• 제목/요약/키워드: Circular Contact

검색결과 186건 처리시간 0.02초

Using Hyperspectral Fluorescence Spectra of Deli Commodities to Select Wavelengths for Surveying Deli Food Contact Surfaces

  • Lefcourt, Alan M.;Beck, Elizabeth A.;Lo, Y. Martin;Kim, Moon S.
    • Journal of Biosystems Engineering
    • /
    • 제40권2호
    • /
    • pp.145-152
    • /
    • 2015
  • Purpose: The inability to adequately judge the efficacy of cleaning and sanitation procedures in deli departments is a recognized food safety concern. In a prior study, our research group demonstrated that visual inspection of cleaned produce processing surfaces could be enhanced through the use of a portable fluorescence imaging device that detected residual produce residues. Methods: To explore the feasibility of using fluorescence imaging to similarly detect residual deli residues, spectra of American, Cheddar, Provolone, and Swiss cheeses and of processed chicken, ham, roast beef, and turkey were acquired using a laboratory hyperspectral imaging system. Circular punches of these commodities were placed onto stainless steel and high density polyethylene coupons for imaging. The coupon materials were selected to represent common surfaces found in deli departments. Results: Analysis of hyperspectral fluorescence images showed that cheeses exhibited peaks in the blue-green region and at around 675 nm. Meats exhibited peaks in the blue-green region with one of four ham and one of four chicken brands exhibiting peaks at around 675 nm, presumably due to use of plant-derived additives. When commodities were intermittently imaged over two weeks, locations of spectral peaks were preserved while intensity of peaks at shorter wavelengths increased with time. Conclusion: These results demonstrate that fluorescence imaging techniques have the potential to enhance surface hygiene inspection in deli departments and, given the immediate availability of imaging results, to help optimize routine cleaning procedures.

효율적인 인체신호 검출을 위한 안테나 특성 연구 (A Study on Antenna Characteristics for Efficiently Detecting Human Sign)

  • 장동원;최재익
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 추계학술대회
    • /
    • pp.484-487
    • /
    • 2014
  • 본 논문에서는 근거리에서 심박동, 호흡, 맥박 등 인체 신호를 효율적으로 검출할 수 있는 소출력 안테나 특성에 대하여 분석하였다. 이러한 환경에서 안테나는 펄스 신호를 사용하므로 광대역에서 임피던스가 주파수에 안정적인 특성이 요구된다. 이러한 요구 특성은 이득과 trade-off 관계가 있으나 본 논문에서는 근거리에서 사용하므로 방향성 및 이득을 높이기 위한 어레이 형태는 고려하지 않았다. 일반적으로 이러한 요구 사항을 만족하는 안테나는 주파수 독립(Frequency Independent) 안테나로 분류된다. 스파이럴(spiral), 시뉴어스(sinuous), 대수 주기(log-periodic) 안테나 등이 해당되며 소형으로 구현될 수 있다. 본 논문에서는 중심 주파수가 5 GHz인 UWB 펄스 트랜시버에 원형 패치 안테나와 시뉴어스 안테나를 접속하고 시험한 결과를 분석해서 기술하였다.

  • PDF

Vibration analysis of sandwich sector plate with porous core and functionally graded wavy carbon nanotube-reinforced layers

  • Feng, Hongwei;Shen, Daoming;Tahouneh, Vahid
    • Steel and Composite Structures
    • /
    • 제37권6호
    • /
    • pp.711-731
    • /
    • 2020
  • This paper deals with free vibration of FG sandwich annular sector plates on Pasternak elastic foundation with different boundary conditions, based on the three-dimensional theory of elasticity. The plates with simply supported radial edges and arbitrary boundary conditions on their circular edges are considered. The influence of carbon nanotubes (CNTs) waviness, aspect ratio, internal pores and graphene platelets (GPLs) on the vibrational behavior of functionally graded nanocomposite sandwich plates is investigated in this research work. The distributions of CNTs are considered functionally graded (FG) or uniform along the thickness of upper and bottom layers of the sandwich sectorial plates and their mechanical properties are estimated by an extended rule of mixture. In this study, the classical theory concerning the mechanical efficiency of a matrix embedding finite length fibers has been modified by introducing the tube-to-tube random contact, which explicitly accounts for the progressive reduction of the tubes' effective aspect ratio as the filler content increases. The core of structure is porous and the internal pores and graphene platelets (GPLs) are distributed in the matrix of core either uniformly or non-uniformly according to three different patterns. The elastic properties of the nanocomposite are obtained by employing Halpin-Tsai micromechanics model. A semi-analytic approach composed of 2D-Generalized Differential Quadrature Method (2D-GDQM) and series solution is adopted to solve the equations of motion. The fast rate of convergence and accuracy of the method are investigated through the different solved examples. Some new results for the natural frequencies of the plate are prepared, which include the effects of elastic coefficients of foundation, boundary conditions, material and geometrical parameters. The new results can be used as benchmark solutions for future researches.

Embedding Cobalt Into ZIF-67 to Obtain Cobalt-Nanoporous Carbon Composites as Electrode Materials for Lithium ion Battery

  • Zheng, Guoxu;Yin, Jinghua;Guo, Ziqiang;Tian, Shiyi;Yang, Xu
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권4호
    • /
    • pp.458-464
    • /
    • 2021
  • Lithium ion batteries (LIBs) is a kind of rechargeable secondary battery, developed from lithium battery, lithium ions move between the positive and negative electrodes to realize the charging and discharging of external circuits. Zeolitic imidazolate frameworks (ZIFs) are porous crystalline materials in which organic imidazole esters are cross-linked to transition metals to form a framework structure. In this article, ZIF-67 is used as a sacrificial template to prepare nano porous carbon (NPC) coated cobalt nanoparticles. The final product Co/NPC composites with complete structure, regular morphology and uniform size were obtained by this method. The conductive network of cobalt and nitrogen doped carbon can shorten the lithium ion transport path and present high conductivity. In addition, amorphous carbon has more pores that can be fully in contact with the electrolyte during charging and discharging. At the same time, it also reduces the volume expansion during the cycle and slows down the rate of capacity attenuation caused by structure collapse. Co/NPC composites first discharge specific capacity up to 3115 mA h/g, under the current density of 200 mA/g, circular 200 reversible capacity as high as 751.1 mA h/g, and the excellent rate and resistance performance. The experimental results show that the Co/NPC composite material improves the electrical conductivity and electrochemical properties of the electrode. The cobalt based ZIF-67 as the precursor has opened the way for the design of highly performance electrodes for energy storage and electrochemical catalysis.

LABORATORY STUDIES ON MIC OF AISI TYPE 304 STAINLESS STEEL USING BACTERIA ISOLATED FROM A W ASTEWATER TREATMENT SYSTEM

  • Sreekumari, Kurissery R.;Kyozo, Hirotani;Katsuya, Akamatsu;Takashi, Imamichi;Yasushi, Kikuchi
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.260-265
    • /
    • 2002
  • Microbiologically influenced Corrosion (MIC) is one of the most deleterious effects of metal microbe interactions. When a fresh metal surface comes in contact with a non-sterile fluid, biofilm formation is ensued. This might result in the initiation of corrosion. The sites and materials where MIC is implicated are versatile. Industries such as shipping, power generation, chemical etc are reported to be affected. The rapid and unexpected failure of AISI type 304 stainless steel was investigated in the laboratory by simulation studies for a period of 4 months. Slime and water samples from the failure site were screened for corrosion causing bacteria. Both aerobic and anaerobic nora were enumerated and identified using PCR techniques. Pseudomonas sp. and Bacillus sp. were the most common aerobic bacteria isolated from the water and slime samples, whilst sulfate reducing bacteria (SRB) were the major anaerobic bacteria. The aerobic bacteria were used for the corrosion experiments in the laboratory. Coupon exposure studies were conducted using a very dilute (0.1%V/V) nutrient broth medium. The coupons after retrieval were observed under a Scanning Electron Microscope (SEM) for the presence of MIC pits. Compared to sterile controls, metal coupons exposed to Pseudomonas sp and Bacillus sp. showed the initiation of severe pitting corrosion. However, amongst these two strains, Psudomonas sp. caused pits in a very short span of 14 days. Towards the end of the experiment, severe pitting was observed in both the cases. The detailed observation of pits showed they vary both in number and shapes. Whilst the coupons exposed to Bacillus sp. showed widely spread scales like pits, those exposed to Pseudomonas sp. showed smaller and circular pits, which had grown in number and size by the end of the experiment. From these results it is inferred that the rapid and unexpected failure of 304 SS might be due to MIC. Pseudonwnas sp. could be considered as the major responsible bacteria that could initiate pits in the metallic structures. As the appearance of pits was different in both the tested strains, it was thought that the mechanisms of pit formation are different. Experiments on these lines are being continued.

  • PDF

높이조절이 가능한 강재 맨홀뚜껑의 개발 (The Development of Height Adjustable Steel Manhole cover)

  • 박우철
    • 한국산학기술학회논문지
    • /
    • 제19권6호
    • /
    • pp.581-586
    • /
    • 2018
  • 주철 맨홀뚜껑은 제조과정에서 환경오염을 유발하며, 작업환경은 매우 열악하다. 또한, 맨홀 뚜껑의 높이와 도로 표면의 높이가 일치하지 않은 경우에는 많은 불편을 초래하며 안전에도 문제를 야기한다. 본 연구에서는 주철 맨홀뚜껑을 대체할 수 있고, 도로 노면 공사 시 도로 노면 높이와 맨홀 뚜껑의 높이를 동일하게 맞추기 용이한 높이 조절이 가능한 강재 맨홀 뚜껑 구조를 제안하였다. 요구되는 품질 성능을 만족시키기 위한 맨홀 뚜껑의 구조에 대한 설계변수를 파악하기 위하여 구조 해석을 수행하였다. 요구되는 내하중 용량을 만족하는 맨홀뚜껑을 제작하기 위하여 ㄷ자 모양의 보강대에 대하여 최적 설계를 수행하였다. 높이조절부의 원통과 하부 프레임 원통은 강판을 굽힘 가공하여 원형의 형상으로 만든 후 용접에 의하여 제작하였다. 또한, 보강대도 강판을 굽힘 가공하여 제작하였다. 높이 조절용 홈은 CNC 밀링머신에 의하여 가공하였다. 4차례의 시제품을 제작하여 내하중 실험을 수행하였으며, 시험의 결과를 반영하여 새로이 제작하였다. 내하중 시험에서 용접부의 파손은 발생하지 않았으며, 주로 변형은 높이조절 홈과 가셋트 판이 접촉하는 부위에서 발생하였다. 450kN의 부하 하중에 의해 1~2.7mm의 변형이 발생하지만, 하중을 제거한 후에 거의 잔류변형이 없으며, 맨홀뚜껑의 분해 및 재조립이 가능하기 때문에 내하중 평가도 만족하는 것으로 판정받았다.