• Title/Summary/Keyword: Cleaning Method

Search Result 713, Processing Time 0.032 seconds

Post Sliced Cleaning of Silicon Wafers using Ozone and Ultrasound (오존과 초음파를 이용한 실리콘 웨이퍼의 Post Sliced Cleaning)

  • Choi, Eun-Suck;Bae, So-Ik
    • Korean Journal of Materials Research
    • /
    • v.16 no.2
    • /
    • pp.75-79
    • /
    • 2006
  • The effect of ozone and/or ultrasound treatments on the efficiency of slurry removal in post sliced cleaning (PSC) of silicon ingot was studied. Efficiency of slurry removal was evaluated as functions of time, temperature and surfactant with DOE (Design of Experiment) method. Residual slurries were observed on the wafer surface in case of cleaning by ozone or ultrasound separately. However, a clean wafer surface was appeared when cleaned with ozone and ultrasound simultaneously. It has found that cleaning time was the main effect among temperature, time and surfactant. Elevated temperature, addition of surfactant and high ozone concentration helped to accelerate efficient removal of slurry. The improvement of removal efficiency seems to be related to the formation of more active OH radicals. The highly cleaned surface was achieved at 10 wt% ozone, 1 min and 10 vol% surfactant with ultrasound. Application of ozone and ultrasound might be a useful method for PSC process in wafer cleaning.

Fouling and cleaning of reverse osmosis membrane applied to membrane bioreactor effluent treating textile wastewater

  • Srisukphun, Thirdpong;Chiemchaisri, Chart;Chiemchaisri, Wilai;Thanuttamavong, Monthon
    • Environmental Engineering Research
    • /
    • v.21 no.1
    • /
    • pp.45-51
    • /
    • 2016
  • Membrane bioreactor (MBR) and reverse osmosis (RO) membrane system was applied to the treatment and reclamation of textile wastewater in Thailand. An experiment was carried out to determine the fouling behavior and effect of anti-scalant and biocide addition to flux decline and its recovery through chemical cleaning. The RO unit was operated for one month after which the fouled membranes were cleaned by sequential chemical cleaning method. RO flux was found rapidly declined during initial period and only slightly decreased further in long-term operation. The main foulants were organic compounds and thus sequential cleaning using alkaline solution followed by acid solution was found to be the most effective method. The provision of anti-scalant and biocide in feed-water could not prevent deposition of foulant on the membrane surface but helped improving the membrane cleaning efficiencies.

Development of Cleaning System of Electronic Components for the Remanufacturing of Laser Copy Machine (레이저 복합기의 재제조공정을 위한 전자부품 세정시스템의 개발)

  • Bae, Jae-Heum;Chang, Yoon-Sang
    • Clean Technology
    • /
    • v.18 no.3
    • /
    • pp.287-294
    • /
    • 2012
  • In this study, performances of two cleaning methods were analyzed and a cleaning system was designed to develop a cleaning process of electronic components to remanufacture old laser copy machine. First, plasma cleaning as a dry cleaning method was executed to test cleaning ability. In cleaning of printed circuit board (PCB) by plasma, some damages were found near the metal parts, and considering the productivity, this method was not adequate for the cleaning of electronic components. With 4 different cleaning agents, ultrasonic cleaning tests were executed to select an optimal cleaning agent, aqueous agents showed superior cleaning performance compared to semi-aqueous and non-aqueous agents. Cleaning with aqueous cleaning agent A and 28 kHz ultrasonic frequency can be completed in 30 sec to 1 min. Finally, an ultrasonic cleaning system was constructed based on the pre-test results. Optimal cleaning conditions of 40 kHz and $50^{\circ}C$ were found in the field test. The productivity and economic efficiency in remanufacturing of laser copy machine are expected to increase by adapting developed ultrasonic cleaning system.

Comparison of Equipment Contamination Level according to Enteral Nutrition Bag Cleaning and Disinfection Methods (경장영양백 세척 및 소독방법에 따른 오염 정도 비교)

  • Park, Jin-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.4
    • /
    • pp.472-479
    • /
    • 2011
  • Purpose: The purpose of this study was to develop guidelines for cleaning of enteral nutrition bags by comparing the level of equipment contamination according to cleaning and disinfection methods. Method: This study was a true-experimental study, with 60 cases in total. Twenty cases each were randomly assigned to tepid water, detergent and brush, and disinfectant groups. The period of the experiment was March to April 2010, and enteral nutrition was given for 1 houre, 3 times a day at 7AM, noon, and 7PM for seven days. Enteral nutrition bags were cleaned after each feeding according to assigned cleaning and disinfection method followed by microbial cultures on 4th and 8th day before the 7AM feeding. Results: After 3 days of feeding and cleaning, the level of contamination of bags was not significantly different among the three groups. After seven days, the level of contamination was significantly lower when bags were cleaned with detergent and brush or with disinfectant compared to cleaning with tepid water. Conclusion: In cases where enteral nutrition bags are reused for example, in home care settings, studying findings indicate that cleaning bags using detergent and brush or disinfectant is an effective way to prevent contamination of bags.

Development of Motion Mechanism for Guiderail Mounting Type Window Cleaning Device (가이드레일부착형 창문청소 장치의 동작 메카니즘 개발)

  • Kim, Kyoon-tai;Jun, Young-Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.255-256
    • /
    • 2016
  • In order to overcome the limitation of conventional cleaning method by workers, variety attempts to develop a window cleaning apparatus has been tried. However, the existing cleaning devices were lack of consideration for avoiding projection parts of the window such as frames or profiles. In this study, operating mechanism of cleaning tool for avoiding the projections parts using a two-axis robot is proposed. Proposed mechanism is that a wiper are reposed in a relatively stationary in the vicinity of the projection and avoided the projection in this state. It is expected that the mechanism is the base of driving cleaning tool part in the new window cleaning apparatus.

  • PDF

Fundamental Study of the Building Exterior wall cleaning Robot using a spinning device (회전반사판을 이용한 건물 외벽청소로봇 개발방향 연구)

  • Park, Su-Yeul;Kim, Kyoon-Tai
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.224-225
    • /
    • 2013
  • Most of the building exterior wall cleaning robots use a water jet device for spraying water. However this method is sprayed excessive water usage than water quantity required for cleaning. And setting weight of the water pump cleaning device increase the weight of the building exterior wall cleaning robot. Therefor, this paper suggest that the mechanisms scatter minimal cleaning water using a spinning device of the building exterior wall cleaning robot.

  • PDF

Triangular Cell Map Based Complete Coverage Navigation Method for Cleaning Robot

  • Oh, Joon-Seop;Park, Jin-Bae;Park, Yoon-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.129.3-129
    • /
    • 2001
  • In this paper, a novel navigation method is presented for the cleaning robot in the unknown workspace. In order to do this, we propose a new map representation method and a complete coverage navigation method. First, we discuss a triangular cell map representation which makes the cleaning robot navigate with shorter path and increased flexibility than a rectangular cell map representation. Then we proposed a complete coverage navigation and map construction method which the cleaning robot can navigate the complete workspace although it has perfectly no information about environment. Finally, we evaluate the performance of our proposed triangular cell map comparing to that of the rectangular cell map via the existing ...

  • PDF

The Optimum Cleaning Process of Non-aqueous Alternative Solvents for 1,1,1-TCE (1,1,1-TCE에 대한 비수계성 대체세정제의 최적 세정공정)

  • Jung, Duck-Chae;Lee, Ki-Chang;Kong, Seung-Dae;Mok, Gab-Young;Lee, Seok-Woo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.237-240
    • /
    • 1999
  • This study showed that the optimized cleaning process using non-aqueous cleaning solvents is adaptable in the industrial field for existing 1.1.1-TCE cleaning solvents which is an ozone depleting sustance. Alternative cleaning solvent system substituted for existing cleaning solvent against non-aqueous pollutants(cutting & flux oil), was evaluated for the cleaning efficiency using gravimetric analysis method and surface change of sample by Image analyzer. The results showed that alternative solvents and process had excellent cleaning efficiency.

Quartz Megasonic System for Cleaning Flat Panel Display (평판디스플레이 세정 용 Quartz 메가소닉 시스템)

  • Kim, Hyunse;Lee, Yanglae;Lim, Euisu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.12
    • /
    • pp.1107-1113
    • /
    • 2014
  • In this article, the megasonic cleaning system for cleaning micro/nano particles from flat panel display (FPD) surfaces was developed. A piezoelectric actuator and a waveguide were designed by finite element method (FEM) analysis. The calculated peak frequency value of the quartz waveguide was 1002 kHz, which agreed well with the measured value of 1003 kHz. The average acoustic pressure of the megasonic cleaning system was 43.1 kPa, which is three times greater than that of the conventional type of 13.9 kPa. Particle removal efficiency (PRE) tests were performed, and the cleaning efficiency of the developed system was proven to be 99%. The power consumption of the developed system was 64% lower than that of the commercial system. These results show that the developed megasonic cleaning system can be an effective solution in particle removing from FPD substrate with higher energy efficiency and lower chemical and ultra pure water (UPW) consumption.

Investingation of Laser Shock Wave Cleaning with Different Particle Condition (오염 입자 상태에 따른 레이저 충격파 클리닝 특성 고찰)

  • 강영재;이종명;이상호;박진구;김태훈
    • Laser Solutions
    • /
    • v.6 no.3
    • /
    • pp.29-35
    • /
    • 2003
  • In semiconductor processing, there are two types of particle contaminated onto the wafer, i.e. dry and wet state particles. In order to evaluate the cleaning performance of laser shock wave cleaning method, the removal of 1 m sized alumina particle at different particle conditions from silicon wafer has been carried out by laser-induced shock waves. It was found that the removal efficiency by laser shock cleaning was strongly dependent on the particle condition, i.e. the removal efficiency of dry alumina particle from silicon wafer was around 97% while the efficiencies of wet alumina particle in DI water and IPA are 35% and 55% respectively. From the analysis of adhesion forces between the particle and the silicon substrate, the adhesion force of the wet particle where capillary force is dominant is much larger than that of the dry particle where Van der Waals force is dominant. As a result, it is seen that the particle in wet condition is much more difficult to remove from silicon wafer than the particle in dry condition by using physical cleaning method such as laser shock cleaning.

  • PDF