• Title/Summary/Keyword: Chopping

Search Result 181, Processing Time 0.026 seconds

Photoacoustic Determination of Thermophysical Properties of Thin Metallic Plates by Using Parameter Estimation (광음향학적 방법에 의한 얇은 금속판의 열물성 측정)

  • 김석원
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.219-226
    • /
    • 1991
  • The phase and the amplitude of the photoacoustic signal were measured as a function of chopping frequency for several kinds of widely used thin metallic plates (stainless steel 304, brass, aluminum and copper) attached to plexiglass backing. The experimental data have been analyzed systematically by parameter estimation technique based on the two-layer model developed from Rosencwaig-Gersho (R-G) theory. Using this analysis, the values of thermal diffusivity and thermal effusivity of the materials have been determined.

  • PDF

A Simulation Study of a Chopping System for Extracting a Pulsed Beam from a Cyclotron

  • Kim, Jae-Hong;Hong, Seong-Gwang;Kim, Mi-Jeong;Kim, Seong-Jun;Kim, Myeong-Jin;Kim, Do-Gyun;Yun, Jong-Cheol;Kim, Jong-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.537-537
    • /
    • 2013
  • Cyclotron-accelerated ion beams are used for various researches, such as nuclear physics, nuclear chemistry, biotechnology, and material sciences including radio-isotope production. Recently considerable applications are asked to the cyclotron development undertaken to meet user requirements of various ions'energies, intensities, and their pulsed beams. For instance, a cocktail beam acceleration technique rapidly changing the ion species and energies was developed to irradiating integrated circuit chips. Also a chopping system in a cyclotron injection line is considered for producing a pulsed ion beam with a relatively long period compared with that generated by the resonance frequency. For the research in neutron time-of-flight measurement, a single-pulsed beam with a repetition interval of the order of mili-seconds or longer is necessary to have a good resolution and to remove background events. In this paper a feasibility of pulsed beam with an external ion source is simulated by adopting a combination system of a chopper accompanying with a bunching stage in the injection line and an additional chopper after the exit of the cyclotron in order to produce beam pulses with a range of $1{\mu}s{\sim}1ms$ periods from a resonance RF cycle. The pulseperiod will be adjusted by chopping the number of beam bunches from the injected pulses in the injection line. However, the longer pulses will have reduced number of beam pulses and sacrificed beam currents. Because the beam users need an intense single pulsed beam, a careful tuning of the acceleration phase and a high-intense external ion source are necessary to achieve an intense single-pulsed beam from the cyclotron. It is essential to strictly match the acceleration phase of injected beams in the central region of the cyclotron to improve its efficiency. An effect of space charge at each pulse from the ion source will be also considered.

  • PDF

'Survey on Bacteriological Contamination of Moving Tavern in Seoul Area' ('노상주점의 위생상태에 관한 미생물학적 조사')

  • Yu Byong Tai
    • Journal of environmental and Sanitary engineering
    • /
    • v.1 no.1 s.1
    • /
    • pp.59-67
    • /
    • 1986
  • This sanitary survey was carried out to investigate the bacteriological contamination of cooking utensils and foods of moving tavern in eight sample sites of Seoul area. The results of survey were as follows: 1. The counts by means of total bacteria in cooking utensils and food samples by standard plate count method were as follow: $5.6\times10^5$ per gm in dishcloth, $3.1\times10^6$ per ml in dishwater. In food samples, $5.4\times10^5$ per gm in meat was higher than other samples. 2. The average counts total coliform and fecal coliform in samples by MPN method were as follow: $3.4\times10^4$ MPN per 100ml, and $1.3\times10^2$ MPN per 100ml in chopping board, $6.1\times10^4$MPN per gm and $1.0\times10^2$ MPN per gm in dishcloth, $1.8\times10^5$ MPN per 100ml and $6.1\times10^2$ MPN per 100ml in dishwater. In food samples, $3.1\times10^4$MPN per gm and $2.0\times10^2$ MPN per gm in meat was higher than other samples. 3. The counts by means of Pseudomonas in samples by MPN method were as follow: $2.8\times10^3$ MPN per 100ml in chopping board, $4.7\times10^3$ MPN per gm in dishcloth $5.6\times10^3$ MPN per 100ml in dishwater. In food samples, $2.4\times10^3$ MPN per gm in shellfish was higher than other samples. 4. Isolation cases of Food poisoning organisms from samples were as follow: Staphylococci was detected 9 cases $(17.6\%)$ in chopping board, 7 cases $(13.6\%)$ in dishcloth. In food samples, 9 cases $(25.7\%)$ in meat, 1 case $(4\%)$ in fish samples. Salmonella was detected 2 cases $(3.9\%)$ in dishwater, 1 case in meat samples.

  • PDF

Electromagnetic Transient Program Modeling for Analysis of Switching Over-Voltage on Shunt Reactor (분로리액터 개폐 과전압 해석을 위한 EMTP 모델링)

  • Oh, SeungRyle;Jun, InYoung;Han, KiSun;Kang, JiWon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.393-397
    • /
    • 2020
  • Shunt reactor, a facility for reactive power compensation, is switched several times a day depending on the load pattern. When the circuitbreaker opens the shunt reactor over-voltage is generated by several factors which degrade the insulating performance of internal parts of the circuit-breaker and cause severe voltage stress on the equipment in the power system. Transient phenomenon occurring during the switching of shunt reactor are available in laboratories that verify the performance of the circuit-breaker by simulating the power system. However, it is difficult to measure the transient phenomenon that occurs during actual operation in actual power system due to many limitations. Therefore, this paper deals with the modeling using EMTP to analyze the reignition and current chopping which causes more severe transient recovery voltage in the small inductive current breaking in actual power systems. In addition, this paper analyzes the main phenomenon that cause circuit-breaker failure in opening shunt reactor using EMTP model.

Microbial Contamination in Kitchens and Refrigerators of Korea Households

  • Hong, Joonbae;Lim, Seung-Yong
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.4
    • /
    • pp.303-308
    • /
    • 2015
  • The objectives of this study were to investigate the microbial contamination level of domestic kitchen environments and to provide information to improve food safety in 50 domestic house kitchens located in Seoul, Incheon, and Gyeonggi-do. Dishcloth, chopping board, and refrigerator swabs were examined for the presence of coliforms, Salmonella spp., Campylobacter jejuni/coli, Escherichia coli, Listeria monocytogenes, and Staphylococcus aureus. The means and standard deviations of coliform counts for dishcloths was $4.8{\pm}1.84log\;CFU/100g$, chopping boards, and refrigerator drawers were $4.04{\pm}1.53$, $4.11{\pm}1.65log\;CFU/100cm^2$, respectively. Salmonella spp. and Campylobacter jejuni/coli were not detected in all samples. E. coli were detected in 3 on the dishcloths and 1 of 50 samples in the refrigerator drawer. Listeria monocytogenes was detected in the drawer of the refrigerator in 2 of 50 samples. In the case of Staphylococcus aureus, the detection on dishcloths, chopping boards, and drawers in refrigerators was 21, 12, and 14 of 50 samples, respectively. The results of microbiological tests of domestic kitchen utensils can be used to emphasize the importance of the sanitary conditions in domestic kitchen environments.

Energy Expenditure in Crossbred Cattle Fed Paddy Straw of Different Form

  • Bhatta, Raghavendra;Kumar, Vijay;Sridhar, Manpal;Singh, Khub
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.12
    • /
    • pp.1755-1760
    • /
    • 2006
  • Studies were carried out at the National Institute of Animal Nutrition and Physiology, India to determine the effect of feeding chopped paddy straw (Oryza sativa) on the energy expenditure in crossbred cattle. Four crossbred cattle male, aged 5-6 years and weighing about 450 kg were used for this study. Three experimental trials, one each for the feeding of un-chopped paddy straw offered ad libitum (UCA), chopped paddy straw fed at restricted level (CR) and chopped paddy straw offered ad libitum (CA) were conducted. The quantity of un-chopped paddy straw consumed during UCA was assumed as the voluntary intake by the cattle and the same quantity was offered after chopping during CR. Each trial comprised of 21 d preliminary feeding period and 5 d of observation recording period. Expired gas was collected in Douglas bags using a face-mask and three-way valve at 6 hourly intervals i.e., at 09.30, 15.30, 21.30, and 03.30 h throughout the observation period. Expired gas and ambient air inspired by the animals were analyzed for the oxygen content through paramagnetic oxygen analyzer. Energy expenditure (EE) by the animals was calculated by determining the volume of oxygen consumed per minute (STP) and multiplying by 4.825. Paddy straw used in all the three trials contained (g/kg DM) 90.0 CP, 786 OM, 700 NDF, 489 ADF, 357 Cellulose and 60.0 ADL. Metabolizable energy (ME) was 6.9 MJ/kg DM. Dry matter intake (DMI) both in UCA and CR was about 6.8 kg, except that it was chopped in CR. Chopping has resulted in 32% improvement (9 kg) in DMI of CA as compared to that of UCA. Although ME intake was similar in UCA and CR (47.2 MJ/day), energy expenditure (EE) was higher in UCA (23.3 MJ) when compared to that of CR (19.5 MJ). The ME intake (63.3 MJ) as well as EE (27.1 MJ) was highest in CA. Energy expenditure when expressed as MJ/kg DMI was 3.48, 2.90 and 3.12; whereas as per cent of ME intake it was 50, 41 and 44 in UCA, CR and CA respectively. Our study has unequivocally confirmed that chopping of poor quality roughages like paddy straw has definite advantages not only in terms of improving the intake by decreasing the time taken for ingestion but also in reducing the energy cost of eating.

Implementation of an analog front-end for electroencephalogram signal processing (뇌전도 신호 처리용 아날로그 전단부 구현)

  • Kim, Min-Chul;Shim, Jae Hoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.15-18
    • /
    • 2013
  • This paper presents an analog front-end for electroencephalogram(EEG) signal processing. Since EEG signals are typically weak and located at very low frequencies, it is imperative to implement an amplifier with high gain, high common-mode rejection ratio(CMRR) and good noise immunity at very low frequencies. The analog front-end of this paper consists of a programmable-gain instrumentation amplifier and a band-pass filter. A frequency chopping technique is employed to remove the low-frequency noise. The circuits were fabricated in 0.18um CMOS technology and measurements showed that the analog front-end has the maximum gain of 60dB and >100dB CMRR over the programmable gain range.

A Sensorless Switched Reluctance Drive System Based on the Improved Simplified Flux Method

  • Li, Zhenguo;Song, Andong;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.4
    • /
    • pp.477-482
    • /
    • 2012
  • This paper describes a new rotor position sensorless control method for SRM drives based on an improved simplified flux linkage method. In the traditional simplified flux linkage method, every phases take turns conduction and current chopping control method is used. Every phases take turns conduction means turning on the incoming working phase while turning off the working phase. This conduction mode causes coupling between turn-on and turn-off angles, which goes against optimal efficiency or torque ripple minimization with sensorless speed control. In the improved simplified flux linkage method, turn-off angle is calculated by flux loop, the turn-on angle can be given arbitrarily and has no relations with the turn-off angle, and the current chopping control method is used. The speed and rotor position can be estimated then. Finally, a sensorless SRM speed control system and an experiment platform with DSP are built and validity of this method is confirmed.

The Effects of PNF Technique Versus Trunk Exercise Program on the Pain, Disability and Balance in Chronic LBP Patients (만성 요통환자에 대한 PNF와 체간운동프로그램이 통증, 기능장애 및 균형에 미치는 효과)

  • Jeon, Hye-Jin;Lee, Moon-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.665-673
    • /
    • 2009
  • This study was conducted to compare the PNF and Trunk Exercise Program has effectiveness on the pain, disability, static and dynamic balance in chronic low back pain patients. To evaluate the effects of exercise, subjects were evaluated by using VAS for pain, Oswestry disability index for disability, One leg stand test for static balance and Balance System for dynamic balance test. Pain, Oswestry disability index, One leg stand test, and Dynamic balance test in PNF had statistical significance than Trunk exercise program(p<0.05). So this results were suggested that the lifting and chopping pattern of PNF was effective on pain, disability and balance in chronic low back pain patients.