• Title/Summary/Keyword: Circuit interrupter

Search Result 100, Processing Time 0.023 seconds

Development of VCB Driving Mechanism using Permanent Magnetic Actuator (자기 액츄에이터를 이용한 진공차단기 구동 메카니즘 개발)

  • 최명준;석복렬;김창욱;최영찬;박일한
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.8
    • /
    • pp.381-389
    • /
    • 2003
  • Nowadays, Vacuum Circuit Breaker(VCB) is used in the most medium voltage level because vacuum has environment-friendly characteristics as well as excellent dielectric strength. In order to elevate the breaking performance, the improvement of vacuum interrupters and the driving mechanism should be proceeded. In this paper, the development of a Permanent Magnet Actuator could replace the mechanical spring mechanism which is the driving mechanism of existing VCB. The holding force and opening characteristics of magnetic actuator are analysed with FEM and the result is verified through experiment.

Design and Implementation of a ZigBee Nework-based Integrated AFCI (지그비 네트워크 기반 복합형 AFCI 설계 및 구현)

  • Chang, Ki-Heung;Kim, Kee-Min;Kim, Jae-O;Ahn, Hyun-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.41-48
    • /
    • 2010
  • In this paper, a new type of integrated AFCI is designed and implemented by combining individual circuit breaker characteristics, which can effectively detect arc fault signals in real-time. The proposed integrated AFCI satisfies the UL1699, the USA certification standard, and the Korean circuit breaker standards such as KS C4613 and KS C8321. Data signals are transferred to the management server via ZigBee network to analyze dangerous factors and to prevent unwanted trip. It is also shown by experiments that arc fault signals are detected and analyzed by using the integrated AFCI with ZigBee networks.

A System IC for Controlling the Fire Prevention (화재방지제어 시스템 IC)

  • Kim, Byung-Cheul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.737-746
    • /
    • 2009
  • In this study, we have developed one chip system IC for preventing the overload, detecting an abnormal conditions, and controlling the fire prevention in the intelligent home appliances. For the purpose, a circuit detectable an electric leak for preventing an electric shock, and a circuit detectable arc that has effect directly on the fire are designed. The circuits designed on every block are verified by comparing simulation with bread-boarding using a standard transistors. The system IC is fabricated by using 34 V 2 metal $1.5{\mu}m$ bipolar transistor process from evaluation results. The electrical performances of IC application circuits and the system IC equipped on PCB board are evaluated. It is confirmed that the system IC is well operated for arc and ground fault(GF) signal.

Development of Model Interrupter of 7.2kV $SF_6$ Gas Electromagnetic Contactor Using Rotary Arc Principle (7.2kV급 로타리아크식 $SF_6$가스 전자접촉기 소호부 개발연구)

  • Chang, K.C.;Shin, Y.J.;Park, K.P.;Chong, J.K.;Kim, J.K.;Kim, G.S.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.30-32
    • /
    • 1995
  • The model interrupters of $SF_6$ gas electromagnetic contactor whose ratings are the voltage of 7.2kV and the short circuit current of 4.0kA have been designed and manufactured on the basis of theoretical and computational analysis for its development. The eddy current analysis, the magnetic field analysis and the calculation of the rotational force on arcs have been conducted using FLUX2D package. The short circuit current interrupting tests have been conducted to the model interrupters using the simplified capacitive synthetic test circuit in KERI. The results show that the model interrupters have a sufficient interrupting capability and the new design concept is proper for a good interrupting performance.

  • PDF

An Analysis of Cold Gas Flow-Field for UHV Class Interrupters (초고압 가스차단부의 냉가스 유동해석)

  • Song, Gi-Dong;Park, Gyeong-Yeop;Song, Won-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.6
    • /
    • pp.387-394
    • /
    • 2000
  • This paper presents a method of cold gas flow-field analysis within puffer type GCB(Gas Circuit Breaker). Using this method, the entire interruption process including opening operation of GCB can be simulated successfully. In particular, the distortion problem of the grid due to the movement of moving parts can be dealt with by the fixed grid technique. The gas parameters such as temperature, pressure, density, velocity through the entire interruption process can be calculated and visualized. It was confirmed that the time variation of pressure which was calculated from the application of the method to a model GCB agreed with the experimental one. Therefore it is possible to evaluate the small current interruption capability analytically and to design the interrupter which has excellent interruption capability using the proposed method. It is expected that the proposed method can reduce the time and cost for development of GCB very much. It also will be possible to develop the hot-gas flow-field analysis program by combining the cold-gas flow field program with the arc model and to evaluate the large current interruption capability.

  • PDF

A Study on Rotor Position Detection and Securing Initial Position for Switched Reluctance Motor (SRM) (스위치드 릴럭턴스 전동기 (SRM) 회전자 위치 검출 및 초기 위치확보 연구)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.3
    • /
    • pp.141-146
    • /
    • 2020
  • In brushless DC motors (BLDC), the on/off angle of the switch is determined by the optimal alignment of the stator and rotor, while switched reluctance motors (SRM) are complex parameters with many on/off angles of the switch. It appears as a function and therefore the switching angle is variable for optimal operation. Therefore, in order to operate the switched reluctance motor (SRM) optimally, the rotor position can be detected using a high resolution position sensor and a complicated additional circuit. In this paper, rotor position detection and related position detection circuits are applied and detected by using various sensors such as encoder, hall sensor and opto interrupter among several methods to drive switched reluctance motor (SRM). Also a study on securing the initial position of the rotor was conducted.

Arc Fault Circuit Interrupter Design using Microprocessor (마이크로프로세서를 이용한 아크결함 차단기 설계)

  • Yoon, Kwang-Ho;Ban, Gi-Jong;Lee, Hyo-Jik;Park, Byung-Suk;Nam, Moon-Hyon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.12-18
    • /
    • 2007
  • As an arc fault interrupter, the AFCI mentioned in this paper has been designed to detect and interrupt arc faults due to wire deterioration, insulation, wire damage, loose connection, and excessive mechanical damage. Since AFCI is digital and uses mechanical and electric stress, the length of interruption against overload and over-current is much shorter than the current bi-metal method. Therefore, the risk of electrical fires has been reduced.

Series Arc Wave Analysis and Detection Algorithm (직렬아크 파형 분석 및 검출 알고리즘)

  • Kwon, Wan-Sung;Choi, Su-Kyung;Bang, Sun-Bae;Kim, Chong-Min;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.240-242
    • /
    • 2009
  • 현재 미국에서는 전기화재를 예방하기 위한 AFCI(Arc Fault Circuit Interrupter) 설치가 법으로 제정되어 보급되고 있으며 이에 대한 기준인 UL1699가 제정되어 있다. 본 논문에서는 UL1699의 규정에 기반한 직렬아크발생장치를 통하여 여러 가정용 부하에서 발생시킨 아크의 전류파형들을 주파수영역과 이산 웨이블렛을 이용하여 분석해보고 그에 따른 검출 알고리즘을 제안하고자 한다.

  • PDF

Research on Necessity of Arc Fault Circuit Interrupter (아크차단기의 필요성에 관한 연구)

  • Park, Chee-Hyun;Bae, Suk-Myeong;Lim, Yong-Bae;Kim, Gi-Hyun;Choi, Myung-II
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.450-453
    • /
    • 2007
  • 전력사용이 증가함에 따라 전기설비에 의한 전기화재 수가 늘어나고 있다. 통계에 따르면 전기화재가 화재원인 중 가장 많은 비중을 차지하고 있음을 알 수 있다. 그럼에도 불구하고 전기화재를 정확히 찾아낼 수 있는 조사기법이 개발되지 않고 있는 실정이다. 이 논문은 전기화재 원인과 아크차단기의 특성에 관하여 분석한다. 아크에 의한 위험을 수학적 분석을 이용한 전력계산을 통하여 분석하고 단락회로에 의한 위험성과 비교한다. 또한 아크차단기와 기존의 누전차단기와 비교를 통하여 아크차단기의 필요성을 제기한다.

  • PDF

A Study on the Temperature Compensation of ASIC for AFCI (AFCI용 ASIC의 온도보상에 관한 연구)

  • Yang, Seung-Kook;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.109-113
    • /
    • 2013
  • In order to avoid the electrical fire, AFCI(Arc Fault Cirruit Interrupter) has been obligated to be adopted in the United States of America since 2002. AFCI using line resistor of neutral trace needs to compensate the variation of the line resistance by temperature variation. In this paper, the ASIC including the temperature compensation circuit is implemented. The proposed implementation is verified by showing the effectiveness of an electric and a temperature characteristics for Arc signals by simulation results.