• 제목/요약/키워드: City mode

검색결과 265건 처리시간 0.032초

도로 하중조건을 고려한 상용차 판스프링의 피로강도 평가 II (Fatigue Strength Evaluation of LCV Leaf spring Considering Road Load Response II)

  • 손일선;배동호;정원석;정원욱;박순철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1127-1132
    • /
    • 2003
  • Suspension system of vehicle have enough endurance during its life time to protect passenger. Spring is one of major part of vehicle. Thus, a fatigue strength evaluation for leaf spring based on road load response was carried out. At first, strain of leaf spring is measured on the city condition and proving ground condition. And next, the damage analysis of road load response data was carried out. And fatigue test of leaf spring were also carried out. Based on -N life relation, fatigue life of leaf spring was evaluated at belgian mode, city mode and drawing test specification. After that, it is compared the design life of leaf spring and evaluated fatigue life by belgian mode, city mode and drawing test specification. From the above, the maximum load-fatigue life relation of leaf spring was defined by test. and new test target of belgian mode and city mode was proposed to accept design specification of leaf spring. It is expect that proposed test target can verify leaf spring fatigue endurance at specific road condition.

  • PDF

서울시 도시형 버스의 추행패턴에 관한 연구 (A Study of Driving Pattern of City-bus in the City of Seoul)

  • 정남훈;이우택;선우명호;이영재;엄명도
    • 한국자동차공학회논문집
    • /
    • 제10권2호
    • /
    • pp.55-65
    • /
    • 2002
  • Emission from road traffic is one of the major sources of air pollution, and provides some undesirable effects on the atmspheric environment and human health. In the city of Seoul, the higher portion of diesel vehicles runs compared with that of other countries. Emission from the diesel vehicles is much higher than that of other vehicles. In this study, the driving pattern of city-bus in Seoul is investigated through on-road vehicle test and compared with the test modes of other countries in order to examine appropriateness of the present test mode that is taken in our country.

Environmental impact assessment for city logistics distribution systems

  • Guo, Jidong;Ma, Shugang
    • Environmental Engineering Research
    • /
    • 제22권4호
    • /
    • pp.363-368
    • /
    • 2017
  • The external diseconomy is hampering sustainable development of the city logistics sector. Burdens on urban environment imposed by the city logistics industry have been put in the spotlight. Based on the principle of Life Cycle Analysis, the comprehensive environment impact for city logistics systems is measured. Firstly, with the city logistics service chain as a whole, its business processes and their interactions with environment are analyzed. In total four types of major environment impact categories are determined. Secondly, case study is made on three city logistics operators located in Jing-Jin-Ji region of China with different business modes, respectively self-operation mode, joint distribution mode and the $3^{rd}$ Party Logistics or 3PL mode. Through analysis of energy consumption and emissions for various business processes, their comprehensive environmental impact values are finally obtained. Thirdly, horizontally comparative analysis is carried out to these three modes of the urban logistics distribution systems. Results show the advantages of the 3PL and the joint distribution modes in developing greener urban logistics distribution. Future research avenues and policy suggestions are proposed finally.

Multi-Operand Radix-2 Signed-Digit Adder using Current Mode MOSEET Circuits

  • Sakamoto, Masahiro;Hamano, Daisuke;Higuchi, Yuuichi;Kiriya, Takechika;Morisue, Mititada
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -1
    • /
    • pp.167-170
    • /
    • 2000
  • This paper describes a novel multi-operand radix-2 signed-digit(SD) adder. The novel multi-operand addition algorithm can eliminate carry propagation chain by dividing the input operands into even place part and odd place part, and adding them each. The multi-operand adder with this algorithm can add six operands in parallel, and is faster than the ordinary method of SD adder binary tree. A hardware model for proposed adder is shown which is implemented by the current-mode MOSFET circuit technology. Simulations have been made by SPICE in order to verify the function of the proposed circuit.

  • PDF

매연저감을 위한 천연가스 Dual-Fuel 엔진의 시내버스 적용평가 (The Evaluation on Smoke Reduction by Natural Gas Dual Fuel Engine for City Bus)

  • 엄명도;조강래;오용석;한영출
    • 한국대기환경학회지
    • /
    • 제13권3호
    • /
    • pp.215-220
    • /
    • 1997
  • CNG dual fuel engine for heavy duty diesel engine developed by AFS International in Canada has been equipped to a Korean city bus engine and tested to compare the engine performance and the emission characteristics with the existing diesel fueled engine. Also the dual-fuel engine was applied to the city bus for road test. The results are summarized as follows. Performance optimization has been carried out to have engine power equivalent to or better than the diesel fueled engine. Smoke is decreased by 85% by Korean smoke 3 mode test. By 13 mode test CO is increased by 453% and THC is increased by 2, 086%. NOx is decreased by 7% in laboratory. D-13 test mode was changed in 1996 Korean regulation. Even though THC is increased very much, it's not too serious problem since CO and HC emission of diesel engine is very little compared to gasoline engine and more than 75% of THC is CH$_4$. But the reduction technologies of CO and HC has to be considered.

  • PDF

Traffic management for large-scale evacuation with public transportation and calculation of appropriate operating ratio

  • Ham, Seunghee;Lee, Jun;Lee, Sang Jo
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3347-3352
    • /
    • 2022
  • In 2013, the International Atomic Energy Agency (IAEA) changed the recommended maximum range of the Emergency Planning Zone (EPZ) to 30 km, and the Kori Nuclear Power Plant in Republic of Korea has also expanded the EPZ to 30 km, following the recommendation. As a result, metropolitan cities with a high population density are contained within the EPZ, and evacuating millions of people should be considered if the 30 km range of evacuation is to take place. This study proposes an evacuation plan using buses (public transportation) to transport people outside of the EPZ, quickly and efficiently. To verify the appropriate mode share ratio of buses that can guarantee the right of vulnerable road users and reduce traffic congestion, a model was built simulating the Kori Nuclear Power Plant in Ulsan Metropolitan City. The scenarios were established by changing the mode share ratio of buses and passenger cars by 10%. Considering a large-scale network analysis at the city level, a cell transmission model was applied to calculate the evacuation time in each scenario. The result shows that the optimal mode share ratio of buses is 40%, with a total evacuation time of 132 min, considering feasible bus fleets in Ulsan Metropolitan City.

SUV EREV의 주행평가를 통한 배터리 SOC 제어 특성에 관한 연구 (A Study on the Characteristics of Battery SOC Management for SUV Extended Range EV)

  • 정태철;김재환;김선경;선진;김석명;강동우;노윤주
    • 한국자동차공학회논문집
    • /
    • 제22권2호
    • /
    • pp.44-51
    • /
    • 2014
  • This paper describes system definition of the extended range EV and presents cruising strategy of EV mode and ER mode. Also high voltage battery strategic SOC could be indicated and compared depends on various generator working cycles. A C-segment SUV has been produced and carried out cruising test in order to validate on highway, city and hill climbing road. This paper shows advantages and disadvantages of SOC variation on each road environments and presents the strategies as the cruising test results. On the basis of the test result, this paper suggests future works and research directions for strategy of battery management to extended range EV.

Pulse-Width Modulation Strategy for Common Mode Voltage Elimination with Reduced Common Mode Voltage Spikes in Multilevel Inverters with Extension to Over-Modulation Mode

  • Pham, Khoa-Dang;Nguyen, Nho-Van
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.727-743
    • /
    • 2019
  • This paper presents a pulse-width modulation strategy to eliminate the common mode voltage (CMV) with reduced CMV spikes in multilevel inverters since a high CMV magnitude and its fast variations dv/dt result in bearing failure of motors, overvoltage at motor terminals, and electromagnetic interference (EMI). The proposed method only utilizes the zero CMV states in a space vector diagram and it is implemented by a carrier-based pulse-width modulation (CBPWM) method. This method is generalized for odd number levels of inverters including neutral-point-clamped (NPC) and cascaded H-bridge inverters. Then it is extended to the over-modulation mode. The over-modulation mode is implemented by using the two-limit trajectory principle to maintain linear control and to avoid look-up tables. Even though the CMV is eliminated, CMV spikes that can cause EMI and bearing current problems still exist due to the deadtime effect. As a result, the deadtime effect is analyzed. By taking the deadtime effect into consideration, the proposed method is capable of reducing CMV spikes. Simulation and experimental results verify the effectiveness of the proposed strategy.

Novel Single-State PWM Technique for Common-Mode Voltage Elimination in Multilevel Inverters

  • Nguyen, Nho-Van;Quach, Hai-Thanh;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.548-558
    • /
    • 2012
  • In this paper, a novel offset-based single-state pulse width modulation (PWM) method for achieving zero common-mode voltage (CMV) and reducing switching losses in multilevel inverters is presented. The specific active switching state of the zero common-mode (ZCM) voltage that approximates the reference voltage can be deduced from the switching state sequence of the reduced CMV phase disposition PWM (CMV PD PWM) method. From the reference leg voltages for the zero common-mode voltage, an N-to-2-level transformation defines a virtual two-level inverter and the corresponding nominal leg voltage references. The commutation process of the reduced CMV PD PWM method in a multilevel inverter and its outputs can be simply followed in a nominal switching time diagram for the virtual inverter. The characteristics of the reduced CMV PD PWM and the single-state PWM for zero common-mode voltage are analyzed in detail in this paper. The theoretical analysis of the proposed PWM method is verified by experimental results.