• Title/Summary/Keyword: Circuit Breaker

Search Result 690, Processing Time 0.026 seconds

Cold Flow Simulation of $SF_{6}$ Puffer Circuit Breaker

  • Bae, Chae-Yoon;Jung, Hyun-Kyo;Shin, Sang-In;Park, Oh-Hyun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.4
    • /
    • pp.121-128
    • /
    • 2001
  • Numerical schemes for the simulation of the cold gas flow in the SF6 puffer type circuit breaker is presented. The governing equation is axisymmetric compressible Euler Equation and FVM is used to analyze the behavior of flow. The upwind scheme is used to avoid numerical instability and MUSCL is used to obtain high order accuracy. For the efficient calculation, AF-ADI scheme is used. The simulation result shows good agreement with the experimental data.

  • PDF

Analysis and Design of Driving Mechanism of Hybrid RMU (복합 소호 방식 RMU 구동 메커니즘 해석 및 설계)

  • Kwon, Byung-Hee;Ahn, Kil-Young;Oh, Il-Sung
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.729-733
    • /
    • 2003
  • Hybrid RMU is a kind of power circuit breaker and protects electric devices from over-current. In this paper we built a dynamic model of RMU driving mechanism using ADAMS and performed a optimal design of several design parameters. Finally we developed a prototype of RMU driving mechanism through results of analysis and confirmed it to satisfy design requisitions.

  • PDF

EMTP Modeling of an Alterative Counter voltage (ACV) DC Hybrid Circuit Breaker (DC-HCB) (대체 카운터 전압(ACV) DC 하이브리드 회로 차단기(DC-HCB)의 EMTP 모델링)

  • Kazim, Raza Muhammad;Rhee, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.601-602
    • /
    • 2015
  • Interruption of AC is easier due to natural occuring of zero crossings. In DC, zero crossings is achieved by Forced commutation technique. In this paper an alternative counter voltage(ACV) DC Hybrid Circuit breaker(DC-HCB) is modeled using EMTP/ATP tool, Results show that, ACV DC-HCB can interrupt DC with in 5ms with a source voltage of upto 1 KV.

  • PDF

Analysis on Dynamic Characteristics of Air-Pressure Type Chamber in Puffer Circuit Breaker (공압식 조작기의 동작특성에 관한 해석)

  • Park, Sang-Hun;Bae, Chae-Yoon;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.18-20
    • /
    • 2002
  • In this paper, various forces generated in the Gas Circuit Breaker(GCB) such as operating force, repulsive force, spring force, and dashpot force are analyzed with the fluid properties and the mechanical structure. The operation of GCB can be understood. A stroke curve from the result of simulation is compared with experimental one.

  • PDF

The computer analysis of the virtual current chopping in the vacuum circuit breaker. (진공차단기의 가상전류 촙핑에 대한 컴퓨터 해석)

  • Kim, Kil-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.69-72
    • /
    • 1988
  • The work is concerned with the analysis of the voltage escalation caused by the repeated restriking and extinguishing of the current when the vacuum circuit breaker interrupts the arc furnace load current. The paper particularly concentrates on the protective measures that may be adopted to overcome the restriking problem and guidelines are evaluated.

  • PDF

Design requirements for Generator Circuit Breaker (원자력발전소의 발전기차단기 설계요건 검토)

  • Chi, Mun-Goo;Han, Sung-Heum
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.371-373
    • /
    • 2001
  • Main functions of Generator Circuit Breaker(GCB) is cut the generator off from the main transformers and the aux. transformers when plant trip or startup. In this paper, the design requirements For GCB of nuclear power plant is examined. NRC presented the area of review, acceptance criteria and review procedures of GCB in the SRP(Standard Review Plan). In Korea, APR1400 adapted the GCB in main power system.

  • PDF

Forced reclosing in transmission line (송전선의 강제재폐로)

  • 김준현
    • 전기의세계
    • /
    • v.29 no.6
    • /
    • pp.401-409
    • /
    • 1980
  • This paper deals with the implementation of forced reclosing the transmission line. Because the ground circuit breaker method decrease the secondary arc current sufficiently, the reclosing time can be reduced. As the secondary arc current is large and its residual time is long in UHV transmission line, this method is more effective in that system. The resistance of ground circuit breaker which minimize the secondary arc current is determined according to the system voltage and the length of transmission line.

  • PDF

The development of the HID Electronic Ballast for the street lamp with the leakage Current detection and circuit breaker function (누전검출 및 차단기능을 가진 가로등용 HID 전자식 안정기 개발)

  • Park, Chong-Yeun;Lim, Byoung-Noh;Choi, Won-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.99-102
    • /
    • 2006
  • We developed the electronic ballast for the street HID lames with the leakage current detection and circuit breaker function. By detecting the leakage current and breaking the system we are protected from the electric shock and the ballast is safe from the electric damage at the time of the continuous reignition state.

  • PDF