• Title/Summary/Keyword: Circulation Area

Search Result 746, Processing Time 0.029 seconds

One-Dimensional Analysis of Air-Water Two Phase Natural Circulation Flow (공기와 물의 이상 자연순환 유동의 1 차원 해석)

  • Park, Rae-Joon;Ha, Kwang-Soon;Kim, Jae-Cheol;Hong, Seong-Wan;Kim, Sang-Baik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2626-2631
    • /
    • 2007
  • Air-water two phase natural circulation flow in the T-HERMES (Thermo-Hydraulic Evaluation of Reactor cooling Mechanism by External Self-induced flow)-1D experiment has been evaluated to verify and evaluate the experimental results by using the RELAP5/MOD3 computer code. The RELAP5 results have shown that an increase in the coolant inlet area leads to an increase in the water circulation mass flow rate. However, the water outlet area does not effective on the water circulation mass flow rate. As the coolant outlet moves to a lower position, the water circulation mass flow rate decreases. The water level is not effective on the water circulation mass flow rate. As the height increases in the air injection part, the void fraction increases. However, the void fraction in the upper part of the air injector maintains a constant value. An increase in the air injection mass flow rate leads to an increase in the local void fraction, but it is not effective on the local pressure.

  • PDF

Preliminary Experimental Study on the Two-phase Flow Characteristics in a Natural Circulation Loop (자연순환 루프에서 이상유동 특성에 관한 예비실험 연구)

  • Kim, Jae-Cheol;Ha, Kwang-Soon;Park, Rae-Joon;Hong, Seong-Wan;Kim, Sang-Baik
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.308-311
    • /
    • 2008
  • As a severe accident mitigation strategy in a nuclear power plant, ERVC(External Reactor Vessel Cooling) has been proposed. Under ERVC conditions, where a molten corium is relocated in a reactor vessel lower head, a natural circulation two-phase flow is driven in the annular gap between the reactor vessel wall and its insulation. This flow should be sufficient to remove the decay heat of the molten corium and maintain the integrity of the reactor vessel. Preliminary experimental study was performed to estimate the natural circulation two-phase flow. The experimental facility which is one dimensional, the half height, and the 1/238 channel area of APR1400, was prepared and the experiments were carried out to estimate the natural circulation two-phase flow with varying the parameters of the coolant inlet area, the heat rate, and the coolant inlet subcooling. In results, the periodic circulation flow was observed and the characteristics were varied from the experimental parameters. The frequency of the natural circulation flow rate increased as the wall heat flux increased.

  • PDF

Analysis of Two Phase Natural Circulation Flow in the Reactor Cavity under External Vessel Cooling (원자로용기 외벽냉각시 원자로공동에서 이상유동 자연순환 해석)

  • Park, Rae-Joon;Ha, Kwang-Soon;Kim, Sang-Baik;Kim, Hee-Dong
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2141-2145
    • /
    • 2004
  • As part of study on thermal hydraulic behavior in the reactor cavity under external vessel cooling in the APR (Advanced Power Reactor) 1400, one dimensional two phase flow of steady state in the reactor cavity have been analyzed to investigate a coolant circulation mass flow rate in the annulus region between the reactor vessel and the insulation material using the RELAP5/MOD3 computer code. The RELAP5/MOD3 results have shown that a two phase natural circulation flow of 300 - 600 kg/s is generated in the annulus region between the reactor vessel and the insulation material when the external vessel cooling has been applied in the APR 1400. An increase in the heat flux of the inner vessel leads to an increase of the coolant mass flow rate. An increase in the coolant outlet area leads to an increase in the coolant circulation mass flow rate, but the coolant inlet area does not effective on the coolant circulation mass flow rate. The change of the lower coolant outlet to a lower position affects the coolant circulation mass flow rate, but the variation trend is not consistent.

  • PDF

1-D Two-phase Flow Investigation for External Reactor Vessel Cooling (원자로 용기 외벽냉각을 위한 1차원 이상유동 실험 및 해석)

  • Kim, Jae-Cheol;Park, Rae-Joon;Cho, Young-Rho;Kim, Sang-Baik;Kim, Sin;Ha, Kwang-Soon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.5
    • /
    • pp.482-490
    • /
    • 2007
  • When a molten corium is relocated in a lower head of a reactor vessel, the ERVC (External Reactor Vessel Cooling) system is actuated as coolant is supplied into a reactor cavity to remove a decay heat from the molten corium during a severe accident. To achieve this severe accident mitigation strategy, the two-phase natural circulation flow in the annular gap between the external reactor vessel and the insulation should be formed sufficiently by designing the coolant inlet/outlet area and gap size adequately on the insulation device. For this reason, one-dimensional natural circulation flow tests and the simple analysis were conducted to estimate the natural circulation flow under the ERVC condition of APR1400. The experimental facility is one-dimensional and scaled down as the half height and 1/238 channel area of the APR1400 reactor vessel. The calculated circulation flow rate was similar to experimental ones within about ${\pm}$15% error bounds and depended on the form loss due to the inlet/outlet area.

A Study on the Circulation System of Biosafety Level 4 Laboratory Facilities (생물안전 4등급(BL4) 실험시설의 동선계획에 관한 연구)

  • Kwon, Soonjung;Choi, Hongbin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.1
    • /
    • pp.23-32
    • /
    • 2011
  • Recently, with the advent of high risk infectious agent such as the Ebola virus, SARS, special research facilities dealing with such dangerous pathogenic are drawing attention gradually. Especially, this kind of facilities can be called BL4(Biosafety Level 4) facility. At the moment, Korean government is going to construct BL4 institute in order to handle efficiently such kind of pathogen. However, there are no proper design guidelines for BL4 facility. This paper proposes circulation system of BL4 facility on the basis of analysis of existing BL4 guidelines of Canada, and Korean BL3 facilities. The outcomes of this study are as follows. At first, functional areas of BL4 facilities have been divided into three categories according to the hazard level ; dangerous area, transitional area, and ordinary area. Secondly, circulation system of BL4 facility has been explored as a form of diagram according to the circulating subjects. These include human, laboratory animals, hazardous pathogen, equipments and cloth. This study has some limitations in that it lacks empirical evidences and concrete SOPs(Standard Operating Procedure). Despite of some weaknesses, it is expected to give some preliminary guidelines for the design of circulation system in BL4 facilities.

A Study on Hygienic Spatial Composition of Self-Service Restaurants by Applying HACCP (HACCP를 적용한 셀프서비스 식당의 위생적 공간구성에 관한 연구)

  • Lee, Jong-Ran
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.5
    • /
    • pp.178-187
    • /
    • 2011
  • This research suggested the hygienic spatial composition of sell-service restaurants applying HACCP(Hazard Analysis and Critical Control Point System). The circulation of the food, dishes, waste, workers and customers were each fractionated and arranged according to the hygienic sequence of cooking food in kitchen and process for eating food within the customer space. The spaces were separated by the degree of cleanness(clean area, semi-clean area, contaminated area). After that, hygiene facilities to remove contamination and pass facilities intended to control moving were added at the possible points of cross-contamination in oder to prevent the cross-contamination. For hygienic spatial composition of self-service restaurant, the following should be acknowledged: In the kitchen, spaces in which the food is handled after being heated should be located in the clean area. As of the customer space, spaces where dishes are prepared, food and water is received, and the table hall should be located in the clean area. Food circulation should flow from the contaminated area to the clean area. Food, dishes, waste should be moved through pass facilities so that workers do not have to come and go between other areas of cleanness. Also lockers for private clothes and lockers for uniforms should be separated. Hygiene facilities should be easily accessible so that workers can use them whenever they enter their working area. The contaminated area where dirty dishes are dealed with should be separated from the clean area. Waste should be thrown out without crossing cooking areas. As of customer circulation, the hygiene facility for hand washing should be located near the space where dishes for self-service are placed. The customer circulation should lead customers to leave restaurants after giving back the dirty dishes in the contaminated area.

An Analytical Study on the Circulation of the Small-scale Elderly Care Facilities in JeollaNamdo and Gwangju -Focusing on the Analysis on Spatial Depth and Visible Area- (전라남도.광주광역시 소규모요양시설의 동선분석연구 -공간깊이와 가시영역분석을 중심으로-)

  • Kim, Jeong-Mi;Cho, Ju-Young;Lee, Hyo-Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.15 no.1
    • /
    • pp.23-32
    • /
    • 2009
  • Among welfare facilities for the elderly, necessity for the elderly welfare with diverse advantages is rising in the Small-scale Elderly Care Facilities. The government is expecting great demand in the future. However, current the Facilities lack construction plans that consider characteristics of the elderly. Accordingly, 14 case facilities located in JeollaNamdo and Gwangju were selected to comprehensively analyze the circulation of seniors at care facilities by computing spatial depth and visible area variables. As a result of this study, average spatial depth of bathroom, resting room, physical therapy room and dining hall that seniors frequently get in contact with was found to be deep, but visible area appropriate for the function of space was not available. It showed that the circulation for the elderly was deep spatially and long physically, and the spatial rank along circulation which is perceived visually by the admitted the elderly was clear, thus, providing them abundant visual experience supported by high openness as they move from private space to public space. The obtained visibility, however, was observed not to be matched with the function of each space. Since the Small-scale Elderly Care Facilities require various spaces within small surface area, actual functions of each space must be taken into consideration with hierarchical space organization to obtain an environment that stimulates senses such as vision and hearing. In addition, since the circulation of seniors using facilities must consider aging characteristics and delicate care on spatial depth and physical distances, in-depth studies on planning of the circulation in care facilities are deemed necessary.

  • PDF

A Study on the Influential factors on Visitors' Satisfaction Level in Exhibition Space - Focused on the Seoul Living Design Fair 2005 - (전시 공간 디자인이 관람객 만족도에 미치는 영향에 관한 연구 - Seoul Living Design Fair 2005를 중심으로 -)

  • Choi, Jin-Hwa;Yoon, Ji-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.255-264
    • /
    • 2006
  • This study started from the premise that the satisfaction of visitors in large-scaled design-related fair has co-relation with the environmental and contextual factors such as contents, lighting, the number and location of rest area, crowdedness, ventilation and circulation. The research was made in Seoul Living Design Fair 2005. 102 samples from 132 who answered to the questionnaire with likert-scaled and open questions were selected for the data, which were statistically analyzed through SPSS 12.0 program to explore the co-relation between the environmental factors and the satisfaction level of visitors. The findings showed that overall satisfaction level was in the middle of the scale, which means satisfied nor unsatisfied. The visitors showed relatively high satisfaction in the two factors-the contents of the fair and lighting system compared to the other factors such as the number and location of rest area, sign system, ventilation crowdedness and circulation. Even though the visitors had difficulties in circulation and showed various types in circulation, it did not seem to have a significant influence on the overall satisfaction level because it might be offset by the contents of the fair. Also, the visitors showed similar satisfaction level regardless of the type of circulation. It can be concluded that the main factors mentioned above should be considered to achieve higher satisfaction level and provide better environment in the large-scaled fair.

A Model for Liquid Circulation Velocity in Airlift Reactors (공기부양반응기 내에서의 액체순환속도를 위한 모델)

  • Keun Ho Choi
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.446-455
    • /
    • 2023
  • A mathematical model for predicting the liquid circulation velocity in an airlift reactor was developed based on the mechanical energy balance of the fluid circulation loop. The model considered the energy loss due to a 90° turn, the energy loss due to friction, and the energy loss due to the change in cross-sectional area at each part of the reactor. The model that separately considered the loss coefficients related to friction, direction change, and cross-sectional area change was able to predict the liquid circulation velocity better than the previous model using lumped parameters. The liquid circulation velocity was measured by the tracer pulse method. Most of our experimental results obtained in external-loop airlift reactors, which had the top and bottom connecting pipes, as well as other investigators' results obtained in various types of airlift reactors, were well predicted by the developed model with an error within 20%. Useful empirical equations for the loss coefficient related to the 90° turn of the circulating fluid were obtained in external and internal-loop airlift reactors and used to predict the liquid circulation velocity.

Characteristics of Circulation Region of the Daily Living Information Newspaper Corporation in Korea (생활정보신문 사업체의 배포지역 특성)

  • 정은숙;한주성
    • Journal of the Korean Geographical Society
    • /
    • v.37 no.1
    • /
    • pp.41-60
    • /
    • 2002
  • It has been ten years since Daily Living Information Newspapers are first circulated as an useful local information source for everyday life in Korea. The circulation region is formed by the population size according to each type and sometimes, everyday life space across the boundaries of metropolitan area or province. The Daily Living Information Newspapers published in the area where corporations are located are distinguished from the others by region-attached advertisements. And their circulation regions of them are more detailed.