• Title/Summary/Keyword: Chromosorb-102

Search Result 4, Processing Time 0.016 seconds

Rapid Gas Chromatographic Profiling and Screening of Acidic Non-Steroidal Antiinflammatory Drugs in Biological Samples

  • Kim, Kyoung-Rae;Shin, You-Jin;Shim, Won-Hee;Myung, Seoung-Won
    • Archives of Pharmacal Research
    • /
    • v.17 no.3
    • /
    • pp.175-181
    • /
    • 1994
  • The solid-phase extraction (SPF) with subsequent tert-butyldimethylsilyl (TBDMS) derivatization was investigated for the rapid profiling and screening of various carboxylated non-steroidal antiinflammatory drugs (NSAIDs) simultaneously in biological fluid samples. Compared to the conventional SPF in adsorption mode using Chromosorb 102, Chromosorb 107, Carbopak B and Thermosorb, the SPF in partition mode using Chromosorb P as the adsorbent, and ethyl acetate/methylene chloride as the eluting solvents provided hightest overall recovenies of the NSAIDs from aqueous solutions with good precision. The solid-phase extracted NASIDs were silylated with N-methyl-N-(tert-butyldimethylsily)trifuoroacetamide to TBDMS derivatives and directly analyzed by capillary gas chromatography and gs chromatography-mass spectrometry. The usefulness of the present method was examined for the profilling and screening of saliva, serum and urine samples for various NSAIDs simultaneously.

  • PDF

Sorbent Extraction of Some Metal Ions on a Gas Chromatographic Stationary Phase Prior to Their Flame Atomic Absorption Determinations

  • Soylak, M.;Saracoglu, S.;Elci, L.
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.5
    • /
    • pp.555-558
    • /
    • 2003
  • An enrichment/separation system for atomic absorption spectrometric determinations of Cu(Ⅱ), Fe(Ⅲ), Ni(Ⅱ) and Co(Ⅱ) has been established. The procedure is based on the adsorption of the analytes as calmagite chelates on Chromosorb-102. The effects of some parameters including pH, amount of ligand, salt matrix, flow rates of sample and eluent solutions were investigated. Under optimized conditions, the relative standard deviation of the combined method of sample treatment, preconcentration and determination with FAAS (N=5) is generally lower than 5%. The limit of detection (3σ) was between 6.0-112.9 ㎍/L. The results were used for preconcentration of analytes from some sodium and ammonium salt.

Evaluation of Adsorbent Sampling Methods for Volatile Organic Compounds in Indoor and Outdoor Air (실내·외 공기 중 휘발성 유기화합물에 대한 흡착 시료채취 방법의 평가)

  • Baek, Sung-Ok;Moon, Young-Hun
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.496-513
    • /
    • 2004
  • This study was carried out to evaluate the performance of sampling and analytical methodology used for the measurement of toxic volatile organic compounds (VOCs) in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis. Target analytes were 33 compounds including major aromatic compounds such as BTEX, and halogenated compounds. The methodology was investigated with a wide range of different adsorbents which are commercially available and have been frequently adopted for the VOC measurement. A total of 10 adsorbents were tested in this study: 6 carbon-based adsorbents such as Carbotrap, Carbopack B, Carbosieve S-III, Carboxen 1000, Carbotrap C, Activated Charcoal; and 4 polymer-based adsorbents including Tenax, Porapak Q, Chromosorb 102, and Chromosorb 106. The sampling performance was evaluated with respect to the sampling capacity of VOCs with single-adsorbent and multiple-adsorbents methods for standard samples and field samples. As a result, the best adsorbents for single-adsorbent method in the sampling of toxic organic compounds (including benzene, toluene, xylenes etc.) appeared to be Carbotrap, Carbopack B and Tenax TA. On the other hand, Chromosorb 102, Chromosorb 106 and Porapak Q were found to be unsuitable adsorbents for VOC measurement based on thermal desorption method. Multi-adsorbent packings were evaluated with 4 carbon-based adsorbents, which classified by 3 combination sets of double adsorbents and 2 combination sets of triple adsorbents. The results indicated that the most suitable combination for toixc VOC measurements is Carbotrap C with Carbotrap. Multi-sorbents tubes packed with a strong adsorbent such as Carbosieve S-III or Carboxen 1000 were found to be relatively unsuitable for several compounds, not only owing to the effect of migration of adsorbed compounds from weaker adsorbent to stronger adsorbent, but to hydrophobic nature of the adsorbents. Therefore, it should be addressed that selection of a proper adsorbent (or combination of multi sorbents) is extremely important to obtain reliable data for the concentrations of toxic VOCs in indoor and outdoor environments.

Determination of Natural Gas Components by Gas Chromatographic Multicolumn System (기체 크로마토그래피 복합컬럼 시스템에 의한 천연가스 성분의 정량)

  • Choi, Yong-Wook;Choe, Kun-Hyung
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.339-347
    • /
    • 1994
  • A multicolumn system consisted of two valve(10-port and 6-port valve)-three column (28% DC 200, SP 1700 and Chromosorb 102 column) was developed. Nine natural gas components composed of $N_2$, $CH_4$, $CO_2$, $C_2H_6$, $C_3H_8$, $i-C_4H_{10}$, $n-C_4H_{10}$, $i-C_5H_{12}$$n-C_5H_{12}$ completed all the baseline separation within 18 minutes. The accuracy and the precision of this system was tested. The retention times and the peak areas were determined with a repeatability between 0.02 and 0.16%, and less than 1%, respectively. Calibration curves for natural-gas components were plotted by the partial pressure injection method of pure gases, and good linear relationships for each component were presented. By using these calibration curves the accuracy of the multicolumn system compaired with that of the single column system for a certified standard gas of natural gas. As a result, relative error in the single and the multicolumn system was less than 0.5% and 0.04%, respectively. The result of application of this system in the analysis of importing LNG composition showed that the heating values calculated by the multicolum system were estimated lower compared with those calculated by the single column system and consequently, the importing price of LNG was able to be cut down.

  • PDF