전기철도 교/직 절연구분장치의 절연열화 현상 (Insulation Deterioration of AC/DC Section Insulators for Electric Railroad Catenary.)

  • 최규형
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권1호
    • /
    • pp.16-22
    • /
    • 2003
  • While passing through the AC/DC section insulators installed at electric railroad catenary, some electric trains undergo mis-operation of main circuit breaker after AC/DC change-over operation. This paper provides insulation resistance measurements of AC/DC section insulators, which confirm the insulation levels of section insulators are below the standard of insulators. The insulation deterioration and pantograph arrangement on the electric train can produce voltage impression on section insulator which induces mis-operation of main circuit breaker To mitigate the insulation deterioration of the section insulator installed at underground railroads, the section insulators have been cleaned periodically, but section insulator structure should be modified to make the section insulator performance perfect. Based on the above analysis, effective modification method of AC/DC section insulator is provided.

Corrugate 휜-관 현열 열교환기의 구조에 따른 공기측 열전달 및 압력손실 특성 (Characteristic of air-side sensible heat transfer and pressure drop on the corrugate fin tube heat exchangers)

  • 류준일;전창덕;이진호;남임우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.216-221
    • /
    • 2007
  • An experiment was carried out to investigate the effect of a coolant circuit arrangement on the heat transfer and air pressure drop of a fin-tube sensible heat exchanger with the corrugated fin surface. The air inlet temperature was set to $23^{\circ}C$,the relative humidity to 50% and the air inlet flow rate to 20, 22, $25m^3/min$, respectively. while the coolant temperature was set to $7^{\circ}C$, and the coolant mass flow rate to 10, 16, 22kg/min, respectively. Experiment showed that the exchanger having a diameter of 12.7mm with parallel circuit does better performance in sensible heat transfer and air pressure drop than those three of diameter of 12.7mm with a series circuit and that with diameter of 15.88mm with a parallel circuit.

  • PDF

냉각수 변화에 따른 멀티패스 밀폐식 냉각탑의 성능 (Characteristics of Closed Circuit Cooling Tower with Multi Path on Cooling Water Inlet Conditions)

  • 심규진;백승문;문춘근;윤정인;김은필;권오익
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.597-602
    • /
    • 2008
  • The experiment of performance about closed-wet cooling tower(CWCT) was conducted in this study. The test section has the cooling water that flows from top part of a heat exchanger that has an entrance of cooling water with one and multi path. The heat exchanger consists of 15.88mm tubes with ten rows and ten columns and staggered arrangement. In this experiment, heat and mass transfer coefficients and range are calculated with variations of cooling water and path. The results indicated that operating CWCT using two path have the high values of heat and mass transfer coefficients and range than one path.

  • PDF

전통재래시장 상가간의 구역 구분에 따른 화재강도 분석 (Analysis of Fire Intensity According to the Zones Classification in Traditional Market Stores)

  • 김태권
    • 한국산학기술학회논문지
    • /
    • 제21권6호
    • /
    • pp.154-160
    • /
    • 2020
  • 본 연구에서는 화재시뮬레이션을 이용하여 전통재래시장 상가 간 내연성 구획 벽 설치에 따른 화재강도 분석을 실시하였다. 대구 서문시장 4지구 상가 일부분을 대상으로 모델링을 실시하였으며 섬유, 의류와 같은 가연물을 통로 인근에 배치하여 2016년 화재발생 당시와 유사한 조건으로 해석을 진행하였다. 최초발화지점은 4번째 상가 적치물에서 전기합선에 의해 발생한 것으로 가정하였다. 구획 벽이 없는 경우 최초발화지점에서 방사형태로 급속도로 화재가 전파되며, 600초 이후 30 ㎡의 상가를 전소시켰다. 상가간 구획 벽을 설정한 경우 화재저항으로 인해 화재의 확산을 구획지역내부로 한정시킬 수 있었다. 열발생율이 급격히 상승하기 시작하는 200초(X1)에서 600초(X2)까지 총 발생한 열에너지를 통해 두 해석조건의 화재강도를 예측하였다. 결과적으로 본 연구에서 설정한 발화지점 인근의 구획 벽 설정을 통하여 해석한 결과 약 11.12 MW(55.68 %)의 열에너지 발생을 지연시킴을 확인하였다. 추후 구획 벽의 배치 및 재연설비 설치에 따른 연기제어에 대한 추가 해석을 수행함으로서 전통재래시장에서의 종합적인 화재특성 연구가 필요할 것으로 생각된다.