• 제목/요약/키워드: Cine

검색결과 105건 처리시간 0.033초

A New Method for Aortic Valve Planimetry with High-Resolution 3-Dimensional MRI and Its Comparison with Conventional Cine MRI and Echocardiography for Assessing the Severity of Aortic Valvular Stenosis

  • Hae Jin Kim;Yeon Hyeon Choe;Sung Mok Kim;Eun Kyung Kim;Mirae Lee;Sung-Ji Park;Joonghyun Ahn;Keumhee C. Carriere
    • Korean Journal of Radiology
    • /
    • 제22권8호
    • /
    • pp.1266-1278
    • /
    • 2021
  • Objective: We aimed to compare the aortic valve area (AVA) calculated using fast high-resolution three-dimensional (3D) magnetic resonance (MR) image acquisition with that of the conventional two-dimensional (2D) cine MR technique. Materials and Methods: We included 139 consecutive patients (mean age ± standard deviation [SD], 68.5 ± 9.4 years) with aortic valvular stenosis (AS) and 21 asymptomatic controls (52.3 ± 14.2 years). High-resolution T2-prepared 3D steady-state free precession (SSFP) images (2.0 mm slice thickness, 10 contiguous slices) for 3D planimetry (3DP) were acquired with a single breath hold during mid-systole. 2D SSFP cine MR images (6.0 mm slice thickness) for 2D planimetry (2DP) were also obtained at three aortic valve levels. The calculations for the effective AVA based on the MR images were compared with the transthoracic echocardiographic (TTE) measurements using the continuity equation. Results: The mean AVA ± SD derived by 3DP, 2DP, and TTE in the AS group were 0.81 ± 0.26 cm2, 0.82 ± 0.34 cm2, and 0.80 ± 0.26 cm2, respectively (p = 0.366). The intra-observer agreement was higher for 3DP than 2DP in one observer: intraclass correlation coefficient (ICC) of 0.95 (95% confidence interval [CI], 0.94-0.97) and 0.87 (95% CI, 0.82-0.91), respectively, for observer 1 and 0.97 (95% CI, 0.96-0.98) and 0.98 (95% CI, 0.97-0.99), respectively, for observer 2. Inter-observer agreement was similar between 3DP and 2DP, with the ICC of 0.92 (95% CI, 0.89-0.94) and 0.91 (95% CI, 0.88-0.93), respectively. 3DP-derived AVA showed a slightly higher agreement with AVA measured by TTE than the 2DP-derived AVA, with the ICC of 0.87 (95% CI, 0.82-0.91) vs. 0.85 (95% CI, 0.79-0.89). Conclusion: High-resolution 3D MR image acquisition, with single-breath-hold SSFP sequences, gave AVA measurement with low observer variability that correlated highly with those obtained by TTE.

Feasibility of Free-Breathing, Non-ECG-Gated, Black-Blood Cine Magnetic Resonance Images With Multitasking in Measuring Left Ventricular Function Indices

  • Pengfei Peng;Xun Yue;Lu Tang;Xi Wu;Qiao Deng;Tao Wu;Lei Cai;Qi Liu;Jian Xu;Xiaoqi Huang;Yucheng Chen;Kaiyue Diao;Jiayu Sun
    • Korean Journal of Radiology
    • /
    • 제24권12호
    • /
    • pp.1221-1231
    • /
    • 2023
  • Objective: To clinically validate the feasibility and accuracy of cine images acquired through the multitasking method, with no electrocardiogram gating and free-breathing, in measuring left ventricular (LV) function indices by comparing them with those acquired through the balanced steady-state free precession (bSSFP) method, with multiple breath-holds and electrocardiogram gating. Materials and Methods: Forty-three healthy volunteers (female:male, 30:13; mean age, 23.1 ± 2.3 years) and 36 patients requiring an assessment of LV function for various clinical indications (female:male, 22:14; 57.8 ± 11.3 years) were enrolled in this prospective study. Each participant underwent cardiac magnetic resonance imaging (MRI) using the multiple breath-hold bSSFP method and free-breathing multitasking method. LV function parameters were measured for both MRI methods. Image quality was assessed through subjective image quality scores (1 to 5) and calculation of the contrast-to-noise ratio (CNR) between the myocardium and blood pool. Differences between the two MRI methods were analyzed using the Bland-Altman plot, paired t-test, or Wilcoxon signed-rank test, as appropriate. Results: LV ejection fraction (LVEF) was not significantly different between the two MRI methods (P = 0.222 in healthy volunteers and P = 0.343 in patients). LV end-diastolic mass was slightly overestimated with multitasking in both healthy volunteers (multitasking vs. bSSFP, 60.5 ± 10.7 g vs. 58.0 ± 10.4 g, respectively; P < 0.001) and patients (69.4 ± 18.1 g vs. 66.8 ± 18.0 g, respectively; P = 0.003). Acceptable and comparable image quality was achieved for both MRI methods (multitasking vs. bSSFP, 4.5 ± 0.7 vs. 4.6 ± 0.6, respectively; P = 0.203). The CNR between the myocardium and blood pool showed no significant differences between the two MRI methods (18.89 ± 6.65 vs. 18.19 ± 5.83, respectively; P = 0.480). Conclusion: Multitasking-derived cine images obtained without electrocardiogram gating and breath-holding achieved similar image quality and accurate quantification of LVEF in healthy volunteers and patients.

셀프 동기를 이용한 심장자기공명 씨네영상법 (Self-gated MR cardiac CINE imaging)

  • 김판기;박진호;안창범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2039-2040
    • /
    • 2011
  • 자기공명영상에서 심장의 기능을 진단에 필요한 심장 영상을 얻기 위해서는 심장의 움직임을 모니터 할 수 있는 ECG나 pulse oximeter 등의 장비로 동기를 맞추어 주기위한 트리거 신호가 필요하다. 본 논문은 심장의 움직임을 다른 장비의 도움 없이 동기화하여 자기공명 심장 영상을 재구성하는 새로운 방법을 나선주사영상기법에 적용하여 제안하였다.

  • PDF

Quantitative Evaluation of the First Order Creatine-Kinase Reaction Rate Constant in in vivo Shunted Ovine Heart Treated with Oxandrolone Using Magnetization Transfer 31P Magnetic Resonance Spectroscopy (MT-31P-MRS) and 1 H/31P Double-Tuned Surface Coil: a Preliminary Study

  • Thapa, Bijaya;Dahl, Marjanna;Kholmovski, Eugene;Burch, Phillip;Frank, Deborah;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권1호
    • /
    • pp.26-36
    • /
    • 2018
  • Purpose: Children born with single ventricle physiology demonstrate poor growth rate and suffer from malnutrition, which lead to increased morbidity and mortality in this population. We assume that an anabolic steroid, oxandrolone, will promote growth in these infants by improving myocardial energy utilization. The purpose of this paper is to study the efficacy of oxandrolone on myocardial energy consumption in these infants. Materials and Methods: We modeled single ventricle physiology in a lamb by prenatally shunting the aorta to the pulmonary artery and then postnatally, we monitored cardiac energy utilization by quantitatively measuring the first order reaction rate constant, $k_f$ of the creatine-kinase reaction in the heart using magnetization transfer $^{31}P$ magnetic resonance spectroscopy, home built $^1H/^{31}P$ transmit/receive double tuned coil, and transmit/receive switch. We also performed cine MRI to study the structure and dynamic function of the myocardium and the left ventricular chamber. The spectroscopy data were processed using home-developed python software, while cine data were analyzed using Argus software. Results: We quantitatively measured both the first order reaction rate constant and ejection fraction in the control, shunted, and the oxandrolone-treated lambs. Both $k_f$ and ejection fraction were found to be more significantly reduced in the shunted lambs compared to the control lambs, and they are increased in oxandrolone-treated lambs. Conclusion: Some improvement was observed in both the first order reaction rate constant and ejection fraction for the lamb treated with oxandrolone in our preliminary study.

Relationship between Class III malocclusion and hyoid bone displacement during swallowing: a cine-magnetic resonance imaging study

  • Gokce, Sila Mermut;Gokce, Hasan Suat;Gorgulu, Serkan;Karacay, Seniz;Akca, Eralp;Olmez, Huseyin
    • 대한치과교정학회지
    • /
    • 제42권4호
    • /
    • pp.190-200
    • /
    • 2012
  • Objective: The displacement of the hyoid bone (HB) is a critical biomechanical component of the swallowing function. The aim of this study was to evaluate the swallowing-induced vertical and horizontal displacements of the HB in subjects with 2 different magnitudes of skeletal Class III malocclusion, by means of real-time, balanced turbo-field-echo (B-TFE) cine-magnetic resonance imaging. Methods: The study population comprised 19 patients with mild skeletal Class III malocclusion, 16 with severe skeletal Class III malocclusion, and 20 with a skeletal Class I relationship. Before the commencement of the study, all subjects underwent cephalometric analysis to identify the nature of skeletal malformations. B-TFE images were obtained for the 4 consecutive stages of deglutition as each patient swallowed 10 mL of water, and the vertical and horizontal displacements of the HB were measured at each stage. Results: At all stages of swallowing, the vertical position of the HB in the severe Class III malocclusion group was significantly lower than those in the mild Class III and Class I malocclusion groups. Similarly, the horizontal displacement of the HB was found to be significantly associated with the severity of malocclusion, i.e., the degree of Class III malocclusion, while the amount of anterior displacement of the HB decreased with an increase in the severity of the Class III deformity. Conclusions: Our findings indicate the existence of a relationship between the magnitude of Class III malocclusion and HB displacement during swallowing.

측두하악관절장애 환자에서의 static MRI와 pseudo-dynamic MRI의 비교연구 (Comparison of static MRI and pseudo-dynamic MRI in tempromandibular joint disorder patients)

  • 이진호;윤경인;박인우;최항문;박문수
    • Imaging Science in Dentistry
    • /
    • 제36권4호
    • /
    • pp.199-206
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate comparison of static MRI and pseudo-dynamic (cine) MRI in temporomandibular joint (TMJ) disorder patients. Materials and Methods: In this investigation, 33 patients with TMJ disorders were examined using both conventional static MRI and pseudo-dynamic MRI. Multiple spoiled gradient recalled acquisition in the steady state (SPGR) images were obtained when mouth opened and closed. Proton density weighted images were obtained at the closed and open mouth position in static MRI. Two oral and maxillofacial radiologists evaluated location of the articular disk, movement of condyle and bony change respectively and the posterior boundary of articular disk was obtained. Results: No statistically significant difference was found in the observation of articular disk position, mandibular condylar movement and posterior boundary of articular disk using static MRI and pseudo-dynamic MRI (P<0.05). Statistically significant difference was noted in bony changes of condyle using static MRI and pseudo-dynamic MRI (P<0.05). Conclusion: This study showed that pseudo-dynamic MRI didn't make a difference in diagnosing internal derangement of TMJ in comparison with static MRI. But it was considered as an additional method to be supplemented in observing bony change.

  • PDF

Earthquake performance evaluation of three-dimensional roller compacted concrete dams

  • Kartal, Murat Emre;Karabulut, Muhammet
    • Earthquakes and Structures
    • /
    • 제14권2호
    • /
    • pp.167-178
    • /
    • 2018
  • A roller compacted concrete (RCC) dam should be analyzed under seismic ground motions for different conditions such as empty reservoir and full reservoir conditions. This study presents three-dimensional earthquake response and performance of a RCC dam considering materially non-linearity. For this purpose, Cine RCC dam constructed in Aydın, Turkey, is selected in applications. The three-dimensional finite element model of Cine RCC dam is obtained using ANSYS software. The Drucker-Prager material model is considered in the materially nonlinear time history analyses for concrete and foundation rock. Furthermore, hydrodynamic effect was investigated in linear and non-linear dynamic analyses. Researchers observe that how the tensile and compressive stresses change by hydrodynamic pressure effect. The hydrodynamic pressure of the reservoir water is modeled with the fluid finite elements based on the Lagrangian approach. In this study, dam body and foundation are modeled with welded contact. The displacements and principle stress components obtained from the linear and non-linear analyses with and without reservoir water are compared each other. Principle stresses during earthquake were obtained at the most critical point in the upstream face of dam body. Besides, the change of displacements and stresses by crest length were investigated. Moreover demand-capacity ratio criteria were also studied under linear dynamic and nonlinear analysis. Earthquake performance analyses were carried out for different cases and evaluated. According to linear and nonlinear analysis, hydrodynamic water effect is obvious in full reservoir situation. On the other hand, higher tensile stresses were observed in linear analyses and then non-linear analyses were performed and compared with each other.

심장 자기공명영상 (Cardiac MRI)

  • 이종민
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권1호
    • /
    • pp.1-9
    • /
    • 2007
  • 심장의 영상화에 장애가 되는 요인은 심장 운동, 호흡, 심장 내 혈류 등에 의한 인공물(artifact) 과 심장 조직의 용적이 작음으로 인한 낮은 신호 대 잡음비 등이 있다. 심장 운동에 의한 화질 저하를 막기 위해 신속영상기법(fast imaging technique) 을 이용하여 심장 운동의 특정 위상(phase) 에서만 영상을 얻는 심장동기(cardiac gating) 방법을 이용하고 있다. MRI를 이용한 심장의 검사는 심장의 형태, 심실 기능, 심근 관류, 심근 대사, 관상동맥 영상 등을 대상으로 한다. 심장의 형태적 진단에 있어서 심근내 수분의 정도와 지방조직을 보기 위해 이중(double) 혹은 삼중역전회복기법(triple inversion recovery technique) 을 사용한다. 심근관류검사를 위해서는 조영증강신속경사에코법(contrast-enhanced fast gradient echo technique)을 사용하여 일차통과조영증강(first-pass enhancement) 을 검사한다. 또한 10-15분 지연영상을 얻어 심근내 조영제의 재분포를 검사하여 만성심근경색 등의 심근파괴부위를 확인한다. 심실기능 평가를 위해서는 신속경사에 코법을 이용한 영화영상(cine image) 이 사용되며 심실의 국소적 운동이상 및 심실기능의 정량적 검사가 가능하다. MRI는 관상동맥영상을 제외한 포괄적 심장검사에 실용성이 있다. 특히 지연영상은 다른 검사장비에선 얻을수 없는 유용한 정보이다.

  • PDF

디지털 영화제작을 위한 레드 원 카메라의 활용성 연구 (Using 'RED ONE' Camera for Digital Film Making)

  • 고현욱;민경원
    • 한국콘텐츠학회논문지
    • /
    • 제9권9호
    • /
    • pp.163-170
    • /
    • 2009
  • 본 논문은 새롭게 개발된 레드 원(RED ONE)카메라의 장단점들을 분석하고 분석된 자료를 기존 디지털 카메라와 비교 했다. 영화제작시스템이 디지털영화제작시스템으로 전환하면서 기존 필름카메라 회사인 Arriflex도 디지털 카메라인 Arri D21을 개발했고 고화질 디지털 카메라의 대명사인 Sony도 CineAlta F35를 통해 디지털 영화제작의 선도적인 역할을 수행하고 있다. 이러한 디지털 영화제작의 기술적 진보속에서 레드 원 카메라의 등장은 필름메이커들에게 새로운 가능성을 열어주고 있다. Arri 와 Sony 같이 긴 역사적 배경을 가진 회사와는 다르게 개발 시작부터 현재까지 디지털 영화제작 스테프들의 요구를 최대한 반영하여 디지털 카메라를 발전시킨다는 점이 레드 원만의 독특한 장점 중에 하나일 것이다. 사용자를 배려한 디지털카메라의 개발은 영화제작 환경에 파급효과를 가져왔으며 상업용 디지털영화제작을 주도하게 된 중요한 요인이 되었다.

좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가 (Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients)

  • 조재영;배선명;윤인하;이호연;강태영;백금문;배재범
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.297-303
    • /
    • 2014
  • 목 적 : Deep inspiration breath-hold(DIBH) 기법을 이용한 좌측 유방암의 방사선치료 중 환자의 호흡과 심장 위치의 변화에 대한 분석을 통해 DIBH 기법의 치료 재현성을 평가하고자 한다. 대상 및 방법 : 유방보존수술 후 DIBH 기법을 적용한 좌측 유방암 환자 3명을 대상으로 하였다. 전산화치료계획시스템(Eclipse version 10.0, Varian, USA)을 이용하여 자유호흡상태 Computed Tomography(CT)와 DIBH CT에서 동일한 전산화치료계획을 수립하여 심장의 체적과 선량을 비교하였고, RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA)의 데이터를 이용하여 환자의 호흡을 분석하였다. 치료 중 Electronic portal imaging device(EPID)를 이용한 Cine Acquisition 방법으로 영상을 획득하여 Varian 사의 Offline Review (ARIA 10, Varian, USA)에서 심장의 장축 거리를 측정하였다. 조사야 내 심장의 포함 정도를 비교 평가하기 위하여 동일한 3개(A, B, C)의 지점에서 길이 측정을 진행하였다. 결 과 : 자유호흡상태와 DIBH를 적용한 두 가지 전산화치료계획에서 심장평균선량 (6.82 vs 1.91 Gy), 심장의 V30 (68.57 vs $8.26cm^3$), V20(76.43 vs $11.34cm^3$)의 차이를 확인 할 수 있었다. 각 환자의 치료 중 DIBH 구간에서 호흡 진폭에 대한 표준편차의 평균값은 각각 ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$로 분석되었다. 치료 중 획득한 영상에서 조사야 내에 포함되는 심장의 길이를 측정한 후 전산화치료계획에서의 심장의 길이와 비교한 결과 최대값은 0.32 cm, 최소값은 0.00 cm로 확인 되었다. 결 론 : 좌측 유방암 환자 치료 시 DIBH를 적용할 경우 심장에 들어가는 선량을 줄이기 위한 전산화치료계획을 수립하는데 용이할 뿐만 아니라, 실제 치료 중에도 심장의 위치에 대한 정확한 재현성과 심장 선량을 감소시킬 수 있다는 것을 확인할 수 있었다. 또한 EPID의 Cine acquisition 방법은 치료 선량 외에 추가적인 선량 없이 DIBH의 재현성 평가를 위한 매우 효과적인 방법이라고 생각된다.