• 제목/요약/키워드: Chromium-hexavalent

검색결과 168건 처리시간 0.023초

Nanoporous carbon synthesized from grass for removal and recovery of hexavalent chromium

  • Pathan, Shahin A.;Pandita, Nancy S.
    • Carbon letters
    • /
    • 제20권
    • /
    • pp.10-18
    • /
    • 2016
  • Nanoporous carbon structures were synthesized by pyrolysis of grass as carbon precursor. The synthesized carbon has high surface area and pore volume. The carbon products were acid functionalized and characterized by Fourier transform infrared spectroscopy, X-ray diffraction, Brunauer–Emmett–Teller, transmission electron microscopy, and Energy Dispersive X-ray microanalysis. Acid functionalized nanoporous carbon was explored for use in removal of toxic Cr(VI) ions from aqueous media. An adsorption study was done as a function of initial concentration, pH, contact time, temperature, and interfering ions. The experimental equilibrium data fits well to Langmuir isotherm model with maximum monolayer adsorption capacity of 35.335 mg/g. The results indicated that removal obeys a pseudo-second-order kinetic model, and that equilibrium was reached in 10 min. A desorption study was done using NaOH. The results of the present study imply that acid functionalized nanoporous carbon synthesized from grass is an efficient, renewable, cost-effective adsorbent material for removal of hexavalent chromium due to its faster removal rate and reusability.

우리나라 중소기업 도금공정 근로자의 크롬 및 세척제 폭로에 관한 연구 (A Study on Worker Exposure to Chromium and Degreasing Solvent at Eleetroplating Operation in Small Industry in Korea)

  • 백남원;정문식;이흥근;윤충식;정회경;이경희;이나루
    • 한국산업보건학회지
    • /
    • 제3권1호
    • /
    • pp.110-126
    • /
    • 1993
  • Worker exposures to total chromium, hexavalent chromium (VI), sulfuric acid and alkaline dust at electroplating operations and worker exposures to trichloroethylene (TCE) and methyl chloroform (MCM) at degreasing operations in eleven small industrial plants were evaluated. Appropriate local exhaust ventilation systems for both operations were designed and recommended. Results of the study are summarized as follows ; 1. Out of 134 measurements for airborne hexavalent chromium concentrations, seven were exceeding the Korean occupational health standard of $50{\mu}g/m^3$ and 45 were exceeding the NIOSH standard of $1{\mu}g/m^3$. With an exception of one measurement, concentrations of total chromium were below the Korean standard of $500{\mu}g/m^3$. 2. Worker exposures to chromium were closely related to the existing control methods at the electroplating operations. Local exhaust systems, partial coverage of the tank surface, and antifoaming agents on liquid surface were adopted as control methods. 3. With an exception of one sample, airborne concentrations of sulfuric acid and alkaline dusts were below the applicable occupational heatlth standards. 4. Three plants indicated that airborne concentrations of TCE and MCM were exceeding the Korean standards. Other plants showed lower concentrations than the standards. It should be noted that generally, the activities and workloads on the day of surveys were less than normal. 5. Since the most existing ventilation systems did not satisfy the ACGIH criteria, the ventilation systems should be improved. Some examples for designing appropriate ventilation systems are presented.

  • PDF

Reduction of Hexavalent Chromium by Escherichia coli ATCC 33456 in Batch and Continuous Cultures

  • Bae, Woo-Chul;Kang, Tae-Gu;Kang, In-Kyong;Won, You-Jung;Jeong, Byeong-Chul
    • Journal of Microbiology
    • /
    • 제38권1호
    • /
    • pp.36-39
    • /
    • 2000
  • Toxic hexavalent chromium, Cr(VI), was reduced to a less toxic trivalent chromium form by E. coli ATCC 33456. The suitable electron donor for Cr(VI) reduction was glucose. E. coli ATCC 33456 was more resistant to metal cations than other reported Cr(VI) reducing microorganisms. Cell growth was inhibited by the presence of Cr(VI) in a liquid medium and Cr(VI) reduction accompanied cell growth. With a hydraulic retention time of 20 h, Cr(VI) reducing efficiency was 100% to 84% when Cr(VI) concentration in the influent was in the range of 10 to 40 mg L$\^$-1/. Specific rate of Cr(VI) reduction was 2.41 mg Cr(VI) g DCW$\^$-1/ h$\^$-1/ when 40 mg L$\^$-1/ of Cr(VI) influent was used. This result suggested the potential application of E. coli ATCC 33456 for the detoxification of Cr(VI) in Cr(VI) contaminated wastewater.

  • PDF

Synthesis of Nanoscale Zerovalent Iron Particle and Its Application to Cr(VI) Removal from Aqueous Solutions

  • Awad, Yasser M.;Abdelhafez, Ahmed A.;Ahmad, Mahtab;Lee, Sang-Soo;Kim, Rog-Young;Sung, Jwa-Kyung;Ok, Yong-Sik
    • 한국환경농학회지
    • /
    • 제29권4호
    • /
    • pp.402-407
    • /
    • 2010
  • Zerovalent iron (ZVI) is one of the most commonly used metallic reducing agents for the treatment of toxic contaminants in wastewater. Traditional ZVIs are less effective than nanoscale ZVI (nZVI) due to prolonged reaction time. However, the reactivity can be significantly increased by reducing the size of ZVI particles to nanoscale. In this study, nZVI particles were synthesized under laboratory condition and their efficiency in removing hexavalent chromium (Cr(VI)) from aqueous solutions were compared with commercially available ZVI particles. The results showed that the synthesized nZVI particles (SnZVI) reduced >99% of Cr(VI) at the application rate of 0.2% (w/v), while commercial nZVI (CnZVI) particles resulted in 59.6% removal of Cr(VI) at the same application rate. Scanning electron micrographs (SEM) and energy dispersive spectra (EDS) of the nZVI particles revealed the formation of Fe-Cr hydroxide complex after reaction. Overall, the SnZVI particles can be used in treating chromium contaminated wastewater.

Reduction of hexavalent chromium by pseudomonas aeruginosa HP014

  • Oh, Young-Sook;Choi, Sung-Chan
    • Journal of Microbiology
    • /
    • 제35권1호
    • /
    • pp.25-29
    • /
    • 1997
  • Microbial reduction of hexavalent (VI) to trivalent (III) chromium decreases its toxicity by two orders of magnitude. In order to investigate the nature of Cr-reduction, Cr-resistant Pseudomonas aeruginosa HP014 was isolated and tested for its reduction capability. At the concentration of 0.5 mM Cr(VI), cell growth was not inhibited by the presence of Cr(VI) in a liquid medium, and Cr(VI) reduction was accompanied by ell growth. When cell-free extract was tested, the reduction of Cr(VI) showed a saturation kinetics with the maximum specific activity of 0.33 .mu.mol min$\^$-1/ mg$\^$-1/ cell protein, and an apparent K. of 1.73 mM Cr(VI). The activity required either NADH or NADPH as an electron donor. However, NADPH gave 50% as mush activity as sequently the supernatant and pelleted membrane fractions were tested for Cr(VI) reduction activity. The supernatant of the centrifugation showed almost the same Cr(VI) reduction activity as compared with that of the cell-free extract, indicating that the Cr(VI)-reducing activity of P. aeruginosa HP-14 is due to soluble enzyme. Moreover, the activity appeared to be the highest among the known activities, suggesting that the strain might be useful for remediation of Cr(VI)-contaminated sites.

  • PDF

Growth of Phaseolus mungo under chromium stress - influence of chromate reducing bacteria

  • M. Rajkumar;Na, R.gendran;Lee, Kui-Jae;Lee, Wang-Hyu
    • 한국식물병리학회:학술대회논문집
    • /
    • 한국식물병리학회 2003년도 정기총회 및 추계학술발표회
    • /
    • pp.105.1-105
    • /
    • 2003
  • The Plant growth Promoting rhizobacteria (PGPR), Pseudomonas sp. (A3) and Bacillus sp. (AT33) were isolated from the rhizosphere of Amaranthus blitum collected from soil contaminated with chromium. Both bacterial strains quantitatively reduced hexavalent chromium to trivalent chromium. Pseudomonas sp. broughter greater conversion of Cr6+ in the medium (100%) as compared to Bacillus sp.(62%). Phaseolus mungo seeds inoculated with Pseudomonas sp. or Bacillus sp. were grown under different concentration of chromium. The monitored parameters included elongation of shoot and root, fresh weight, dry weight and concentration of chromium in the shoot and root systems. As compared to non inoculated seedlings those inoculated with A3 and AT33 exhibited better growth.

  • PDF

Growth of Phaseolus mungounder chromium stress - influence of chromate reducing bacteria

  • M. Rajkumar;Lee, Kui-Jae;Seo, Jae-Hwan;Lee, Wang-Hui
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2003년도 제10차 국제학술회의 및 추계정기 학술발표회
    • /
    • pp.57-57
    • /
    • 2003
  • The plant growth promoting rhizobacteria (PGPR), Pseudomonas sp. (A3) and Bacillus sp. (AT33) were isolated from the rhizosphere of Amaranthus blitum collected from soil contaminated with chromium. Bothbacterial strains quantitatively reduced hexavalent chromium to trivalent chromium. Pseudomonas sp. broughter greater conversion of Cr6+ in the medium (100%) as compared to Bacillus sp.(62%). Phaseolus mungo seeds inoculated with Pseudomonas sp. or Bacillus sp. were grown under different concentration of chromium. The monitoredparameters included elongation of shoot and root, fresh weight, dry weight and concentration of chromium in the shoot and root systems. As compared to non inoculated seedlings those inoculated with A3 and AT33 exhibited better growth.

  • PDF

Plasma Aided Process As Alternative to Hard Chromium Electroplating

  • Kwon, Sik-Chol;Lee, K.H.;Kim, J.K.;Kim, M.;Lee, G.H.;Nam, K.S.;Kim, D.;Chang, D.Y.
    • 한국표면공학회지
    • /
    • 제36권1호
    • /
    • pp.48-58
    • /
    • 2003
  • This paper will present an overview of toxicity of hexavalent chromium as well as effort for its replacement by a wide spectrum of alternative materials and technologies. Cr-based materials such as trivalent electrodeposit will be one of strong candidates for hard chromium by surface modification of its surface hardness. Ni-base alloy deposits has proved its application in specific mold for glass. HVOF has been studied in aircraft and military sector. There are still under way of development for commercially available alternatives. To date, no single coating has been identified as universal process as comparable to conventional hard chromium electroplating.

Ion Chromatography/Visible Absorbance Detection을 이용한 Cr(VI) 분석의 정확도 및 정밀도 평가 (Accuracy and Precision of Ion Chromatography/Visible Absorbance Detection for Analyzing Hexavalent Chromium Collected on PVC Filter)

  • 신용철;오세민;백남원
    • 한국산업보건학회지
    • /
    • 제7권2호
    • /
    • pp.223-232
    • /
    • 1997
  • The accuracy and precision of a modified method of NIOSH Method 7600 and EPA method 218.6 was determined for analyzing hexavalent chromium, Cr(VI), collected on PVC filter from workplace air. The method was designed to extract from Cr(VI) on PVC filter with a alkali solution, 2% NaOH/3% $Na_2CO_3$, and to analyze it using ion chromatography/visible absorbance detection(IC/VAD). The results and conclusion are as the following. 1. The peak of Cr(VI) was separated sharply on chromatogram and was linearly related with Cr(VI) concentration in sloution. The correlation coefficient was 0.9999 in a calibration curve. The limit of detection was 0.25 $0.25{\mu}g/sample$. 2. The accuracy(% recovery) was 93.3% in a set of sample($9-50{\mu}g$) stored for a day, and 100.1%($10-60{\mu}g$) in another set of samples stored for 2 hours. It is assumed that the difference in recovery by storage time was due to reduction of Cr(VI) to Cr(III). 3. The precision(coefficient of variation, CV) of the method was 0.015 in spiked samples with Cr(VI) standard solution, and 0.010 in spiked samples with plating solution from a chrome electroplating factory. The overall CV in all types of samples was 0.0013. 4. The Cr(VI) was stable in 2% NaOH/3% $Na_2CO_3$ at least for 10 hours. In conclusion, the IC/VAD method is appropriate for determining low-level Cr(VI) in workplace air containing various interferences.

  • PDF