• 제목/요약/키워드: Chromatographic stationary phases

검색결과 44건 처리시간 0.026초

Liquid Chromatographic Resolution of Pyrethroic Acids and Their Esters on Chiral Stationary Phases

  • Lee, Won-Jae;Baek, Chae-Sun;Jing, Yu-Jin
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.224.2-224.2
    • /
    • 2003
  • Pyrethroic acids are essential chiral intermediates of the pyrethroids, which account for about 25% of the world insecticide market and are found to be some of the most effective commercially available pesticides. It was demonstrated that polysaccharide-derived chiral stationary phases (CSPs) are very efficient for the separation of the enantiomers of pyrethroid acids. It was observed that the enantioseparation of pyrethroic methyl ester and ethyl derivatives was well accomplished on brush-type WhelkO-1. (omitted)

  • PDF

Chromatographic Selectivity of Cyano-Bonded Silica Columns in RPLC Based on the Linear Solvation Energy Relationships

  • Park, Jung-Hag;Jang, Myung-Duk;Kwon, Se-Mok
    • Bulletin of the Korean Chemical Society
    • /
    • 제13권1호
    • /
    • pp.75-79
    • /
    • 1992
  • Differences in chromatographic properties in RPLC of four brands of cyano bonded silica stationary phases are rationalized in terms of the type and relative strength of the solute-stationary phase interactions, which can be readily inferred from multiple linear regression analyses of retention data for a set of standard compounds on the stationary phases under study based on the linear solvation energy relationships (LSERs). Although four brands of cyano bonded columns studied (CPS-Hypersil, Ultrasphere cyano, Spherisorb-CN and ${\mu}$-Bondapak-CN) have similar bonding density and have been prepared from monofunctional cyanopropylsilane reagents, they possess quite different, relative hydrogen bonding (HB) donor and acceptor strengths. Comparison of the retention behavior on a cyano-bonded silica column with that on an ODS column shows that there are significant differences in the strength of HB interactions between the solute and the stationary phase on the two columns with different functionalities. Information on the differences in the interaction characteristics among brands of the cyano-bonded silica columns and between the ODS and cyano-bonded columns can be utilized to optimize the selectivity for a given separation on these columns.

Synthesis, Characterization and Enhanced Selectivity in RP-HPLC of Polar Carbonyl Group Embedded Poly (Vinyl Octadecanoate) Grafted Stationary Phase by Simple Heterogeneous "Graft from" Technique

  • Rana, Ashequl A.;Karim, Mohammad Mainul;Takafuji, Makoto
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권1호
    • /
    • pp.77-82
    • /
    • 2011
  • A new high performance liquid chromatograpgy (HPLC) stationary phase that possesses an internal carbonyl functional group is synthesized by heterogeneous "graft from" method. This new stationary phase, poly (vinyl octadecanoate) grafted silica (Sil-2) is then characterized by different physico-chemical methods such as diffuse reflectance infrared fourier transform, suspension state $^1H$ NMR, solid state $^{13}C$ CP/MAS NMR, $^{29}Si$ CP/MAS NMR, elemental analysis and thermogravimetric analysis. Chromatographic properties of Sil-2 were evaluated under reversed phase condition by separating polycyclic aromatic hydrocarbons (PAHs) and comparing the chromatographic results with those on polymeric as well as monomeric octadecylated silica stationary phases.

Efficient Immobilization of Polysaccharide Derivatives as Chiral Stationary Phases via Copolymerization with Vinyl Monomers

  • Chen, Xiaoming;Okamoto, Yoshio;Yamamoto, Chiyo
    • Macromolecular Research
    • /
    • 제15권2호
    • /
    • pp.134-141
    • /
    • 2007
  • The direct chromatographic separation of enantiomers by chiral stationary phases (CSPs) has been extensively developed over the past two decades, and has now become the most popular method for the analytical and preparative separations of enantiomers. Polysaccharide derivatives coated onto silica gel, as CSPs, playa significantly important role in the enantioseparations of a wide range of chiral compounds using high-performance liquid chromatography (HPLC). Unfortunately, the strict solvent limitation of the mobile phases is the main defect in the method developments of these types of coated CSPs. Therefore, the immobilization of polysaccharide derivatives onto silica gel, via chemical bonding, to obtain a new generation of CSPs compatible with the universal solvents used in HPLC is increasingly important. In this article, our recent studies on the immobilization of polysaccharide derivatives onto the silica gel, as CSPs, through radical copolymerization with various vinyl monomers are reported. Polysaccharide derivatives, with low vinyl content, can be efficiently fixed onto silica gel with high chiral recognition.

아미노산 에스테르의 벤조피논 이민 유도체의 액체 크로마토그래피의 광학분리 (Liquid Chromatographic Resolution of α-Amino Acid Esters as Benzophenone Imine Derivatives)

  • 윤원남;서문준;황호;이원재
    • KSBB Journal
    • /
    • 제27권3호
    • /
    • pp.167-171
    • /
    • 2012
  • A convenient liquid chromatographic enantiomer separation of several ${\alpha}$-amino acid esters as benzophenone Schiff base derivatives on covalently immobilized chiral stationary phases (CSPs) derived from polysaccharide derivatives was developed. The benzophenone imine derivatives of ${\alpha}$-amino acid esters were readily prepared by stirring benzophenone imine and the ${\alpha}$-amino acid ester hydrochloride salts in 2-propanol. The chromatographic conditions used on all CSPs were 0.5% or 5% 2-propanol/hexane (V/V) as the mobile phases at 1 mL/min of flow rate and UV 254 nm detection. The performance of Chiralpak IC among all CSPs was superior to that of the other CSPs for resolution of benzophenone imine derivatives of ${\alpha}$-amino acid esters. It is expected that the developed analytical method will be useful for enantiomer resolution of other ${\alpha}$-amino acid esters as benzophenone Schiff base derivatives.

고성능 액체크로마토그래피의 다당유도체를 기초로 한 키랄 고정상에서 이동상 첨가제가 키랄 아민의 광학분리에 미치는 영향 (Effect of Mobile Phase Additive on Enantiomer Resolution for Chiral Amines on Polysaccharide-derived Chiral Stationary Phases by High Performance Liquid Chromatography)

  • 백만정;윤혜란;이원재
    • KSBB Journal
    • /
    • 제29권3호
    • /
    • pp.205-209
    • /
    • 2014
  • Chromatographic enantiomer resolution of chiral amines was performed on several covalently immobilized and coated chiral stationary phases (CSPs) based on polysaccharide derivatives under the mobile phase conditions containing base or acid or acid/base additive. The chromatographic parameters including separation factors and capacity factors were greatly influenced by the nature of the mobile phase containing base or acid or salt additive as well as the used CSPs. When 0.05% triethylamine/0.05% trifluoroacetic acid as an additive in the mobile phase was used on all CSPs in this study, the greatest enantiomer resolution was observed except for Chiralpak AD. Also, it was shown that the change of base additive into acid or salt in the mobile phase may directly affect chiral recognition mechanisms between the chiral selectors and analytes occurring during enantiomer separation, resulting in the change of elution orders.

고성능 액체 크로마토그래피에 의한 다당 유도체의 키랄 고정상에서 플록세틴의 새롭게 개발된 분석 및 반분취의 광학분리 (A Newly Developed Analytical and Semi-preparative Enantiomer Separation of Fluoxetine using Polysaccharide-derived Chiral Stationary Phases by High Performance Liquid Chromatography)

  • 김석진;남경욱;박보현;이스람 포크롤;이원재
    • KSBB Journal
    • /
    • 제31권3호
    • /
    • pp.186-191
    • /
    • 2016
  • A liquid chromatographic method for the enantiomer separation of fluoxetine was performed using covalently bonded and coated type polysaccharide-derived chiral stationary phases (CSPs). The degree of enantioseparation is affected by the used CSPs and mobile phases. The performance of Chiralpak IC was superior to the other CSPs used in this study. Out of various solvent composition and additives, the greatest separation and resolution was observed using Chiralpak IC with mobile phase of 2-propanol in hexane with diethylamine as an additive. Semi-preparative separation of fluoxetine was performed on the analytical Chiralpak IC column to obtain (R)- and (S)-fluoxetine enantiomer with high chemical and optical purity. From the overall study, the developed liquid chromatographic method on polysaccharide-derived CSPs is expected to be very useful for the enantiomer separation of fluoxetine.

Immobilization of Styrene-acrylamide Co-polymer on Either Silica Particles or Inner Surface of Silica Capillary for the Separation of D-Glucose Anomers

  • Ali, Faiz;Kim, Yune Sung;Cheong, Won Jo
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권2호
    • /
    • pp.539-545
    • /
    • 2014
  • Styrene-acrylamide co-polymer was immobilized on porous partially sub-$2{\mu}m$ silica monolith particles and inner surface of fused silica capillary ($50{\mu}m$ ID and 28 cm length) to result in ${\mu}LC$ and CEC stationary phases, respectively, for separation of anomeric D-glucose derivatives. Reversed addition-fragmentation transfer (RAFT) polymerization was incorporated to induce surface polymerization. Acrylamide was employed to incorporate amide-functionality in the stationary phase. The resultant ${\mu}LC$ and CEC stationary phases were able to separate isomers of D-glucose derivatives with high selectivity and efficiency. The mobile phase of 75/25 (v/v) acetonitrile (ACN)/water with 0.1% TFA, was used for HPLC with a packed column (1 mm ID, 300 mm length). The effects of pH and ACN composition on anomeric separation of D-glucose in CEC have been examined. A mobile phase of 85/15 (v/v) ACN/30 mM sodium acetate pH 6.7 was found the optimized mobile phase for CEC. The CEC stationary phase also gave good separation of other saccharides such as maltotriose and Dextran 1500 (MW~1500) with good separation efficiency (number of theoretical plates ~300,000/m).

Liquid Chromatographic Reaolution of N-Protected α -Amino Acids as Their Anilide and 3,5-Dimethylanilide Derivatives on Chiral Syationary Phases Derived fron (S)-Leucine

  • Hyun, Myung-Ho;Cho, Yoon-Jae;Baik, In-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권9호
    • /
    • pp.1291-1294
    • /
    • 2002
  • Various racemic N-protected ${\alpha}-amino$ acids such as N-t-BOC-(tert-butoxycarbonyl), N-CBZ-(benzyloxycarbonyl) and N-FMOC-(9-fluorenylmethyloxycarbonyl) ${\alpha}-amino$ acids were resolved as their anilide and 3,5-dimethylanilde derivatives on an HPLC chira l stationary phase (CSP) developed by modifying a commercial (S)-leucine CSP. The chromatographic resolution results were compared to those on the commercial (S)-leucine CSP. The resolutions were greater on the modified CSP than those on the commercial CSP with only one exception, the resolution of N-t-BOC-phenylglycine anilide. In addition, the chromatographic resolution behaviors were quite consistent except for the resolution of N-protected phenylglycine derivatives, the (S)-enantiomers being retained longer. Based on the chromatographic resolution behaviors and with the aid of CPK molecular model studies, we proposed a chiral recognition mechanism for the resolution of N-protected ${\alpha}-amino$ acid derivatives. However, for the resolution of N-protected phenylglycine derivatives, a second chiral recognition mechanism, which competes in the opposite sense with the first chiral recognition mechanism, was proposed. The two competing chiral recognition mechanisms were successfully used in the rationalization of the chromatographic behaviors for the resolution of N-protected phenylglycine derivatives.