• Title/Summary/Keyword: Cleaner Technology

Search Result 205, Processing Time 0.026 seconds

Analysis on the Optimum Location of an Wet Air Cleaner in a Livestock House using CFD technology (전산유체역학 기법을 이용한 돈사 내 습식 공기 정화기의 적정 위치 설계)

  • Kwon, Kyeong-Seok;Lee, In-Bok;Hwang, Hyun-Seob;Bitog, Jessie.P.;Hong, Se-Woon;Seo, Il-Hwan;Choi, Ji-Sun;Song, Sang-Hyeon;Moon, Oun-Kyung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.3
    • /
    • pp.19-29
    • /
    • 2010
  • In South Korea, as the living standard has been getting higher, meat consumption is steadily increasing. To meet the country's demand, livestock houses become larger and wider with increased raising density. In larger livestock houses, pollutants such as flake of pig skin, excrement, odor, various dusts and noxious gas like ammonia are excessively accumulated inside the facility. These will cause weak immunity for the pigs, diminution of productivity and degeneration of working condition. These problems can be solved through the ventilation performance of the facility. In the winter time, ventilation must be controlled to minimum to maintain a suitable thermal condition. However, this affects the other internal environmental condition because of the minimum ventilation. The installation of "wet air cleaner" especially in the winter time can be an alternative solution. For efficient application of this machine, there is a need to understand the existing ventilation condition and analyze the interaction of existing ventilation system with the wet air cleaner considering its appropriate location. In this study, the existing ventilation system as well as the internal environmental condition negatively inside the facility with the wet air cleaner has been studied using CFD technology. The CFD simulation model was validated from the study conducted by Seo et al. (2008). Results show that the elimination rate of ammonia was 39.4 % and stability could be improved to 35.1 % (Comparing case 5 to 1 where wet air cleaner machine was not used). It can therefore be concluded that case 5 shows the optimum location of a wet air cleaner in the livestock house.

A study on the flexo printing wastewater treatment and recycling (Flexo 인쇄폐수의 처리 및 재활용에 관한 연구)

  • Jun, Yang-Ba;Hur, Hun;Cho, Kemin;Bae, Woo-Kun
    • Clean Technology
    • /
    • v.9 no.3
    • /
    • pp.107-113
    • /
    • 2003
  • Printing process generates a vast amount of toxical waste and wastewater by the development of printing and publishing industry. The regulations for various environmental pollution material, which were indispensably used in printing industries, were getting stronger. The printing industries should develop the cleaner technologies in order to avoid the regulations. In this paper, the separation characteristics of microfiltration, ultrafiltration, reverse osmosis were surveyed to make basic data for the optimization of process as cleaner technologies for printing industries. The $2kg/cm^2$ of operation pressure were suitable to the U/F System. Because of the permeate of U/F was below 3 NTU as turbidity, which was probed to be possible using the rinsing water in printing process. U/F System,

  • PDF

A Comparison of the PWM/PDM Control Scheme for Single Phase Switched Reluctance Motor for Vacuum Cleaner (청소기용 단상 SRM의 PWM/PDM 운전 기법 비교 고찰에 관한 연구)

  • Lee Yohan;Kim Sangyoung;Lim Junyoung;Kim Jungchul
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.419-422
    • /
    • 2002
  • This paper compares PDM and PWM for single phase switched reluctance motor for vacuum cleaner. Generally, PWM control scheme Is preferred because of small torque ripple compared with PDM control scheme. However, as the motor speed of the vacuum cleaner is above 20,000[rpm], the torque ripple is not problem any more. PDM control scheme is better than PWM control scheme considering loss of power device and EMI.

  • PDF

Effect of Suction Nozzle Modification on the Performance and Aero-acoustic Noise of a Vacuum Cleaner

  • Park, Cheol-Woo;Lee, Sang-Ik;Lee, Sang-Joon
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1648-1660
    • /
    • 2004
  • The suction nozzle of a vacuum cleaner was modified to enhance the power performance and to reduce the airflow-induced acoustic noise. The suction power efficiencies of the vacuum cleaner were measured for various nozzles; (1) original nozzle, (2) original nozzle with modified trench height, (3) original nozzle with modified connecting chamber, and (4) a combination of (2) and (3). In addition, the suction pressure and sound pressure level around the suction nozzle were measured to validate the reduction of acoustic noise. The power efficiency and mean suction pressure increased when the trench height of the suction nozzle was increased. This was attributed to the suppression of the flow separation in the suction channel. Modification of the connecting chamber in the original nozzle, which had an abrupt contraction from a rectangular chamber into a circular pipe, into a smooth converging contraction substantially improved the suction flow into the connecting pipe. When both modifications were applied simultaneously, the resulting suction nozzle was more effective from the viewpoints of aerodynamic power increase and sound pressure level reduction.

A Study on the Performance of Pipe Scale Cleaner using Natural Organic Acid (천연 유기산을 이용한 배관 스케일 세정제 성능에 관한 연구)

  • Kang, Hyung Seok;Yang, Won Suk;Kim, Young Il;Kim, Sean Hay;Choi, Dong Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.10
    • /
    • pp.530-537
    • /
    • 2017
  • Scales generated inside pipes cause negative effects on heat transfer performance, pressure loss and flow rate due to increased thermal resistance and reduced flow cross-sectional area. If these scales are not prevented or eliminated, thermal-fluid performance of the facilities can be deteriorated, or in extreme cases, accidents such as explosion due to overheating can occur. There are two ways to remove the scales, physically and chemically. Removing the scales physically needs specific machines which are expensive, and removing them chemically may provoke corrosion or shorten the age of the facilities. In this study, an eco-friendly pipe scale cleaner using natural organic acid is developed by applying the concept of a limestone cave generation. The manufactured scale cleaner is applied to remove the scales in industrial, water heating and urinal pipes. The results show that this cleaner removes scales more effectively and safely compared to existing scale treatments. Scale removal efficiencies of this work is 1.2~10.7 times for industrial pipes and 1.8~15.5 times for boiler water heating pipes higher than those of conventional cleaners.

A study regarding measurements of bacterial contamination levels in radiology room within the department of radiological technology (영상의학과 촬영실에서의 세균 오염도 측정에 관한 연구)

  • Dong, Kyung-Rae;Cho, Young-Kuk;Ro, Sang-Ho
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1150-1158
    • /
    • 2009
  • Since equipment currently being used in the department of radiological technology comes into contact with patients carrying diseases, there inevitably will be the existence of pathogenic bacteria. Therefore, in order to increase the importance of using disinfectant in hospital infection precaution and the recognition of hospital infection management, comparisons were made by measuring the bacterial contamination levels in radiology room within the department of radiological technology and comparing the measurements with post disinfection levels. Disinfecting the rooms from detected bacteria was conducted with water, tissue cleaner, or 70% alcohol. When measuring bacterial contamination levels in radiology rooms, a variety of bacteria was detected. When disinfecting the interior of radiology rooms the effectiveness of destroying bacteria and preventing hospital infection was greatest when using 70% alcohol compared to water, tissue cleaner and ventilation. Therefore, there needs to be a development of a better antiseptic for destroying bacteria because there is a possibility for hospital medical equipment to be constantly contaminated. Efforts need to be made to prevent hospital infections and patient secondary infection by disinfecting and sterilizing equipment.

  • PDF

Introduction and Analysis of Technology Roadmap (TRM) about Eco-Friendly Process in Korea (국내 친환경공정기술 분야의 기술지도 소개 및 분석)

  • Kim, Sangyong;Park, Chulhwan;Lee, Byunghwan;Lee, Sang-Hoon
    • Clean Technology
    • /
    • v.10 no.4
    • /
    • pp.189-194
    • /
    • 2004
  • The review of the present status of Korean industries and the establishment of strategic R&D agenda are necessary to improve the innovative technological capabilities of Korea to the top level of the world. Recently, Korean ministry of science and technology (MOST) has selected specific areas to develop national technological innovation system, and prepared national technology roadmap (NTRM). Korean ministry of environment (ME) also has prepared technology roadmap (TRM) to help efficient development of environmental science and technology. The development of eco-friendly process in NTRM and TRM was introduced and reviewed in this study. In addition, strength, weakness, opportunities, and threats (SWOT) analysis of technological capabilities of Korea was performed. The results propose the core role of industry, university, research institute, and government for the development of Korean environmental process technology.

  • PDF

Mass transfer characteristics of continuous electrocoagulation for dyestuff solution using aluminum flat plate electrode (Al 전극에 의한 염료의 전기응집에서 물질전달 특성)

  • Kim, Tak-Hyun;Park, Chulhwan;Shin, Eung-Bai;Kim, Sangyong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.05a
    • /
    • pp.290-291
    • /
    • 2001
  • The relationship between velocity, viscosity, diffusion coefficient, mass transfer coefficient and characteristic length and mass transfer data can be correlated by dimensionless relationship in electrolytic process. The performance of dyestuff removal was decreased as the flow rate of electrolyte was increased. It was due to the effect of retention time decreasing was superior to that of turbulent inlet mixing. Sh/Sc$\^$1/3/ vs Re plot for Al flat electrode did not showed the general tendency of the relationship between Sh/Sc$\^$1/3/ and Re. It can be thought that flow rate was not sufficiently high to increase the effect of mixing.

Effective Textile Wastewater Treatment : Pilot-Scale Study (파일롯 스케일에서의 효율적인 염색폐수 처리)

  • Park, Chulhwan;Kim, Tak-Hyun;Lee, Jinwon;Kim, Seung-Wook;Kim, Sangyong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.05a
    • /
    • pp.82-83
    • /
    • 2001
  • Selected microbes was applied to the treatment of textile wastewater with support particles. To enhance the treatment efficiency, biological treatment was achieved as first process. Wastewater with a COD of 870 ppm and color of 1340 PtCo unit was continuously treated in a 1.8 ton capacity reactor. In the case of combined processes, the effluent COD concentration and color were 40 ppm (95.4% reduction) and 20 PtCo unit (98.5% reduction).