• Title/Summary/Keyword: Clean combustion

Search Result 266, Processing Time 0.028 seconds

Effect of pressure and stochiometric air ratio on flame structure and NOx emission in gas turbine dump combustor with double cone burner (이중원추형 모형연소기에서 압력과 공기비에 따른 화염 구조 및 NOx 배출특성)

  • Nam, Hyun Su;Han, Dong Sik;Kim, Gyu Bo;Jeo, Chung-Hwan
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.177-179
    • /
    • 2012
  • This work presents an experimental investigation to study $NO_x$ emissions under stoichiometric air ratio and elevated pressure (2~10bar) in a High Press Combustor(HPC) equiped with double cone burner which was designed by Pusan Clean Coal Center(PC3). Exaust gas temperature and $NO_x$ emissions were measured at the end of the combustion chamber. The $OH^*$ radical concentration and $NO_x$ emission were decreased as a function of increasing ${\lambda}$ generally. On the other hand, $OH^*$ radical concentration and $NO_x$ emission increased with ${\lambda}$ pressure of the combustion chamber. $NO_x$ emissions which were governed by thermal $NO_x$, were highly increased under the elevated pressure, but slightly increased at sufficiently low fuel concentrations (${\lambda}>2.0$).

  • PDF

A Study on the Reclamation of the Furan Sand by the Fluidized Bed (유동층을 이용한 주물사의 재생에 관한 연구)

  • Baek, Ko-Kil;Choi, Yang-Jin
    • Journal of Korea Foundry Society
    • /
    • v.12 no.6
    • /
    • pp.471-479
    • /
    • 1992
  • For the last 2 decades, the bonding materials for the foundry sand and the foundry equipments with high performance have been developed and employed in the foundry shops. In those periods, the furan resins hardened in higher temperature have been replaced with the self-hardened ones in the room temperature. Simultaneously the various reclamation methods of the self-hardened furan resin sand have been developed in order to get the clean working environments, the reduction of solid wastes and the lower of production cost in the foundry. In this experimental study, the combustion reclamation method using the fluidized bed among the various methods was studied in order to reduce the L.O.I. and /or $N_2$ gas due to the deposition of the furan resins and the hardeners. Comparing the results of this experimental combustion reclamation method with those of the employed pneumatic method, the Surface Stability Index of the specimen made by combustion method is 30% higher than that of the latter one and L.O.I. decreases about 30%. The reclamation temperature of 650$^{\circ}C$ in this experimental fluidized bed would be recommended in the viewpoints of the reclamation period, the fuel consumption and the residual quantity of the furan resin. The formula determining the minimum fluidizing velocities according to the temperatures in the fluidized bed has been obtained.

  • PDF

Characteristics of Flue Gas Using Direct Combustion of VOC and Ammonia (휘발성 유기 화합물 및 암모니아 직접 연소를 통한 배기가스 특성)

  • Kim, JongSu;Choi, SeukCheun;Jeong, SooHwa;Mock, ChinSung;Kim, DooBoem
    • Clean Technology
    • /
    • v.28 no.2
    • /
    • pp.131-137
    • /
    • 2022
  • The semiconductor process currently emits various by-products and unused gases. Emissions containing pollutants are generally classified into categories such as organic, acid, alkali, thermal, and cabinet exhaust. They are discharged after treatment in an atmospheric prevention facility suitable for each exhaust type. The main components of organic exhaust are volatile organic compounds (VOC), which is a generic term for oxygen-containing hydrocarbons, sulfur-containing hydrocarbons, and volatile hydrocarbons, while the main components of alkali exhaust include ammonia and tetramethylammonium hydroxide. The purpose of this study was to determine the combustion characteristics and analyze the NOX reduction rate by maintaining a direct combustion and temperature to process organic and alkaline exhaust gases simultaneously. Acetone, isopropyl alcohol (IPA), and propylene glycol methyl ether acetate (PGMEA) were used as VOCs and ammonia was used as an alkali exhaust material. Independent and VOC-ammonia mixture combustion tests were conducted for each material. The combustion tests for the VOCs confirmed that complete combustion occurred at an equivalence ratio of 1.4. In the ammonia combustion test, the NOX concentration decreased at a lower equivalence ratio. In the co-combustion of VOC and ammonia, NO was dominant in the NOX emission while NO2 was detected at approximately 10 ppm. Overall, the concentration of nitrogen oxide decreased due to the activation of the oxidation reaction as the reaction temperature increased. On the other hand, the concentration of carbon dioxide increased. Flameless combustion with an electric heat source achieved successful combustion of VOC and ammonia. This technology is expected to have advantages in cost and compactness compared to existing organic and alkaline treatment systems applied separately.

Study on Tar Reforming by Using the Catalyst Derived from Wastes (폐기물유래 촉매를 이용한 타르 개질에 관한 연구)

  • Sung, Hojin;Nam, Sungbang;Pakr, Yeongsu;Gu, Jaehoi
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.267-270
    • /
    • 2014
  • Since contaminants of syngas obtained from the biomass gasification are removed, the syngas is clean fuel. In this study a high-efficiency energy production system is developed. The system produces electricity using a waste pressure and feeds a low-pressure steam to Dyeing industrial complex. Also, iron oxide derived from dyeing sludge is utilized as a self-catalyst to reform a tar and reduce a tar emission from gasifier. This system increases the amount of syngas and finally achieves a highly efficient gasification.

  • PDF

STUDY OF MERCURY KINETICS AND CONTROL METHODOLOGIES IN SIMULATED COMBUSTION FLUE GASES (연소장치에서의 수은의 화학물리적 특성에 관한 연구와 발생 및 배출의 최소화 기술 개발)

  • 이태규
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.103-108
    • /
    • 2001
  • 각종 연소기반의 오염 배출원에서의 수은을 비롯한 중금속의 배출은 많은 우려를 낳고있다. 이미 미국에서는 1990년 Clean Air Act Amendments를 통해 11개의 중금속의 (As, Be, Cd, Co, Cr, Hg, Mn, Ni, Pb, Sb, and Se) 배출을 가장 효과적인 적용 가능한 기술로서 그 배출을 제어하도록 되어있다. 그 중에서도 특히 수은은 다른 중금속과는 달리 높은 휘발성, 강한 유해성, 그리고 체내에 축적이 되는 특성으로 해서 더욱 관심의 대상이 되고 있다. 또한 수은은 연소장치에서 대기중으로 배출시 다른 중금속이 입자의 형태로 배출되는 것과는 달리 주로 원소상태의 기체로 배출되는 것으로 알려져 있다. (중략)

  • PDF

Acid Functionalized Poly(arylene ether)s for Proton-conducting Membranes

  • Shin, Chong-Kyu;Gerhard Maier;Gunther G. Scherer
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.70-73
    • /
    • 2004
  • Fuel Cells are clean and efficient electrochemical devices that convert the chemical energy stored in a fuel with oxygen from air directly into usable electricity without using a conventional combustion process. Because of the great importance of proton conducting membranes in fuel cells for certain applications as mobile power generators, significant research efforts have been devoted to these membranes during the last 30 years.(omitted)

  • PDF

Combustion Characteristics and Durability of Diesel Engines Burning BDF 20 (BDF 20을 사용하는 디젤기관들의 연소 및 내구특성)

  • Ryu, Kyung-Hyun;Oh, Young-Taig
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.18-28
    • /
    • 2007
  • Three diesel engines were fueled with BDF 20, a blend of 80% diesel fuel and 20% biodiesel fuel by volume, and run in excess of 200 h to evaluate their combustion characteristics and durability. The engines used for this study were a 4-cylinder 2476-cc displacement IDI diesel engine(Engine 1), a 4-cylinder l732-cc displacement IDI diesel engine(Engine 2), and a single cylinder 673-cc displacement DI diesel engine(Engine 3). Engine dynamometer testing was performed on each engine at regularly scheduled intervals to monitor the performance and exhaust emissions, which were sampled at 1h intervals for analysis, The peak combustion pressure with BDF 20 increased in Engines 1 and 3 over that measured when burning pure diesel fuel, but that in Engine 2 remained constant. Combustion parameters, such as the maximum combustion pressure and corresponding crank angle, did not change over the long-term dynamometer testing. The BSFC with BDF 20 in Engine 1 was less than that measured with pure diesel fuel. The amount of smoke produced with BDF 20 was less for all engines ; the greatest reduction was observed for Engine 3. The NOx emissions were lower in the IDI engines than the DI engine. The traditional trade-off between smoke and NOx emissions was maintained for BDF 20 fuel for Engines 1 and 3. There was not a big difference in the $CO_2\;and\;O_2$ emissions for BDF 20, as compared to pure diesel fuel, but more $CO_2$ was exhausted by Engine 1 than by Engines 2 or 3 and less $O_2$ was exhausted by Engine 1 than by Engines 2 or 3. The engine parts remained clean, except for some carbon attached to the area surrounding the nozzle hole of the DI diesel engine.

A Study on the Oxy-Combustion of the Coal in Drop Tube Furnace (Drop Tube Furnace에서 석탄의 순산소 연소 특성)

  • Roh, Seon Ah;Yun, Jin Han;Lee, Jung Kyu;Keel, Sang In;Min, Tai Jin;Kim, Sang-Bok;Park, In-Yong;Han, Bangwoo;Kim, Jin-Tae
    • Clean Technology
    • /
    • v.27 no.4
    • /
    • pp.367-371
    • /
    • 2021
  • The oxy-combustion system is one of the carbon recovery and storage technologies (CCS: Carbon capture & storage) that performs coal combustion using pure oxygen and recirculated flue gas. This is a technology that facilitates storage of carbon dioxide by generating an exhaust gas consisting of only carbon dioxide without a process of separating carbon dioxide and nitrogen when coal is burned using pure oxygen and recirculated flue gas mixture instead of a conventional air combustion system that produces carbon dioxide and nitrogen mixed exhaust gas. In this study, the characteristics of generated NO and SO2 as atmospheric pollutants during oxy-combustion were examined using O2/CO2 mixed simulation gas. The reaction temperature was varied from 900 ℃ to 1200 ℃ and oxygen partial pressure was varied from 30% to 50%. The results showed that NO and SO2 concentrations in flue gas increased as the oxygen concentration and the reaction temperature in the furnace increased. The partial pressure of CO2 in flue gas also increased as the oxygen concentration and the reaction temperature in the furnace increased. As a results of comparing NO production of 30% O2/CO2 oxy-combustion with air combustion, NO in flue gas increased with reaction temperature in both experiments and NO of oxy-combustion was 40 ~ 80 ppm lower than that of air combustion.

Effect of AC Electric Fields on Flow Instability in Laminar Jets (층류제트유동 불안정성에 미치는 교류 전기장 효과)

  • Kim, Gyeong Taek;Lee, Won June;Cha, Min Suk;Park, Jeong;Chung, Suk Ho;Kwon, Oh Boong;Kim, Min Kuk;Lee, Sang Min
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.3
    • /
    • pp.1-6
    • /
    • 2016
  • The effect of applied electric fields on jet flow instability was investigated experimentally by varying the direct current (DC) voltage and the alternating current (AC) frequency and voltage applied to a jet nozzle. We aimed to elucidate the origin of the occurrence of twin-lifted jet flames in laminar jet flow configuration, which occur when AC electric fields are applied. The results indicate that a twin-lifted jet flames originates from cold jet instability, caused by interactions between negative ions in the jet flow via electron attachment as $O_2+e{\rightarrow}O_2{^-}$ when AC electric fields are applied. This was confirmed by experiments in which a variety of gaseous jets were ejected from a nozzle to which DC voltages and AC frequencies and voltages were applied, with ambient air between two deflection plates connected to a DC power source. Experiments in which jet flows of several gases were ejected from a nozzle and AC electric fields were applied in coflow-nitrogen provided further evidence. The flow instability occurred only for oxygen and air jets. Additionally, jet instability occurred when the applied frequency was less than 80 Hz, corresponding to the characteristic collision response time. The effect of AC electric fields on the overall structure of the jet flows is also reported. Based on these results, we propose a mechanism to reduce jet flow instability when AC electric fields are applied to the nozzle.

Numerical Study of Combustion Characteristics by Pressure and Oxygen Concentration in Counter-Flow Diffusion Flame Model (대향류 확산 화염 모델에서의 압력 및 산소분율에 따른 연소 특성 변화에 관한 수치해석 연구)

  • Park, Jinje;Lee, Youngjae
    • Clean Technology
    • /
    • v.27 no.1
    • /
    • pp.93-103
    • /
    • 2021
  • As the seriousness and necessity of responding to climate change and reducing carbon emissions increases, countries around the world are continuing their efforts to reduce greenhouse gases. Among various efforts, research on CCUS, capturing and utilizing carbon dioxide generated when using carbon-based fuels, is actively being conducted. Studies on pressurized oxy-fuel combustion (POFC) that can be used with CCUS are also being conducted by many researchers. The purpose of this study is to analyze basic information related to the flame structure and pollutant emissions of pressurized oxy-fuel combustion. For this, a counter-flow diffusion flame model was used to analyze the combustion characteristics according to pressure and oxygen concentration. As the pressure increased, the flame temperature increased and the flame thickness decreased due to a reaction rate improvement caused by the activation of the chemical reaction. As oxygen concentration increased, both the flame temperature and the flame thickness increased due to an improvement to the reaction rate and diffusion because of a change in oxidizer momentum. Analyzing the related heat release reaction by dividing it into three sections as the oxygen concentration increased showed that the chemical reaction from the oxidizer side was subdivided into two regions according to the mixture fraction. In addition, the emission index of NO classified according to the NO formation mechanism was analyzed. The formation trend of NO according to each analysis condition was presented.