of fine. location of library, usefulness of retrieval system, library user education, speed of retrieval. number of terminals, and cleaning. On the other hand, shows the following degree of dissatisfaction in 55 components: speed of civil petitions, hour for program use, result of civil petitions, fixing of library user education, speed of retrieval, method of public relation, waiting time for Internet use, and use of the other library materials. Also. customers’matters of weight and importance was availability. learning facilities, suitable collections, circulation, and system of retrieval.

  • PDF

A Survey on Environmental Safety Focussed on Cleanliness for Hospitalized Patients (병원환경의 안전관리를 위한 기초조사 -청결도를 중심으로-)

  • 박점희
    • Journal of Korean Academy of Nursing
    • /
    • v.7 no.1
    • /
    • pp.99-111
    • /
    • 1977
  • One of the fundamental provisions that a hospital requires is the environmental safety through cleanliness s. The effective management of atmospheric conditions, i. e. air purity, cleanliness of facilities furnitures and bed- linen instruments are direct- environment of hospitalized patients. Meeting physical cleanliness needs of patients, application of aseptic teaching while carrying out nursing measures and the cleanliness of hospital personnel are another categories of concern. This study was carried out, from March through April 1976, to investigate the degree of satisfaction on cleanliness that patients perceived, and to compare with that of nurses on their nursing performances. 44 questionaries categorized into 6 major concern were used. For the survey, 269 patients and 191 nurses of 3 general hospitals in Taegu: kyung-puk University Hospital, Presbyterian Mission Hospital, and Catholic Patima Hospital and 116 senior nursing students from Kyung-Puk University and Presbyterian School of Nursing were randomly sampled. Results are as follows : 1. Mean satisfaction score on cleanliness revealed to be average on patients, on nursing performance for cleanliness revealed to be average in nursing students and relatively high in graduate nurses. 2. Mean score of patients revealed to be significantly lower in comparison with that of nursing. 3. Mean score of nurses revealed to be significantly higher in comparison with that of nursing students. 4. Mean score of patients revealed to be significantly lower in comparison with nursing students. 5. Mean satisfaction score of patient3 in all categories revealed to be the lowest in the rank order . 6. The lowest categorial mean score revealed to be the linen and instrument in all three groups. Recommendations 1. A more satisfactory mean of cleaning (medical asperses of mouth thermometers needs to be developed. 2. Further investigation to clarify the difference between patients and nurses on hospital cleanliness is recommended.

  • PDF

Ultrafiltration membranes for drinking-water production from low-quality surface water: A case study in Spain

  • Rojas-Serrano, Fatima;Alvarez-Arroyo, Rocio;Perez, Jorge I.;Plaza, Fidel;Garralon, Gloria;Gomez, Miguel A.
    • Membrane and Water Treatment
    • /
    • v.6 no.1
    • /
    • pp.77-94
    • /
    • 2015
  • Ultrafiltration membranes have several advantages over conventional drinking-water treatment. However, this technology presents major limitations, such as irreversible fouling and low removal of natural organic matter. Fouling depends heavily on the raw-water quality as well as on the operating conditions of the process, including flux, permeate recovery, pre-treatment, chemical cleaning, and backwashing. Starting with the premise that the optimisation of operating variables can improve membrane performance, different experiments were conducted in a pilot plant located in Granada (Spain). Several combinations of permeate and backwashing flow rates, backwashing frequencies, and aeration flow rates were tested for low-quality water coming from Genil River with the following results: the effluent quality did not depend on the combination of operating conditions chosen; and the membrane was effective for the removal of microorganisms, turbidity and suspended solids but the yields for the removal of dissolved organic carbon were extremely low. In addition, the threshold transmembrane pressure (-0.7 bar) was reached within a few hours and it was difficult to recover due to the low efficiency of the chemical cleanings. Moreover, greater transmembrane pressure due to fouling also increased the energy consumption, and it was not possible to lower it without compromising the permeate recovery. Finally, the intensification of aeration contributed positively to lengthening the operation times but again raised energy consumption. In light of these findings, the feasibility of ultrafiltration as a single treatment is questioned for low-quality influents.

Reuse of Petroleum Refinery Wastewater Using Reverse Osmosis Membrane (역삼투막을 이용한 정유산업 폐수 재활용 연구)

  • Hwang, Jong-Sic;Sang, Byoung-In;Yoo, Je-Kang;Lee, Kyu-Hyun;Min, Byoung-Ryul;Kim, Byoung-Sik
    • Membrane Journal
    • /
    • v.4 no.4
    • /
    • pp.213-220
    • /
    • 1994
  • Reverse osmosis(R/O) pilot system, which consists of pretreatments and R/O membranes, was demonstrated to regenerate the petroleum refinery wastewater for the process feedwater supply. Despite of the unsteady quality of the wastewater effluent from the process facilities, relatively high salt rejection of 96~99% was obtained and the product water showed a feasible quality for the use of cooling tower feed water. The results of R/O membrane module cleaning with NaOH solution represented that there was some fouling effects on the membrane performance during the period of test due to the ineffective treatment processes proposed and used in this study.

  • PDF

Research on Step-Type Chemical Liquid Deodorizer using Liquid Catalyst

  • WOO, Hyun-Jin;KWON, Lee-Seung;JUNG, Min-Jae;YEO, Og-Gyu;KIM, Young-Do;KWON, Woo-Taeg
    • The Korean Journal of Food & Health Convergence
    • /
    • v.6 no.5
    • /
    • pp.19-25
    • /
    • 2020
  • The purpose of this study was to research and develop a step-type chemical liquid deodorizer including a liquid catalyst that can prevent civil complaints due to odor due to its excellent deodorizing performance. The main composition of chemical liquid deodorizer including liquid catalyst is cleaning deodorization, catalyst deodorization, chemical deodorization, water film plate, deodorization water circulation device, deodorization water injection device, catalyst management system, gas-liquid separation device, chemical supply device, deodorizer control panel, etc. It consists of a device. The air flow of the step-type liquid catalyst chemical liquid deodorizer is a technology that firstly removes basic odor substances, and the liquid catalyst installed in the subsequent process stably removes sulfur compounds, which are acidic odor substances, to discharge clean air. The efficiency of treating the complex odor of the prototype was 98.5% for the first and 99.6% for the second, achieving the target of 95%. The hydrogen sulfide treatment efficiency of the prototype was 100% for the first and 99.9% for the second, which achieved 95%, which was the target of the project. As a result, ammonia was removed by the reaction of ammonia and hydrogen sulfide.

Development of wall climbing robot using vacuum adsorption with legged type movement (진공 흡착과 보행형 이동에 의한 벽면이동 로봇의 개발)

  • Park, Soo-Hyun;Seo, Kyeong-Jun;Kim, Sung-Gaun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.344-349
    • /
    • 2017
  • Wall-climbing robots have been developed for various purposes, such as cleaning skyscraper windows, maintaining large structures, and welding vessels. Conventional wall-climbing robots use movement systems based on wheels or legs. However, wheeled robots suffer from slipping effects, while legged systems require many actuators and control systems for the complex linkage structure, which also increases the weight of the robot. To overcome these disadvantages, we propose a new wall-climbing robot that walks based on gorilla locomotion. The proposed robot consists of a DC drive motor, a vacuum pump for adsorption, and a micro controller for controlling the system. The performance of the robot was experimentally verified on vertical and horizontal flat surfaces. The robot could be used for various functions in industrial sites or disaster areas.

Sorghum Harvesting Using a Head-feeding Type Rice Combine

  • Jun, Hyeon Jong;Choi, Il Su;Kang, Tae Gyoung;Choi, Yong;Choi, Duck Kyu;Lee, Choung Keun;Kim, Sang Hun
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.296-302
    • /
    • 2018
  • Purpose: The aim of this study was to determine appropriate threshing and selection conditions for sorghum harvesting using a rice combine-harvester. Methods: Sorghum harvesting performance was tested using an actual rice combine. Through this test, the grain loss rate and the composition of crops according to the engine and fan speeds of the combine were investigated. Furthermore, the optimal threshing and selection conditions were determined by carrying out a harvest test based on the opening size factor of the concave in a test field. Results: The grain loss rate for the sorghum using a concave ($18{\times}18mm$) of the rice combine was the lowest at 0.1% at a chaffer angle of $40^{\circ}$, engine speed of 2000 rpm, and fan speed of 20 m/s, but the sorting sieve clogged frequently. Furthermore, as the engine speed and fan speed increased, the grain loss rate also increased. The sorghum harvesting test results of the combine according to the concave opening size showed that the grain loss rate was 0.5% at a driving speed of 0.5 m/s, with a concave opening diameter of 13 mm, a chaffer angle of $40^{\circ}$, a concave sieve oscillation frequency of 4.8 Hz, a fan speed of 20 m/s, and an engine speed of 2000 rpm. Conclusions: Findings showed that sorghum could be harvested using a head feeding rice combine.

Purification and Characterization of Metalloprotease from Serratia marcescens PPB-26 and Its Application for Detergent Additive

  • Thakur, Shikha;Sharma, Nirmal Kant;Thakur, Neerja;Bhalla, Tek Chand
    • Microbiology and Biotechnology Letters
    • /
    • v.47 no.2
    • /
    • pp.259-268
    • /
    • 2019
  • In this study, the extracellular metalloprotease from Serratia marcescens PPB-26 was purified to homogeneity via ethanol fractionation and DEAE-cellulose column chromatography. Thus, a 3.8-fold purification was achieved with a 20% yield and specific activity of 76.2 U/mg. The purified protease was a 50-kDa monomer whose optimum pH and temperature for activity were 7.5 and $30^{\circ}C$ respectively; however, it was found to remain active in the 5-9 pH range and up to $40^{\circ}C$ for 6 h. The protease had a half-life of 15 days at $4^{\circ}C$, an optimum reaction time of 10 min, and an optimum substrate (casein) concentration of 0.25%. Furthermore, the Michaelis constant ($K_m$) and reaction velocity ($V_{max}$) of the protease were calculated to be 0.28% and $111.11{\mu}moles/(min{\cdot}mg)^{-1}$, respectively. The protease was stable when subjected to metal ions (2 mM), showing increased activity with most (especially $CoCl_2$ and $MgSO_4$ (30.54% increase)). It was also stable when exposed to oxidizing agents, bleaching agents, and detergents (5% v/v for 60 min). It retained 93% of its activity in non-ionic detergents (Tween-20, Tween-80, and Triton X-100). Moreover, wash performance analysis in commercial detergents (Ariel and Tide) showed that not only was the protease capable of protein stain removal, but also reduced cleaning time by 80% when added to detergents. Thus, the Serratia marcescens PPB-26 metalloprotease appears to be a promising new candidate as a laundry additive in the detergent industry.

Preparation of highly hydrophobic PVDF hollow fiber composite membrane with lotus leaf-like surface and its desalination properties

  • Li, Hongbin;Zi, Xingchen;Shi, Wenying;Qin, Longwei;Zhang, Haixia;Qin, Xiaohong
    • Membrane and Water Treatment
    • /
    • v.10 no.4
    • /
    • pp.287-298
    • /
    • 2019
  • Lotus leaf has a special dual micro and nano surface structure which gives its highly hydrophobic surface characteristics and so-called self cleaning effect. In order to endow PVDF hollow fiber membrane with this special structure and improve the hydrophobicity of membrane surface, PVDF hollow fiber composite membranes was obtained through the immersion coating of poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) dilute solution on the outside surface of PVDF support membrane. The prepared PVDF composite membranes were used in the vacuum membrane distillation (VMD) for the desalination. The effects of PVDF-HFP dilute solution concentration in the dope solution and coating time on VMD separation performance was studied. Membranes were characterized by SEM, WCA measurement, porosity, and liquid entry pressure of water. VMD test was carried out using $35g{\cdot}L^{-1}$ NaCl aqueous solution as the feed solution at feed temperature of $30^{\circ}C$ and the permeate pressure of 31.3 kPa. The vapour flux reached a maximum when PVDF-HFP concentration in the dilute solution was 5 wt% and the coating time was kept in the range of 10-60 s. This was attributed to the well configuration of micro-nano rods which was similar with the dual micro-nano structure on the lotus leaf. Compared with the original PVDF membrane, the salt rejection can be well maintained which was greater than 99.99 % meanwhile permeation water conductivity was kept at a low value of $7-9{\mu}S{\cdot}cm^{-1}$ during the continuous testing for 360 h.