• Title/Summary/Keyword: Civil Engineering Site

Search Result 1,926, Processing Time 0.034 seconds

A Study on the Construction Process of the Garden in 'Unbo's House' Focused on the Individual Relationship (인물관계로 본 '운보의 집' 정원의 조영과정)

  • Shin, Hyun-Sil
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.36 no.3
    • /
    • pp.149-159
    • /
    • 2018
  • The study is aimed at establishing basic data to identify the original forms of the garden in Unbo's House. Through interviews and related data comparison analysis the ideas and major events of the person involved in establishing a garden in Unbo's House. Also, derived the direct and indirect effects of these people on gardening. The results are as follows: First, Those directly related to garden in Unbo's House are representative figures of cultural heritage and traditional art in Korea. Based on their expertise and abundant experience in traditional spaces, they contributed greatly to the creation of Unbo's House as a traditional space. Unbo Kim, Gi-Chang who directly influenced Unbo's House gardening, which affected the site selection, location, and the installation of major garden plant plants and traditional landscaping facilities. Hyegok Choi, Soon-Woo recommended Wabon Kim, Dong-Hyun at the request of Kim Ki-Chang and was involved in the overall plan. Housing design, space design and design of major facilities such as pond were confirmed Wabon Kim Dong-Hyun. Second, Kim, Gi-Chang's wife Jeong, Rae-Hyun, who motived to construct a garden. Nosan Lee, Eun-Sang and Korean artist Lee, Seok-Ho were created a signboard and board of the Pillar to encourage simple life in paintings. The themes of the article motived image as creative. In addition, Kim, Hyeong-Sik and Kim, Wan who son of Unbo, has been with Unbo for a long time, watching and influencing garden changes in Unbo's House. Third, The main factors that influenced the garden by character are as follows. Unbo Kim, Ki-Chang had a thorough record-setting spirit and his longing for his mother and wife affected the selection of the site and setting the direction of the garden. His art world with the symbolic emphasis of traditional landscapes, including traditional facilities, and especially plant materials. Choi, Sun-Woo reflected his traditional consciousness and experience in the construction of Unbo's House. Kim, Dong-Hyun applied the basic framework of a traditional building based on Yeonkyongdang hall in Changdeokgung palace. He also reflected on the traditional landscaping design the facilities of ponds acquired through excavation of Donggung Palace and Wolji Pond, Gyeongju. Nosan Lee, Eun-Sang and Lee, Seok-Ho completed their unique place in Unbo's House. Kim, Hyung-Sik was involved in the process of changing, while Kim Wan ran the Unbo's House which he inherited from Kim, Ki-Chang.

An Analytical Study on the Seismic Behavior and Safety of Vertical Hydrogen Storage Vessels Under the Earthquakes (지진 시 수직형 수소 저장용기의 거동 특성 분석 및 안전성에 관한 해석적 연구)

  • Sang-Moon Lee;Young-Jun Bae;Woo-Young Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.152-161
    • /
    • 2023
  • In general, large-capacity hydrogen storage vessels, typically in the form of vertical cylindrical vessels, are constructed using steel materials. These vessels are anchored to foundation slabs that are specially designed to suit the environmental conditions. This anchoring method involves pre-installed anchors on top of the concrete foundation slab. However, it's important to note that such a design can result in concentrated stresses at the anchoring points when external forces, such as seismic events, are at play. This may lead to potential structural damage due to anchor and concrete damage. For this reason, in this study, it selected an vertical hydrogen storage vessel based on site observations and created a 3D finite element model. Artificial seismic motions made following the procedures specified in ICC-ES AC 156, as well as domestic recorded earthquakes with a magnitude greater than 5.0, were applied to analyze the structural behavior and performance of the target structures. Conducting experiments on a structure built to actual scale would be ideal, but due to practical constraints, it proved challenging to execute. Therefore, it opted for an analytical approach to assess the safety of the target structure. Regarding the structural response characteristics, the acceleration induced by seismic motion was observed to amplify by approximately ten times compared to the input seismic motions. Additionally, there was a tendency for a decrease in amplification as the response acceleration was transmitted to the point where the centre of gravity is located. For the vulnerable components, specifically the sub-system (support columns and anchorages), the stress levels were found to satisfy the allowable stress criteria. However, the concrete's tensile strength exhibited only about a 5% margin of safety compared to the allowable stress. This indicates the need for mitigation strategies in addressing these concerns. Based on the research findings presented in this paper, it is anticipated that predictable load information for the design of storage vessels required for future shaking table tests will be provided.

Using Transportation Card Data to Analyze City Bus Use in the Ulsan Metropolitan City Area (교통카드를 활용한 시내버스의 현황 분석에 관한 연구 - 울산광역시 사례를 중심으로 -)

  • Choi, Yang-won;Kim, Ik-Ki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.603-611
    • /
    • 2020
  • This study collected and analyzed transportation card data in order to better understand the operation and usage of city buses in Ulsan Metropolitan City in Korea. The analysis used quantitative and qualitative indicators according to the characteristics of the data, and also the categories were classified as general status, operational status, and satisfaction. The existing city bus survey method has limitations in terms of survey scale and in the survey process itself, which incurs various types of errors as well as requiring a lot of time and money to conduct. In particular, the bus means indicators calculated using transportation card data were analyzed to compensate for the shortcomings of the existing operational status survey methods that rely entirely on site surveys. The city bus index calculated by using the transportation card data involves quantitative operation status data related to the user, and this results in the advantage of being able to conduct a complete survey without any data loss in the data collection process. We took the transportation card data from the entire city bus network of Ulsan Metropolitan City on Wednesday April 3, 2019. The data included information about passenger numbers/types, bus types, bus stops, branches, bus operators, transfer information, and so on. From the data analysis, it was found that a total of 234,477 people used the city bus on the one day, of whom 88.6% were adults and 11.4% were students. In addition, the stop with the most passengers boarding and alighting was Industrial Tower (10,861 people), A total of 20,909 passengers got on and off during the peak evening period of 5 PM to 7 PM, and 13,903 passengers got on and off the No. 401 bus route. In addition, the top 26 routes in terms of the highest number of passengers occupied 50% of the total passengers, and the top five bus companies carried more than 70% of passengers, while 62.46% of the total routes carried less than 500 passengers per day. Overall, it can be said that this study has great significance in that it confirmed the possibility of replacing the existing survey method by analyzing city bus use by using transportation card data for Ulsan Metropolitan City. However, due to limitations in the collection of available data, analysis was performed only on one matched data, attempts to analyze time series data were not made, and the scope of analysis was limited because of not considering a methodology for efficiently analyzing large amounts of real-time data.

Assessing the Sensitivity of Runoff Projections Under Precipitation and Temperature Variability Using IHACRES and GR4J Lumped Runoff-Rainfall Models (집중형 모형 IHACRES와 GR4J를 이용한 강수 및 기온 변동성에 대한 유출 해석 민감도 평가)

  • Woo, Dong Kook;Jo, Jihyeon;Kang, Boosik;Lee, Songhee;Lee, Garim;Noh, Seong Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.43-54
    • /
    • 2023
  • Due to climate change, drought and flood occurrences have been increasing. Accurate projections of watershed discharges are imperative to effectively manage natural disasters caused by climate change. However, climate change and hydrological model uncertainty can lead to imprecise analysis. To address this issues, we used two lumped models, IHACRES and GR4J, to compare and analyze the changes in discharges under climate stress scenarios. The Hapcheon and Seomjingang dam basins were the study site, and the Nash-Sutcliffe efficiency (NSE) and the Kling-Gupta efficiency (KGE) were used for parameter optimizations. Twenty years of discharge, precipitation, and temperature (1995-2014) data were used and divided into training and testing data sets with a 70/30 split. The accuracies of the modeled results were relatively high during the training and testing periods (NSE>0.74, KGE>0.75), indicating that both models could reproduce the previously observed discharges. To explore the impacts of climate change on modeled discharges, we developed climate stress scenarios by changing precipitation from -50 % to +50 % by 1 % and temperature from 0 ℃ to 8 ℃ by 0.1 ℃ based on two decades of weather data, which resulted in 8,181 climate stress scenarios. We analyzed the yearly maximum, abundant, and ordinary discharges projected by the two lumped models. We found that the trends of the maximum and abundant discharges modeled by IHACRES and GR4J became pronounced as changes in precipitation and temperature increased. The opposite was true for the case of ordinary water levels. Our study demonstrated that the quantitative evaluations of the model uncertainty were important to reduce the impacts of climate change on water resources.

Effectiveness Analysis of HOT Lane and Application Scheme for Korean Environment (HOT차로 운영에 대한 효과분석 및 국내활용방안)

  • Choi, Kee Choo;Kim, Jin Howan;Oh, Seung Hwoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1D
    • /
    • pp.25-32
    • /
    • 2009
  • Currently, various types of TDM (Transportation Demand Management) policies are being studied and implemented in an attempt to overcome the limitations of supply oriented policies. In this context, this paper addressed issues of effectiveness and possible domestic implementation of the HOT lane. The possible site of implementation selected for this simulation study is part of the Kyung-bu freeway, where a dedicated bus lane is currently being operated. Minimum length of distance required in between interchanges and access points of the HOT lane for vehicles to safely enter and exit the lane, and traffic management policies for effectively managing the weaving traffic trying to enter and exit the HOT lane were presented. A 5.2km section of freeway from Ki-heuing IC to Suwon IC and a 8.3km section from Hak-uei JC to Pan-gyo JC have been selected as possible sites of implementation for the HOT lane, in which congestion occurs regularly due to the high level of travel demand. VISSIM simulation program has been used to analyze the effects of the HOT lane under the assumption that one-lane HOT lane has been put into operation in these sections and that the lane change rate were in between 5% to 30%. The results of each possible scenario have proven that overall travel speed on the general lanes have increased as well by 1.57~2.62km/h after the implementation of the HOT lane. It is meaningful that this study could serve as a basic reference data for possible follow-up studies on the HOT lane as one effective method of TDM policies. Considering that the bus travel rate would continue increase and assuming the improvement in travel speed on general lanes, similar case study can be implemented where gaps between buses on bus lane are available, as a possible alternative of efficient bus lane management policies.

Comparison of Direct and Indirect $CO_2$ Emission in Provincial and Metropolitan City Governments in Korea: Focused on Energy Consumption (우리나라 광역지방자치단체의 직접 및 간접 $CO_2$ 배출량의 비교 연구: 에너지 부문을 중심으로)

  • Kim, Jun-Beum;Chung, Jin-Wook;Suh, Sang-Won;Kim, Sang-Hyoun;Park, Hung-Suck
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.12
    • /
    • pp.874-885
    • /
    • 2011
  • In this study, the urban $CO_2$ emission based on energy consumption (Coal, Petroleum, Electricity, and City Gas) in 16 provincial and metropolitan city governments in South Korea was evaluated. For calculation of the urban $CO_2$ emission, direct and indirect emissions were considered. Direct emissions refer to generation of greenhouse gas (GHG) on-site from the energy consumption. Indirect emissions refer to the use of resources or goods that discharge GHG emissions during energy production. The total GHG emission was 497,083 thousand ton $CO_2eq.$ in 2007. In the indirect GHG emission, about 240,388 thousand ton $CO_2eq.$ was occurred, as 48% of total GHG emission. About 256,694 thousand ton $CO_2eq.$ (52% of total GHG emissions) was produced in the direct GHG emission. This amount shows 13% difference with 439,698 thousand ton $CO_2eq.$ which is total national GHG emission data using current calculation method. Local metropolitan governments have to try to get accuracy and reliability for quantifying their GHG emission. Therefore, it is necessary to develop and use Korean emission factors than using the IPCC (Intergovernmental Panel on Climate Change) emission factors. The method considering indirect and direct GHG emission, which is suggested in this study, should be considered and compared with previous studies.

Modelling of Fault Deformation Induced by Fluid Injection using Hydro-Mechanical Coupled 3D Particle Flow Code: DECOVALEX-2019 Task B (수리역학적연계 3차원 입자유동코드를 사용한 유체주입에 의한 단층변형 모델링: DECOVALEX-2019 Task B)

  • Yoon, Jeoung Seok;Zhou, Jian
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.320-334
    • /
    • 2020
  • This study presents an application of hydro-mechanical coupled Particle Flow Code 3D (PFC3D) to simulation of fluid injection induced fault slip experiment conducted in Mont Terri Switzerland as a part of a task in an international research project DECOVALEX-2019. We also aimed as identifying the current limitations of the modelling method and issues for further development. A fluid flow algorithm was developed and implemented in a 3D pore-pipe network model in a 3D bonded particle assembly using PFC3D v5, and was applied to Mont Terri Step 2 minor fault activation experiment. The simulated results showed that the injected fluid migrates through the permeable fault zone and induces fault deformation, demonstrating a full hydro-mechanical coupled behavior. The simulated results were, however, partially matching with the field measurement. The simulated pressure build-up at the monitoring location showed linear and progressive increase, whereas the field measurement showed an abrupt increase associated with the fault slip We conclude that such difference between the modelling and the field test is due to the structure of the fault in the model which was represented as a combination of damage zone and core fractures. The modelled fault is likely larger in size than the real fault in Mont Terri site. Therefore, the modelled fault allows several path ways of fluid flow from the injection location to the pressure monitoring location, leading to smooth pressure build-up at the monitoring location while the injection pressure increases, and an early start of pressure decay even before the injection pressure reaches the maximum. We also conclude that the clay filling in the real fault could have acted as a fluid barrier which may have resulted in formation of fluid over-pressurization locally in the fault. Unlike the pressure result, the simulated fault deformations were matching with the field measurements. A better way of modelling a heterogeneous clay-filled fault structure with a narrow zone should be studied further to improve the applicability of the modelling method to fluid injection induced fault activation.

Lessons from Cross-Scale Studies of Water and Carbon Cycles in the Gwangneung Forest Catchment in a Complex Landscape of Monsoon Korea (몬순기후와 복잡지형의 특성을 갖는 광릉 산림유역의 물과 탄소순환에 대한 교차규모 연구로부터의 교훈)

  • Lee, Dong-Ho;Kim, Joon;Kim, Su-Jin;Moon, Sang-Ki;Lee, Jae-Seok;Lim, Jong-Hwan;Son, Yow-Han;Kang, Sin-Kyu;Kim, Sang-Hyun;Kim, Kyong-Ha;Woo, Nam-Chil;Lee, Bu-Yong;Kim, Sung
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.2
    • /
    • pp.149-160
    • /
    • 2007
  • KoFlux Gwangneung Supersite comprises complex topography and diverse vegetation types (and structures), which necessitate complementary multi-disciplinary measurements to understand energy and matter exchange. Here, we report the results of this ongoing research with special focuses on carbon/water budgets in Gwangneung forest, implications of inter-dependency between water and carbon cycles, and the importance of hydrology in carbon cycling under monsoon climate. Comprehensive biometric and chamber measurements indicated the mean annual net ecosystem productivity (NEP) of this forest to be ${\sim}2.6\;t\;C\;ha^{-1}y^{-1}$. In conjunction with the tower flux measurement, the preliminary carbon budget suggests the Gwangneung forest to be an important sink for atmospheric $CO_2$. The catchment scale water budget indicated that $30\sim40%$ of annual precipitation was apportioned to evapotranspiration (ET). The growing season average of the water use efficiency (WUE), determined from leaf carbon isotope ratios of representative tree species, was about $12{\mu}mol\;CO_2/mmol\;H_2O$ with noticeable seasonal variations. Such information on ET and WUE can be used to constrain the catchment scale carbon uptake. Inter-annual variations in tree ring growth and soil respiration rates correlated with the magnitude and the pattern of precipitation during the growing season, which requires further investigation of the effect of a monsoon climate on the catchment carbon cycle. Additionally, we examine whether structural and functional units exist in this catchment by characterizing the spatial heterogeneity of the study site, which will provide the linkage between different spatial and temporal scale measurements.

Mechanism of steel pipe reinforcement grouting based on tunnel field measurement results (터널 현장 계측결과를 통한 강관보강 그라우팅의 거동 메커니즘)

  • Shin, Hyunkang;Jung, Hyuksang;Lee, Yong-joo;Kim, Nag-young;Ko, Sungil
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.3
    • /
    • pp.133-149
    • /
    • 2021
  • This study aims to report the behavioral mechanism of steel pipe reinforcement grouting, which is being actively used to ensure the stability of the excavation surface during tunnel excavation, based on measurements taken at the actual site. After using a 12 m steel pipe attached with a shape displacement meter and a strain gauge to reinforce the actual tunnel surface, behavioral characteristics were identified by analyzing the measured deformation and stress of the steel pipe. Taking into account that the steel pipes were overlapped every 6 m, the measured data up to 7 m of excavation were used. In addition, the behavioral characteristics of the steel pipe reinforcement according to the difference in strength were also examined by applying steel pipes with different allowable stresses (SGT275 and SGT550). As a result of analyzing the behavior of steel pipes for 7 hours after the first excavation for 1 m and before proceeding with the next excavation, the stress redistribution due to the arching effect caused by the excavation relaxation load was observed. As excavation proceeded by 1 m, the excavated section exhibited the greatest deformation during excavation of 4 to 6 m due to the stress distribution of the three-dimensional relaxation load, and deformation and stress were generated in the steel pipe installed in the ground ahead of the tunnel face. As a result of comparing the behavior of SGT275 steel pipe (yield strength 275 MPa) and SGT550 steel pipe (yield strength 550 MPa), the difference in the amount of deformation was up to 18 times and the stress was up to 12 times; the stronger the steel pipe, the better it was at responding to the relaxation load. In this study, the behavior mechanism of steel pipe reinforcement grouting in response to the arching effect due to the relaxation load was identified based on the measured data during the actual tunnel excavation, and the results were reported.

The Selection of Proper Resource and Change of Salinity in Helianthus tuberosus L. Cultivated in Saemangeum Reclaimed Tidal Land (새만금간척지에서 뚱딴지(Helianthus tuberosus L.) 재배시 염류 특성 변화 및 적정 자원 선발)

  • Oh, Yang-Yeol;Lee, Jung-Tae;Hong, Ha-Cheol;Kim, Jae-Hyun;Seo, Woo-Duck;Kim, Sun;Ryu, Jin-Hee;Lee, Su-Hwan;Kim, Young-Joo
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.2
    • /
    • pp.73-78
    • /
    • 2018
  • BACKGROUND: Soil salinity of reclaimed tidal land in Korea is highly important factor. High salinity is harmful to crop productivity. Jerusalem artichoke (Helianthus tuberosus L.) is known to be salt-tolerant and has high adaptability to diverse pedo-climatic conditions. The objective of this study was to assess the changes of soil properties and crop productivity according to salt concentration in the reclaimed tidal lands. METHODS AND RESULTS: Experimental sites were selected at Saemangeum ($35^{\circ}46^{\prime}N$, $126^{\circ}37^{\prime}E$) reclaimed tidal land, and their dominant soil series were Munpo (coarse loamy, mixed, non-acid, mesic, typic Fluvaquents). H. tuberosus L were collected from 12 locations across Korea. Tubers were planted at $75{\times}25cm$ with EC 2 to $7dS\;m^{-1}$. Soil samples were periodically collected from both 0~20 cm and 20~40 cm depths of each site. Soil salinity and soil moisture contents were varied depending on weather conditions. Soil electrical conductivity varied from 1.0 to $5.9dS\;m^{-1}$, and soil moisture contents varied from 9.2 to 28.7%. The white-colored tubers of H. tuberosus L. collected from 'Yeongwol-gun' exhibited the highest height (207 cm), followed by the white-colored tubers of H. tuberosus L. collected from 'Iksan-si'(202 cm). The white-colored tubers of H. tuberosus L. collected from 'GyeongJu-si' showed the highest yield (549 kg/10a). The purple-colored tubers of H. tuberosus L. collected from 'Yeongwol-gun' showed the highest yield (615 kg/10a). CONCLUSION: Our results indicate that the plant height and tuber yield did not appear to be correlated. Considering yield and inulin content, the GyeongJu-si seemed to be suitable as the white-colored tubers of H. tuberosus L. and the Yeongwol-gun seemed to be suitable as the purple-colored tubers of H. tuberosus L. in the reclaimed tidal lands. However, it is necessary to consider the relationship between the inulin content and the yield.