• 제목/요약/키워드: Circular Column

검색결과 328건 처리시간 0.024초

Structural analysis of circular UHPCC form for hybrid pier under construction loads

  • Wu, X.G.;Zhao, X.Y.;Han, S.M.
    • Steel and Composite Structures
    • /
    • 제12권2호
    • /
    • pp.167-181
    • /
    • 2012
  • Ultra high performance cementitious composite material is applied to the design of multifunctional permanent form for bridge pier in this paper. The basic properties and calculating constitutive model of ultra high performance cementitious composite are introduced briefly. According to momental theory of thin-walled shell, the analytical solutions of structural behavior parameters including circumferential stress, longitudinal stress and shear stress are derived for UHPCC thin-walled circular tube. Based on relevant code of construction loads (MHURD of PPC 2008), the calculating parameter expression of construction loads for UHPCC thin-walled circular tube is presented. With geometrical dimensions of typical pier, the structural behavior parameters of UHPCC tube under construction loads are calculated. The effects of geometrical parameters of UHPCC tube on structural behavior are analyzed and the design advices for UHPCC tube are proposed. This paper shall provide a scientific reference for UHPCC permanent form design and UHPCC hybrid structure application.

Structural behavior of CFRP strengthened concrete-filled steel tubes columns under axial compression loads

  • Park, Jai Woo;Choi, Sung Mo
    • Steel and Composite Structures
    • /
    • 제14권5호
    • /
    • pp.453-472
    • /
    • 2013
  • This paper presents the structural behavior of CFRP (carbon fiber reinforced polymer) strengthened CFT (concrete-filled steel tubes) columns under axial loads. Circular and square specimens were selected to investigate the retrofitting effects of CFRP sheet on CFT columns. Test parameters are cross section of CFT, D/t (B/t) ratios, and the number of CFRP layers. The load and ductility capacities were evaluated for each specimen. Structural behavior comparisons of circular and rectangular section will be represented in the experimental result discussion section. Finally, ultimate load formula of CFRP strengthened CFT will be proposed to calculate the ultimate strength of CFRP strengthened circular CFT. The prediction values are in good agreement with the test results obtained in this study and in the literature.

원형 강관 삽입 중공 RC 기둥의 내부구속 효과 연구 (Confining Effect of an Internal Steel Tube in a Circular Hollow RC Column)

  • 한택희;김홍중;김영종;강영종
    • 대한토목학회논문집
    • /
    • 제26권4A호
    • /
    • pp.565-575
    • /
    • 2006
  • 구속된 콘크리트는 구속되지 않은 콘크리트에 비해 상당히 큰 강도를 갖는다. 따라서 콘크리트의 구속응력을 증가시키는 것은 강도의 증가를 유도할 수 있다. 하지만 중공교각의 경우, 심부구속력의 부재로 인하여 중공교각의 안쪽면에서 취성파괴가 발생하며, 이는 기둥의 강도 저하 및 연성의 저하를 초래한다. 이러한 문제를 극복하기 위하여, 강관 삽입 중공 RC(Reinforced Concrete) 기둥이 개발되었으며, 본 연구에서는 실험을 통하여 삽입 강관에 의한 내부 구속력의 효과를 검증하였다. 총 36개의 시험체를 제작하여 실험을 수행하였으며, 실험 결과를 통하여 삽입 강관의 구속력과 이로 인한 콘크리트의 강도 증가를 확인하였다.

이축반복하중을 받는 2주형 철근콘크리트 교각의 실험거동 (Experimental Behavior of Reinforced Concrete Column-Bent Piers under Bidirectional Repeated Loading)

  • 박창규;이범기;송희원;정영수
    • 한국지진공학회논문집
    • /
    • 제9권1호통권41호
    • /
    • pp.17-24
    • /
    • 2005
  • 기존의 RC 교각에 대한 내진성능 연구는 실험여건상 일방향 반복하중을 받는 단주교각에 집중되어 있었다. 그러나 고속도로상의 교각은 대다수가 다주교각으로 이루어져 있으므로, 본 연구에서는 국내고속도로에서 많이 사용되고 있는 2주형 교각에 대한 이축지진하중에서의 지진응답을 실험적으로 조사하였다. 실험체는 지름 400mm, 높이 2,000mm인 2주형 원형 교각 4기를 제작하였으며, $0.1f_{ck}A_g$크기의 축방향 하중작용하에서 횡방향 하중을 이축으로 교번반복 재하하였다. 실험변수는 횡구속 철근비와 주철근 겹침이음으로서 기존 단주에 대한 연구결과와 유사하게 이들 실험변수들은 교각의 내진성능에 상당한 영향을 미치고 있었다. 또한 동일하게 설계된 일축하중을 받는 단주와 이축하중을 받는 다주의 내진성능을 비교한 결과 단주의 경우 손상이 하부 소성힌지 한 곳에 집중된 반면 다주의 경우 교축직각방향 하중으로 인하여 손상이 상ㆍ하부 두 곳으로 분산되어 나타났다.

3차원 차분격자볼츠만 모델에의 내부자유도 적용 및 유동소음 모사 (Application of the Internal Degree of Freedom to 3D FDLB Model and Simulations of Aero-Acoustic)

  • 강호근;안수환;김정환
    • 대한조선학회논문집
    • /
    • 제43권5호
    • /
    • pp.586-596
    • /
    • 2006
  • A 3-dimensional FDLB model with additional internal degree of freedom is applied for diatomic gases such as air, in which an additional distribution function is introduced. Direct simulations of aero-acoustic by using the applied model and scheme are presented. Speed of sound is correctly recovered. As typical examples, the Aeolian tone emitted by a circular column is successfully simulated even very low Mach number flow. Acoustic pressure fluctuations with the same frequency of the Karman vortex street compared with the pressure fluctuation around a circular column is captured. Full three-dimensional acoustic wave past a compact block like pentagon, furthermore, is also emitted in y direction as dipole like sound.

600MPa급 고강도강 압축재의 좌굴강도에 관한 구조특성 (Structural Characteristics on the Buckling Strength for 600MPa Grade High Strength Steel Compression Members)

  • 이명재
    • 한국강구조학회 논문집
    • /
    • 제22권6호
    • /
    • pp.609-616
    • /
    • 2010
  • 이 논문은 600MPa급 고강도강이 원형강관 건축구조용으로 이용될 때 중심압축재의 좌굴강도에 관하여 수치해석적으로 조사한 것이다. 600MPa급 고강도강의 소재인장시험 결과로부터 중심압축재의 좌굴강도를 산정하였으며, 좌굴강도 산정에는 Beam-Column이론에 근거한 방법과 Tangent Modulus 이론에 의한 양자의 방법을 이용하였다. 그리고 소성흐름이 없는 인장시험의 응력-변형도 관계를 비례한도의 크기와 비례한도에서 항복점에 이르는 접선계수의 기울기로 근사시키고 좌굴강도 미치는 영향인자를 조사하였다. 600MPa급 고강도강에 적용되는 현재의 건축기준은 압축재의 경우 항복강도 Fy값을 480Mpa 까지 상향조정하여도 무리가 없다고 사료된다.

Boundary Conditions and Fire Behavior of Concrete Filled Tubular Composite Columns

  • Rodrigues, Joao Paulo C.;Correia, Antonio J.M.;Kodur, Venkatesh
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.313-325
    • /
    • 2018
  • Concrete-filled steel tubular (CFST) members are commonly used as composite columns in modern construction. However, the current guidelines for members' fire design (EN1994-1-2) have been proved to be unsafe in case the relative slenderness is higher than 0.5. In addition, the simplified design methods of Eurocode 4 are limited to circular and square CFST columns, while in practice columns with rectangular and elliptical hollow sections are being increasingly used because of their architectural aesthetics. In the last years a large experimental research has been carried out at Coimbra University on the topic. They have been tested concrete filled circular, square, rectangular and elliptical hollow columns with restrained thermal elongation. Some parameters such as the slenderness, the type of cross-section geometry as well as the axial and rotational restraint of the surrounding structure to the column have been tested in order to evaluate their influence on the fire resistance of such columns. In this paper it is evaluated the influence of the boundary conditions (pin-ended and semi-rigid end-support conditions) on the behavior of the columns in case of fire. In these tests it could not be seen a marked effect of the tested boundary conditions but it is believed that the increasing of rotational stiffness increases the fire resistance of the columns.

Experimental investigations on seismic responses of RC circular column piers in curved bridges

  • Jiao, Chiyu;Li, Jianzhong;Wei, Biao;Long, Peiheng;Xu, Yan
    • Earthquakes and Structures
    • /
    • 제17권5호
    • /
    • pp.435-445
    • /
    • 2019
  • The collapses of curved bridges are mainly caused by the damaged columns, subjected to the combined loadings of axial load, shear force, flexural moment and torsional moment, under earthquakes. However, these combined loadings have not been fully investigated. This paper firstly investigated the mechanical characteristics of the bending-torsion coupling effects, based on the seismic response spectrum analysis of 24 curved bridge models. And then 9 reinforced concrete (RC) and circular column specimens were tested, by changing the bending-tortion ratio (M/T), axial compression ratio, longitudinal reinforcement ratio and spiral reinforcement ratio, respectively. The results show that the bending-torsion coupling effects of piers are more significant, along with the decrease of girder curvature and the increase of pier height. The M/T ratio ranges from 6 to 15 for common cases, and influences the crack distribution, plastic zone and hysteretic curve of piers. And these seismic characteristics are also influenced by the compression ratio, longitudinal reinforcement ratio and spiral reinforcement ratios of piers.

Buckling analysis of linearly tapered micro-columns based on strain gradient elasticity

  • Akgoz, Bekir;Civalek, Omer
    • Structural Engineering and Mechanics
    • /
    • 제48권2호
    • /
    • pp.195-205
    • /
    • 2013
  • The buckling problem of linearly tapered micro-columns is investigated on the basis of modified strain gradient elasticity theory. Bernoulli-Euler beam theory is used to model the non-uniform micro column. Rayleigh-Ritz solution method is utilized to obtain the critical buckling loads of the tapered cantilever micro-columns for different taper ratios. Some comparative results for the cases of rectangular and circular cross-sections are presented in graphical and tabular form to show the differences between the results obtained by modified strain gradient elasticity theory and those achieved by modified couple stress and classical theories. From the results, it is observed that the differences between critical buckling loads achieved by classical and those predicted by non-classical theories are considerable for smaller values of the ratio of the micro-column thickness (or diameter) at its bottom end to the additional material length scale parameters and the differences also increase due to increasing of the taper ratio.

스티프너로 보강한 콘크리트 충전 원형 강관기둥의 부착응력에 관한 실험적 연구 (An Experimental Study on a Bond Stress in Concrete Filled Circular Steel Tubular Column Strengthened by the Stiffener)

  • 박성무;김성수;김원호;이형석
    • 한국공간구조학회논문집
    • /
    • 제2권2호
    • /
    • pp.51-58
    • /
    • 2002
  • This paper is presented an experimental studies on bond stress between steel and concrete in concrete filled steel tubes. In the actual building frames, vertical dead and live loads on beams are usually transferred to columns by beam-to-column connections. In case when concrete filled steel tubes are used as columns of an actual building frame which has a simple connection, shear forces in the beam ends are not directly transferred to the concrete core but directly to the steel tube. Provided that the bond effect between steel tube and concrete core should not be expected, none of the end shear in the beams would be transferred to the concrete core but only to the steel tube. Therefore, it is important to investigate the bond strength between steel tube and concrete core in the absence of shear connectors.

  • PDF