• Title/Summary/Keyword: Circulation control

Search Result 624, Processing Time 0.029 seconds

Effect of Circuit Training on Estrogen Hormone, Serum Lipids in Obese Middle-aged Women (Circuit Training이 비만중년여성의 여성호르몬, 혈중지질에 미치는 영향)

  • Shin, Koun-Soo;Kim, Young-Jae;Kim, Min-Sub;Seo, Dae-Kyung;Oh, Sean-Ok;Kim, Ja-Bong
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.6
    • /
    • pp.1417-1424
    • /
    • 2014
  • This study is supposed to offer data related to whether circulation training(aerobic and anaerobic exercise) focused on overweight women has positive effects on reducing fat and increasing muscles for middle-aged women. This study aims to investigate how the circulation training effect overweight middle-aged women's female hormone, blood lipid, which offers basic data of exercise program to keep the overweight middle-aged women healthy. Participants for the study are 30 to 45-year-women who were willing to take part in a M Sports Diet Program in G gu, B metropolitan city, did not have any disease. They were 29 overweight women and showed more than 30% of body fat percentage. Female hormone, blood lipid were measured twice before and in 12 weeks after exercise. The results obtained from this study are given as in the following. Although estrogen has significantly increased after the circulation training, there was no meaningful difference from the control group. After 12-weeks-circulation training, even though there were no meaningful differences. before the training, the circulation training group was significantly higher than the control group. Although TC has significantly decreased after the circulation training, there was no meaningful difference from the control group. the circulation training group was significantly lower than the control group. Even though TG was no significantly decreased after the circulation training, there was no significantly difference from the control group. the circulation training group was significantly lower than the control group. Even though HDL-C has significantly increased after the circulation training, there was no meaningful difference from the control group. the circulation training group was significantly higher than the control group. Even though LDL-C has significantly decreased after the circulation training, there was no significantly difference from the control group. the circulation training group was significantly lower than the control group.

Systemic Simulation Models for the Theoretical Analysis of Human Cardiovascular System (인체 심혈관계의 이론적 분석을 위한 시스템 시뮬레이션모델에 관한 연구)

  • Ko Hyung Jong;Youn Chan Hyun;Shim Eun Bo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.12
    • /
    • pp.1181-1188
    • /
    • 2004
  • This paper reviews the main aspects of cardiovascular system dynamics with emphasis on modeling hemodynamic characteristics using a lumped parameter approach. Methodological and physiological aspects of the circulation dynamics are summarized with the help of existing mathematical models: The main characteristics of the hemodynamic elements, such as the heart and arterial and venous systems, are first described. Lumped models of micro-circulation and pulmonary circulation are introduced. We also discuss the feedback control of cardiovascular system. The control pathways that participate in feedback mechanisms (baroreceptors and cardiopulmonary receptors) are described to explain the interaction between hemodynamics and autonomic nerve control in the circulation. Based on a set-point model, the computational aspects of reflex control are explained. In final chapter we present the present research trend in this field and discuss the future studies of cardiovascular system modeling.

A Study on the Guideline of Spatial Composition and Circulation in Triages and Entrances Area in Emergency Departments for Efficient Infection Control (응급부 진입구역과 환자분류구역의 감염관리를 위한 환자동선과 공간구성 계획에 대한 연구)

  • Kang, Jeeeun;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.1
    • /
    • pp.41-49
    • /
    • 2019
  • Purpose: After Mers breakout in 2015, major hospital in Korea have been renovated the emergency department to make a separate infection control zone for high-risk patient with potential infection and to improve a triage area and an entrance area for efficient patient evaluation. However, there are no specific design standards to reinforce infection control for patients and staffs safety. Therefore, it is important to establish of initial design factors in the triage and entrance area as a guideline. Methods: 5 cases which had been recently renovated are selected to analyze patient circulation and spatial composition in a triage area and an entrance area. The partial floor plans of each case are represented as bubble diagrams to help understanding of different patient circulation flows. Based on this analysis, significant design factors which should be considered in planning stage for infection control have been extracted. Results: 13 design factors are established. Using these design factors, patient circulation diagram is generated to provide an optimized suggestion for efficient infection control. Implications: This suggestion provides basic databases to start to establish design guideline in the triage area and the entrance area to minimize infection spreading in the emergency department.

Three-dimensional Numerical Modelling of Seawater Circulation of Semi-enclosed Bay with the Flow-control Structures

  • JONG-KYU KIM;TAE-SOON KANG;HEON-TAE KIM
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.3
    • /
    • pp.35-42
    • /
    • 2001
  • The characteristics of tidal circulation with the flow-control structures using the three-dimensional numerical model (POM, Princeton Ocean Model) of Chinhae Bay, Korea were investigated. To confirm th efficiencies of flow-control structures, the training wall and submerged training wall were constructed at the mouth and narrow channel in Chinhae Bay. On the basis of the present investigation, the tidal circulation induced by the construction of flow-control structures could enhance the water exchange improvement appropriately. And, th training wall at the central is more dominated than the other structures for the efficient of water exchange. The sites and types of structure and flow patterns seem to be very sensitive in tidal simulation and changes in flow fields.

  • PDF

An Experimental Study on Variable-Speed Control of an Ground-Water Circulation Pump for a Ground Source Multi-Heat Pump System (주거용 건물 지열원 멀티 히트펌프시스템의 지열순환펌프 가변유량제어에 관한 실증연구)

  • Song, Suwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.443-449
    • /
    • 2013
  • The purpose of this study is to propose an enhanced variable-speed control method of ground-water circulation pumps using inlet and outlet ground-water temperature difference and analyze its effect for the ground source multi-heat pump system installed in a single-family house. As a result, it has shown to significantly reduce the electricity use of ground-water circulation pump and improve overall system Coefficient of Performance (COP) due to the proposed variable-speed control under partial load conditions after oversized and inefficient single-speed pump retrofit.

The Study of the Circulation Current Control Scheme on Single Phase Inverter System (단상 인버터 시스템에서 순환 전류 제어 기법에 관한 연구)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.60-69
    • /
    • 2014
  • This paper proposed the circulation current control scheme in the single phase inverter system. The load experiment of the power conversion system including the UPS usually uses the passive components such as resistors and inductors. Therefore, the energy consumption is serious problem. In addition, the system is out of order when it is installed in the local area, and the load experiment can not perform adequately after troubleshooting, because there is no the load equipment, and the power capacity is not enough in the local area. The paper does the research on the circulation current control scheme, it does not need the load equipment, and the load current can reuse as the input current of the equipment. Instead of the conventional method the voltage-voltage and voltage-current control scheme introduced the parallel converter concept is newly proposed, and the validity of the proposed control scheme is investigated by both simulation and experimental results.

Effects of Self-Foot Reflexology on Stress, Fatigue and Blood Circulation in Premenopausal Middle-Aged Women (자가 발반사요법이 폐경 전 중년여성의 스트레스와 피로 및 혈액순환에 미치는 효과)

  • Jang, Soo-Hyun;Kim, Kye-Ha
    • Journal of Korean Academy of Nursing
    • /
    • v.39 no.5
    • /
    • pp.662-672
    • /
    • 2009
  • Purpose: This study was to examine the effects of self-foot reflexology on stress, fatigue and blood circulation in premenopausal middle-aged women. Methods: A quasi-experimental nonequivalent control group, pretest-posttest design was used. Participants were 59 premenopausal, middle-aged women in their 40s and 60s living in G city: 30 in the experiment group and 29 in the control group. Data were collected from May to August 2008. Self-foot reflexology was performed three times a week for 6 weeks for 40 min at each session. Results: The results showed that self-foot reflexology was effective in reducing perceived stress and fatigue and helped blood circulation in premenopausal middle-aged women. Conclusion: Self-foot reflexology may be an effective nursing intervention in reducing perceived stress and fatigue and in improving blood circulation.

An Architectural Study on the Efficient Evacuation Plan for the Change of Circulation System (동선체계 변경 시 유효한 피난계획에 대한 건축계획적 연구)

  • Kim, Hee-Kyo
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.1
    • /
    • pp.261-268
    • /
    • 2022
  • It is a common situation to limit entrance to the multi-use buildings for efficient control and prevention of the spread of COVID-19. This study chiefly aims to find out efficient methods to establish evacuation plans when temporary changes of the building circulation system occurs. If architectural design were done with the pre-consideration for the changes of building circulation systems, through the analysis of multi-use buildings, it is expected to we can prevent the spread of disasters when they happen. This study is geared to establish efficient evacuation plan for the temporary circulation plan when disaster happen, through the analysis of multi-use buildings for architectural planning as well as the human behavioral patterns.

An Experimental Study of Coanda Effect on the Flapped Control Surfaces (콴다효과를 응용한 플랩이 달린 고양력 날개장치에 대한 실험적 연구)

  • 안해성;김효철
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.5
    • /
    • pp.10-16
    • /
    • 2003
  • To investigate the jet effect on circulation control, a segment of model was prepared and inserted horizontally across the test section of the cavitation tunnel. The hydrodynamic forces acting on the model were measured under the 2 dimensional flow behavior. Circulation flow control requires higher flow rate of water jet than boundary layer control does. Jet injection is effective in increasing lift coefficient and the increments reach to 160% in a certain combination of parameters such as an angle of attack, jet flow rate and flap angle. The blown water jet not only reduces form drag but also thrust effect, which is sometimes greater than the form drag in specific conditions.

Hydraulic and Numerical Modeling of Seawater Circulation of Semi-enclosed Bay with the Flow-control Structures (유동제어구조물에 의한 내만의 해수순환 모델링)

  • 김종규;강태순;김헌태
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.3
    • /
    • pp.20-28
    • /
    • 2000
  • Using the hydraulic and numerical model of semi-enclosed bay (Chinhae Bay), the efficiencies of flow-control structures on the seawater-circulation in the inner bay were investigated. Expecially, this study was confirmed the effectiveness of the flow-control structures at the mouth and narrow channel of Chinhae Bay through the experiments. The system of flow-control structures could enhance the water exchange improvement appropriately. The results of this study can be used as the long-term and integrated environmental impact assessment model in the inner bay.

  • PDF