• Title/Summary/Keyword: Circulation Rate

Search Result 748, Processing Time 0.028 seconds

An Experimental Study on Correlation between Oil Discharge and Various Operating Conditions of a CO2 Compressor (CO2 압축기의 운전조건과 오일토출의 상관분석에 관한 실험적 연구)

  • Lee, Ik-Soo;Kang, Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.73-79
    • /
    • 2011
  • A portion of oil for lubrication of compressor flows together with refrigerant in the refrigeration system. If the oil discharge from a compressor is increased in the refrigeration system, not only pressure drop is increased in other components, such as evaporator and gas cooler, but also heat transfer coefficient in the heat exchangers is decreased. Oil discharge rate from a compressor may strongly depend on operating conditions of a compressor. In this study, one stage single rotary compressor is employed for measuring oil circulation ratio(OCR). Carbon dioxide and PAG oil are used as refrigerant and lubricant. Using a U-tube densimeter, mixture density is measured. Oil circulation ratio(OCR) can be estimated by measured mixture density. The results obtained indicate that the oil circulation ratio(OCR) is increased as the suction temperature or compressor operating frequency is increased. Oil circulation ratio(OCR) correlation of the compressor is also suggested.

1-D Two-phase Flow Investigation for External Reactor Vessel Cooling (원자로 용기 외벽냉각을 위한 1차원 이상유동 실험 및 해석)

  • Kim, Jae-Cheol;Park, Rae-Joon;Cho, Young-Rho;Kim, Sang-Baik;Kim, Sin;Ha, Kwang-Soon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.5
    • /
    • pp.482-490
    • /
    • 2007
  • When a molten corium is relocated in a lower head of a reactor vessel, the ERVC (External Reactor Vessel Cooling) system is actuated as coolant is supplied into a reactor cavity to remove a decay heat from the molten corium during a severe accident. To achieve this severe accident mitigation strategy, the two-phase natural circulation flow in the annular gap between the external reactor vessel and the insulation should be formed sufficiently by designing the coolant inlet/outlet area and gap size adequately on the insulation device. For this reason, one-dimensional natural circulation flow tests and the simple analysis were conducted to estimate the natural circulation flow under the ERVC condition of APR1400. The experimental facility is one-dimensional and scaled down as the half height and 1/238 channel area of the APR1400 reactor vessel. The calculated circulation flow rate was similar to experimental ones within about ${\pm}$15% error bounds and depended on the form loss due to the inlet/outlet area.

Optimization of an extra vessel electromagnetic pump for Lead-Bismuth eutectic coolant circulation in a non-refueling full-life small reactor

  • Kang, Tae Uk;Kwak, Jae Sik;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3919-3927
    • /
    • 2022
  • This study presents an optimal design of the coolant system of a non-refueling full-life small reactor by analyzing the space-integrated geometrical and electromagnetic variables of an extra vessel electromagnetic pump (EVEMP) for the circulation of a lead-bismuth eutectic (LBE) coolant. The EVEMP is an ideal alternative to the thermal-hydraulic system of non-refueling full-life micro reactors as it possesses no internal structures, such as impellors or sealing structures, for the transportation of LBE. Typically, the LBE passes through the annular flow channel of a reactor, is cooled by the heat exchanger, and then circulates back to the EVEMP flow channel. This thermal-hydraulic flow method is similar to natural circulation, which enhances thermal efficiency, while providing a golden time for cooling cores in the event of an emergency. When the forced circulation technology of the EVEMP was applied, the non-refueling full-life micro reactor achieve an output power of 60 MWt, which is higher than that achievable via the natural circulation method (30 MWt). Accordingly, an optimized EVEMP for Micro URANUS with a flow rate of 4196 kg/s and developed pressure of 73 kPa under a working temperature of 250 ℃ was designed.

Variables Affecting Circulation of Library Collections: Using Latent Growth Model (도서관 대출권수에 영향을 미치는 변수에 관한 연구 - 잠재성장모형을 이용하여 -)

  • Sungjae, Park
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.56 no.4
    • /
    • pp.455-472
    • /
    • 2022
  • The purpose of this study is to analyze variables affecting the number of circulated books which is one of the indicators representing the library use behavior. For the analysis, 2015-2019 data for public libraries was acquired from the National Library Statistics System. The Latent Growth Model estimating a latent intercept and a latent slop based on the individual library trajectories was applied. The results are as followed; first, the circulation rate tends to be decreased. Second, the most affecting factor on the library circulation decrease was the collection budget. This study suggests increasing a collection budget in order to prevent the library circulation decrease while the library is operating in a daily routine.

Experimental study on vibration projection of seawater circulation pumps in nuclear power plant

  • Lin Bin;Huang Qian;Zhang Rongyong;Zhu Rongsheng;Fu Qiang;Wang Xiuli
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2576-2583
    • /
    • 2024
  • In this paper, the similarity criterion and dimensionless conversion method combined with the elasticity condition and Hooke's law are used to derive the functional relationship of the maximum effective value of the vibration velocity between the prototype pump and the model pump. The seawater circulation pump of a nuclear power plant is used as the prototype pump, and the model pump is obtained by performance conversion and choosing the appropriate scale, and the vibration state of the model pump under different flow rates is measured and analyzed. The vibration data of the model pump through the function relationship to find out the vibration parameters of the prototype model pump, and compare with the vibration data of the seawater circulation pump in reality. It can be seen that with the increase of flow rate, the maximum effective value of the vibration velocity of both model and prototype decreases and then increases, and the relative error is small, the maximum value is 7.7757%. Therefore, it can be considered that the functional relationship of model pump converted to prototype pump derived in this paper can be used to analyze the vibration of the actual seawater circulation pump of coastal nuclear power plant.

Effect of changing position from supine to standing up-right on the circulation in young men and women (앙와위에서 직립자세로의 체위변화가 정상인의 순환에 미치는 영향)

  • 최명애;김종임;김현리
    • Journal of Korean Academy of Nursing
    • /
    • v.19 no.3
    • /
    • pp.285-298
    • /
    • 1989
  • This study investigated the effect of changing position from supine to standing upright on the circulation of young men and women. Healthy men and women ranging from age of 18 to 24 were examined. Two minutes before standing, the baseline heart rate and blood pressure were measured. Heart rate and blood pressure were recorded immediately and at every minute for 10 minutes after standing upright. Differences in heart rate and blood pressure between supine and standing upright position were evaluated. The results were summarized as follows : 1. Heart rate increased significantly immediately and at every minute for 10 minutes after standing upright. 2. Systolic blood pressure increased significantly immediately and at every minute for 4 minutes after standing upright. 3. Diastolic and mean blood pressure increased significantly immediately and at every minute for 10 minutes after standing upright. 4. Pulse pressure immediately and at every minute for 10 minutes after standing upright was significantly narrower than that of supine position. 5. There was no significant difference of heart rate between men and women after standing upright. 6. Systolic and diastolic blood pressure of men after standing upright was significantly greater than those of women. From these results, it may be concluded that heart rate, systolic, diastolic and mean blood pressure and pulse pressure increase after standing upright, and systolic and diastolic blood pressure in men is greater than those of women after standing upright.

  • PDF

The Activation Plan of Resource Circulation of Copper through Analysis of Waste Resources Circulation Flow (동의 폐자원흐름분석을 통한 자원순환 활성화 방안)

  • Lee, Hi Sun;Woo, Jeong-Hun;Lee, Jae-Chun
    • Resources Recycling
    • /
    • v.23 no.2
    • /
    • pp.26-36
    • /
    • 2014
  • The materials flow of copper can be analyzed into up-stream and down-stream stages based on the literature survey. Discharge and recycling stages in the down-stream have been particularly analyzed through the field survey. The waste nickel resources circulation flow may conveniently be grouped into 4 stages discharge import, collection disuse, resource recovery and product production export, the resources mainly consist of copper scrap and stainless steel scrap in 2010. The resource circulation rate of 36.83% is obtained from the above flow. Various plans are therefore, suggested in each stage to increase resource circulation rate. At discharge import stage, it is suggested to consider this kind of waste as an important resources if it is appropriately classified in detail, basides applying quota tariff to this kind of waste. At collection disuse stage, the plan of stabilizing supply and demand is suggested through the improvement of bidding system. Resources professional cycling stage crushing and grinding companies foster coexistence between large and small plans and strategies were suggested. At product production export stage, the integrated approval is suggested approval for licensing to register units as waste-treating facilities instead of exempting registration under the present condition to activate recycling industries.

The Effect of Operating Conditions on Cross-Flow Ultrafiltration with using Polyethylene Glycol (Polyethylene Glycol을 이용한 Cross-Flow Ultrafiltration에 있어서 운전조건의 영향)

  • Yoo, Kun-Woo;Seo, Hyung-Joon
    • Applied Chemistry for Engineering
    • /
    • v.9 no.7
    • /
    • pp.950-955
    • /
    • 1998
  • The objective of this study was to investigate the effect of running time, operating pressure, feed concentration and circulation rate on the permeation flux and the rejection rate in cross-flow ultrafiltration of polyethylene glycol(PEG) solution of molecular weight($M_w$) 8000 and 20000. The membranes used for this study were MWCO(Molecular Weight Cut-off) of 6 K and 20 K. The experiments were performed at the operating pressures of 7, 14 and 28 psi, the circulation rates of 1000 mL/min and 2000 mL/min, and the feed concentration of 100 mg/L and 1000 mg/L. At a constant pressure, the permeation flux and the observed rejection($R_o$) appeared to be approximately constant within the range of running time, 0~480 min. The permeation flux increased with increasing the operating pressure, and it increased with decreasing the feed concentration and decreasing Mw of PEG at a given pressure. On the other hand, $R_o$ decreased slightly with increasing the operating pressure. However, $R_o$ increased with increasing the feed concentration and increasing of $M_w$ of PEG at a given pressure. The variation in circulation rates did not cause any significant influence on the permeation flux. Increasing of circulation rate caused the increase of $R_o$, and $\alpha$ was increased substantially with the decrease of $M_w$ of PEG. The dimensionless parameter. permeability ratio($\alpha$), which was used to investigate flux-pressure behavior, was increased with the increase in circulation rate and operating presure. The value of $\alpha$ was less than 1 in all cases. The estimated intrinsic rejection(R). which was obtained from mass transfer coefficient, was decreased with the increase of operating pressure. However R increased with the increase of linear velocity of feed and $M_w$ of PEG.

  • PDF

Characteristics of Solar Desalination System Using Refrigerant-123 As a Heating Source (R123 열원 적용 증발식 담수 시스템 특성 연구)

  • Yun, Sang-Kook;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.33-38
    • /
    • 2010
  • The evaporative desalination system using solar thermal energy would be the efficient and attractive method to get fresh water from brine due to low carbon dioxide generation. In this research the solar desalination system as a heating source of refrigerant R123 in the evaporator was considered. The circulation of refrigerant in the evaporator can reduce the energy consumption of the system, because of using the latent heat of the refrigerant 123 instead of the sensible heat of present hot water. The system was comprised of the single-stage fresh water production unit on the capacity of 1ton/day with shell and tube type evaporator, heaters instead of solar collector to supply the proper heat to refrigerant, and refrigerant and brine circulation systems. Various operating flowrate and temperature ranges were varied in the experiments to get the optimum design data. The results showed that the optimum flow rate of brine feed rate to evaporator was 1.2Liter/min, and the yield of fresh water was increased as higher temperature of feed brine. It was confirmed that the circulation flowrate of heating source of refrigerant was decrease of one fifth of the present warm water system, and very efficient system for solar desalination.

Research on heat transfer coefficient of supercritical water based on factorial and correspondence analysis

  • Xiang, Feng;Tao, Zhou;Jialei, Zhang;Boya, Zhang;Dongliang, Ma
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1409-1416
    • /
    • 2020
  • The study of heat transfer coefficient of supercritical water plays an important role in improving the heat transfer efficiency of the reactor. Taking the supercritical natural circulation experimental bench as the research object, the effects of power, flow, pipe diameter and mainstream temperature on the heat transfer coefficient of supercritical water were studied. At the same time, the experimental data of Chen Yuzhou's supercritical water heat transfer coefficient was collected. Through the factorial design method, the influence of different factors and their interactions on the heat transfer coefficient of supercritical water is analyzed. Through the corresponding analysis method, the influencing factors of different levels of heat transfer coefficient are analyzed. It can be found: Except for the effects of flow rate, power, power-temperature and temperature, the influence of other factors on the natural circulation heat transfer coefficient of supercritical water is negligible. When the heat transfer coefficient is low, it is mainly affected by the pipe diameter. As the heat transfer coefficient is further increased, it is mainly affected by temperature and power. When the heat transfer coefficient is at a large level, the influence of the flow rate is the largest at this time.