• 제목/요약/키워드: Clean level test

검색결과 57건 처리시간 0.023초

청정화력발전 기술 육성 방안 연구 (A Study on Methods for Developing by Nurturing Clean Thermal Power Generation Technology)

  • 김영미;이원학
    • 한국기후변화학회지
    • /
    • 제9권2호
    • /
    • pp.197-207
    • /
    • 2018
  • The Korean government views coal-fired power plants as the key cause of the fine dust generation, and is developing an energy policy to replace and demolish old coal-fired power plants. According to the Eighth Power Supply Base Plan (2017-2031), the maximum power capacity in 2030 is expected to be 100.5GW, which is 17.9% higher than the current level (85.2GW). The plan aims to reduce the facility size and power generation ratio from nuclear and coal resources to even lower levels than today, and to rapidly expand power generation from new and renewable energy. Despite that, the proportion of coal power generation is still much higher than other resources, and it is expected that the reliance on goal will maintain for next several decades. Under such circumstances, the development, supply, and expansion of clean coal technology (CCT) that is eco-friendly and highly efficient, is crucial to minimize the emission of pollutants such as carbon dioxide and fine dust, as well as maximize the energy efficiency. The Korean government designated the Yong-Dong Thermoelectric Power Plant in Gangneung to develop clean coal power generation, and executed related projects for three years. The current study aims to suggest a plan to develop parts, technologies, testing, evaluation, certification, and commercialization efforts for coal-fired power generation, In addition, the study proposes a strategy to vitalize local economy and connect the development with creation of more jobs.

창공-91 실속속도 비행시험 (Flight Test of Stalling Speed for ChangGong-91)

  • 이정훈;김칠영
    • 한국항공운항학회지
    • /
    • 제16권3호
    • /
    • pp.1-6
    • /
    • 2008
  • The stalling speed flight test of light airplane, ChangGong-91, was performed to acquire the certification. With power-off engine condition, the wings level stall flight tests were conducted at the aircraft configuration of various flap angle - clean, 20degree, and full flap, respectively. They were performed considering with the combination of the maximum and minimum test weight, and forward and afterward center of gravity. The stalling speeds and the minimum speeds of light airplane were determined from the results of flight test. Also, the appropriateness of stall warning speeds are evaluated through the flight test measures. The airplane is recoverable only with pitch control and engine throttle from stall state without exceptional operation.

  • PDF

부하변동에 따른 풍력발전기용 증속기의 음향파워 특성 (Characteristics for Sound Power of Wind Turbine Gearbox by Load Variation)

  • 이재정;이승용;서영욱;이진현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.311-315
    • /
    • 2012
  • In these days, promising renewable energy, wind turbine is clean energy but has an environmental pollutant which is noise. Noise assessment is one of the major performance evaluations for wind turbine and nowadays, developing and research for measurement and method of the assessment considering environmental pollutants is being important. Object in this study is that figuring out sound power characteristic of the gearbox for wind turbine through measuring sound intensity. In back-to-back test, we can figure out the noise characteristic of the gearbox for wind turbine through comparing and measuring sound pressure level, sound power level in operating at the each load condition respectively.

  • PDF

진여클린미스트를 이용한 중년여성의 안면피부개선 효과 (Effects of Jinyeosoo Clean Mist on the Improvement of Facial Skin in Middle-aged Women)

  • 김민주
    • 융합정보논문지
    • /
    • 제11권3호
    • /
    • pp.220-228
    • /
    • 2021
  • 본 연구에서는 2020년 10월12일부터 2020년 11월15까지 35~55세의 중년여성 20여명을 대상으로 연구하였다. 실험군에는 진여수클린미스트를 사용하도록 하였고, 대조군 10명의 여성들에게는 평소 사용하는 이온수 성분을 함유하지 않은 미스트제품을 사용하도록 설계하였다. 실험에 사용된 Janus 안면진단기(주. 피에스아이)로 피부에 조사하여 광원의 차이에 따라 관찰 되는 모공, 주름, 탄력, UV색소침착, 색소침착, 피부톤을 측정하였다. 실험전 클렌징을 하고 10분간 안정한 뒤 안면진단기로 촬영을 하였고, 진여수클린미스트 사용 후 7일에 1회씩 총 4회 촬영이 진행되었다. 통계처리는 SPSS 통계프로그램 21.0을 활용하여 실험에 참여한 두 집단 간 실험 전 데이터와 실험 후 데이터의 평균을 비교하기 위해 대응표본 t-test를 사용하였다. 야누스III의 데이터 분석자료에서 분석수치는 평균연령의 데이터를 기본값으로 하였으며 0(zoro)에서 숫자가 증가할수록 나이에 비해 개선이 요구된다. 분석결과, 진여수이클린미스트 제품을 사용한 집단에서 모공(t=3.280, p<.01), 주름((t=4.353, p<.01), 탄력(t=3.003, p<.05), 피부톤(t=3.280, p<.01)에서 통계적 유의수준 하에서 차이가 있는 것으로 나타났다. 반면 색소침착과 UV색소침착과 피부톤은 통계적으로 유의하지 않은 것으로 분석되었다.

공기청정기 CA 규격성능시험 결과 분석 및 가스시험 변별력 향상 방안연구 (Analysis of CA Certification Performance Test Results and Improvement of CA Test Method for a Better Differentiation of Gas Removal Performances for Room Air Cleaners)

  • 김학준;한방우;김용진;차성일
    • 한국입자에어로졸학회지
    • /
    • 제7권3호
    • /
    • pp.87-97
    • /
    • 2011
  • In this study, we organized the test results obtained from the performance tests for the CA certificated air cleaners which had been commercially available in Korea since 2003, and analyzed the correlation among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level etc. The noise level of 267 air cleaners were increased as concentrated at the 45, 50, 55 dB, which are the required noise level for CA certification according to flow rate, and ozone emissions from the CA air cleaners were significantly lower than the requirement limit, 50 ppb for 24 hour operation. The average particle collection efficiency and odor removal efficiency were 89.3 and 80.8%, approximately 20% higher than the requirement of CA certification, regardless of flow rates. The particle removal performance of an air cleaner was clearly discriminated by its CADR, and the CADR was obtained with a simple calculation: 0.79 x flow rate. The low differentiation of gas removal performance of air cleaners by the current CA gas test method was improved by 3.2, 751.3, 13.4 times for ammonia, acetic acid, respectively, by adopting the CADR concept and the real time measurement method, FTIR, for gas removal performance test.

옥외 애자용 재료의 표면 전기전도특성 (Properties of Surface Electrical Conduction in Materials for Outdoor Insulator)

  • 박영국;강성화;정수현;이운석;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.207-210
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition. The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

Adsorptive Desulfurization of Diesel for Fuel Cell Applications: A Screening Test

  • Ho, Hoang Phuoc;Kim, Woo Hyeong;Lee, So-Yun;Son, Hong-Rok;Kim, Nak Hyeon;Kim, Jae-Kon;Park, Jo-Yong;Woo, Hee Chul
    • 청정기술
    • /
    • 제20권1호
    • /
    • pp.88-94
    • /
    • 2014
  • 경유는 연료전지 시스템의 연료원으로써 주목받고 있는 탄화수소 액체연료 중 하나로, 연료개질 촉매와 연료전지의 전극재료를 피독시키는 황화합물을 포함하고 있어 탈황공정이 필요한 것으로 여겨지고 있다. 다양하고도 대안적인 탈황기술이 연구되고 있으나, 초저유황 경유의 탈황 연구는 여전히 부진한 실정이다. 본 연구는 용융탄산염 연료전지 시스템에 응용될 수 있는 원료인 상용초저유황 경유의 탈황에 관한 것이다. 여기서 초저유황의 흡착탈황을 위한 흡착제로 활성탄, 제올라이트, 금속산화물 계 상용흡착제 후보군이 선정되었고 유망한 탈황제를 찾기 위한 스크리닝 평가를 실시하였다. 그 결과 초저유황 경유의 황농도를 0.1 ppmw 수준까지 떨어뜨리기 위한 흡착제 종류로 금속산화물계가 매우 유용하며, 활성탄과 제올라이트 흡착제는 같은 실험조건에서 해당 수준의 황 농도에 이르지 못하는 것으로 나타났다.

경유차 매연저감장치에 의해 비활성화된 DOC촉매의 재제조 효과에 관한 연구 (A Study on the Effectiveness of Remanufacturing Technology for the Diesel Oxidation Catalyst(DOC) Deactivated by Diesel Exhaust Gas)

  • 박해경
    • 청정기술
    • /
    • 제16권4호
    • /
    • pp.265-271
    • /
    • 2010
  • 경유차 매연저감장치에서 비활성화된 디젤산화촉매(DOC)를 대상으로 여러 가지 조건에서 재제조한 후, 재제조된 DOC의 일산화탄소(CO)와 탄화수소화합물(THC)의 저감효율과 촉매물성 특성을 분석하여 비활성화된 DOC 촉매에 대한 재제조 효과를 관찰하였다. 재제조된 DOC촉매에 대한 오염물질 저감성능 평가는 디젤엔진 다이나모 장치를 이용, 배기가스를 일부 우회시켜 온도와 공간속도조절이 가능한 촉매반응장치로 수행하였으며, 촉매물성 분석은 광학현미경, EDX, ICP, TGA 그리고 porosimeter를 이용하였다. 연구수행 결과 비활성화된 DOC 촉매를 본 연구에서 적용된 고온배소세정, 산성/염기성용액에 의한 초음파세정, 세정 후 촉매활성성분 재함침에 의한 재제조를 수행할 경우, 재제조된 DOC 촉매의 성능이 신품 성능의 90% 이상으로 회복되는 것을 확인하였으며, 광학현미경, EDX, TGA와 ICP등의 분석을 통해 본 연구조건에서의 재제조 과정으로, 촉매의 활성 저하 원인이 되었던 각종 불순 성분 대부분이 비활성화된 DOC 촉매로부터 제거되는 것을 확인하였다.

산후조리원 이용 산모의 산후조리 인지도와 수행도 (A Study on the Level of Recognition & Performance of Traditional Postpartal Care for postpartal Women in Postpartum Care Center)

  • 박심훈;김현옥
    • 여성건강간호학회지
    • /
    • 제8권4호
    • /
    • pp.506-520
    • /
    • 2002
  • The purpose of this study is to research the degree of recognition & performance of traditional postpartal care for postpartal women and to provide the basic data for improvement of service in a postpartum care center. The respondents of this study were 100 women of 6 postpartum care centers within a C province from Oct. 20 to Dec. 10, 2000. The instruments of measure were used for collecting data on the degree of recognition & performance of traditional postpartal care developed by the researcher. Data analysis consisted of frequency, percentage, mean, standard deviation, paired t-test, t-test, ANOVA which are calculated by Scheffe test and Cronbach's alpha which is used as a reliance level by using a SPSS-PC+. The results of the study were as follows:1. The average score for the degree of recognition of traditional postpartal care(Sanhujori) for postpartal women was $3.09{\pm}.31$, and they recognized that it was important. The methods which were ranked were as follows; Protecting the body from a harmful state, invigorating the body by the argumentation of heat and avoidance of cold, handling with whole heart, and keeping clean, resting without working, eating well. 2. The average score for the degree of performance of traditional postpartal care (Sanhujori) for postpartal women was $2.81{\pm}.31$, and they performed that it was important, too. The methods which were ranked were as follows; Protecting the body from a harmful state, invigorating the body by the augumentation of heat and avoidance of cold, eating well, handling with whole heart, and keeping clean, resting without working. 3. There were significant differences statistically (paired-t=-8.39, p=.000) of the degree of recognition & performance of traditional postpartal care(Sanhujori) for the postpartal women. The degree of recognition was higher than the degree of performance. So, the recognition of traditional postpartal care (Sanhujori) was higher than the performance of it. 4. There were no statistical differences of the degree of recognition & performance of traditional postpartal care(Sanhujori) among the postpartal women's age, religion, job, educational background, delivery frequency, delivery method or the sex of baby. So, the Characteristics of the respondents were not influenced as far as the degree of recognition & performance of traditional postpartal care(Sanhujori). 5. There were significant differences statistically of the degree of performance of traditional postpartal care(Sanhujori) among the 5 postpartum care centers except 1 postpartum care center(p<.01). So, the recognition of traditional postpartal care(Sanhujori) was higher than the performance of traditional postpartal care(Sanhujori) in the 5 postpartum care centers. But there was performed as good as recognition in only 1 postpartum care center.

  • PDF

연직배수재(VDs)에 의한 오염지반정화 메커니즘 연구 (Mechanism of Soil Remediation in Contaminated Area Using Vertical Drains)

  • 이행우;장병욱;강병윤;김현태
    • 한국농공학회논문집
    • /
    • 제47권5호
    • /
    • pp.63-71
    • /
    • 2005
  • In-situ soil remediation mechanism through the vertical drains (VDs) is analyzed with numerical model as the error and complementary error function. Results from in-situ test and analysis indicate that the contaminant concentration ratio as initial one ( C/$C_0$) increases as the radius ratio ( r/R) increases from the injection well, and also increases as the depth ratio ( z/ H) increases from the top of contaminated area. The elapse time needed to attain $50\%$ and $90\%$ clean up level ($ t_{50},\;t_{90}$) increases as the radius ratio ( r/R) and the depth ratio ( z/ H) increase. As above results, the procedure of soil flushing in contaminated area using vertical drains makes progress from the top of injection well to the bottom of extraction well.